Tomonobu Abe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomonobu Abe has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Hajime Sakurai
Department of Cardiovascular Surgery, Social Insurance Chukyo Hospital, Nagoya, Japan
8 shared publications- Hideki Oshima
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
4 shared publications Rei Noda
4 shared publicationsTakafumi Terada
4 shared publications- Akihiko Usui
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
3 shared publications - Junya Sugiura
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
3 shared publications
Latest Publications
- 1 April 2016
- Vol. 69 (4) , 321-4
[Aortic Valve Replacement of Quadricuspid Valve with Regurgitation].
Congenital quadricuspid aortic valve is a very rare malformation. In most cases it has been found incidentally at aortic valve surgery or at autopsy. It frequently causes aortic regurgitation, which may become manifest in adulthood and require surgical treatment. We reported 4 cases of aortic regurgitation with quadricuspid aortic valve. In all cases, aortic valve replacement was preformed with prosthetic valve, and their postoperative courses were uneventful. Two were Hurwitz's classification type b, one was type a and the last patient was type c. Although quadricuspid aortic valve is a rare anomaly, its potential for severe valve failure in adulthood should be kept in mind.
- 1 April 2016
- Vol. 69 (4) , 321-4
[Aortic Valve Replacement of Quadricuspid Valve with Regurgitation].
Congenital quadricuspid aortic valve is a very rare malformation. In most cases it has been found incidentally at aortic valve surgery or at autopsy. It frequently causes aortic regurgitation, which may become manifest in adulthood and require surgical treatment. We reported 4 cases of aortic regurgitation with quadricuspid aortic valve. In all cases, aortic valve replacement was preformed with prosthetic valve, and their postoperative courses were uneventful. Two were Hurwitz's classification type b, one was type a and the last patient was type c. Although quadricuspid aortic valve is a rare anomaly, its potential for severe valve failure in adulthood should be kept in mind.
- 1 June 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (6) , 2017-2023
Impact of Surgical Stroke on the Early and Late Outcomes After Thoracic Aortic Operations
- 1 June 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (6) , 2017-2023
Impact of Surgical Stroke on the Early and Late Outcomes After Thoracic Aortic Operations
- 1 July 2014
- Vol. 67 (8) , 623-9
[Cerebral blood flow monitoring].
Cerebral ischemic events remain a major problem in patients undergoing cardiac and thoracic aortic surgery. Efforts to improve outcomes have been made in many aspects which include cerebral monitoring. New technology is making it possible to shed a light to the brain, which historically used to be a black box during general anesthesia in the operating room. Cerebral brain monitoring methods include cerebral oxymetry using near infrared spectroscopy, trans cranial Doppler, Jugular venous oxygen saturation, bispectral index, temporal artery pressure monitoring. Cerebral oxymetry probably is the most commonly used method among these based on its simplicity and reproducibility. Though it is easy to obtain numbers from cerebral oxymetry, it is important to understand the principle and the limitations to interpret the results, properly.
- 1 July 2014
- Vol. 67 (8) , 623-9
[Cerebral blood flow monitoring].
Cerebral ischemic events remain a major problem in patients undergoing cardiac and thoracic aortic surgery. Efforts to improve outcomes have been made in many aspects which include cerebral monitoring. New technology is making it possible to shed a light to the brain, which historically used to be a black box during general anesthesia in the operating room. Cerebral brain monitoring methods include cerebral oxymetry using near infrared spectroscopy, trans cranial Doppler, Jugular venous oxygen saturation, bispectral index, temporal artery pressure monitoring. Cerebral oxymetry probably is the most commonly used method among these based on its simplicity and reproducibility. Though it is easy to obtain numbers from cerebral oxymetry, it is important to understand the principle and the limitations to interpret the results, properly.
- 1 October 2013
- Vol. 66 (11) , 960-4
[Surgical strategy for extended aortic arch aneurysm].
