Daniellys Alejo Sánchez

Daniellys Alejo Sánchez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniellys Alejo Sánchez has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Benchmarking Low-Cost Particulate Matter Sensors: Evaluating Performance Under Controlled Environmental Conditions Using Low-Cost Experimental Setups

    by Arianna Alvarez Cruz, Olivier Schalm, Luis Ernesto Morera Hernández, Alain Martínez Laguardia, Daniellys Alejo Sánchez, Mayra C. Morales Pérez, Rosa Amalia González Rivero, Yasser Morera Gómez

    Particulate matter (PM) is widely recognized as a major air pollutant with significant impacts on human health, highlighting the need for accurate monitoring. In developing countries, low-cost sensors are crucial for accessible PM monitoring, but their accuracy and reliability must first be assessed. This study benchmarked the Alphasense OPC-N3 and Next PM sensors through laboratory and field evaluations. Laboratory tests were performed in controlled conditions with HEPA-filtered air at low humidity and varying concentrations of water droplets from nebulized deionized water. A 27-day field study in Cienfuegos, Cuba, provided additional insights into real-world performance. The OPC-N3 showed susceptibility to perturbations and was more affected by outliers (especially PM10), relative humidity, and interference from aqueous aerosols. In contrast, the Next PM sensor demonstrated superior stability, lower noise levels, and consistent performance across different environmental conditions. Despite a substantial price difference, both sensors provided valid measurements. Additionally, both sensors produced lognormal PM concentration distributions during field campaigns. This feature could aid in addressing the calibration stability challenges commonly associated with low-cost sensors through in situ calibration methods. While the PM measurements by affordable sensors are not perfect, they are sufficiently reliable for supporting air quality assessments in resource-limited settings.


  • Open Access

    Enhancing the Reliability of NO2 Monitoring Using Low-Cost Sensors by Compensating for Temperature and Humidity Effects

    by Daniellys Alejo Sánchez, Olivier Schalm, Arianna Álvarez Cruz, Erik Hernández Rodríguez, Alain Martínez Laguardia, David Kairuz Cabrera, Mayra C. Morales Pérez

    The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower, or cooling packs, while relative humidity was adjusted using glycerine solutions. Findings indicated that the auxiliary electrode signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the working electrode signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the auxiliary electrode signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability in the zero air calibration.


  • Open Access

    Enhancing the Reliability of NO2 Monitoring Using Low-Cost Sensors by Compensating for Temperature and Humidity Effects

    by Daniellys Alejo-Sánchez, Olivier Schalm, Arianna Álvarez-Cruz, Erik Hernández-Rodríguez, Alain Martínez-Laguardia, David Kairuz-Cabrera, Mayra C. Morales-Pérez

    The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower or cooling packs, while relative humidity was adjusted using glycerin solutions. Findings indicated that the Auxiliary Electrode (AE) signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the Working Electrode (WE) signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the AE signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability of the zero calibration.


  • Open Access

    Development of a Unified IoT Platform for Assessing Meteorological and Air Quality Data in a Tropical Environment

    by David Kairuz-Cabrera, Victor Hernandez-Rodriguez, Olivier Schalm, Alain Martinez, Pedro Merino Laso, Daniellys Alejo-Sánchez

    In developing nations, outdated technologies and sulfur-rich heavy fossil fuel usage are major contributors to air pollution, affecting urban air quality and public health. In addition, the limited resources hinder the adoption of advanced monitoring systems crucial for informed public health policies. This study addresses this challenge by introducing an affordable internet of things (IoT) monitoring system capable of tracking atmospheric pollutants and meteorological parameters. The IoT platform combines a Bresser 5-in-1 weather station with a previously developed air quality monitoring device equipped with Alphasense gas sensors. Utilizing MQTT, Node-RED, InfluxDB, and Grafana, a Raspberry Pi collects, processes, and visualizes the data it receives from the measuring device by LoRa. To validate system performance, a 15-day field campaign was conducted in Santa Clara, Cuba, using a Libelium Smart Environment Pro as a reference. The system, with a development cost several times lower than Libelium and measuring a greater number of variables, provided reliable data to address air quality issues and support health-related decision making, overcoming resource and budget constraints. The results showed that the IoT architecture has the capacity to process measurements in tropical conditions. The meteorological data provide deeper insights into events of poorer air quality.


