Juan J. Arias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juan J. Arias has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
F. Jiménez
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, La Laguna, Tenerife, Spain
5 shared publications- Ana I Jiménez
Universidad de La Laguna, Facultad de Química, Departamento de Química Analítica, Nutrìción y Bromatología, E-38204 La Laguna, Tenerife, Spain
3 shared publications Francisco Jiménez
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química , Universidad de La Laguna , La Laguna, Tenerife, Spain
3 shared publications- José M. García Fraga
Departamento de Quı́mica Analı́tica, Nutrición y Bromatologı́a, Facultad de Quı́mica, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
3 shared publications - Ana Isabel Jiménez Abizanda
Departamento de Química Analítica, Bromatología y Toxicología, Facultad de Química, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
2 shared publications E. Martín
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, La Laguna, Tenerife, Spain
2 shared publications
Latest Publications
- 1 January 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (2) , 257-280
Selection of Wavelength Range and Number of Factors to be Used in the PLS Treatment of Spectrophotometric Data
A procedure for selection of wavelength range and number of factors to be used in partial least square calibration that involves the calculation of prediction residual sum of squares (PRESS) in different conditions is proposed. The best model takes into account the minimum PRESS value that does not show significant differences with respect to the corresponding model with fewer factors. The ability of the proposed method to minimize errors in partial least squares (PLS) prediction is demonstrated by applying it to the resolution of phenytoine (DPH) and phenobarbital (PB) binary mixtures with errors less than 2.8%; the results are compared with those obtained using another wavelength selection procedure. The ensuing method, which was validated by high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).
- 1 January 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (2) , 257-280
Selection of Wavelength Range and Number of Factors to be Used in the PLS Treatment of Spectrophotometric Data
A procedure for selection of wavelength range and number of factors to be used in partial least square calibration that involves the calculation of prediction residual sum of squares (PRESS) in different conditions is proposed. The best model takes into account the minimum PRESS value that does not show significant differences with respect to the corresponding model with fewer factors. The ability of the proposed method to minimize errors in partial least squares (PLS) prediction is demonstrated by applying it to the resolution of phenytoine (DPH) and phenobarbital (PB) binary mixtures with errors less than 2.8%; the results are compared with those obtained using another wavelength selection procedure. The ensuing method, which was validated by high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).
Simultaneous spectrophotometric determination of diuretics by using multivariate calibration methods
- 9 May 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (6) , 1159-1165
Use of partial least-squares regression for multicomponent determinations based on kinetic spectrofluorimetric data. Simultaneous determination of canrenone and spironolactone in urine
A new spectrofluorimetric method for the simultaneous determination of canrenone and spironolactone in urine is proposed. The method is based on the different rates at which the two analytes react with hot sulfuric acid to form a trienone. The kinetic spectrofluorimetric data are processed by partial least-squares regression. The effects of sulfuric acid concentration and temperature on the system under study were also evaluated and the optimum values for carring out the reaction were 50% and 50 °C, respectively. The method was checked by analyzing urine samples that they contained both diuretics. The accuracy and the precision of the method were tested. The relative standard errors in the quantification of each analyte in all tested samples were 3.69 and 3.59%. The proposed method was validated by comparison with a high performance liquid chromatographic method for urine samples.
- 9 May 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (6) , 1159-1165
Use of partial least-squares regression for multicomponent determinations based on kinetic spectrofluorimetric data. Simultaneous determination of canrenone and spironolactone in urine
A new spectrofluorimetric method for the simultaneous determination of canrenone and spironolactone in urine is proposed. The method is based on the different rates at which the two analytes react with hot sulfuric acid to form a trienone. The kinetic spectrofluorimetric data are processed by partial least-squares regression. The effects of sulfuric acid concentration and temperature on the system under study were also evaluated and the optimum values for carring out the reaction were 50% and 50 °C, respectively. The method was checked by analyzing urine samples that they contained both diuretics. The accuracy and the precision of the method were tested. The relative standard errors in the quantification of each analyte in all tested samples were 3.69 and 3.59%. The proposed method was validated by comparison with a high performance liquid chromatographic method for urine samples.