The management of an extended aortic arch aneurysm still remains a clinical challenge. Open surgery can be invasive for the patients with comorbidities. Since thoracic endovascular aneurysm repair (TEVAR) was introduced, hybrid therapy has been applied for the extended arch aneurysm. From 1997 to 2013, 379 patients have undergone aortic arch surgery. Of those, 241 patients of non-dissection aneurysm were studied. Open surgical repair with L-shaped thoracotomy was done in 28 patients, frozen elephant trunk( FET) in 30 patients, long elephant trunk( LET) with 2nd TEVAR in 21 patients, debranched TEVAR in 10 patients and standard arch grafting in 152 patients as a control group. The brain infarction rate was high in debranched TEVAR (40%) and L-shaped group (25%). The paraplegia rate was high in FET group( 23.3%). The respiratory failure rate was high in the L-shaped group and the LET group. In-hospital mortality was 0.0% in the L-shaped group, 6.7% in the FET group, 4.8% in the LET group, 20% in the debranched group and 0.7% in the control group. The debranched TEVAR group is our early experience, and the recent outcomes of this procedure have improved. The management of extended aortic arch aneurysm has changed with hybrid approach combined with TEVAR. Open repair is still the gold standard, but hybrid therapy is used for high-risk patients. Off-pump debranched TEVAR tends to be applied for extended arch aneurysm.
- 1 October 2013
- Vol. 66 (11) , 960-4
[Surgical strategy for extended aortic arch aneurysm].
The management of an extended aortic arch aneurysm still remains a clinical challenge. Open surgery can be invasive for the patients with comorbidities. Since thoracic endovascular aneurysm repair (TEVAR) was introduced, hybrid therapy has been applied for the extended arch aneurysm. From 1997 to 2013, 379 patients have undergone aortic arch surgery. Of those, 241 patients of non-dissection aneurysm were studied. Open surgical repair with L-shaped thoracotomy was done in 28 patients, frozen elephant trunk( FET) in 30 patients, long elephant trunk( LET) with 2nd TEVAR in 21 patients, debranched TEVAR in 10 patients and standard arch grafting in 152 patients as a control group. The brain infarction rate was high in debranched TEVAR (40%) and L-shaped group (25%). The paraplegia rate was high in FET group( 23.3%). The respiratory failure rate was high in the L-shaped group and the LET group. In-hospital mortality was 0.0% in the L-shaped group, 6.7% in the FET group, 4.8% in the LET group, 20% in the debranched group and 0.7% in the control group. The debranched TEVAR group is our early experience, and the recent outcomes of this procedure have improved. The management of extended aortic arch aneurysm has changed with hybrid approach combined with TEVAR. Open repair is still the gold standard, but hybrid therapy is used for high-risk patients. Off-pump debranched TEVAR tends to be applied for extended arch aneurysm.
- 1 September 2013
- Vol. 66 (10) , 876-81
[Association of lung volume with shunt size in Starnes' procedure in neonates with severe Ebstein's anomaly].
Our modification of Starnes' procedure reduces right ventricular volume using only "suture plication" to improve surgical outcomes. However, shunt size in the procedure varies widely between patients. As this may be related to small lung volume, we estimated lung volume in each patient using computed tomography (CT).Since 2007, we have performed Starnes' procedure in 4 patients. Preoperative cardiothoracic ratio was 89±4.5%. Age and body weight at operation were 4.3±2.6 days and 2.6±0.2 kg, respectively. Anatomic slices 3 mm thick were acquired in transverse planes by CT. Total lung volume was calculated by accumulating those slices. Total lung volume and lung volume/body weight were 97.2±34.1 ml, 36.8±11.5 ml/kg, respectively. In one patient, a 3 mm prosthetic graft was needed to place a clip to regulate blood flow. Another patient required an additional shunt. The patient with the smallest lung volume required treatment with an extracorporeal lung-assistance device. Chest X-rays of neonates with severe Ebstein's anomaly usually show a "wall-to-wall" heart. However, lung volume varies widely between patients. Estimation of lung volume using CT is useful. In patients with smaller lung volume, a larger shunt than usual may be required to obtain the necessary pulmonary blood flow.
