José M. García Fraga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
José M. García Fraga has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Ana Isabel Jiménez Abizanda
Departamento de Química Analítica, Bromatología y Toxicología, Facultad de Química, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
7 shared publications F. Jiménez
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, E-38071 La Laguna, Tenerife, Spain
3 shared publicationsFrancisco Jiménez
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química , Universidad de La Laguna , La Laguna, Tenerife, Spain
3 shared publications- Francisco Jiménez-Moreno
Laboratorio de Materiales para Análisis Químicos (MAT4LL), Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, 38206 Tenerife, Spain
3 shared publications J.J. Arias
Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Química, Universidad de La Laguna, E-38071 La Laguna, Tenerife, Spain
3 shared publications- Juan J. Arias
Departamento de Quı́mica Analı́tica, Nutrición y Bromatologı́a, Facultad de Quı́mica, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
3 shared publications
Latest Publications
- 25 May 2019
- Published by Elsevier in Journal of Volcanology and Geothermal Research
- Vol. 381, 32-43
Geochemical signals related to the 2011–2012 El Hierro submarine eruption
- 25 May 2019
- Published by Elsevier in Journal of Volcanology and Geothermal Research
- Vol. 381, 32-43
Geochemical signals related to the 2011–2012 El Hierro submarine eruption
- 27 March 2019
- Published by Springer Nature in Pure and Applied Geophysics
- Vol. 176 (8) , 3467-3485
Spatial and Temporal Analysis of Temperature and Gaseous Emission Inside a Gallery in An Active Volcanic Island (Tenerife, Canary Islands)
- 27 March 2019
- Published by Springer Nature in Pure and Applied Geophysics
- Vol. 176 (8) , 3467-3485
Spatial and Temporal Analysis of Temperature and Gaseous Emission Inside a Gallery in An Active Volcanic Island (Tenerife, Canary Islands)
- 1 April 2017
- Published by Elsevier in Small Ruminant Research
- Vol. 149, 52-61
Effect of the inclusion of banana silage in the diet of goats on physicochemical and sensory characteristics of cheeses at different ripening times
- 1 April 2017
- Published by Elsevier in Small Ruminant Research
- Vol. 149, 52-61
Effect of the inclusion of banana silage in the diet of goats on physicochemical and sensory characteristics of cheeses at different ripening times
- 1 May 2014
- Published by Elsevier in Food Chemistry
- Vol. 151, 133-140
Characterization of toasted cereal flours from the Canary Islands (gofios)
- 1 May 2014
- Published by Elsevier in Food Chemistry
- Vol. 151, 133-140
Characterization of toasted cereal flours from the Canary Islands (gofios)
- 1 January 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (2) , 257-280
Selection of Wavelength Range and Number of Factors to be Used in the PLS Treatment of Spectrophotometric Data
A procedure for selection of wavelength range and number of factors to be used in partial least square calibration that involves the calculation of prediction residual sum of squares (PRESS) in different conditions is proposed. The best model takes into account the minimum PRESS value that does not show significant differences with respect to the corresponding model with fewer factors. The ability of the proposed method to minimize errors in partial least squares (PLS) prediction is demonstrated by applying it to the resolution of phenytoine (DPH) and phenobarbital (PB) binary mixtures with errors less than 2.8%; the results are compared with those obtained using another wavelength selection procedure. The ensuing method, which was validated by high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).
- 1 January 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (2) , 257-280
Selection of Wavelength Range and Number of Factors to be Used in the PLS Treatment of Spectrophotometric Data
A procedure for selection of wavelength range and number of factors to be used in partial least square calibration that involves the calculation of prediction residual sum of squares (PRESS) in different conditions is proposed. The best model takes into account the minimum PRESS value that does not show significant differences with respect to the corresponding model with fewer factors. The ability of the proposed method to minimize errors in partial least squares (PLS) prediction is demonstrated by applying it to the resolution of phenytoine (DPH) and phenobarbital (PB) binary mixtures with errors less than 2.8%; the results are compared with those obtained using another wavelength selection procedure. The ensuing method, which was validated by high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).
