Riccardo Fenici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Riccardo Fenici has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Donatella Brisinda
Catholic University of the Sacred Heart, Biomagnetism Center, Clinical Physiology , Rome , Italy
9 shared publications- Donatella Brisinda
Clinical Physiology-Biomagnetism Center, Catholic University of Sacred Heart, Rome, Italy
7 shared publications Angela Venuti
5 shared publicationsPeter Fenici
Centro di Biomagnetismo-Fisiologia Clinica, Università Cattolica del S. Cuore, Rome, Italy
5 shared publicationsJukka Nenonen
Medical Engineering Center, BioMag Laboratory, University Central Hospital, Helsinki, Finland
4 shared publicationsAnna Maria Meloni
3 shared publications
Latest Publications
- 1 August 2017
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 27 (8) , 711-716
Compliance in weight control reduces atrial fibrillation worsening: A retrospective cohort study
- 1 August 2017
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 27 (8) , 711-716
Compliance in weight control reduces atrial fibrillation worsening: A retrospective cohort study
- Open Access
- 10 January 2015
- Published by Sciencedomain International in Cardiology and Angiology: An International Journal
- Vol. 4 (1) , 25-36
Non-linear Analysis of Heart Rate Variability Improves Differential Diagnosis between Parkinson Disease and Multiple System Atrophy
Autonomic nervous system; Parkinson disease; multiple system atrophy; non linear HRV analysis; discriminant analysis.
- 10 January 2015
- Published by Sciencedomain International in Cardiology and Angiology: An International Journal
- Vol. 4 (1) , 25-36
Open AccessNon-linear Analysis of Heart Rate Variability Improves Differential Diagnosis between Parkinson Disease and Multiple System Atrophy
Autonomic nervous system; Parkinson disease; multiple system atrophy; non linear HRV analysis; discriminant analysis.
- Open Access
- 17 June 2014
- Published by BMJ in Open Heart
- Vol. 1 (1) , e000063
Heart rate variability analysis during head-up tilt test predicts nitroglycerine-induced syncope
Objective: The aim of this study was to determine whether or not heart rate variability (HRV) analysis during the first 20 min of head-up tilt testing could predict whether patients will develop syncope after nitroglycerine administration. Design: 64 patients with previous loss of consciousness underwent head-up tilt testing with the Italian protocol, which involves the administration of nitroglycerine after 20 min of tilt. HRV parameters were analysed from 5 min intervals selected during pretest supine rest (phase 1), the first 5 min (phase 2) and the last 5 min (phase 3) of passive 20 min of tilting, prior to the administration of nitroglycerine. Differences in power (ms2) of the spectral components between the various phases of tilting were calculated for each patient and expressed as Δ. Results: 20 patients (group 1, 9 women, mean age 43.2±24.5 years) had a syncope during tilt testing after nitroglycerine, while the other 44 (group 2, 24 women, mean age 41±20.5 years) did not. In group 1, the HRV spectral parameters high frequency (HF) and total power (TP) had a significant decrement from phases 2 to 3 (p=0.012 and 0.027, respectively), while in group 2 the average HF and TP values did not change. The Δ of spectral parameters between phases 2 and 3 were able to differentiate between the two groups and to predict syncope after nitroglycerine administration (p<0.05). Conclusions: HRV analysis within the first 20 min of passive tilting demonstrated that patients with nitroglycerine-induced syncope are characterised by a progressive decrement of parasympathetic activity, which does not occur in patients with a negative response to nitroglycerine. If confirmed on a wider population, HRV analysis could replace nitroglycerine administration and shorten the duration of the tilt test.