  • Open Access

    Reliability Testing of a Low-Cost, Multi-Purpose Arduino-Based Data Logger Deployed in Several Applications Such as Outdoor Air Quality, Human Activity, Motion, and Exhaust Gas Monitoring

    by Erik Hernández-Rodríguez, Rosa Amalia González-Rivero, Olivier Schalm, Alain Martínez, Luis Hernández, Daniellys Alejo-Sánchez, Tim Janssens, Werner Jacobs

    This contribution shows the possibilities of applying a low-cost, multi-purpose data logger built around an Arduino Mega 2560 single-board computer. Most projects use this kind of hardware to develop single-purpose data loggers. In this work, a data logger with a more general hardware and software architecture was built to perform measurement campaigns in very different domains. The wide applicability of this data logger was demonstrated with short-term monitoring campaigns in relation to outdoor air quality, human activity in an office, motion of a journey on a bike, and exhaust gas monitoring of a diesel generator. In addition, an assessment process and corresponding evaluation framework are proposed to assess the credibility of low-cost scientific devices built in-house. The experiences acquired during the development of the system and the short measurement campaigns were used as inputs in the assessment process. The assessment showed that the system scores positively on most product-related targets. However, unexpected events affect the assessment over the longer term. This makes the development of low-cost scientific devices harder than expected. To assure stability and long-term performance of this type of design, continuous evaluation and regular engineering corrections are needed throughout longer testing periods.


  • Open Access

    Reliability Testing of a Low-Cost Arduino-Based Multipurpose Data Logger Deployed in Several Applications Such as Outdoor Air Quality, Human Activity, Motion and Exhaust Gas Monitoring

    by Erik Hernández Rodríguez, Rosa Amalia González Rivero, Olivier Schalm, Alain Laguardia Martínez, Luis Hernández Santana, Daniellys Alejo Sánchez, Tim Janssens, Werner Jacobs

    This contribution shows the possibilities of a low-cost multipurpose data logger that was built around an Arduino Mega 2560 single board computer. To transform the Arduino Mega into such a data logger, a sensor shield was designed that contains an SD-card, real-time clock, and different kinds of connectors so that sensors can easily be attached to the device. The software considers a wide range of predefined sensors from which a user can choose. To assess the performance of such a device, short-term monitoring campaigns in relation to outdoor air quality, human activity in an office, motion of a journey on a bike, and exhaust gas monitoring of a diesel generator were realized. Besides the possibilities to apply the data logger in different kinds of applications, a method is proposed to assess the credibility of such a system. The assessment based on the various short-term campaigns showed that the system scores positively on most of the performance indicators, but that unexpected (black swan) events affect the assessment over the longer term. This makes the development of low-cost scientific instruments harder than expected. The stability and long-term performance of this type of design requires continuous evaluation and engineering correction.


  • Open Access

    Relevance and Reliability of Outdoor SO2 Monitoring in Low-Income Countries Using Low-Cost Sensors

    by Rosa Amalia González Rivero, Olivier Schalm, Arianna Alvarez Cruz, Erik Hernández Rodríguez, Mayra C. Morales Pérez, Daniellys Alejo Sánchez, Alain Martinez Laguardia, Werner Jacobs, Luis Hernández Santana

    In the Western world, the SO2 concentration in ambient air dropped to low levels, but some emission sources (e.g., merchant ships) and some regions (e.g., low-income countries) still emit substantial amounts of SO2. At those locations, SO2 monitoring is critical. However, low-income countries do not have much access to expensive reference instruments. Low-cost gas sensors might be an alternative, but it is unclear how reliable such measurements are. To evaluate the performance of the low-cost alternative, the same SO2 gas sensor has been subjected to three different calibration methods: (1) low-cost calibration performed in the tropical climate of Cuba; (2) high-end calibration performed in Belgium; (3) a field calibration at an air quality measuring station in Belgium. The first two methods showed similar trends, suggesting that the gas sensor can be calibrated with a low-cost method. The field calibration was hampered by the low SO2 concentrations. For the monitoring campaign in Cienfuegos, Cuba, the low-cost SO2 sensor calibrated by the low-cost method appeared to be sufficiently reliable. The reliability of the sensor increases with the increase in SO2 concentration, so it can be used in Cuba instead of Belgium.