- 1 December 2005
- Published by Elsevier in Food Chemistry
- Vol. 93 (3) , 449-458
Characterization of honey from the Canary Islands: determination of the mineral content by atomic absorption spectrophotometry
- 1 December 2005
- Published by Elsevier in Food Chemistry
- Vol. 93 (3) , 449-458
Characterization of honey from the Canary Islands: determination of the mineral content by atomic absorption spectrophotometry
- 31 August 2001
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 24 (13) , 1921-1928
CAPILLARY ZONE ELECTROPHORESIS ANALYSIS OF ANTI-EPILEPTIC DRUGS
This paper describes the development of a simple, reliable, reproducible, and fast method, based on capillary zone electrophoresis with diode array detection, for the separation and determination of two antiepileptic drugs. Phenytoin (DPH) and phenobarbital (PB) were separated in 4 min by using a carrier containing glycine 50 mM, pH 10.5. The limit of detection was 0.1μg mL−1 for both compounds. Satisfactory reproducibility was obtained for migration times (<1.4%) and corrected peak areas (<6.9%) in the analysis of pharmaceutical formulations. The average recoveries obtained, which ranged between 100 and 108%, testify to the accuracy of the proposed method.
- 31 August 2001
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 24 (13) , 1921-1928
CAPILLARY ZONE ELECTROPHORESIS ANALYSIS OF ANTI-EPILEPTIC DRUGS
This paper describes the development of a simple, reliable, reproducible, and fast method, based on capillary zone electrophoresis with diode array detection, for the separation and determination of two antiepileptic drugs. Phenytoin (DPH) and phenobarbital (PB) were separated in 4 min by using a carrier containing glycine 50 mM, pH 10.5. The limit of detection was 0.1μg mL−1 for both compounds. Satisfactory reproducibility was obtained for migration times (<1.4%) and corrected peak areas (<6.9%) in the analysis of pharmaceutical formulations. The average recoveries obtained, which ranged between 100 and 108%, testify to the accuracy of the proposed method.
Simultaneous spectrophotometric determination of diuretics by using multivariate calibration methods
- 1 January 1999
- Published by Taylor & Francis in Analytical Letters
- Vol. 32 (12) , 2489-2505
Influence of the Selected Wavelength Range on the Simultaneous Spectrophotometric Determination of Mixture Components by Use of Partial Least-Squares Regression
This paper shows the benefits of optimizing the wavelength range and number of factors used in the simultaneous spectrophotometric determination of several analytes in the same sample by use of partial least-squares regression. The optimization criterion used for this purpose is based on the relative standard error of prediction (RSEP), which represents the overall error for a series of mixtures containing different amounts of the analytes; the optimum wavelength range and number of factors are chosen to be those leading to the lowest RSEP value. The ensuing method was applied to the simultaneous determination of the diuretics spironolactone and althiazide at concentrations between 2 and 20 μg · mL−1 in synthetic samples, where the drugs were quantified with errors less than 5% (spironolactone) and 2.5% (althiazide), and relative standard deviations below 3.5 and 0.8%, respectively. Both drugs were also determined in a pharmaceutical preparation, with recoveries of 100.76% (spironolactone) and 95.86% (althiazide) relative to their nominal contents, and relative standard deviations of 1.1 and 3.5%, respectively. The proposed method for the analysis of the pharmaceutical preparation was validated by HPLC.
- 1 January 1999
- Published by Taylor & Francis in Analytical Letters
- Vol. 32 (12) , 2489-2505
Influence of the Selected Wavelength Range on the Simultaneous Spectrophotometric Determination of Mixture Components by Use of Partial Least-Squares Regression
This paper shows the benefits of optimizing the wavelength range and number of factors used in the simultaneous spectrophotometric determination of several analytes in the same sample by use of partial least-squares regression. The optimization criterion used for this purpose is based on the relative standard error of prediction (RSEP), which represents the overall error for a series of mixtures containing different amounts of the analytes; the optimum wavelength range and number of factors are chosen to be those leading to the lowest RSEP value. The ensuing method was applied to the simultaneous determination of the diuretics spironolactone and althiazide at concentrations between 2 and 20 μg · mL−1 in synthetic samples, where the drugs were quantified with errors less than 5% (spironolactone) and 2.5% (althiazide), and relative standard deviations below 3.5 and 0.8%, respectively. Both drugs were also determined in a pharmaceutical preparation, with recoveries of 100.76% (spironolactone) and 95.86% (althiazide) relative to their nominal contents, and relative standard deviations of 1.1 and 3.5%, respectively. The proposed method for the analysis of the pharmaceutical preparation was validated by HPLC.