Hidehiko Higaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hidehiko Higaki has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- Satoshi Hamai
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
7 shared publications - Yasuharu Nakashima
Department of Orthopaedic Surgery, Kyushu University, Fukuoka, Japan
7 shared publications - Satoru Ikebe
Department of Information Science and Engineering, Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Ube, Yamaguchi, Japan
5 shared publications - Daisuke Hara
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
4 shared publications - M. Ichimura
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
4 shared publications Y. Nakanishi
4 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Flatback Deformity and Stiff Pelvic Mobility Alter the Optimal Cup Anteversion After Total Hip Arthroplasty
Background: Flatback deformity and stiff spinopelvic mobility (SPM) are recognized risk factors for dislocation after total hip arthroplasty. This study aimed to determine patient-specific optimal cup anteversion ranges associated with spinopelvic abnormalities. Methods: We analyzed postoperative sit-to-stand motion in 108 hips using three-dimensional-to-two-dimensional model-image registration. Implanted components were virtually positioned at their actual positions with inclination at 40°. Using pelvic tilt at maximal anterior tilt and standing, the range of combined anteversion (CA) satisfying required range of motion was evaluated. CA midpoint (CA_mid) and range (CA_range) were compared across spinopelvic alignment groups. Results: Flatback hips demonstrated a significantly lower CA_mid than normal (41.1° vs. 46.8°), whereas stiff SPM hips showed a similar CA_mid but a narrower CA_range (14.5° vs. 19.4°). Significant correlations were observed between spinopelvic alignment and CA parameters. Conclusions: Spinopelvic alignment influences both the optimal cup orientation and its tolerance range. Incorporating these factors may allow patient-specific optimization of acetabular component positioning. Level of Evidence: Level III , retrospective cohort study. See Instructions for Authors for a complete description of levels of evidence. Clinical Relevance: Personalized component positioning based on dynamic spinopelvic alignment may help reduce dislocation risk and improve implant stability in high-risk THA patients.
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Open AccessFlatback Deformity and Stiff Pelvic Mobility Alter the Optimal Cup Anteversion After Total Hip Arthroplasty
Background: Flatback deformity and stiff spinopelvic mobility (SPM) are recognized risk factors for dislocation after total hip arthroplasty. This study aimed to determine patient-specific optimal cup anteversion ranges associated with spinopelvic abnormalities. Methods: We analyzed postoperative sit-to-stand motion in 108 hips using three-dimensional-to-two-dimensional model-image registration. Implanted components were virtually positioned at their actual positions with inclination at 40°. Using pelvic tilt at maximal anterior tilt and standing, the range of combined anteversion (CA) satisfying required range of motion was evaluated. CA midpoint (CA_mid) and range (CA_range) were compared across spinopelvic alignment groups. Results: Flatback hips demonstrated a significantly lower CA_mid than normal (41.1° vs. 46.8°), whereas stiff SPM hips showed a similar CA_mid but a narrower CA_range (14.5° vs. 19.4°). Significant correlations were observed between spinopelvic alignment and CA parameters. Conclusions: Spinopelvic alignment influences both the optimal cup orientation and its tolerance range. Incorporating these factors may allow patient-specific optimization of acetabular component positioning. Level of Evidence: Level III , retrospective cohort study. See Instructions for Authors for a complete description of levels of evidence. Clinical Relevance: Personalized component positioning based on dynamic spinopelvic alignment may help reduce dislocation risk and improve implant stability in high-risk THA patients.
