Arianna Alvarez Cruz

Arianna Alvarez Cruz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arianna Alvarez Cruz has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Benchmarking Low-Cost Particulate Matter Sensors: Evaluating Performance Under Controlled Environmental Conditions Using Low-Cost Experimental Setups

    by Arianna Alvarez Cruz, Olivier Schalm, Luis Ernesto Morera Hernández, Alain Martínez Laguardia, Daniellys Alejo Sánchez, Mayra C. Morales Pérez, Rosa Amalia González Rivero, Yasser Morera Gómez

    Particulate matter (PM) is widely recognized as a major air pollutant with significant impacts on human health, highlighting the need for accurate monitoring. In developing countries, low-cost sensors are crucial for accessible PM monitoring, but their accuracy and reliability must first be assessed. This study benchmarked the Alphasense OPC-N3 and Next PM sensors through laboratory and field evaluations. Laboratory tests were performed in controlled conditions with HEPA-filtered air at low humidity and varying concentrations of water droplets from nebulized deionized water. A 27-day field study in Cienfuegos, Cuba, provided additional insights into real-world performance. The OPC-N3 showed susceptibility to perturbations and was more affected by outliers (especially PM10), relative humidity, and interference from aqueous aerosols. In contrast, the Next PM sensor demonstrated superior stability, lower noise levels, and consistent performance across different environmental conditions. Despite a substantial price difference, both sensors provided valid measurements. Additionally, both sensors produced lognormal PM concentration distributions during field campaigns. This feature could aid in addressing the calibration stability challenges commonly associated with low-cost sensors through in situ calibration methods. While the PM measurements by affordable sensors are not perfect, they are sufficiently reliable for supporting air quality assessments in resource-limited settings.


  • Open Access

    Enhancing the Reliability of NO2 Monitoring Using Low-Cost Sensors by Compensating for Temperature and Humidity Effects

    by Daniellys Alejo Sánchez, Olivier Schalm, Arianna Álvarez Cruz, Erik Hernández Rodríguez, Alain Martínez Laguardia, David Kairuz Cabrera, Mayra C. Morales Pérez

    The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower, or cooling packs, while relative humidity was adjusted using glycerine solutions. Findings indicated that the auxiliary electrode signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the working electrode signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the auxiliary electrode signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability in the zero air calibration.


  • Open Access

    Enhancing the Reliability of NO2 Monitoring Using Low-Cost Sensors by Compensating for Temperature and Humidity Effects

    by Daniellys Alejo-Sánchez, Olivier Schalm, Arianna Álvarez-Cruz, Erik Hernández-Rodríguez, Alain Martínez-Laguardia, David Kairuz-Cabrera, Mayra C. Morales-Pérez

    The study investigates methods to enhance the reliability of NO2 monitoring using low-cost electrochemical sensors to measure gaseous pollutants in air by addressing the impacts of temperature and relative humidity. The temperature within a plastic container was controlled using an internal mica heater, an external hot air blower or cooling packs, while relative humidity was adjusted using glycerin solutions. Findings indicated that the Auxiliary Electrode (AE) signal is susceptible to temperature and moderately affected by relative humidity. In contrast, the Working Electrode (WE) signal is less affected by temperature and relative humidity; however, adjustments are still required to determine gas concentrations accurately. Tests involving on/off cycles showed that the AE signal experiences exponential decay before stabilizing, requiring the exclusion of initial readings during monitoring activities. Additionally, calibration experiments in zero air allowed the determination of the compensation factor nT across different temperatures and humidity levels. These results highlight the importance of compensating for temperature and humidity effects to improve the accuracy and reliability of NO2 measurements using low-cost electrochemical sensors. This refinement makes the calibration applicable across a broader range of environmental conditions. However, the experiments also show a lack of repeatability of the zero calibration.


  • Open Access

    Sulfure dioxide EXPERIMENTAL ASSESSMENT OF SULFURE DIOXIDE REMOVAL FROM GAS STREAM FOR INTENSIVE ALGAE CULTURE

    by Liset Roche Delgado, Mayra Caridad Morales Perez, Rosa Amalia González Rivero, Arianna Álvarez Cruz, Agustín Andrés García Rodríguez, Juan Pedro Hernández Touset

