DBDonatella Brisinda

Donatella Brisinda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Donatella Brisinda has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-linear Analysis of Heart Rate Variability Improves Differential Diagnosis between Parkinson Disease and Multiple System Atrophy

    by Donatella Brisinda, Francesco Fioravanti, Emilia Iantorno, Anna Sorbo, Angela Venuti, Claudia Cataldi, Kristian Efremov, Riccardo Fenici

    Autonomic nervous system; Parkinson disease; multiple system atrophy; non linear HRV analysis; discriminant analysis.

  • Cardiovascular autonomic nervous system evaluation in Parkinson disease and multiple system atrophy

    by Donatella Brisinda, Anna Rita Sorbo, Raffaella Di Giacopo, Angela Venuti, Anna Rita Bentivoglio, Riccardo Fenici


    • 1 July 2007
      • p. 23-8

    Magnetocardiography provides non-invasive three-dimensional electroanatomical imaging of cardiac electrophysiology.

    by Riccardo Fenici, Donatella Brisinda

    More than two decades of research work have shown that magnetocardiographic mapping (MCG) is reliable for non-invasive three-dimensional electroanatomical imaging (3D-EAI) of arrhythmogenic substrates. Magnetocardiographic mapping is now become appealing to interventional electrophysiologists after recent evidence that MCG-based dynamic imaging of atrial arrhythmias could be useful to classify patients with atrial fibrillation (AF) before ablation and to plan the most appropriate therapeutic approach. This article will review some key-points of 3D-EAI and discuss what is still missing to favor clinical applicability of MCG-based 3D-EAI. Magnetocardiographic mapping is performed with a 36-channel unshielded mapping system, based on DC-SQUID sensors coupled to second-order axial gradiometers (pick-up coil 19 mm and 55-70 mm baselines; sensitivity of 20 fT/Sqrt[Hz] in above 1 Hz), as part of the electrophysiologic investigation protocol, tailored to the diagnostic need of each arrhythmic patient. More than 500 arrhythmic patients have been investigated so far. The MCG-based 3D-EAI has proven useful to localize well-confined arrhythmogenic substrates, such as focal ventricular tachycardia or preexcitation, to understand some causes for ablation failure, to study atrial electrophysiology including spectral analysis and localization of dominant frequency components of AF. However, MCG is still missing software tools for automatic and/or interactive 3D imaging, and multimodal data fusion equivalent to those provided with systems for invasive 3D electroanatomical mapping. Since there is an increasing trend to favor interventional treatment of arrhythmias, clinical application of MCG 3D-EAI is foreseen to improve preoperative selection of patients, to plan the appropriate interventional approach and to reduce ablation failure.


    • 17 April 2004
      • Vol. 51  (56) , 570-4

    Radiofrequency ablation of hepatic tissue: a new experimental animal model.

    by Enrico Maria Zardi, Antonio Picardi, Domenico Borzomati, Roberto Coppola, Marco Caricato, Tommaso Galeotti, Sergio Valeri, Antonella Bianchi, Donatella Brisinda, Antonella Afeltra, et al.

    Experimental radiofrequency ablation has already been performed in healthy livers of porcine models, but not in less expensive and easy-to-manage rats, with devices capable of delivering radiofrequency ablation in the 20-30 g liver of such small animals being so far unavailable. We experimented with a modified system of radiofrequency ablation of liver tissue in rat models developing a custom-made needle-microelectrode of very small dimensions (0.3x2 mm) and an electrode-tip cooling technique, based on saline solution infusion. We adjusted duration (seconds) and power (watts) of radiofrequency ablation letting them range between 5-50 seconds and 5-25 W, respectively, to obtain the greatest lesions with the least side effects. After sacrificing the animals, an accurate histological examination of the liver was made. It is possible to establish beforehand the diameter of thermal liver lesion on the basis of joules of applied energy. The greatest increase of liver thermal lesion diameter (8 mm) is obtained with a 250-joule (10 W for 25 seconds) thermal energy cooling the electrode-tissue interface. Experimental radiofrequency ablation in rat liver is an effective and cheap way to study its effects on healthy hepatic tissues. It might be the first step to treat experimentally caused liver tumors.


  • Safety of botulinum neurotoxin treatment in patients with chronic anal fissure.

    by Donatella Brisinda, Giorgio Maria, Riccardo Fenici, Ignazio Massimo Civello, Giuseppe Brisinda


    • 1 March 2002
      • Vol. 3  (3) , 151-65

    Magnetocardiography: current status and perspectives. Part II: Clinical applications.

    by Isabella Tavarozzi, Silvia Comani, Cosimo Del Gratta, Silvano Di Luzio, Gian Luca Romani, Sabina Gallina, Marco Zimarino, Donatella Brisinda, Riccardo Fenici, Raffaele De Caterina

    Magnetocardiography (MCG) is a non-invasive and risk-free technique allowing body surface recording of the magnetic fields generated by the electrical activity of the heart. The MCG recording system allows spatially and temporally accurate measurements of the very weak magnetic fields produced by currents flowing within myocardial fibers during cardiac activity. MCG has now been around for over 30 years, but only recently has progress in instrumentation put the technique on the verge of clinical applicability. This review summarizes the physical principles, instrumentation, main clinical applications and perspectives for the clinical use of MCG. This second part is devoted to the description of the main current clinical applications and perspectives.


    • 1 February 2002
      • Vol. 3  (2) , 75-85

    Magnetocardiography: current status and perspectives. Part I: Physical principles and instrumentation.

    by Isabella Tavarozzi, Silvia Comani, Cosimo Del Gratta, Gian Luca Romani, Silvano Di Luzio, Donatella Brisinda, Sabina Gallina, Marco Zimarino, Riccardo Fenici, Raffaele De Caterina

    Magnetocardiography (MCG) is a non-invasive and risk-free technique allowing body surface recording of the magnetic fields generated by the electrical activity of the heart. The MCG recording system allows spatially and temporally accurate measurements of the very weak magnetic fields produced by currents flowing within myocardial fibers during cardiac activity. MCG has now been around for over 30 years, but only recently has progress in instrumentation put the technique on the verge of clinical applicability. This review summarizes the physical principles, instrumentation, main clinical applications and perspectives for the clinical use of MCG. This first part is devoted to the description of the physical principles and instrumentation.