Daniel E. Sabath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel E. Sabath has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Karen M. Koehler
2 shared publications- Alisa C Clein
Departments of Laboratory Medicine and Medicine, University of Washington, Washington, USA
1 shared publication - Amy Marie Breman
Department of Medical and Molecular Genetics Indiana University School of Medicine Indianapolis Indiana USA
1 shared publication - Arturo B. Ramirez
Rarecyte Inc
1 shared publication - Barry H Friemel
RareCyte, Inc, Seattle, WA, USA
1 shared publication - Carl Anthony Blau
Center for Cancer Innovation, University of Washington, Seattle, WA, USA
1 shared publication
Latest Publications
- Open Access
- 6 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-13
High-recovery visual identification and single-cell retrieval of circulating tumor cells for genomic analysis using a dual-technology platform integrated with automated immunofluorescence staining
Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte® – CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte – CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte – CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.
- 6 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-13
Open AccessHigh-recovery visual identification and single-cell retrieval of circulating tumor cells for genomic analysis using a dual-technology platform integrated with automated immunofluorescence staining
Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte® – CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte – CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte – CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.
- 18 March 2003
- Published by Wiley in Clinical and Laboratory Haematology
- Vol. 25 (2) , 87-91
An improved method for detecting red cells with hemoglobin H inclusions that does not require glass capillary tubes
Alpha-Thalassemia trait is the most common inherited abnormality worldwide. Diagnosis of alpha-thalassemia trait can be difficult as there are no abnormalities detectable by hemoglobin electrophoresis or high-performance liquid chromatography. Detection of individuals with alpha-thalassemia trait, particularly the type present in many Asian populations, is important for genetic counseling purposes, because these individuals are at risk for having offspring with hemoglobin Bart's hydrops fetalis, a fatal condition. The best routine diagnostic method to detect individuals with alpha-thalassemia trait is staining reticulocyte-enriched red cell preparations with brilliant cresyl blue to detect hemoglobin H inclusions. Current methods use centrifugation of microhematocrit tubes to enrich for reticulocytes, which presents a laboratory safety hazard. In this report, we describe an alternative technique to enrich for reticulocytes that does not require glass capillary tubes, but is as effective as the capillary tube method for reticulocyte enrichment and detection of cells containing hemoglobin H inclusions.
- 18 March 2003
- Published by Wiley in Clinical and Laboratory Haematology
- Vol. 25 (2) , 87-91
An improved method for detecting red cells with hemoglobin H inclusions that does not require glass capillary tubes
Alpha-Thalassemia trait is the most common inherited abnormality worldwide. Diagnosis of alpha-thalassemia trait can be difficult as there are no abnormalities detectable by hemoglobin electrophoresis or high-performance liquid chromatography. Detection of individuals with alpha-thalassemia trait, particularly the type present in many Asian populations, is important for genetic counseling purposes, because these individuals are at risk for having offspring with hemoglobin Bart's hydrops fetalis, a fatal condition. The best routine diagnostic method to detect individuals with alpha-thalassemia trait is staining reticulocyte-enriched red cell preparations with brilliant cresyl blue to detect hemoglobin H inclusions. Current methods use centrifugation of microhematocrit tubes to enrich for reticulocytes, which presents a laboratory safety hazard. In this report, we describe an alternative technique to enrich for reticulocytes that does not require glass capillary tubes, but is as effective as the capillary tube method for reticulocyte enrichment and detection of cells containing hemoglobin H inclusions.
- Open Access
- 15 March 2002
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 185 (6) , 828-832
Cellular Immunity in Monozygotic Twins Discordant for Chronic Fatigue Syndrome
Studies elsewhere have suggested that immune dysfunction may be common in patients with chronic fatigue syndrome (CFS). The objective of this study w
- 15 March 2002
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 185 (6) , 828-832
Open AccessCellular Immunity in Monozygotic Twins Discordant for Chronic Fatigue Syndrome
Studies elsewhere have suggested that immune dysfunction may be common in patients with chronic fatigue syndrome (CFS). The objective of this study w
- Open Access
- 1 May 2000
- Published by Taylor & Francis in BioTechniques
- Vol. 28 (5) , 966-974
Use of Green Fluorescent Protein/Flp Recombinase Fusion Protein and Flow Cytometric Sorting to Enrich for Cells Undergoing Flp-Mediated Recombination
Flp recombinase has been used extensively for in vivo manipulation of eukaryotic DNA at specific sequences designated as FRT sites. We developed a method to use Flp-mediated recombination without t...
