M. Ichimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
M. Ichimura has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
H. Hojo
Plasma Res. Center, Tsukuba Univ., Ibaraki, Japan
5 shared publicationsY. Nakashima
Plasma Research Center, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan
5 shared publications- Hidehiko Higaki
Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, Fukuoka, Japan
4 shared publications K. Yatsu
Plasma Res. Center, Tsukuba Univ., Ibaraki, Japan
4 shared publicationsT. Saito
Department of Applied Physics, University of Miyazaki, Miyazaki, Miyazaki 889-2192, Japan
4 shared publications- A. Itakura
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
3 shared publications
Latest Publications
- 11 October 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1771 (1) , 060001
Impact of target temperature on hydrogen recycling in divertor simulation plasma of GAMMA 10/PDX tandem mirror
In GAMMA 10/PDX, a temperature-controlled V-shaped target has been utilized to study an effect of target temperature on hydrogen recycling. The V-shaped tungsten target in the divertor simulation experimental module (D-module) is heated up to 573 K and it is exposed to the end loss plasma. It is found that the Hα intensity and the electron density of the plasma in front of the target are positively correlated with the target temperature, indicating that the recycling is enhanced due to increase in the target temperature. Moreover, additional hydrogen gas is injected into the D-module with the temperature-controlled target. As the amount of hydrogen gas injection increased, enhancement of hydrogen recycling by high temperature target becomes smaller.
- 11 October 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1771 (1) , 060001
Impact of target temperature on hydrogen recycling in divertor simulation plasma of GAMMA 10/PDX tandem mirror
In GAMMA 10/PDX, a temperature-controlled V-shaped target has been utilized to study an effect of target temperature on hydrogen recycling. The V-shaped tungsten target in the divertor simulation experimental module (D-module) is heated up to 573 K and it is exposed to the end loss plasma. It is found that the Hα intensity and the electron density of the plasma in front of the target are positively correlated with the target temperature, indicating that the recycling is enhanced due to increase in the target temperature. Moreover, additional hydrogen gas is injected into the D-module with the temperature-controlled target. As the amount of hydrogen gas injection increased, enhancement of hydrogen recycling by high temperature target becomes smaller.
- 1 April 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1524 (1) , 46
Decomposing spin-dipole resonances by complete polarization transfer measurements
We report measurements of cross sections and analyzing powers for reaction angles of θlab = 0.0°-10.0° and complete sets of polarization transfer observables and induced polarizations at θlab = 0.0°-7.0° for the reaction at a bombarding energy of Tp = 296 MeV. A multipole decomposition technique was applied to the data to extract the spin-dipole (SD) components from the continuum. The polarization observables were also used, for the first time, to separate the SD components into different spin-parity transfer (ΔJπ = 0−, 1−, and 2−) contributions. The SD strength distributions were clearly dependent on ΔJπ, which is reasonably reproduced by Hartree-Fock (HF) plus random phase approximation (RPA) calculations that include the Skyrme interaction with tensor components [C. L. Bai et al., Phys. Rev. C 83, 054316 (2011)].- 1 April 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1524 (1) , 46
Decomposing spin-dipole resonances by complete polarization transfer measurements
We report measurements of cross sections and analyzing powers for reaction angles of θlab = 0.0°-10.0° and complete sets of polarization transfer observables and induced polarizations at θlab = 0.0°-7.0° for the reaction at a bombarding energy of Tp = 296 MeV. A multipole decomposition technique was applied to the data to extract the spin-dipole (SD) components from the continuum. The polarization observables were also used, for the first time, to separate the SD components into different spin-parity transfer (ΔJπ = 0−, 1−, and 2−) contributions. The SD strength distributions were clearly dependent on ΔJπ, which is reasonably reproduced by Hartree-Fock (HF) plus random phase approximation (RPA) calculations that include the Skyrme interaction with tensor components [C. L. Bai et al., Phys. Rev. C 83, 054316 (2011)].- 1 January 2006
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 8 (1) , 87-90
ICRF Experiments and Potential Formation on the GAMMA 10 Tandem Mirror
- 1 January 2006
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 8 (1) , 87-90
ICRF Experiments and Potential Formation on the GAMMA 10 Tandem Mirror
- 22 September 2005
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 787 (1) , 98
Long Pulse Plasma Heating Experiment by Ion Cyclotron Heating in LHD
It is very important to demonstrate the ability to sustain the plasma in a steady state on the Large Helical Device (LHD), which has external helical magnetic coils and is a superconducting device. The long pulse discharge experiment was carried out using the ion cyclotron range of frequencies (ICRF) heating mainly. The plasma discharge of 31 minutes and 45 seconds was achieved by a total injected heating energy of 1.3GJ. Swing of the magnetic axis to scatter the local heat load on the divertor plate was one of the key methods for the steady state operation. The repetitive hydrogen pellet injection was tried successfully to fuel the minority hydrogen ions for long pulse operation.