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (1)
Impact of Flatback Deformity and Stiff Spinopelvic Mobility on 3-Dimensional Pelvic and Hip Kinematics After Total Hip Arthroplasty
Background: Spinopelvic abnormalities have been reported to be a risk factor for dislocation after total hip arthroplasty (THA). This study aimed to compare the kinematics of the pelvis and hip joints in patients with and without spinopelvic abnormalities after THA and to elucidate dynamic forward-leaning movement during chair-rising, which are not detectable through static radiographs. Methods: This case series included 108 hips that underwent dynamic anteroposterior radiographic imaging of the sit-to-stand motion after THA. The average age at surgery was 68 ± 10 years, with 95 hips (88%) in women (average body mass index, 23.5 ± 3.2 kg/m2). Kinematic analysis was performed to measure the anterior pelvic plane angle (APPa) and hip flexion/extension angles from seated to standing positions using model-image registration techniques. Pelvic incidence (PI) and lumbar lordosis (LL) were measured to calculate PI-LL. Results: Flatback deformity was present in 45 hips (42%) and stiff spinopelvic mobility (SPM) in 35 hips (32%), with both deformities present in 21 hips (19%). The pelvis was consistently significantly posteriorly tilted in the flatback deformity group throughout the movement compared with the normal group, with the greatest difference observed in the standing position. The hip flexion angles in the flatback deformity group showed significant extension in the standing position (7° greater than that in the normal group). For stiff SPM, a significant posterior tilt in the standing position was observed. Accordingly, the range between the maximum hip flexion and extension was 13° greater. There was no significant difference between the maximal flexion and extension centers. Conclusions: Patients with flatback deformities consistently exhibited posterior APPa, especially when standing. In stiff SPM, a large range of hip flexion and extension while chair-rising increased the risk of impingement, indicating the necessity for a wider range of motion without changing the target orientation. These findings highlight the importance of considering spinopelvic alignment when planning cup positioning in THA to minimize the risk of dislocation. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (1)
Open AccessImpact of Flatback Deformity and Stiff Spinopelvic Mobility on 3-Dimensional Pelvic and Hip Kinematics After Total Hip Arthroplasty
Background: Spinopelvic abnormalities have been reported to be a risk factor for dislocation after total hip arthroplasty (THA). This study aimed to compare the kinematics of the pelvis and hip joints in patients with and without spinopelvic abnormalities after THA and to elucidate dynamic forward-leaning movement during chair-rising, which are not detectable through static radiographs. Methods: This case series included 108 hips that underwent dynamic anteroposterior radiographic imaging of the sit-to-stand motion after THA. The average age at surgery was 68 ± 10 years, with 95 hips (88%) in women (average body mass index, 23.5 ± 3.2 kg/m2). Kinematic analysis was performed to measure the anterior pelvic plane angle (APPa) and hip flexion/extension angles from seated to standing positions using model-image registration techniques. Pelvic incidence (PI) and lumbar lordosis (LL) were measured to calculate PI-LL. Results: Flatback deformity was present in 45 hips (42%) and stiff spinopelvic mobility (SPM) in 35 hips (32%), with both deformities present in 21 hips (19%). The pelvis was consistently significantly posteriorly tilted in the flatback deformity group throughout the movement compared with the normal group, with the greatest difference observed in the standing position. The hip flexion angles in the flatback deformity group showed significant extension in the standing position (7° greater than that in the normal group). For stiff SPM, a significant posterior tilt in the standing position was observed. Accordingly, the range between the maximum hip flexion and extension was 13° greater. There was no significant difference between the maximal flexion and extension centers. Conclusions: Patients with flatback deformities consistently exhibited posterior APPa, especially when standing. In stiff SPM, a large range of hip flexion and extension while chair-rising increased the risk of impingement, indicating the necessity for a wider range of motion without changing the target orientation. These findings highlight the importance of considering spinopelvic alignment when planning cup positioning in THA to minimize the risk of dislocation. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 12 September 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-10
Comparison of in vivo knee kinematics before and after bicruciate-stabilized total knee arthroplasty during squatting
Background: No studies have directly evaluated kinematic changes during squatting before and after bicruciate-stabilized total knee arthroplasty (BCS-TKA) with the dual cam-post mechanism and asymmetric surfaces. This study investigated the effect of BCS-TKA on changes to pre- and postoperative skeletal knee kinematics, to identify factors associated with postoperative skeletal kinematic parameters. Methods: Seventeen knees in 17 patients were prospectively recruited before primary TKA for advanced medial knee osteoarthritis. Subjects underwent BCS-TKA and were evaluated more than 1 year postoperatively. In vivo dynamic skeletal knee kinematics were evaluated using periodic radiographic images collected during squatting to quantify the tibiofemoral functional extension/flexion angle, anteroposterior (AP) translation, and axial rotation angle using image-matching techniques. Rotational alignments of femoral and tibial components were measured postoperatively using computed tomography images. Results: The pre- and postoperative tibiofemoral functional extension/flexion angles during squatting were 12.2° ± 6.7°/100.1° ± 16.8° and 9.6° ± 8.6°/109.4° ± 16.8°, respectively, with a significant difference in flexion angle (p < .05). Total AP translation was significantly larger postoperatively than preoperatively (10.8 mm ± 3.7 mm vs. 14.4 mm ± 4.2 mm, respectively; p < .05). The pre- and postoperative total rotation angles were 6.6° ± 3.0° and 6.4° ± 3.7°, respectively, indicating no significant difference. The pre- and postoperative tibiofemoral functional flexion angles were significantly associated with each other (p = .0434, r = .49). The postoperative total rotation angle was significantly smaller when the total component rotational mismatch angle between the femoral and tibial components was above 5° vs. below 5° (4.6° ± 2.7° vs. 8.3° ± 3.9°, respectively; p < .05). Conclusions: BCS-TKA significantly increased the tibiofemoral functional flexion angles, with larger AP translation postoperatively. Both preoperative skeletal kinematics and surgical techniques affected the skeletal kinematics of the replaced knee. A total component rotational mismatch angle greater than 5° significantly decreased postoperative total knee rotation during squatting.