- Open Access
- 1 September 1999
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 82 (5) , 1054-1063
Simultaneous Determination of Chlorthalidone and Spironolactone with Univariate and Multivariate Calibration: Wavelength Range Selection
Chlorthalidone and spironolactone were determined simultaneously with the aid of univariate and multivariate calibration methods. Univariate calibration was performed by the zero-crossing and derivative ratio spectrum methods. Extensive spectral overlap and the scarcity of wavelengths in derivative spectra allowing one analyte to be distinguished and quantitated in the presence of the other gave rise to poor results that called for multivariate calibration. Partial least-squares regression was used in combination with a suitable method for selecting the optimum wavelength range and number of factors for analysis. The ensuing method was applied to simultaneous determination of chlorthalidone and spironolactone in a commercially available pharmaceutical preparation. The results were validated by high-performance liquid chromatography.
- 1 September 1999
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 82 (5) , 1054-1063
Open AccessSimultaneous Determination of Chlorthalidone and Spironolactone with Univariate and Multivariate Calibration: Wavelength Range Selection
Chlorthalidone and spironolactone were determined simultaneously with the aid of univariate and multivariate calibration methods. Univariate calibration was performed by the zero-crossing and derivative ratio spectrum methods. Extensive spectral overlap and the scarcity of wavelengths in derivative spectra allowing one analyte to be distinguished and quantitated in the presence of the other gave rise to poor results that called for multivariate calibration. Partial least-squares regression was used in combination with a suitable method for selecting the optimum wavelength range and number of factors for analysis. The ensuing method was applied to simultaneous determination of chlorthalidone and spironolactone in a commercially available pharmaceutical preparation. The results were validated by high-performance liquid chromatography.
- 1 February 1997
- Published by Taylor & Francis in Analytical Letters
- Vol. 30 (3) , 633-644
Spectrofluorimetric Determination of Germanium Traces Using 1,2,4-Trihydroxyantraquinone
A new spectrofluorimetric method for determination of germanium traces based on its reaction with 1,2,4-Trihydroxyantraquinone, at an apparent pH 8.8 provided by an ammonia/ammonium chloride buffer, in a 80:20(v/v) ethyleneglycol water medium is proposed. The calibration graph is linear over the range 70–725 ng/ml and features a detection limit of 2.5 ng/ml. The effect of potential major interferences has been investigated and the proposed method was successfully applied to the determination of germanium in synthetic samples and industrial concentrates, after extraction with CCl4, in an 9 M HCl medium.
- 1 February 1997
- Published by Taylor & Francis in Analytical Letters
- Vol. 30 (3) , 633-644
Spectrofluorimetric Determination of Germanium Traces Using 1,2,4-Trihydroxyantraquinone
A new spectrofluorimetric method for determination of germanium traces based on its reaction with 1,2,4-Trihydroxyantraquinone, at an apparent pH 8.8 provided by an ammonia/ammonium chloride buffer, in a 80:20(v/v) ethyleneglycol water medium is proposed. The calibration graph is linear over the range 70–725 ng/ml and features a detection limit of 2.5 ng/ml. The effect of potential major interferences has been investigated and the proposed method was successfully applied to the determination of germanium in synthetic samples and industrial concentrates, after extraction with CCl4, in an 9 M HCl medium.
- 1 July 1994
- Published by Taylor & Francis in Analytical Letters
- Vol. 27 (9) , 1763-1777
Application of the Multiple Linear Regression Method to Differential Pulse Polarography
The Multiple Linear Regression method has been used for treatment of the highly overlapped peaks obtained from the binary mixtures Cd-Ni and the ternary mixture Cd-Ni-Cu in KSCN 1 M and pH = 4.5 (Britton-Robinson buffer) by Differential Pulse Polarography. Metal concentrations were within the range of 6.8 to 33.2 μ.M for Cadmium and of 6.4 30.4 μM for Nickel and Copper. The obtained results prove that the hard multivariate calibration models such as Multiple Linear Regression can be applied in Differential Pulse Polarography when the baseline is subtracted; in addition, both the fitting parameters and relative errors are much better when the smoothed polarograms are used.
