TLThomas C. Larason

Thomas C. Larason

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas C. Larason has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improved ultraviolet measurement capabilities of NIST’s reference transmittance spectrophotometer

    by Catherine C. Cooksey, Thomas C. Larason, Heather J. Patrick, Clarence Zarobila

    The National Institute of Standards and Technology (NIST) has maintained and operated custom-built reference instruments to establish the national scale for regular spectral transmittance for more than 50 years. In this paper, we report on improvements to the performance of NIST’s current iteration of the reference instrument, the reference transmittance spectrophotometer (RTS), in the ultraviolet (UV) and visible spectral range. The improvements include the installation of a new UV source for increased spectral radiance and a monitor line for a reduced noise-to-signal ratio. A new uncertainty budget and validation measurements are presented. A reduction of uncertainties by 70% or more is achieved for UV wavelengths.


  • Traveling tunable laser projector for UV-blue disinfection dose determinations

    by Thomas Larason, Steven Grantham, Clarence Zarobila, Yuqin Zong, Michael Schuit, Brian Holland, Stewart Wood, Melissa Krause, C. Cameron Miller

    As the COVID-19 pandemic was overtaking the world in the spring of 2020, the National Institute of Standards and Technology (NIST) began collaborating with the National Biodefense Analysis and Countermeasures Center to study the inactivation of SARS-CoV-2 after exposure to different ultraviolet (UV) and blue light wavelengths. This paper describes a 1 kHz pulsed laser and projection system used to study the doses required to inactive SARS-CoV-2 over the wavelength range of 222 to 488 nm. This paper builds on NIST's previous work for water pathogen inactivation using UV laser irradiation. The design of the laser and projection system and its performance in a Biosafety Level 3 (BSL-3) laboratory are given. The SARS-CoV-2 inactivation results (published elsewhere by Schuit, M.A., et al., expected 2022) demonstrate that a tunable laser projection system is an invaluable tool for this research.


  • Measurements of absolute, SI-traceable lunar irradiance with the airborne lunar spectral irradiance (air-LUSI) instrument

    by J T Woodward, K R Turpie, T C Stone, S A Gadsden, A Newton, S E Maxwell, S E Grantham, T C Larason, S W Brown

    The airborne lunar spectral irradiance (air-LUSI) instrument is designed to make low uncertainty measurements of the lunar spectral irradiance from an ER-2 aircraft from altitudes above 95% of the atmosphere. Measurements cover the visible and near infrared spectral region (350 nm to 1050 nm) and are traceable to the international system of units. Five demonstration flights were conducted in November 2019 at NASA’s Armstrong Flight Research Center. During that campaign, air-LUSI measured the spectral irradiance at lunar phase angles ranging from 10° to 60°. This work provides an overview of the air-LUSI instrument, the lunar irradiance measurements made during demonstration flights, a description of our calibration approach, and summary of the uncertainty budget. Based on the flight results and laboratory measurements, we estimate the instrument is capable of measuring lunar irradiance, propagated to the top-of-the atmosphere, with combined standard uncertainty of 1% (k = 1) or less over the spectral region from 450 nm to 980 nm. An examination of the uncertainty budget leads to a path forward toward potentially achieving uncertainties of 0.6% in lunar irradiance over much of the spectral range for future flights.


  • Open Access

    The irradiance instrument subsystem (IRIS) on the airborne-lunar spectral irradiance (air-LUSI) instrument

    by Steven E Grantham, Kevin R Turpie, Thomas C Stone, S Andrew Gadsden, Thomas C Larason, Clarence J Zarobila, Stephen E Maxwell, John T Woodward, Steven W Brown

    The objective of the airborne lunar spectral irradiance (air-LUSI) project is to make low uncertainty, SI-traceable measurements of the LUSI in the visible to near-infrared region from an aircraft above most of the optically absorbing components of the atmosphere. The measurements are made from a NASA ER-2 aircraft, which can fly at altitudes of approximately 20 km above sea level. Air-LUSI measurements, corrected for residual atmospheric attenuation, are designed to provide a matrix of low uncertainty top-of-the-atmosphere lunar irradiances at known lunar phase and libration angles to be compared and combined with other lunar irradiance data sets to constrain the uncertainties in models of lunar irradiance and reflectance. The measurements are also expected to provide insight into the differences between models and satellite sensor measurements of lunar irradiance. This paper describes the development and characterization of the air-LUSI subsystem for acquiring lunar measurements, called the irradiance instrument subsystem, prior to flight.