- 12 September 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-10
Open AccessComparison of in vivo knee kinematics before and after bicruciate-stabilized total knee arthroplasty during squatting
Background: No studies have directly evaluated kinematic changes during squatting before and after bicruciate-stabilized total knee arthroplasty (BCS-TKA) with the dual cam-post mechanism and asymmetric surfaces. This study investigated the effect of BCS-TKA on changes to pre- and postoperative skeletal knee kinematics, to identify factors associated with postoperative skeletal kinematic parameters. Methods: Seventeen knees in 17 patients were prospectively recruited before primary TKA for advanced medial knee osteoarthritis. Subjects underwent BCS-TKA and were evaluated more than 1 year postoperatively. In vivo dynamic skeletal knee kinematics were evaluated using periodic radiographic images collected during squatting to quantify the tibiofemoral functional extension/flexion angle, anteroposterior (AP) translation, and axial rotation angle using image-matching techniques. Rotational alignments of femoral and tibial components were measured postoperatively using computed tomography images. Results: The pre- and postoperative tibiofemoral functional extension/flexion angles during squatting were 12.2° ± 6.7°/100.1° ± 16.8° and 9.6° ± 8.6°/109.4° ± 16.8°, respectively, with a significant difference in flexion angle (p < .05). Total AP translation was significantly larger postoperatively than preoperatively (10.8 mm ± 3.7 mm vs. 14.4 mm ± 4.2 mm, respectively; p < .05). The pre- and postoperative total rotation angles were 6.6° ± 3.0° and 6.4° ± 3.7°, respectively, indicating no significant difference. The pre- and postoperative tibiofemoral functional flexion angles were significantly associated with each other (p = .0434, r = .49). The postoperative total rotation angle was significantly smaller when the total component rotational mismatch angle between the femoral and tibial components was above 5° vs. below 5° (4.6° ± 2.7° vs. 8.3° ± 3.9°, respectively; p < .05). Conclusions: BCS-TKA significantly increased the tibiofemoral functional flexion angles, with larger AP translation postoperatively. Both preoperative skeletal kinematics and surgical techniques affected the skeletal kinematics of the replaced knee. A total component rotational mismatch angle greater than 5° significantly decreased postoperative total knee rotation during squatting.
- Open Access
- 12 January 2019
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 11
Dynamic hip kinematics during recreational classical ballet and hula dance after total hip arthroplasty: two case reports
The in vivo assessment of the three-dimensional kinematics of the hip during dance activities in patients after total hip arthroplasty has not been previously reported. We evaluated the replaced hip kinematics during recreational classical ballet and hula dance using radiographic-based image-matching techniques. A 58-year-old Japanese woman (patient 1; height, 157 cm; weight, 74.5 kg) and a 73-year-old Japanese woman (patient 2; height, 153 cm; weight, 48 kg) were still doing classical ballet and hula dance, respectively, after primary total hip arthroplasty. For ballet, there were gradual three-dimensional hip movements with 48° flexion, 36° abduction, and 49° external rotation in développé and 34° flexion, 29° abduction, and 43° external rotation in plié. For hula, there were small three-dimensional hip movements with 31° flexion, 15° adduction, and 11° external rotation in kao and 17° flexion, 11° adduction, and 11° external rotation in kaholo. No liner-to-neck contact was found in any dance activities. Both classical ballet and hula dance produced complex ranges of hip movements and activity-dependent kinematics. These kinematic data could be useful for recommending each patient with total hip arthroplasty to continue recreational dance activities.
- 12 January 2019
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 11
Open AccessDynamic hip kinematics during recreational classical ballet and hula dance after total hip arthroplasty: two case reports
The in vivo assessment of the three-dimensional kinematics of the hip during dance activities in patients after total hip arthroplasty has not been previously reported. We evaluated the replaced hip kinematics during recreational classical ballet and hula dance using radiographic-based image-matching techniques. A 58-year-old Japanese woman (patient 1; height, 157 cm; weight, 74.5 kg) and a 73-year-old Japanese woman (patient 2; height, 153 cm; weight, 48 kg) were still doing classical ballet and hula dance, respectively, after primary total hip arthroplasty. For ballet, there were gradual three-dimensional hip movements with 48° flexion, 36° abduction, and 49° external rotation in développé and 34° flexion, 29° abduction, and 43° external rotation in plié. For hula, there were small three-dimensional hip movements with 31° flexion, 15° adduction, and 11° external rotation in kao and 17° flexion, 11° adduction, and 11° external rotation in kaholo. No liner-to-neck contact was found in any dance activities. Both classical ballet and hula dance produced complex ranges of hip movements and activity-dependent kinematics. These kinematic data could be useful for recommending each patient with total hip arthroplasty to continue recreational dance activities.