- 1 May 2000
- Published by Taylor & Francis in BioTechniques
- Vol. 28 (5) , 966-974
Open AccessUse of Green Fluorescent Protein/Flp Recombinase Fusion Protein and Flow Cytometric Sorting to Enrich for Cells Undergoing Flp-Mediated Recombination
Flp recombinase has been used extensively for in vivo manipulation of eukaryotic DNA at specific sequences designated as FRT sites. We developed a method to use Flp-mediated recombination without t...
- 1 June 1998
- Published by Elsevier in Blood Cells, Molecules, and Diseases
- Vol. 24 (2) , 183-198
DNA-Protein Interactions in the Proximal ζ-Globin Promoter: Identification of Novel CCACCC- and CCAAT-binding Proteins
- 1 June 1998
- Published by Elsevier in Blood Cells, Molecules, and Diseases
- Vol. 24 (2) , 183-198
DNA-Protein Interactions in the Proximal ζ-Globin Promoter: Identification of Novel CCACCC- and CCAAT-binding Proteins
- Open Access
- 1 December 1996
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 24 (24) , 4978-4986
Structure and Function of the -globin Upstream Regulatory Element
The human ζ-globin promoter contains a strong positive regulatory element in the 5′ flanking region, designated the ζ-globin upstream regulatory element (URE). In this study, we define the minimal sequences required for URE function and characterize the associated protein-DNA interactions. Deletion experiments show that the URE spans a 60 bp region located between 220 and 279 bp 5′ to the transcription start site. Further subdivision of this region shows that multiple cis acting sequences are present. Electrophoretic mobility shift assays demonstrate that the erythroid transcription factor GATA-1 binds a site at −230, and Sp1 and an unidentified factor bind a CCACC site at −240. The unidentified CCACC factor is distinct from two other CCACC factors, EKLF and BKLF/TEF-2. A third complex contains a novel DNA-binding activity that interacts with a site in the −269 to −255 region, designated URE binding factor (URE-BF). This factor is present in K562 cells that express ζ-globin, but is absent in the OCIM1 cell line, a human erythroid cell line that does not express ζ-globin. URE-BF appears to interact with a GATA factor, since formation of the URE-BF complex can be prevented by the presence of unlabeled oligonucleotides containing GATA sites. Finally, increasing the distance from the −230 GATA site to the two upstream sites causes a progressive decrease in ζ-globin promoter activity. There is no indication of a requirement for GATA-1 to be on the same side of the DNA helix as the other upstream factors. These results show that ζ-globin promoter function is highly dependent on a 60 bp region to which at least three different factors bind. Two of these factors may represent DNA-binding proteins not previously identified as important for regulation of globin gene expression. It is likely that these factors interact physically to create a functional regulatory unit.
- 1 December 1996
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 24 (24) , 4978-4986
Open AccessStructure and Function of the -globin Upstream Regulatory Element
The human ζ-globin promoter contains a strong positive regulatory element in the 5′ flanking region, designated the ζ-globin upstream regulatory element (URE). In this study, we define the minimal sequences required for URE function and characterize the associated protein-DNA interactions. Deletion experiments show that the URE spans a 60 bp region located between 220 and 279 bp 5′ to the transcription start site. Further subdivision of this region shows that multiple cis acting sequences are present. Electrophoretic mobility shift assays demonstrate that the erythroid transcription factor GATA-1 binds a site at −230, and Sp1 and an unidentified factor bind a CCACC site at −240. The unidentified CCACC factor is distinct from two other CCACC factors, EKLF and BKLF/TEF-2. A third complex contains a novel DNA-binding activity that interacts with a site in the −269 to −255 region, designated URE binding factor (URE-BF). This factor is present in K562 cells that express ζ-globin, but is absent in the OCIM1 cell line, a human erythroid cell line that does not express ζ-globin. URE-BF appears to interact with a GATA factor, since formation of the URE-BF complex can be prevented by the presence of unlabeled oligonucleotides containing GATA sites. Finally, increasing the distance from the −230 GATA site to the two upstream sites causes a progressive decrease in ζ-globin promoter activity. There is no indication of a requirement for GATA-1 to be on the same side of the DNA helix as the other upstream factors. These results show that ζ-globin promoter function is highly dependent on a 60 bp region to which at least three different factors bind. Two of these factors may represent DNA-binding proteins not previously identified as important for regulation of globin gene expression. It is likely that these factors interact physically to create a functional regulatory unit.