- 17 June 2014
- Published by BMJ in Open Heart
- Vol. 1 (1) , e000063
Open AccessHeart rate variability analysis during head-up tilt test predicts nitroglycerine-induced syncope
Objective: The aim of this study was to determine whether or not heart rate variability (HRV) analysis during the first 20 min of head-up tilt testing could predict whether patients will develop syncope after nitroglycerine administration. Design: 64 patients with previous loss of consciousness underwent head-up tilt testing with the Italian protocol, which involves the administration of nitroglycerine after 20 min of tilt. HRV parameters were analysed from 5 min intervals selected during pretest supine rest (phase 1), the first 5 min (phase 2) and the last 5 min (phase 3) of passive 20 min of tilting, prior to the administration of nitroglycerine. Differences in power (ms2) of the spectral components between the various phases of tilting were calculated for each patient and expressed as Δ. Results: 20 patients (group 1, 9 women, mean age 43.2±24.5 years) had a syncope during tilt testing after nitroglycerine, while the other 44 (group 2, 24 women, mean age 41±20.5 years) did not. In group 1, the HRV spectral parameters high frequency (HF) and total power (TP) had a significant decrement from phases 2 to 3 (p=0.012 and 0.027, respectively), while in group 2 the average HF and TP values did not change. The Δ of spectral parameters between phases 2 and 3 were able to differentiate between the two groups and to predict syncope after nitroglycerine administration (p<0.05). Conclusions: HRV analysis within the first 20 min of passive tilting demonstrated that patients with nitroglycerine-induced syncope are characterised by a progressive decrement of parasympathetic activity, which does not occur in patients with a negative response to nitroglycerine. If confirmed on a wider population, HRV analysis could replace nitroglycerine administration and shorten the duration of the tilt test.
- 31 January 2014
- Published by Springer Nature in Journal of Police and Criminal Psychology
- Vol. 30 (2) , 71-86
Real-time Imaging of Stress-induced Cardiac Autonomic Adaptation During Realistic Force-on-force Police Scenarios
- 31 January 2014
- Published by Springer Nature in Journal of Police and Criminal Psychology
- Vol. 30 (2) , 71-86
Real-time Imaging of Stress-induced Cardiac Autonomic Adaptation During Realistic Force-on-force Police Scenarios
- 1 January 2014
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 336 (1-2) , 197-202
Cardiovascular autonomic nervous system evaluation in Parkinson disease and multiple system atrophy
- 1 January 2014
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 336 (1-2) , 197-202
Cardiovascular autonomic nervous system evaluation in Parkinson disease and multiple system atrophy
- 1 October 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 168 (5) , 5113-5115
Thirty years of clinical magnetocardiography at the Catholic University of Rome: Diagnostic value and new perspectives for the treatment of cardiac arrhythmias
- 1 October 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 168 (5) , 5113-5115
Thirty years of clinical magnetocardiography at the Catholic University of Rome: Diagnostic value and new perspectives for the treatment of cardiac arrhythmias
- 12 May 2011
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 8 (4) , 333-337
Prevalence of virulent Helicobacter pylori strains in patients affected by idiopathic dysrhythmias
Helicobacter pylori virulent strains have been shown to affect cardiovascular diseases through molecular mimicry mechanisms. Silent autoimmune myocarditis has been hypothesized to be the cause of idiopathic dysrhythmias (IA). The aim of this study is to assess the prevalence of virulent H. pylori strains in patients affected by IA. In this study,54 patients (40 men, mean age 44 ± 17 years) affected by IA and 50 healthy subjects (34 men, mean age 45 ± 9) were evaluated. IA, defined as dysrhythmias with no evidence of other cardiac pathology, were either supraventricular (SVA, 23 patients; mean age 45 ± 15 years) or ventricular (VA, 31 patients; mean age 42 ± 18 years). H. pylori infection and gastrointestinal (GI) symptoms were evaluated. H. pylori strains expressing the cytotoxin-associated gene A (cagA) and the vacuolating-cytotoxin A (vacA) were also assessed through western blot. The prevalence of H. pylori is similar in IA patients and in controls (42 vs. 44%; p > 0.05); H. pylori infection is observed in 48 and 39% of the patients are affected by SVA and VA, respectively. The prevalence of CagA-positive strains is increased in IA patients compared to controls (65 vs. 42%; p < 0.01); similarly, the prevalence of VacA-positive strains is also increased in IA patients (74 vs. 46%; p < 0.006). Excluding belching, infected patients did not show any difference in GI symptoms, when compared to non-infected subjects. From this study it is concluded that there is an epidemiological link between CagA and VacA-positive H. pylori strains in IA patients.
