Robert T. Palac
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert T. Palac has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Brenda E. Arbuckle
2 shared publications- Salvatore P. Costa
Department of Cardiology; Dartmouth-Hitchcock Medical Center; Lebanon; New Hampshire
2 shared publications - Timothy A. Beaver
Department of Cardiology; Dartmouth-Hitchcock Medical Center; Lebanon; New Hampshire
2 shared publications Alan Jansujwicz
Echocardiography Laboratory, Dartmouth‐Hitchcock Medical Center, Lebanon, New Hampshire
1 shared publicationAlan T. Kono
Dartmouth-Hitchcock Medical Center, Lebanon, NH
1 shared publicationAlina M. Robert
Dartmouth-Hitchcock Medical Center, Lebanon, NH
1 shared publication
Latest Publications
- 11 January 2013
- Published by Wiley in Echocardiography
- Vol. 30 (4)
An Unusual Left Atrial Mass in Hypertrophic Cardiomyopathy: The Role of Multimodality Imaging
- 11 January 2013
- Published by Wiley in Echocardiography
- Vol. 30 (4)
An Unusual Left Atrial Mass in Hypertrophic Cardiomyopathy: The Role of Multimodality Imaging
- 31 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , S98
Heart Failure With Preserved Ejection Fraction in a Real World Patient Population: How Good Is Echocardiography at Identifying Elevated Left Ventricular Pressure?
- 31 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , S98
Heart Failure With Preserved Ejection Fraction in a Real World Patient Population: How Good Is Echocardiography at Identifying Elevated Left Ventricular Pressure?
- 14 April 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 65 (3) , 340-345
Live 3D echo guidance of catheter-based endomyocardial injection
Local delivery of therapeutic agents into the myocardium is limited by suboptimal imaging. We evaluated the feasibility and accuracy of live 3D echo to guide left ventricular endomyocardial injection. An intramyocardial injection catheter was positioned in the left ventricle in five healthy Yorkshire pigs using fluoroscopy. All other catheter manipulations were performed with live biplane and 3D echo guidance. In each animal, a total of 12 endomyocardial injections (volume, 50–100 μl) of echo contrast mixed with blue tissue dye were performed. Four injections, 10 mm apart, were directed to three myocardial target zones: the anterior septum at the mitral valve level (zone 1); the posterolateral wall between the heads of the papillary muscles (zone 2); and the apex (zone 3). The injections were aimed to form a transverse line in zones 1 and 2 and an inverted triangular pyramid in zone 3. The animals were sacrificed, the hearts were inspected and the left ventricular endocardium was examined to create a map of injection marks. Success, defined as a visible injection of tissue dye, was 95%, and accuracy, defined as an injection into the target zone, was 83%. There was no significant difference in accuracy between the zones. Live 3D echo can successfully guide endomyocardial injections by accurately targeting specific myocardial zones, verifying catheter apposition and, when combined with echo contrast, providing real-time visualization of injectate deposition.
- 14 April 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 65 (3) , 340-345
Live 3D echo guidance of catheter-based endomyocardial injection
Local delivery of therapeutic agents into the myocardium is limited by suboptimal imaging. We evaluated the feasibility and accuracy of live 3D echo to guide left ventricular endomyocardial injection. An intramyocardial injection catheter was positioned in the left ventricle in five healthy Yorkshire pigs using fluoroscopy. All other catheter manipulations were performed with live biplane and 3D echo guidance. In each animal, a total of 12 endomyocardial injections (volume, 50–100 μl) of echo contrast mixed with blue tissue dye were performed. Four injections, 10 mm apart, were directed to three myocardial target zones: the anterior septum at the mitral valve level (zone 1); the posterolateral wall between the heads of the papillary muscles (zone 2); and the apex (zone 3). The injections were aimed to form a transverse line in zones 1 and 2 and an inverted triangular pyramid in zone 3. The animals were sacrificed, the hearts were inspected and the left ventricular endocardium was examined to create a map of injection marks. Success, defined as a visible injection of tissue dye, was 95%, and accuracy, defined as an injection into the target zone, was 83%. There was no significant difference in accuracy between the zones. Live 3D echo can successfully guide endomyocardial injections by accurately targeting specific myocardial zones, verifying catheter apposition and, when combined with echo contrast, providing real-time visualization of injectate deposition.
- 14 May 2003
- Published by Wiley in Echocardiography
- Vol. 20 (4) , 337-343
Integrated Backscatter During Harmonic and Fundamental Frequency Imaging—Effect of Depth, Mechanical Index, and Tissue Anisotropy: Implications for Myocardial Tissue Characterization
Objective: To explore the potential advantages of tissue harmonic imaging (THI) versus fundamental frequency imaging (FFI) when applied to tissue characterization. Methods: A Philips Medical Systems Sonos 5500 echocardiograph equipped with a broadband transducer (S4) and an on‐line quantitative analysis software package (Acoustic Densitometry) was used for imaging. The effect of mechanical index (MI), imaging depth, and anisotropy on relative backscatter amplitude was evaluated. Results: This study demonstrated that imaging with tissue harmonics generated relatively greater backscatter values at clinically relevant imaging depths and instrument settings referenced to FFI. This effect was dependent on MI setting. A direct relationship between backscatter amplitude and MI was demonstrated. Additionally, tissue anisotropy had similar effects on integrated backscatter amplitude during both THI and FFI. However, relative backscatter values at each fiber orientation are greater during THI at similar instrument settings when referenced to FFI. Conclusion: Tissue harmonic imaging may offer advantages over FFI for myocardial tissue characterization. (ECHOCARDIOGRAPHY, Volume 20, May 2003)
- 14 May 2003
- Published by Wiley in Echocardiography
- Vol. 20 (4) , 337-343
Integrated Backscatter During Harmonic and Fundamental Frequency Imaging—Effect of Depth, Mechanical Index, and Tissue Anisotropy: Implications for Myocardial Tissue Characterization
Objective: To explore the potential advantages of tissue harmonic imaging (THI) versus fundamental frequency imaging (FFI) when applied to tissue characterization. Methods: A Philips Medical Systems Sonos 5500 echocardiograph equipped with a broadband transducer (S4) and an on‐line quantitative analysis software package (Acoustic Densitometry) was used for imaging. The effect of mechanical index (MI), imaging depth, and anisotropy on relative backscatter amplitude was evaluated. Results: This study demonstrated that imaging with tissue harmonics generated relatively greater backscatter values at clinically relevant imaging depths and instrument settings referenced to FFI. This effect was dependent on MI setting. A direct relationship between backscatter amplitude and MI was demonstrated. Additionally, tissue anisotropy had similar effects on integrated backscatter amplitude during both THI and FFI. However, relative backscatter values at each fiber orientation are greater during THI at similar instrument settings when referenced to FFI. Conclusion: Tissue harmonic imaging may offer advantages over FFI for myocardial tissue characterization. (ECHOCARDIOGRAPHY, Volume 20, May 2003)