  • Open Access

    A Low-Cost Calibration Method for Temperature, Relative Humidity, and Carbon Dioxide Sensors Used in Air Quality Monitoring Systems

    by Rosa Amalia González Rivero, Luis Ernesto Morera Hernández, Olivier Schalm, Erik Hernández Rodríguez, Daniellys Alejo Sánchez, Mayra C. Morales Pérez, Vladimir Nuñez Caraballo, Werner Jacobs, Alain Martinez Laguardia

    Low-cost sensors provide an affordable alternative to monitor environmental parameters with acceptable performance. There is a substantial amount of literature where low-cost sensors are compared with high-end reference measurements. However, not all organizations have access to such reference infrastructure. We propose low-cost calibration methods for temperature, relative humidity, and CO2 to allow them to collect their own reliable data. These methods are based on simple techniques and procedures that allow temperature calibration to be achieved in the range of 0 to 50 °C, relative humidity from 0 to 90%, and CO2 between 0 and 1100 ppm. The materials used to create the calibration setups can be purchased online, at hardware stores, and in pharmacies. The reliability of the calibration methods was evaluated using several indicators, such as the airtightness of the calibration box, similarity with the factory calibration, similarity with the reference, similarity between different sensors, replicability of the calibration method, and the similarity with a golden standard. In addition, the results of the low-cost calibration methods were compared with the more advanced calibration methods. A short measurement campaign in the city of Santa Clara, Cuba, demonstrated that such calibrations transform in-house developed monitoring systems into valid low-cost scientific instruments for decision-making. This work creates opportunities for institutions and researchers hosted in low- and mid-income countries to build and validate their own equipment to reliably solve local problems.


  • Design of a Low-Cost System for the Measurement of Variables Associated With Air Quality

    by Alain Martinez, Erik Hernandez-Rodríguez, Luis Hernandez, Olivier Schalm, Rosa Amalia González-Rivero, Daniellys Alejo-Sánchez

    Poor air quality is a global problem that affects human health and ecosystems all over the world. For that reason, many countries invest in networks of reference monitoring stations that measure air quality in real time. However, the high installation and maintenance costs of these stations mean that smaller cities or underdeveloped regions are less covered by such stations. In these regions, alternative detection technologies such as low-cost monitoring systems can be used instead. Unfortunately, the results of such monitoring devices are often questioned by academics. This contribution proposes the design of an air quality monitoring system where cost and reliability have been optimized from a hardware point of view. In addition, the device has been coupled to an IoT platform so that inexperienced users can view and share the collected information The design of affordable systems increases the ability to perform ad hoc analysis at the level of neighborhoods or cities by citizen science organizations or governmental entities.


  • Seasonal trends of atmospheric nitrogen dioxide and sulfur dioxide over North Santa Clara, Cuba

    by Daniellys Alejo, Mayra C. Morales, Jorge B. de la Torre, Ricardo Grau, László Bencs, René Van Grieken, Piet Van Espen, Dismey Sosa, Vladimir Nuñez

    Atmospheric nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels were monitored simultaneously by means of Radiello passive samplers at six sites of Santa Clara city, Cuba, in the cold and the warm seasons in 2010. The dissolved ionic forms of NO2 and SO2 as nitrate and sulfite plus sulfate, respectively, were determined by means of ion chromatography. Analysis of NO2 as nitrite was also performed by UV–Vis spectrophotometry. For NO2, significant t tests show good agreement between the results of IC and UV–Vis methods. The NO2 and SO2 concentrations peaked in the cold season, while their minimum levels were experienced in the warm season. The pollutant levels do not exceed the maximum allowable limit of the Cuban Standard 39:1999, i.e., 40 μg/m3 and 50 μg/m3 for NO2 and SO2, respectively. The lowest pollutant concentrations obtained in the warm season can be attributed to an increase in their removal via precipitation (scavenging) while to the decreased traffic density and industrial emission during the summer holidays (e.g., July and August).