- 1 July 1994
- Published by Taylor & Francis in Analytical Letters
- Vol. 27 (9) , 1763-1777
Application of the Multiple Linear Regression Method to Differential Pulse Polarography
The Multiple Linear Regression method has been used for treatment of the highly overlapped peaks obtained from the binary mixtures Cd-Ni and the ternary mixture Cd-Ni-Cu in KSCN 1 M and pH = 4.5 (Britton-Robinson buffer) by Differential Pulse Polarography. Metal concentrations were within the range of 6.8 to 33.2 μ.M for Cadmium and of 6.4 30.4 μM for Nickel and Copper. The obtained results prove that the hard multivariate calibration models such as Multiple Linear Regression can be applied in Differential Pulse Polarography when the baseline is subtracted; in addition, both the fitting parameters and relative errors are much better when the smoothed polarograms are used.
- 1 November 1993
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 26 (9) , 1583-1594
Spectrofluorimetric Determination Of Indium with 1,2,4-Trihydroxyanthraquinone
A new method for the spectrofluorimetric determination of indium by formation of a fluorescent 1:1 complex with 1,2,4-trihydroxyanthraquinone is proposed. The complex is formed in a mixed, 60:40 v/v acetone-water medium at pH 3.8 provided by an acetic acid-sodium acetate buffer. The calibration graph is linear between 10 and 600 ng/ml. The effect of potential interferents on the determination was assessed and the proposed method was applied to the determination of indium in synthetic samples.
- 1 November 1993
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 26 (9) , 1583-1594
Spectrofluorimetric Determination Of Indium with 1,2,4-Trihydroxyanthraquinone
A new method for the spectrofluorimetric determination of indium by formation of a fluorescent 1:1 complex with 1,2,4-trihydroxyanthraquinone is proposed. The complex is formed in a mixed, 60:40 v/v acetone-water medium at pH 3.8 provided by an acetic acid-sodium acetate buffer. The calibration graph is linear between 10 and 600 ng/ml. The effect of potential interferents on the determination was assessed and the proposed method was applied to the determination of indium in synthetic samples.
- 1 August 1992
- Published by Taylor & Francis in Analytical Letters
- Vol. 25 (8) , 1511-1524
Simultaneous Determination of Perphenazine and Amitriptyline by Derivative Spectrophotometry
Two methods have been developed for the simultaneous determination of Amitryptiline and Perphenazine: the zero-crossing (I) and the derivative ratio spectrum (II) methods and both use the derivative spectrophotometry. The methods have been applicable in the ranges of 1 to 30 μg·ml−1 of Amitryptiline (I and II) and between 1 and 8 μg·ml−1 and from 1 to 7 μg·ml−1 of Perphenazine for the methods I and II respectively. The accuracy of the proposed methods have been studied and they have been used in the determination of Amitryptiline and Perphenazine in commercially available pharmaceuticals.
- 1 August 1992
- Published by Taylor & Francis in Analytical Letters
- Vol. 25 (8) , 1511-1524
Simultaneous Determination of Perphenazine and Amitriptyline by Derivative Spectrophotometry
Two methods have been developed for the simultaneous determination of Amitryptiline and Perphenazine: the zero-crossing (I) and the derivative ratio spectrum (II) methods and both use the derivative spectrophotometry. The methods have been applicable in the ranges of 1 to 30 μg·ml−1 of Amitryptiline (I and II) and between 1 and 8 μg·ml−1 and from 1 to 7 μg·ml−1 of Perphenazine for the methods I and II respectively. The accuracy of the proposed methods have been studied and they have been used in the determination of Amitryptiline and Perphenazine in commercially available pharmaceuticals.