- 12 May 2011
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 8 (4) , 333-337
Prevalence of virulent Helicobacter pylori strains in patients affected by idiopathic dysrhythmias
Helicobacter pylori virulent strains have been shown to affect cardiovascular diseases through molecular mimicry mechanisms. Silent autoimmune myocarditis has been hypothesized to be the cause of idiopathic dysrhythmias (IA). The aim of this study is to assess the prevalence of virulent H. pylori strains in patients affected by IA. In this study,54 patients (40 men, mean age 44 ± 17 years) affected by IA and 50 healthy subjects (34 men, mean age 45 ± 9) were evaluated. IA, defined as dysrhythmias with no evidence of other cardiac pathology, were either supraventricular (SVA, 23 patients; mean age 45 ± 15 years) or ventricular (VA, 31 patients; mean age 42 ± 18 years). H. pylori infection and gastrointestinal (GI) symptoms were evaluated. H. pylori strains expressing the cytotoxin-associated gene A (cagA) and the vacuolating-cytotoxin A (vacA) were also assessed through western blot. The prevalence of H. pylori is similar in IA patients and in controls (42 vs. 44%; p > 0.05); H. pylori infection is observed in 48 and 39% of the patients are affected by SVA and VA, respectively. The prevalence of CagA-positive strains is increased in IA patients compared to controls (65 vs. 42%; p < 0.01); similarly, the prevalence of VacA-positive strains is also increased in IA patients (74 vs. 46%; p < 0.006). Excluding belching, infected patients did not show any difference in GI symptoms, when compared to non-infected subjects. From this study it is concluded that there is an epidemiological link between CagA and VacA-positive H. pylori strains in IA patients.
- 1 July 2007
- p. 23-8
Magnetocardiography provides non-invasive three-dimensional electroanatomical imaging of cardiac electrophysiology.
More than two decades of research work have shown that magnetocardiographic mapping (MCG) is reliable for non-invasive three-dimensional electroanatomical imaging (3D-EAI) of arrhythmogenic substrates. Magnetocardiographic mapping is now become appealing to interventional electrophysiologists after recent evidence that MCG-based dynamic imaging of atrial arrhythmias could be useful to classify patients with atrial fibrillation (AF) before ablation and to plan the most appropriate therapeutic approach. This article will review some key-points of 3D-EAI and discuss what is still missing to favor clinical applicability of MCG-based 3D-EAI. Magnetocardiographic mapping is performed with a 36-channel unshielded mapping system, based on DC-SQUID sensors coupled to second-order axial gradiometers (pick-up coil 19 mm and 55-70 mm baselines; sensitivity of 20 fT/Sqrt[Hz] in above 1 Hz), as part of the electrophysiologic investigation protocol, tailored to the diagnostic need of each arrhythmic patient. More than 500 arrhythmic patients have been investigated so far. The MCG-based 3D-EAI has proven useful to localize well-confined arrhythmogenic substrates, such as focal ventricular tachycardia or preexcitation, to understand some causes for ablation failure, to study atrial electrophysiology including spectral analysis and localization of dominant frequency components of AF. However, MCG is still missing software tools for automatic and/or interactive 3D imaging, and multimodal data fusion equivalent to those provided with systems for invasive 3D electroanatomical mapping. Since there is an increasing trend to favor interventional treatment of arrhythmias, clinical application of MCG 3D-EAI is foreseen to improve preoperative selection of patients, to plan the appropriate interventional approach and to reduce ablation failure.
- 1 July 2007
- p. 23-8
Magnetocardiography provides non-invasive three-dimensional electroanatomical imaging of cardiac electrophysiology.
