Tobias Brendel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Tobias Brendel has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Ralf Brinkmann
T. Brendelis at Brunnenstrasse 15/8, 55120 Mainz, Germany.R. Brinkmannis with the Medical Laser Center Luebeck, Peter-Monnik-Weg 4, 23562 Luebeck, Germany
1 shared publication
Latest Publications
- 19 March 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (9) , 1856-1862
Mid-infrared laser-induced superheating of water and its quantification by an optical temperature probe.
Free-running thulium laser pulses (Cr:Tm:YAG, λ = 2.01 μm, t p = 300 μs) were applied to a purified, degassed water sample and the resulting temperature rise was investigated by an optical temperature probe. The probe detected water reflectance index changes with temperature and also the onset of vaporization, which was found to occur in a superheat regime, at approximately 230 °C. The experimental data were compared with theoretical temperature calculations, and deviations of less than 20 °C were stated. The best agreement between theory and experiment was found for temperatures below 180 °C, defining by this the method’s high accuracy limit. In conclusion, both the optical temperature probe and the presented calculations can help to improve dosimetry in pulsed IR laser applications by precise temperature measurement and prediction.
- 19 March 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (9) , 1856-1862
Mid-infrared laser-induced superheating of water and its quantification by an optical temperature probe.
Free-running thulium laser pulses (Cr:Tm:YAG, λ = 2.01 μm, t p = 300 μs) were applied to a purified, degassed water sample and the resulting temperature rise was investigated by an optical temperature probe. The probe detected water reflectance index changes with temperature and also the onset of vaporization, which was found to occur in a superheat regime, at approximately 230 °C. The experimental data were compared with theoretical temperature calculations, and deviations of less than 20 °C were stated. The best agreement between theory and experiment was found for temperatures below 180 °C, defining by this the method’s high accuracy limit. In conclusion, both the optical temperature probe and the presented calculations can help to improve dosimetry in pulsed IR laser applications by precise temperature measurement and prediction.