- 22 September 2005
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 787 (1) , 98
Long Pulse Plasma Heating Experiment by Ion Cyclotron Heating in LHD
It is very important to demonstrate the ability to sustain the plasma in a steady state on the Large Helical Device (LHD), which has external helical magnetic coils and is a superconducting device. The long pulse discharge experiment was carried out using the ion cyclotron range of frequencies (ICRF) heating mainly. The plasma discharge of 31 minutes and 45 seconds was achieved by a total injected heating energy of 1.3GJ. Swing of the magnetic axis to scatter the local heat load on the divertor plate was one of the key methods for the steady state operation. The repetitive hydrogen pellet injection was tried successfully to fuel the minority hydrogen ions for long pulse operation.
- 1 October 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (10) , 4317-4319
Ion measurement of the edge plasma in the GAMMA10 tandem mirror device with an ion sensitive probe
An ion sensitive probe (ISP) has been applied to ion diagnostics of the edge plasma of the GAMMA10 tandem mirror device. Since high energy ions are created by ion cyclotron range of frequency heating in the central cell of GAMMA10, a secondary electron repeller electrode is set in to suppress secondary electrons emitted from the collector due to high energy ions. Then secondary electrons are successfully suppressed. The ion flux flowing into the collector is evaluated with numerical calculation of ion orbits. This calculation includes the potential profile near the tip of the ISP. Then a correction factor of the ion flux to the free streaming one is determined. The calculation yields characteristic of the collector current. The ion density can be estimated by using the measured ion temperature and the factor . Sample data of the ion temperature and the ion density in the edge region of the central cell of GAMMA10 are given. The measurement with the ISP shows that the edge ion temperature of GAMMA10 plasma ranges from 100 to , and the ion density from to .- 1 October 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (10) , 4317-4319
Ion measurement of the edge plasma in the GAMMA10 tandem mirror device with an ion sensitive probe
An ion sensitive probe (ISP) has been applied to ion diagnostics of the edge plasma of the GAMMA10 tandem mirror device. Since high energy ions are created by ion cyclotron range of frequency heating in the central cell of GAMMA10, a secondary electron repeller electrode is set in to suppress secondary electrons emitted from the collector due to high energy ions. Then secondary electrons are successfully suppressed. The ion flux flowing into the collector is evaluated with numerical calculation of ion orbits. This calculation includes the potential profile near the tip of the ISP. Then a correction factor of the ion flux to the free streaming one is determined. The calculation yields characteristic of the collector current. The ion density can be estimated by using the measured ion temperature and the factor . Sample data of the ion temperature and the ion density in the edge region of the central cell of GAMMA10 are given. The measurement with the ISP shows that the edge ion temperature of GAMMA10 plasma ranges from 100 to , and the ion density from to .- 1 October 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (10) , 4085-4087
Measurement of low frequency plasma fluctuations with a visible light detector in GAMMA 10
Low frequency fluctuations of a plasma in the central cell of the GAMMA10 tandem mirror have been observed with electrostatic probes (ESPs) installed at the peripheral region of the plasma. Typical plasma parameters for a hot ion mode operation are , , , , and . Although the ESP is an effective tool to measure local plasma parameters and fluctuations, it can be damaged with the higher electron temperature. Here, a new visible light detector was introduced, which could measure the plasma fluctuations without contacting the plasma. The obtained results were compared with those of ESPs. It is found that the visible light detector is applicable when the electron temperature becomes much higher in the future experiment.- 1 October 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (10) , 4085-4087
Measurement of low frequency plasma fluctuations with a visible light detector in GAMMA 10
Low frequency fluctuations of a plasma in the central cell of the GAMMA10 tandem mirror have been observed with electrostatic probes (ESPs) installed at the peripheral region of the plasma. Typical plasma parameters for a hot ion mode operation are , , , , and . Although the ESP is an effective tool to measure local plasma parameters and fluctuations, it can be damaged with the higher electron temperature. Here, a new visible light detector was introduced, which could measure the plasma fluctuations without contacting the plasma. The obtained results were compared with those of ESPs. It is found that the visible light detector is applicable when the electron temperature becomes much higher in the future experiment.- 22 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Production of high density plasmas with high harmonic fast waves in the GAMMA 10 tandem mirror
Summary form only given, as follows. At present, the realization of high-density operation with potential confinement is one of the most important issues on the tandem mirror research. The plasma production with ion-cyclotron-range of frequency (ICRF) waves is common in both fusion and plasma applications. In plasmas with relatively low density and small radius the wavelength is in the same order of the plasma size and eigenmodes are formed in both radial and axial directions. Because the wavelength depends strongly on the density, the density is likely to be clamped at the optimum value for the eigenmode formation. The saturation of the density increase is sometimes observed in GAMMA 10. To raise the limit for the density clamping, higher frequency ICRF waves (high harmonic fast waves HHFWs) of which frequencies are from 6 to 10 times ion cyclotron frequency at the midplane of the central cell have been introduced. HHFWs are effectively used for the current drive experiments on the spherical torus. When HHFWs are applied, several eigenmodes with different radial structures will be possibly excited and the restriction of the density clamping becomes moderate. The increase of the density from the saturation level has been clearly observed in the experiments. The excitation of waves with higher mode structure in the radial direction is measured when the apparent density increase is observed.