More than two decades of research work have shown that magnetocardiographic mapping (MCG) is reliable for non-invasive three-dimensional electroanatomical imaging (3D-EAI) of arrhythmogenic substrates. Magnetocardiographic mapping is now become appealing to interventional electrophysiologists after recent evidence that MCG-based dynamic imaging of atrial arrhythmias could be useful to classify patients with atrial fibrillation (AF) before ablation and to plan the most appropriate therapeutic approach. This article will review some key-points of 3D-EAI and discuss what is still missing to favor clinical applicability of MCG-based 3D-EAI. Magnetocardiographic mapping is performed with a 36-channel unshielded mapping system, based on DC-SQUID sensors coupled to second-order axial gradiometers (pick-up coil 19 mm and 55-70 mm baselines; sensitivity of 20 fT/Sqrt[Hz] in above 1 Hz), as part of the electrophysiologic investigation protocol, tailored to the diagnostic need of each arrhythmic patient. More than 500 arrhythmic patients have been investigated so far. The MCG-based 3D-EAI has proven useful to localize well-confined arrhythmogenic substrates, such as focal ventricular tachycardia or preexcitation, to understand some causes for ablation failure, to study atrial electrophysiology including spectral analysis and localization of dominant frequency components of AF. However, MCG is still missing software tools for automatic and/or interactive 3D imaging, and multimodal data fusion equivalent to those provided with systems for invasive 3D electroanatomical mapping. Since there is an increasing trend to favor interventional treatment of arrhythmias, clinical application of MCG 3D-EAI is foreseen to improve preoperative selection of patients, to plan the appropriate interventional approach and to reduce ablation failure.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S151-S155
Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up
Background: Ventricular preexcitation (VPx) is usually localized noninvasively by means of electrocardiogram (ECG) algorithms, which vary in their concordance levels. Contactless magnetocardiography (MCG) has been used as an alternate 3‐dimensional (3D) method of accessory pathways (AP) localization. The sensitivity of MCG can be increased for preoperative evaluations and planning of ablation procedures by combining it with transesophageal pacing (TEP) and electrophysiological (EP) studies. This study compared the accuracy of VPx localization with MCG with ECG algorithms, and examined the increment in diagnostic accuracy achievable with TEP. Methods: Multisite mapping from the anterior chest wall was performed with a 36‐channel MCG system. TEP allowed the evaluation of anterograde conduction properties and inducibility of arrhythmias. The reproducibility of the test and follow‐up was examined in 88 patients with Wolff–Parkinson–White (WPW) syndrome. The accuracy of MCG localization was reevaluated during pacing‐induced maximal VPx in 36 patients in whom, during MCG, the degree of VPx was highest during TEP. The gold standard for validation was effective ablation of the AP. Results: The MCG classification of VPx was accurate in 94% of AP, versus 64% and 67% with ECG, during sinus rhythm and during pacing‐induced maximal VPx, respectively. In 4.5% of cases with unclear ECG localization, MCG suggested a complex septal VPx. In all patients with successful ablations, the 3D MCG localization of the AP corresponded to the ablation site. Conclusions: MCG was more accurate than ECG for the classification of VPx and provided additional information in the non‐invasive EP assessment of patients with WPW syndrome.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S151-S155
Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up
Background: Ventricular preexcitation (VPx) is usually localized noninvasively by means of electrocardiogram (ECG) algorithms, which vary in their concordance levels. Contactless magnetocardiography (MCG) has been used as an alternate 3‐dimensional (3D) method of accessory pathways (AP) localization. The sensitivity of MCG can be increased for preoperative evaluations and planning of ablation procedures by combining it with transesophageal pacing (TEP) and electrophysiological (EP) studies. This study compared the accuracy of VPx localization with MCG with ECG algorithms, and examined the increment in diagnostic accuracy achievable with TEP. Methods: Multisite mapping from the anterior chest wall was performed with a 36‐channel MCG system. TEP allowed the evaluation of anterograde conduction properties and inducibility of arrhythmias. The reproducibility of the test and follow‐up was examined in 88 patients with Wolff–Parkinson–White (WPW) syndrome. The accuracy of MCG localization was reevaluated during pacing‐induced maximal VPx in 36 patients in whom, during MCG, the degree of VPx was highest during TEP. The gold standard for validation was effective ablation of the AP. Results: The MCG classification of VPx was accurate in 94% of AP, versus 64% and 67% with ECG, during sinus rhythm and during pacing‐induced maximal VPx, respectively. In 4.5% of cases with unclear ECG localization, MCG suggested a complex septal VPx. In all patients with successful ablations, the 3D MCG localization of the AP corresponded to the ablation site. Conclusions: MCG was more accurate than ECG for the classification of VPx and provided additional information in the non‐invasive EP assessment of patients with WPW syndrome.