Shrikrishna V. Kulkarni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shrikrishna V. Kulkarni has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Boggavarapu Sai Ram
Department of Electrical, Electronics and Communication Engineering, Indian Institute of Technology Dharwad, Dharwad, India
5 shared publications - Greeshma Mohan Unniachanparambil
Department of Electrical Engineering, IIT Bombay, Mumbai, India
5 shared publications - Ashish Prakash Agalgaonkar
The Australian Power and Energy Research Institute, University of Wollongong, Wollongong, NSW 2522, Australia
3 shared publications - G. B. Kumbhar
Research Scholar, Department of Electrical Engineering, Indian Institute of Technology-Bombay, Mumbai-400076, India
3 shared publications - Krishna Kanakgiri
Department of Electrical Engineering, IIT Bombay, Mumbai, India
3 shared publications - Sarath Perera
Australian Power Quality Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
3 shared publications
Latest Publications
- 2 March 2026
- Published by Elsevier in Solar Energy
- Vol. 309
Predicting leakage currents in photovoltaic modules using a spatio-temporal transient model
- 2 March 2026
- Published by Elsevier in Solar Energy
- Vol. 309
Predicting leakage currents in photovoltaic modules using a spatio-temporal transient model
- 27 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1020-1031
A Hybrid Multi-Criteria Decision-Making Based Fuzzy System for Comprehensive Health Assessment of Power Transformers
Precise evaluation of transformer health using well-structured asset management methodologies is essential, and over the last two decades, several health assessment methods have been developed based on various diagnostic tests. However, the literature on methods to ensure a comprehensive health evaluation with a focus on prioritized correlation analysis is limited. In this context, this work proposes a framework for evaluating the performance of power transformers using 15 diagnostic attributes. The model is designed with Analytical Hierarchy Process (AHP), Grey Relational Analysis (GRA), and Technique for Order Performance by Similarity to Ideal Solution (TOPSIS). The diagnostic attributes are initially normalized, and then prioritized based on closely related characteristics and finally grouped into three specific health degrees using the proposed systematic hybrid decision-making approach. The three health degrees are further coupled with a technical fuzzy rule base to derive the actual health status of power transformers. The hybrid model is validated using known health conditions of 200 transformers collected from Himachal Pradesh State Electricity Board, India, and compared with recent similar health prediction methods published in the literature. The comparison reveals the superiority of the model with 97% accuracy. Moreover, the following are the main advantages of the model over the existing health assessment methods: prioritization among closely related attributes, assessment of samples with respect to positive and negative ideal solutions, no dependency on training data, less complexity, and consideration of visual inspection and maintenance parameters. Furthermore, it facilitates an appropriate alert system for conditional maintenance.
- 27 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1020-1031
A Hybrid Multi-Criteria Decision-Making Based Fuzzy System for Comprehensive Health Assessment of Power Transformers
Precise evaluation of transformer health using well-structured asset management methodologies is essential, and over the last two decades, several health assessment methods have been developed based on various diagnostic tests. However, the literature on methods to ensure a comprehensive health evaluation with a focus on prioritized correlation analysis is limited. In this context, this work proposes a framework for evaluating the performance of power transformers using 15 diagnostic attributes. The model is designed with Analytical Hierarchy Process (AHP), Grey Relational Analysis (GRA), and Technique for Order Performance by Similarity to Ideal Solution (TOPSIS). The diagnostic attributes are initially normalized, and then prioritized based on closely related characteristics and finally grouped into three specific health degrees using the proposed systematic hybrid decision-making approach. The three health degrees are further coupled with a technical fuzzy rule base to derive the actual health status of power transformers. The hybrid model is validated using known health conditions of 200 transformers collected from Himachal Pradesh State Electricity Board, India, and compared with recent similar health prediction methods published in the literature. The comparison reveals the superiority of the model with 97% accuracy. Moreover, the following are the main advantages of the model over the existing health assessment methods: prioritization among closely related attributes, assessment of samples with respect to positive and negative ideal solutions, no dependency on training data, less complexity, and consideration of visual inspection and maintenance parameters. Furthermore, it facilitates an appropriate alert system for conditional maintenance.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (10) , 1-7
A Circuit-Based Formulation for Soft Magnetic Materials Using the Jiles–Atherton Model