- 1 September 2013
- Vol. 66 (10) , 876-81
[Association of lung volume with shunt size in Starnes' procedure in neonates with severe Ebstein's anomaly].
Our modification of Starnes' procedure reduces right ventricular volume using only "suture plication" to improve surgical outcomes. However, shunt size in the procedure varies widely between patients. As this may be related to small lung volume, we estimated lung volume in each patient using computed tomography (CT).Since 2007, we have performed Starnes' procedure in 4 patients. Preoperative cardiothoracic ratio was 89±4.5%. Age and body weight at operation were 4.3±2.6 days and 2.6±0.2 kg, respectively. Anatomic slices 3 mm thick were acquired in transverse planes by CT. Total lung volume was calculated by accumulating those slices. Total lung volume and lung volume/body weight were 97.2±34.1 ml, 36.8±11.5 ml/kg, respectively. In one patient, a 3 mm prosthetic graft was needed to place a clip to regulate blood flow. Another patient required an additional shunt. The patient with the smallest lung volume required treatment with an extracorporeal lung-assistance device. Chest X-rays of neonates with severe Ebstein's anomaly usually show a "wall-to-wall" heart. However, lung volume varies widely between patients. Estimation of lung volume using CT is useful. In patients with smaller lung volume, a larger shunt than usual may be required to obtain the necessary pulmonary blood flow.
- 1 January 2013
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 95 (1) , 345-346
Spontaneous Disappearance of a Saphenous Vein Graft Pseudoaneurysm After Coronary Artery Bypass Grafting
- 1 January 2013
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 95 (1) , 345-346
Spontaneous Disappearance of a Saphenous Vein Graft Pseudoaneurysm After Coronary Artery Bypass Grafting
- 1 April 2012
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 143 (4) , 976-978
Aortocarotid bypass at the time of central aortic repair for type A acute aortic dissections
- 1 April 2012
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 143 (4) , 976-978
Aortocarotid bypass at the time of central aortic repair for type A acute aortic dissections
- 28 February 2012
- Published by Wolters Kluwer Health in Circulation
- Vol. 125 (8) , e389-91
Unruptured Left Coronary Sinus of Valsalva Aneurysm Causing Mitral Valve Obstruction
- 28 February 2012
- Published by Wolters Kluwer Health in Circulation
- Vol. 125 (8) , e389-91
Unruptured Left Coronary Sinus of Valsalva Aneurysm Causing Mitral Valve Obstruction
- 30 March 2011
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 59 (3) , 187-190
Retrograde coronary sinus cardioplegia cannula placement under short-time circulatory arrest in surgery for a ruptured type A dissection with a previous coronary artery bypass
A 79-year-old woman was referred to undergo surgery for a type A dissection. The patient had a history of previous coronary artery bypass. She was in shock and had a hematoma surrounding the ascending aorta and the heart. In this case, a coronary sinus cardioplegia cannula was placed under a short period of circulatory arrest via a small atriotomy, and the atriotomy was closed immediately to establish selective cerebral perfusion.
- 30 March 2011
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 59 (3) , 187-190
Retrograde coronary sinus cardioplegia cannula placement under short-time circulatory arrest in surgery for a ruptured type A dissection with a previous coronary artery bypass
A 79-year-old woman was referred to undergo surgery for a type A dissection. The patient had a history of previous coronary artery bypass. She was in shock and had a hematoma surrounding the ascending aorta and the heart. In this case, a coronary sinus cardioplegia cannula was placed under a short period of circulatory arrest via a small atriotomy, and the atriotomy was closed immediately to establish selective cerebral perfusion.