- 21 October 2018
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 294-300
In vivo anterior cruciate ligament length pattern assessment secondary to differences in the femoral attachment under loading condition using image-matching techniques
- 21 October 2018
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 294-300
In vivo anterior cruciate ligament length pattern assessment secondary to differences in the femoral attachment under loading condition using image-matching techniques
- Open Access
- 3 July 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 162
Dynamic hip kinematics during squatting before and after total hip arthroplasty
The difference in in vivo kinematics before and after total hip arthroplasty (THA) for the same subjects and the clearance between the liner and neck during squatting have been unclear. The purpose of the present study was to clarify (1) the changes in the in vivo kinematics between prosthetic hips and osteoarthritis hips of the same subjects and (2) the extent of the liner-to-neck clearance during squatting under weight-bearing conditions. This study consisted of 10 patients who underwent unilateral THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, we obtained continuous radiographs during squatting. We analyzed the hip joint’s movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also quantified the minimum distance at maximum flexion and extension, and the minimum angle at maximum flexion between the liner and stem neck. The maximum hip flexion angles post-THA (80.7° [range, 69.4–98.6°]) changed significantly compared with the pre-THA values (71.7° [range, 55.2°–91.2°]). The pelvic tilt angle (posterior +, anterior−) at the maximum hip flexion post-THA (10.4° [range, − 6.7° to 26.9°]) was significantly smaller than that at pre-THA (16.6° [range, − 3° to 40.3°]). The minimum anterior and posterior liner-to-neck distances averaged 10.9 and 8.0 mm, respectively, which was a significant difference. The minimum liner-to-neck angle at maximum flexion averaged 34.7° (range, 20.7°–46.3°). No liner-to-neck contact occurred in any of the hips. THA increased the range of hip joint motion and the pelvis tilted anteriorly more after than before THA, with sufficient liner-to-neck clearance during squatting. These data may be beneficial for advising patients after THA regarding postoperative activity restrictions in daily life.
- 3 July 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 162
Open AccessDynamic hip kinematics during squatting before and after total hip arthroplasty
The difference in in vivo kinematics before and after total hip arthroplasty (THA) for the same subjects and the clearance between the liner and neck during squatting have been unclear. The purpose of the present study was to clarify (1) the changes in the in vivo kinematics between prosthetic hips and osteoarthritis hips of the same subjects and (2) the extent of the liner-to-neck clearance during squatting under weight-bearing conditions. This study consisted of 10 patients who underwent unilateral THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, we obtained continuous radiographs during squatting. We analyzed the hip joint’s movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also quantified the minimum distance at maximum flexion and extension, and the minimum angle at maximum flexion between the liner and stem neck. The maximum hip flexion angles post-THA (80.7° [range, 69.4–98.6°]) changed significantly compared with the pre-THA values (71.7° [range, 55.2°–91.2°]). The pelvic tilt angle (posterior +, anterior−) at the maximum hip flexion post-THA (10.4° [range, − 6.7° to 26.9°]) was significantly smaller than that at pre-THA (16.6° [range, − 3° to 40.3°]). The minimum anterior and posterior liner-to-neck distances averaged 10.9 and 8.0 mm, respectively, which was a significant difference. The minimum liner-to-neck angle at maximum flexion averaged 34.7° (range, 20.7°–46.3°). No liner-to-neck contact occurred in any of the hips. THA increased the range of hip joint motion and the pelvis tilted anteriorly more after than before THA, with sufficient liner-to-neck clearance during squatting. These data may be beneficial for advising patients after THA regarding postoperative activity restrictions in daily life.
- Open Access
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Dynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Open AccessDynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 5 December 2015
- Published by Elsevier in Clinical Biomechanics
- Vol. 32, 150-156
Dynamic hip kinematics in patients with hip osteoarthritis during weight-bearing activities
- 5 December 2015
- Published by Elsevier in Clinical Biomechanics
- Vol. 32, 150-156
Dynamic hip kinematics in patients with hip osteoarthritis during weight-bearing activities
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S731-731
POLYVINYL FORMAL AS ARTIFICIAL ARTICULAR CARTILAGE
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S731-731
POLYVINYL FORMAL AS ARTIFICIAL ARTICULAR CARTILAGE
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S457-457
Development of a novel three-dimensional culture system to study the role of mechanically damaged osteocytes in the initiation of targeted bone remodeling
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S457-457
Development of a novel three-dimensional culture system to study the role of mechanically damaged osteocytes in the initiation of targeted bone remodeling