It is crucial to accurately estimate the performance of magnetic components like inductors and transformers during their predesign stage. The magnetic characteristics of soft magnetic materials are significantly affected by their excitation. For example, a time-varying excitation results in dynamic losses (eddy and excess loss components) and an excitation with harmonics leads to extra losses. To accurately model these components with a generalized approach, it is important to consider a physics-based hysteresis formulation in electromagnetic analysis. Some circuit and electromagnetic field simulators can model hysteresis characteristics using formulations like the Jiles-Atherton (JA) hysteresis model. However, these simulators require the JA model parameters as input, and it is a challenge for simulation engineers to calculate the JA model parameters. In this work, an inductor circuit element is proposed using the JA model to define the magnetic characteristics of soft magnetic materials in an open-source circuit simulator. Providing hysteresis (or B-H loop) data as input to the circuit element in the proposed approach obviates the need of calculating the JA model parameters for circuit simulation. The B-H data is used to determine the JA model parameters, which are automatically transferred to the inductor model in the circuit simulation. The approach can be used to model the topological-based equivalent circuit of magnetic components like inductors and transformers.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (10) , 1-7
A Circuit-Based Formulation for Soft Magnetic Materials Using the Jiles–Atherton Model
It is crucial to accurately estimate the performance of magnetic components like inductors and transformers during their predesign stage. The magnetic characteristics of soft magnetic materials are significantly affected by their excitation. For example, a time-varying excitation results in dynamic losses (eddy and excess loss components) and an excitation with harmonics leads to extra losses. To accurately model these components with a generalized approach, it is important to consider a physics-based hysteresis formulation in electromagnetic analysis. Some circuit and electromagnetic field simulators can model hysteresis characteristics using formulations like the Jiles-Atherton (JA) hysteresis model. However, these simulators require the JA model parameters as input, and it is a challenge for simulation engineers to calculate the JA model parameters. In this work, an inductor circuit element is proposed using the JA model to define the magnetic characteristics of soft magnetic materials in an open-source circuit simulator. Providing hysteresis (or B-H loop) data as input to the circuit element in the proposed approach obviates the need of calculating the JA model parameters for circuit simulation. The B-H data is used to determine the JA model parameters, which are automatically transferred to the inductor model in the circuit simulation. The approach can be used to model the topological-based equivalent circuit of magnetic components like inductors and transformers.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (10) , 1-8
A Modified Takács Model to Formulate the Anisotropic Behavior of Grain-Oriented Laminations
It is essential to consider the anisotropic behaviour of soft magnetic materials to accurately estimate the core losses in the machine parts, wherein the direction of the magnetic field is a function of time and space. At T joints of transformers and tooth-yoke joints of rotating machines, the direction of magnetic fields changes as a function of time. Directional dependency of magnetic properties result in additional losses. Various formulations to model the anisotropic behaviour of hysteresis characteristics and corresponding losses of soft-magnetic materials are available in the literature. The Takács model is a computationally efficient mathematical formulation to model the hysteresis behaviour. In this work, an analytical extension to the Takács model is proposed to formulate the anisotropic behaviour of these materials. The variation of the model parameters with direction is studied, and their directional dependencies are formulated using suitable functions. The anisotropic behaviour of the grain-oriented (GO) materials along arbitrary directions is investigated using the proposed approach and it is found to be in agreement with measurements. This model can be used to formulate the complicated magnetic behaviour at joints in transformers and electrical machines.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (10) , 1-8
A Modified Takács Model to Formulate the Anisotropic Behavior of Grain-Oriented Laminations
It is essential to consider the anisotropic behaviour of soft magnetic materials to accurately estimate the core losses in the machine parts, wherein the direction of the magnetic field is a function of time and space. At T joints of transformers and tooth-yoke joints of rotating machines, the direction of magnetic fields changes as a function of time. Directional dependency of magnetic properties result in additional losses. Various formulations to model the anisotropic behaviour of hysteresis characteristics and corresponding losses of soft-magnetic materials are available in the literature. The Takács model is a computationally efficient mathematical formulation to model the hysteresis behaviour. In this work, an analytical extension to the Takács model is proposed to formulate the anisotropic behaviour of these materials. The variation of the model parameters with direction is studied, and their directional dependencies are formulated using suitable functions. The anisotropic behaviour of the grain-oriented (GO) materials along arbitrary directions is investigated using the proposed approach and it is found to be in agreement with measurements. This model can be used to formulate the complicated magnetic behaviour at joints in transformers and electrical machines.