  • Optical and mechanical design of a telescope for lunar spectral irradiance measurements from a high-altitude aircraft

    by C. J. Zarobila, S. Grantham, S. W. Brown, J. T. Woodward, S. E. Maxwell, D. R. Defibaugh, T. C. Larason, K. R. Turpie

    We have designed a non-imaging telescope for measurement of the spectral irradiance of the moon. The telescope was designed to be integrated into a wing pod of a National Aeronautics and Space Administration ER-2 research aircraft to measure lunar spectral irradiance during flight. The telescope and support system were successfully flown in August 2018 at altitudes near 21 km and at speeds of ∼760 km/h. The wing pod in which the telescope is mounted has an opening through which the moon can be observed. The mount exposes the telescope to high winds, low pressures, temperatures near −60 °C, and vibrations both due to flight and due to the motion of the aircraft on the ground. This required a telescope design with high thermal stability and high resistance to shock. The optical design of the telescope is optimized to have high throughput and spatially uniform transmission from 380 nm to 1000 nm over a field of view about three times the angular size of the moon as viewed from the Earth. The final design resulted in a telescope with singlet design incorporating a 139.7 mm lens with an effective focal length of 377 mm and a field of view of 1.6°. The light from the telescope is introduced into an integrating sphere, which destroys the image and the polarization for measurement by a fiber-coupled spectroradiometer. Herein, we present an overview of the instrument and support system with emphasis on the telescope design.


  • National Institute of Standards and Technology transportable tunable ultraviolet laser irradiance facility for water pathogen inactivation

    by Thomas C. Larason

    A method of ultraviolet germicidal irradiation (UVGI) for water pathogen inactivation effectiveness using tunable, narrowband laser light is described. A transportable tunable UV (TTUV) laser system for providing a known irradiance (μW/cm2) or dose (mJ/cm2) suitable for irradiating water samples in Petri dishes over the wavelength range of 210 nm–300 nm was developed by the National Institute of Standards and Technology. The TTUV facility, consisting of a 1 kHz pulsed UV laser and light-tight enclosure containing the optics necessary to uniformly irradiate a water sample, was used in a microbiology laboratory to dose drinking water pathogens and surrogates as part of a Water Research Foundation study in the summer and fall of 2012. The approach demonstrated improved accuracy and simplified spectral analysis over conventional pathogen inactivation sources consisting of broadband UV sources and bandpass filters. In this work, the TTUV facility design and key components are described, including modifications in the field to provide the required irradiance levels. The irradiance and dose levels produced by the tunable UV laser during the project are also presented. The transportability of the TTUV system enabled it to be brought to a microbiology facility allowing the water samples (microbial suspensions) to be irradiated in a location with experienced staff and facilities for preparing, handling, analyzing, storing, and shipping the many samples studied. These results, published elsewhere, established that the tunable UV laser system provides unique UVGI capabilities for use with water pathogens and has applications for other pathogen experiments, for example, air-purification studies.


  • Gain Calibration of Current-to-Voltage Converters

    by Thomas Larason, C. Cameron Miller

    Current-to-voltage converters are used in many photometric and radiometric applications. The calibration of current-to-voltage converters at a few input currents is not always sufficient to understand the linearity and the bias of a device. Many devices have structure deviating from a linear response over the operating range of a gain setting. Measurement services that rely on these devices now have decreased uncertainties to a level that requires quantifying the uncertainties and understanding how they propagate. The National Institute of Standards and Technology has developed a system to calibrate the current-to-voltage conversion factor or “gain” and offset of these devices for direct current photocurrents. The equipment used for the calibration is described here, and the results and uncertainties are discussed.


  • Calibration of night vision goggles: an SI-units-based gain measurement technique

    by Vyacheslav B. Podobedov, George P. Eppeldauer, Thomas C. Larason

    A gain measurement technique for the calibration of night vision goggles (NVG) is proposed and evaluated. This technique is based on the radiance measurements at the input and output of the NVG. In contrast to the old definition, which uses a non-International System of Units (SI) traceable luminance, the “equivalent luminance unit,” the suggested technique utilizes the radiance quantities that are traceable to the SI units through National Institute of Standards and Technology (NIST) standards. Due to the implementation of the scaling coefficients originating from the NVG spectral responsivities, the same NVG gain is expected within both techniques. The suggested method was evaluated at the NIST night vision calibration facility and the experimental data were compared to the results obtained with a commercial NVG test set. The comparison of the radiometric quantities obtained using the two different methods indicated differences up to 15% due to different calibration conditions. However, at proper calibration, equal NVG gains within both the suggested and old gain definitions were measured for the goggles equipped with a filmless image tube. The NVG gain uncertainty analysis, including the effect of no-moon night sky radiation, was performed for goggle types A, B, and C.


  • Calibration of spectral responsivity of IR detectors in the range from 0.6 μm to 24 μm

    by Vyacheslav B. Podobedov, George P. Eppeldauer, Leonard M. Hanssen, Thomas C. Larason