Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


George P. Eppeldauer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Broadband radiometric LED measurements

    by G. P. Eppeldauer, C. C. Cooksey, H. W. Yoon, L. M. Hanssen, V. B. Podobedov, R. E. Vest, U. Arp, C. C. Miller

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.


  • Development of an in situ calibration method for current-to-voltage converters for high-accuracy SI-traceable low dc current measurements

    by George P Eppeldauer, Howard W Yoon, Dean G Jarrett, Thomas C Larason

    For photocurrent measurements with low uncertainties, wide dynamic range reference current-to-voltage converters and a new converter calibration method have been developed at the National Institute of Standards and Technology (NIST). The high-feedback resistors of a reference converter were in situ calibrated on a high-resistivity, printed circuit board placed in an electrically shielded box electrically isolated from the operational amplifier using jumpers. The feedback resistors, prior to their installation, were characterized, selected and heat treated. The circuit board was cleaned with solvents, and the in situ resistors were calibrated using measurement systems for 10 kΩ to 10 GΩ standard resistors. We demonstrate that dc currents from 1 nA to 100 µA can be measured with uncertainties of 55 × 10−6 (k = 2) or lower, which are lower in uncertainties than any commercial device by factors of 10 to 30 at the same current setting. The internal (NIST) validations of the reference converter are described.


  • Spectral responsivity-based calibration of photometer and colorimeter standards

    by George P. Eppeldauer

    Several new generation transfer- and working-standard illuminance meters and tristimulus colorimeters have been developed at the National Institute of Standards and Technology (NIST) [1] Eppeldauer, G.P.; Miller, C.C.; Ohno, Y. In Proceedings of the 26th Session of the CIE, Vol. 1, Beijing, China, July 4–11, 2007; D2–99–D2-102; CIE Central Bureau: Vienna, Austria, 2007. [Google Scholar] to measure all kinds of light sources with low uncertainty. The spectral and broad-band (illuminance) responsivities of the photometer (Y) channels of two tristimulus meters were determined at both the Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) facility and the Spectral Comparator Facility (SCF) [2] Eppeldauer, G.P.; Miller, C.C.; Larason, T.C.; Ohno, Y. Presented at the CIE Light and Lighting Conference, Budapest, Hungary, May 27–29, 2009. [Google Scholar] . The two illuminance responsivities agreed within 0.1% with an overall uncertainty of 0.2% (k = 2), which is a factor of two improvement over the present NIST photometric scale. The first detector-based tristimulus color scale [3] Eppeldauer, G.P. J. Res. Natl. Inst. Stand. Technol. 1998, 103, 615–619. [Crossref], [Web of Science ®] [Google Scholar] was realized. All channels of the reference tristimulus colorimeter were calibrated at the SIRCUS. The other tristimulus meters were calibrated at the SCF and also against the reference meter on the photometry bench in broad-band measurement mode. The agreement between detector- and source-based calibrations was within 3 K when a tungsten lamp-standard was measured at 2856 K and 3100 K [4] Eppeldauer, G.P.; Miller, C.C.; Larason, T.C.; Ohno, Y. Presented at the CIE Tutorial and Expert Symposium on Spectral and Imaging Methods for Photometry and Radiometry, Bern, Switzerland, August 30–31, 2010. [Google Scholar] . The color–temperature uncertainty of tungsten lamp measurements was 4 K (k = 2) between 2300 K and 3200 K, which is a factor of two improvement over the presently used NIST source-based color temperature scale. One colorimeter was extended with an additional (fifth) channel to apply software implemented matrix corrections. With this correction, the spectral mismatch caused color difference errors were decreased by a factor of 20 for single-color LEDs.


  • Infrared spectral responsivity scale realization and validations

    by George P. Eppeldauer, Vyacheslav B. Podobedov

    An InSb working standard radiometer, first calibrated at the National Institute of Standards and Technology (NIST) in 1999 against a cryogenic bolometer, was recently calibrated against a newly developed low-noise-equivalent-power pyroelectric transfer standard detector. The pyroelectric transfer standard, which can operate at the output of a monochromator, holds the newly realized NIST spectral power responsivity scale between 1.7 and 14 μm with an uncertainty of 1% (k=2). The InSb working standard was also measured at the National Physical Laboratory (NPL) of the United Kingdom in 1999. The less than 2% spectral power responsivity disagreements obtained on the InSb working standard (both from the 1999 NIST and NPL comparison and also against the pyroelectric standard) validate the three independently realized power responsivity scales and verify the long-term stability of the InSb working standard. The InSb working standard was also used in irradiance measurement mode to validate the previously determined spectral irradiance responsivity of four narrowband InSb radiometers that were applied to calibrate IR target simulators. The uncertainty of the present spectral irradiance responsivity scale held by the InSb working standard is 2.5% (k=2) in the 2 to 5.2 μm wavelength range.


  • Standardization of Broadband UV Measurements for 365 nm LED Sources

    by George P. Eppeldauer

    Broadband UV measurements are evaluated when UV-A irradiance meters measure optical radiation from 365 nm UV sources. The CIE standardized rectangular-shape UV-A function can be realized only with large spectral mismatch errors. The spectral power-distribution of the 365 nm excitation source is not standardized. Accordingly, the readings made with different types of UV meters, even if they measure the same UV source, can be very different. Available UV detectors and UV meters were measured and evaluated for spectral responsivity. The spectral product of the source-distribution and the meter's spectral-responsivity were calculated for different combinations to estimate broad-band signal-measurement errors. Standardization of both the UV source-distribution and the meter spectral-responsivity is recommended here to perform uniform broad-band measurements with low uncertainty. It is shown what spectral responsivity function(s) is needed for new and existing UV irradiance meters to perform low-uncertainty broadband 365 nm measurements.


  • Short-wave infrared radiometers design and characterizations

    by George P. Eppeldauer, Howard W. Yoon

    Short-wave infrared (SW-IR) radiometers have been developed to extend the NIST reference responsivity scales from the silicon wavelength range to 2500 nm. In addition to spectral power responsivity measurements, where 5 mm diameter extended-InGaAs (EIGA) detectors are underfilled by the incident radiation, irradiance responsivity calibrations are needed. Irradiance measuring radiometers are used as reference detectors to calibrate field radiometers in both irradiance and radiance measurement modes. In irradiance mode, smaller detectors with high shunt resistance, such as 1 mm diameter short-wave HgCdTe and EIGA detectors are used. Mechanical, optical, thermal, and electronic design considerations of SW-IR radiometers are discussed. Noise equivalent currents (NEC) were measured to evaluate noise equivalent power (NEP) and D*.


  • Tristimulus Color Measurement of Self‐Luminous Sources

    by János Schanda, George Eppeldauer, Georg Sauter