- Open Access
- 11 March 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 8
Review of coupled inductors in power electronics: From concept to practice
- 11 March 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 8
Open AccessReview of coupled inductors in power electronics: From concept to practice
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Comparison of Dynamic Loss Inclusion Under Asymmetrical Minor Loops Using Lavers Formula and Inverse Jiles–Atherton Model
Predicting core loss and dynamic magnetization of soft magnetic materials for arbitrary excitations is crucial under high harmonic content. The dynamic losses for non-sinusoidal excitation evaluated using the Lavers’ formula and inverse Jiles-Atherton (JA) model are compared. The modeling of hysteresis curves with minor loops using the JA model is achieved by predicting three components of the magnetic field strength based on the field separation approach. The flux variation due to minor loops is considered by following the magnetic flux density in time using eddy current and excess field terms. The dynamic extension of the JA model to represent asymmetrical minor loops using the field separation approach is presented. The proposed method seems promising for use in finite element method (FEM) simulations for predicting iron losses in electromagnetic design problems involving power electronic converters.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Comparison of Dynamic Loss Inclusion Under Asymmetrical Minor Loops Using Lavers Formula and Inverse Jiles–Atherton Model
Predicting core loss and dynamic magnetization of soft magnetic materials for arbitrary excitations is crucial under high harmonic content. The dynamic losses for non-sinusoidal excitation evaluated using the Lavers’ formula and inverse Jiles-Atherton (JA) model are compared. The modeling of hysteresis curves with minor loops using the JA model is achieved by predicting three components of the magnetic field strength based on the field separation approach. The flux variation due to minor loops is considered by following the magnetic flux density in time using eddy current and excess field terms. The dynamic extension of the JA model to represent asymmetrical minor loops using the field separation approach is presented. The proposed method seems promising for use in finite element method (FEM) simulations for predicting iron losses in electromagnetic design problems involving power electronic converters.
- 18 August 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 590, 171148
Influence of compressive stress on the magnetic characteristics of grain-oriented material under non-sinusoidal excitation
- 18 August 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 590, 171148
Influence of compressive stress on the magnetic characteristics of grain-oriented material under non-sinusoidal excitation
- 14 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 245-260
Chance-Constrained Pre-Contingency Joint Self- Scheduling of Energy and Reserve in VPP
With the increasing penetration of primarily inertia-less distributed energy resources, allowable delay in the fast frequency reserve provision to ensure marginal stability condition can become comparable with the requisite dead-time for fast-switching in a radial power distribution system (PDS) connected to the transmission system. Consequently, the prevailing short-duration load-generation imbalance might propagate as system-wide frequency excursion in the future power system, which traditionally has not been observed. Furthermore, during the fast-switching, some of the fast-acting reserve (FAR) providing local generators remain inaccessible to the bulk power system (BPS). This work has answered the questions of requisite reserve requirements to cater to such events through efficient energy and FAR provision joint-scheduling. Stochasticity of fast-switching, with temporary faults as a use-case, requires modeling of load-generation imbalance and local resource unavailability, vis-á-vis FAR requirement problem, as a chance-constraint. Due to the limited visibility at the BPS level, PDS operators must ensure sufficient FAR availability for a given confidence level of the chance-constraint. Individual chance-constraints are used to ensure mathematical simplicity. Here, the PDS is operated as a virtual power plant (VPP), where the operator can procure resources locally or from the wholesale market with the aim of profit maximization before the contingency occurs. Results show that FAR requirements can influence the local energy schedule and raise energy costs. Furthermore, the confidence level of the chance-constraint can impact overall profitability, and FAR should be scheduled carefully. Comparative analysis with a modified benchmark IEEE 33-node radial test system and a 98-node test system shows the superior performance of the proposed approach. The impact of the limited available FAR is also demonstrated.
- 14 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 245-260
Chance-Constrained Pre-Contingency Joint Self- Scheduling of Energy and Reserve in VPP
With the increasing penetration of primarily inertia-less distributed energy resources, allowable delay in the fast frequency reserve provision to ensure marginal stability condition can become comparable with the requisite dead-time for fast-switching in a radial power distribution system (PDS) connected to the transmission system. Consequently, the prevailing short-duration load-generation imbalance might propagate as system-wide frequency excursion in the future power system, which traditionally has not been observed. Furthermore, during the fast-switching, some of the fast-acting reserve (FAR) providing local generators remain inaccessible to the bulk power system (BPS). This work has answered the questions of requisite reserve requirements to cater to such events through efficient energy and FAR provision joint-scheduling. Stochasticity of fast-switching, with temporary faults as a use-case, requires modeling of load-generation imbalance and local resource unavailability, vis-á-vis FAR requirement problem, as a chance-constraint. Due to the limited visibility at the BPS level, PDS operators must ensure sufficient FAR availability for a given confidence level of the chance-constraint. Individual chance-constraints are used to ensure mathematical simplicity. Here, the PDS is operated as a virtual power plant (VPP), where the operator can procure resources locally or from the wholesale market with the aim of profit maximization before the contingency occurs. Results show that FAR requirements can influence the local energy schedule and raise energy costs. Furthermore, the confidence level of the chance-constraint can impact overall profitability, and FAR should be scheduled carefully. Comparative analysis with a modified benchmark IEEE 33-node radial test system and a 98-node test system shows the superior performance of the proposed approach. The impact of the limited available FAR is also demonstrated.