- 22 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Production of high density plasmas with high harmonic fast waves in the GAMMA 10 tandem mirror
Summary form only given, as follows. At present, the realization of high-density operation with potential confinement is one of the most important issues on the tandem mirror research. The plasma production with ion-cyclotron-range of frequency (ICRF) waves is common in both fusion and plasma applications. In plasmas with relatively low density and small radius the wavelength is in the same order of the plasma size and eigenmodes are formed in both radial and axial directions. Because the wavelength depends strongly on the density, the density is likely to be clamped at the optimum value for the eigenmode formation. The saturation of the density increase is sometimes observed in GAMMA 10. To raise the limit for the density clamping, higher frequency ICRF waves (high harmonic fast waves HHFWs) of which frequencies are from 6 to 10 times ion cyclotron frequency at the midplane of the central cell have been introduced. HHFWs are effectively used for the current drive experiments on the spherical torus. When HHFWs are applied, several eigenmodes with different radial structures will be possibly excited and the restriction of the density clamping becomes moderate. The increase of the density from the saturation level has been clearly observed in the experiments. The excitation of waves with higher mode structure in the radial direction is measured when the apparent density increase is observed.
- 8 July 2003
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 669 (1) , 170
Excitation of Alfvén Waves in Mirror Plasmas with a Strong Temperature Anisotropy
In the GAMMA 10 tandem mirror, fAlfvén ion cyclotron modes are spontaneously excited due to the strong temperature anisotropy. The plasma parameters needed for the excitation are explained by the theoretical prediction with the effective mirror ratio. It is suggested that the power of ICRF waves applied externally branches off spontaneously excited Alfvén eigenmodes directly.
- 8 July 2003
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 669 (1) , 170
Excitation of Alfvén Waves in Mirror Plasmas with a Strong Temperature Anisotropy
In the GAMMA 10 tandem mirror, fAlfvén ion cyclotron modes are spontaneously excited due to the strong temperature anisotropy. The plasma parameters needed for the excitation are explained by the theoretical prediction with the effective mirror ratio. It is suggested that the power of ICRF waves applied externally branches off spontaneously excited Alfvén eigenmodes directly.
- 17 January 2001
- Published by American Nuclear Society in Fusion Technology
- Vol. 39 (1T) , 167-170
High-Density Plasma Production with Fast Alfvén Waves in the GAMMA 10 Tandem Mirror
In the rf-produced plasma, it will be a possible mechanism for the density clamping that the eigenmodes are formed in the axial direction. The higher frequency waves are effective for the higher density plasma production. On the conditions of such a saturation region, we observed clear increase of the density by using fast Alfvén wave with a frequency of tenth cyclotron higher harmonics at the midplane of the central cell. The increasing rate depends on the rf power. An increase of high energy ions is observed with the high frequency wave injection.
- 17 January 2001
- Published by American Nuclear Society in Fusion Technology
- Vol. 39 (1T) , 167-170
High-Density Plasma Production with Fast Alfvén Waves in the GAMMA 10 Tandem Mirror
In the rf-produced plasma, it will be a possible mechanism for the density clamping that the eigenmodes are formed in the axial direction. The higher frequency waves are effective for the higher density plasma production. On the conditions of such a saturation region, we observed clear increase of the density by using fast Alfvén wave with a frequency of tenth cyclotron higher harmonics at the midplane of the central cell. The increasing rate depends on the rf power. An increase of high energy ions is observed with the high frequency wave injection.
- 1 January 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (1) , 394-397
Axial profile measurement of Alfvén ion cyclotron eigenmodes
In the GAMMA10 tandem mirror, a strong ion cyclotron range of frequency heating is performed. As a result of the heating, the Alfvén ion cyclotron (AIC) modes are spontaneously excited due to the strong temperature anisotropy. The AIC modes in the GAMMA10 are excited as the axial eigenmodes and detected at the whole of the device. In the recent experiments, the clear standing wave structure is observed with the magnetic probe measurements. Characteristics of the AIC modes and the measurement of the axial profile are presented.
- 1 January 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (1) , 394-397
Axial profile measurement of Alfvén ion cyclotron eigenmodes
In the GAMMA10 tandem mirror, a strong ion cyclotron range of frequency heating is performed. As a result of the heating, the Alfvén ion cyclotron (AIC) modes are spontaneously excited due to the strong temperature anisotropy. The AIC modes in the GAMMA10 are excited as the axial eigenmodes and detected at the whole of the device. In the recent experiments, the clear standing wave structure is observed with the magnetic probe measurements. Characteristics of the AIC modes and the measurement of the axial profile are presented.