    In this research, several SO2 removal alternatives were evaluated for the treatment of gaseous effluents generated by the "Carlos Manuel de Céspedes" power plant in Cienfuegos to be use in gaseous stream to Ulva lettuce intensive culture. A low-cost sensor was used to monitor the gas concentration during the proposed methods. The sensor was previously calibrated and a linear regression model with a coefficient of determination of 0,9926 was obtained. The alternatives evaluated were adsorption with activated carbon, absorption with calcium hydroxide and absorption with seawater. The removal was evaluated at three levels SO2 concentration. In addition, the parameters pH, salinity and alkalinity were determined to a seawater sample from the Bay of Cienfuegos and with which the experiments were carried out. The values obtained were 8,17±0,003; 26,50±0,10 ups and 171,67±1,03 mg/L respectively, which confirms its good performance for gas removal. The three methods studied showed satisfactory results for SO2 removal. The seawater absorption experiment was the most efficient alternative, achieving the lowest final concentrations in the shortest time. En esta investigación se evaluaron varias alternativas de remoción de SO2 para el tratamiento de los efluentes gaseosos generados por la central termoeléctrica «Carlos Manuel de Céspedes» de Cienfuegos para su uso en corriente gaseosa al cultivo intensivo de la lechuga Ulva. Se utilizó un sensor de bajo costo para monitorear la concentración de gases durante los métodos propuestos. El sensor fue previamente calibrado y se obtuvo un modelo de regresión lineal con un coeficiente de determinación de 0,9926. Las alternativas evaluadas fueron adsorción con carbón activado, absorción con hidróxido de calcio y absorción con agua de mar. La eliminación se evaluó a tres niveles de concentración de SO2. Además, se determinaron los parámetros pH, salinidad y alcalinidad a una muestra de agua de mar procedente de la Bahía de Cienfuegos y con la cual se realizaron los experimentos. Los valores obtenidos fueron 8,17±0,003; 26,50±0,10 ups y 171,67±1,03 mg/L respectivamente, lo que confirma su buen desempeño para la remoción de gases. Los tres métodos estudiados mostraron resultados satisfactorios para la eliminación de SO2. El experimento de absorción en agua de mar fue la alternativa más eficiente, alcanzando las concentraciones finales más bajas en el menor tiempo. Nesta investigação, foram avaliadas várias alternativas de remoção de SO2 para o tratamento de efluentes gasosos gerados pela central eléctrica “Carlos Manuel de Céspedes”, em Cienfuegos, para serem utilizados em fluxo gasoso para a cultura intensiva de alface Ulva. Foi utilizado um sensor de baixo custo para monitorizar a concentração de gás durante os métodos propostos. O sensor foi previamente calibrado e obteve-se um modelo de regressão linear com um coeficiente de determinação de 0,9926. As alternativas avaliadas foram adsorção com carvão ativado, absorção com hidróxido de cálcio e absorção com água do mar. A remoção foi avaliada em três níveis de concentração de SO2. Além disso, foram determinados os parâmetros pH, salinidade e alcalinidade a uma amostra de água do mar da Baía de Cienfuegos com a qual se realizaram as experiências. Os valores obtidos foram de 8,17±0,003; 26,50±0,10 ups e 171,67±1,03 mg/L respetivamente, o que confirma o seu bom desempenho na remoção de gases. Os três métodos estudados apresentaram resultados satisfatórios para a remoção de SO2. O experimento de absorção com água do mar foi a alternativa mais eficiente, alcançando as menores concentrações finais no menor tempo.

  • Open Access

    Relevance and Reliability of Outdoor SO2 Monitoring in Low-Income Countries Using Low-Cost Sensors

    by Rosa Amalia González Rivero, Olivier Schalm, Arianna Alvarez Cruz, Erik Hernández Rodríguez, Mayra C. Morales Pérez, Daniellys Alejo Sánchez, Alain Martinez Laguardia, Werner Jacobs, Luis Hernández Santana

    In the Western world, the SO2 concentration in ambient air dropped to low levels, but some emission sources (e.g., merchant ships) and some regions (e.g., low-income countries) still emit substantial amounts of SO2. At those locations, SO2 monitoring is critical. However, low-income countries do not have much access to expensive reference instruments. Low-cost gas sensors might be an alternative, but it is unclear how reliable such measurements are. To evaluate the performance of the low-cost alternative, the same SO2 gas sensor has been subjected to three different calibration methods: (1) low-cost calibration performed in the tropical climate of Cuba; (2) high-end calibration performed in Belgium; (3) a field calibration at an air quality measuring station in Belgium. The first two methods showed similar trends, suggesting that the gas sensor can be calibrated with a low-cost method. The field calibration was hampered by the low SO2 concentrations. For the monitoring campaign in Cienfuegos, Cuba, the low-cost SO2 sensor calibrated by the low-cost method appeared to be sufficiently reliable. The reliability of the sensor increases with the increase in SO2 concentration, so it can be used in Cuba instead of Belgium.