Timothy A. Beaver
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Timothy A. Beaver has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Robert T. Palac
Department of Cardiology; Dartmouth-Hitchcock Medical Center; Lebanon; New Hampshire
2 shared publications - Salvatore P. Costa
Department of Cardiology; Dartmouth-Hitchcock Medical Center; Lebanon; New Hampshire
2 shared publications Alan T. Kono
Dartmouth-Hitchcock Medical Center, Lebanon, NH
1 shared publicationAlina M. Robert
Dartmouth-Hitchcock Medical Center, Lebanon, NH
1 shared publicationClyde D. Sullivan
Department of Cardiology, Dartmouth‐Hitchcock Medical Center, Lebanon, New Hampshire
1 shared publicationDaniel J. O'Rourke
Dartmouth-Hitchcock Medical Center, Lebanon, NH
1 shared publication
Latest Publications
- 11 January 2013
- Published by Wiley in Echocardiography
- Vol. 30 (4)
An Unusual Left Atrial Mass in Hypertrophic Cardiomyopathy: The Role of Multimodality Imaging
- 11 January 2013
- Published by Wiley in Echocardiography
- Vol. 30 (4)
An Unusual Left Atrial Mass in Hypertrophic Cardiomyopathy: The Role of Multimodality Imaging
- 6 October 2010
- Published by Wiley in Echocardiography
- Vol. 28 (1) , 22-28
Two-Dimensional Longitudinal Strain in Patients with Aortic Stenosis Can Be Reliably Acquired at the Bedside without Additional Benefit of Offline Analysis
Two-dimensional strain echocardiography (2DS) has been used to assess ventricular function in several disease states. In previous studies of 2DS, strain analysis was usually performed offline by experienced echocardiographers. The applicability of 2DS in busy clinical labs would be enhanced if 2DS could be reproducibly measured by sonographers at the time of the echo exam. In this study we compared the reproducibility of strain measurements between sonographers at the time of the echo exam with those performed offline by an experienced echocardiographer. Apical left ventricular (LV) B-mode images were acquired in 98 consecutive patients being evaluated for aortic stenosis. 2DS analysis was performed at the time of the exam by a sonographer. The same images were analyzed offline by an experienced echocardiographer. Global longitudinal strain (GLS) results were analyzed for interobserver reproducibility. Additionally, the regional longitudinal strain (RLS) of 20 randomly selected patients was analyzed for intraobserver reproducibility. Acceptable data quality was available in 97.8% of the segments measured at the time of the exam and in 96.9% at the workstation. Interobserver reproducibility of the global peak strain was high (r = 0.855, P < 0.001). Additionally, applying cutoffs for separating normal from abnormal GLS revealed good agreement between sonographer and experienced echocardiographer [kappa analysis (κ= 0.739, P < 0.001)]. Overall RLS intraobserver reproducibility was high (raw mean adjusted r = 0.915). The GLS in aortic stenosis patients can be reliably measured at the bedside by a sonographer without additional benefit of offline analysis.
- 6 October 2010
- Published by Wiley in Echocardiography
- Vol. 28 (1) , 22-28
Two-Dimensional Longitudinal Strain in Patients with Aortic Stenosis Can Be Reliably Acquired at the Bedside without Additional Benefit of Offline Analysis
Two-dimensional strain echocardiography (2DS) has been used to assess ventricular function in several disease states. In previous studies of 2DS, strain analysis was usually performed offline by experienced echocardiographers. The applicability of 2DS in busy clinical labs would be enhanced if 2DS could be reproducibly measured by sonographers at the time of the echo exam. In this study we compared the reproducibility of strain measurements between sonographers at the time of the echo exam with those performed offline by an experienced echocardiographer. Apical left ventricular (LV) B-mode images were acquired in 98 consecutive patients being evaluated for aortic stenosis. 2DS analysis was performed at the time of the exam by a sonographer. The same images were analyzed offline by an experienced echocardiographer. Global longitudinal strain (GLS) results were analyzed for interobserver reproducibility. Additionally, the regional longitudinal strain (RLS) of 20 randomly selected patients was analyzed for intraobserver reproducibility. Acceptable data quality was available in 97.8% of the segments measured at the time of the exam and in 96.9% at the workstation. Interobserver reproducibility of the global peak strain was high (r = 0.855, P < 0.001). Additionally, applying cutoffs for separating normal from abnormal GLS revealed good agreement between sonographer and experienced echocardiographer [kappa analysis (κ= 0.739, P < 0.001)]. Overall RLS intraobserver reproducibility was high (raw mean adjusted r = 0.915). The GLS in aortic stenosis patients can be reliably measured at the bedside by a sonographer without additional benefit of offline analysis.
- 31 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , S98
Heart Failure With Preserved Ejection Fraction in a Real World Patient Population: How Good Is Echocardiography at Identifying Elevated Left Ventricular Pressure?
- 31 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , S98
Heart Failure With Preserved Ejection Fraction in a Real World Patient Population: How Good Is Echocardiography at Identifying Elevated Left Ventricular Pressure?