Abdelhamid H. Elgazzar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Abdelhamid H. Elgazzar has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Ismet Sarikaya
Kuwait University
3 shared publicationsSaud Alenezi
Department of Nuclear Medicine, Faculty of Medicine, Kuwait University, Safat, Kuwait
3 shared publicationsB David Collier
2 shared publicationsDia Shehab
Kuwait University
2 shared publicationsMousa Khadada
Kuwait University
2 shared publicationsNafisa Kazem
Mubarak Hospital
2 shared publications
Latest Publications
- 29 May 2018
- Published by Springer Nature
- p. 41-60
Pulmonary System
- Open Access
- 1 October 2017
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 16 (04) , 255-256
Loss of a pioneer: Hussein Abdel-Dayem, MD 1934-2017
- 1 October 2017
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 16 (04) , 255-256
Open AccessLoss of a pioneer: Hussein Abdel-Dayem, MD 1934-2017
- Open Access
- 8 August 2017
- Published by S. Karger AG in Medical Principles and Practice
- Vol. 26 (5) , 415-420
Scintigraphic Patterns of Indium-111 Oxine-Labeled White Blood Cell Imaging of Gram-Negative versus Gram-Positive Vertebral Osteomyelitis
Objective: The goal of the study was to investigate whether or not gram-negative organisms that secrete antichemotactic factors cause the nonaccumulation pattern of 111In-oxine-labeled white blood cell (111In-WBC) scans. Materials and Methods:Staphylococcus aureus (gram-positive) (group 1) was injected into 25 rabbits and Escherichia coli (gram-negative) (group 2) into another 25 to induce infection in the lumbar vertebrae or left thigh bone (femur). Sixteen successfully infected and surviving rabbits from each group were used for imaging and analysis. Of the 16 rabbits, each group included 8 with vertebral infection and 8 with femur infection. For imaging, each rabbit was injected intravenously with 11.1 MBq (300 μCi) 111In-WBC, and images were acquired 24 h later. Microscopic histopathology was performed after decalcification to confirm osteomyelitis. Results: The 111In-WBC accumulation was observed in 7 (87.5%) of the 8 rabbits infected with S. aureus in the vertebrae and thigh bone. Of the rabbits infected with the gram-negative vertebrae, 1 (12.5%) showed little accumulation of 111In-WBC. Of the 8 rabbits with gram-negative-infected femurs, 1 had high accumulation and another had low accumulation of 111In-WBC, while the rest did not show any uptake. Osteomyelitis was confirmed by histopathology in all the successfully infected rabbits used for imaging. Conclusion: In the majority of the gram-positive-infected rabbit vertebrae there was high accumulation of 111In-WBC. However, no accumulation of 111In-WBC was observed in most of the vertebrae infected with gram-negative organisms, which release antichemotactic factors that prevent adequate accumulation of WBC at the infected area.
- 8 August 2017
- Published by S. Karger AG in Medical Principles and Practice
- Vol. 26 (5) , 415-420
Open AccessScintigraphic Patterns of Indium-111 Oxine-Labeled White Blood Cell Imaging of Gram-Negative versus Gram-Positive Vertebral Osteomyelitis
Objective: The goal of the study was to investigate whether or not gram-negative organisms that secrete antichemotactic factors cause the nonaccumulation pattern of 111In-oxine-labeled white blood cell (111In-WBC) scans. Materials and Methods:Staphylococcus aureus (gram-positive) (group 1) was injected into 25 rabbits and Escherichia coli (gram-negative) (group 2) into another 25 to induce infection in the lumbar vertebrae or left thigh bone (femur). Sixteen successfully infected and surviving rabbits from each group were used for imaging and analysis. Of the 16 rabbits, each group included 8 with vertebral infection and 8 with femur infection. For imaging, each rabbit was injected intravenously with 11.1 MBq (300 μCi) 111In-WBC, and images were acquired 24 h later. Microscopic histopathology was performed after decalcification to confirm osteomyelitis. Results: The 111In-WBC accumulation was observed in 7 (87.5%) of the 8 rabbits infected with S. aureus in the vertebrae and thigh bone. Of the rabbits infected with the gram-negative vertebrae, 1 (12.5%) showed little accumulation of 111In-WBC. Of the 8 rabbits with gram-negative-infected femurs, 1 had high accumulation and another had low accumulation of 111In-WBC, while the rest did not show any uptake. Osteomyelitis was confirmed by histopathology in all the successfully infected rabbits used for imaging. Conclusion: In the majority of the gram-positive-infected rabbit vertebrae there was high accumulation of 111In-WBC. However, no accumulation of 111In-WBC was observed in most of the vertebrae infected with gram-negative organisms, which release antichemotactic factors that prevent adequate accumulation of WBC at the infected area.
- Open Access
- 19 May 2017
- Published by Saudi Heart Association in Journal of the Saudi Heart Association
- Vol. 30 (1) , 3-8
Myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients
The prevalence of coronary artery disease (CAD) is high in patients with diabetes. Because ischemia and infarction are often silent in diabetic patients, diagnosis of CAD occurs inevitably late. It is essential to identify the presence of CAD in diabetic patients to start early treatment. Therefore, the aim of this study was to determine the prevalence of abnormal myocardial perfusion in asymptomatic type 2 diabetic patients using myocardial perfusion imaging. Fifty-nine patients with type 2 diabetes, who did not have any history of CAD, but did have risk factors underwent myocardial perfusion single-photon emission computed tomography (SPECT) imaging using 99mTc-tetrofosmin and a 2-day stress–rest protocol. Two nuclear medicine specialists independently interpreted the images. Statistical analysis was performed to determine if there is a correlation between the presence of perfusion abnormalities and the history of diabetes (duration of disease, type of treatment, level of control, and presence and type of complications). The influence of other factors such as age, sex, smoking history, and family history of CAD, with abnormal scans were also studied. Of the 59 patients, abnormal scans were detected in 22 (37%) including 16 with reversible defects due to stress-induced ischemia. Hence the prevalence was 37%. Duration of diabetes, use of insulin, nephropathy, and neuropathy were significantly associated with abnormal scans (p = 0.048, p = 0.045, p = 0.006, and p = 0.03, respectively). Additionally, positive family history of CAD was highly associated with perfusion abnormalities (p < 0.001). No significant association was found between other risk factors, such as hyperlipidemia and the presence of perfusion defects. We found a high prevalence of myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients. Perfusion abnormalities on myocardial perfusion SPECT images were associated with disease duration, insulin use, nephropathy, and neuropathy. Asymptomatic diabetic patients might be candidates with CAD abnormalities that can be studied using myocardial perfusion SPECT.
- 19 May 2017
- Published by Saudi Heart Association in Journal of the Saudi Heart Association
- Vol. 30 (1) , 3-8
Open AccessMyocardial perfusion abnormalities in asymptomatic type 2 diabetic patients
The prevalence of coronary artery disease (CAD) is high in patients with diabetes. Because ischemia and infarction are often silent in diabetic patients, diagnosis of CAD occurs inevitably late. It is essential to identify the presence of CAD in diabetic patients to start early treatment. Therefore, the aim of this study was to determine the prevalence of abnormal myocardial perfusion in asymptomatic type 2 diabetic patients using myocardial perfusion imaging. Fifty-nine patients with type 2 diabetes, who did not have any history of CAD, but did have risk factors underwent myocardial perfusion single-photon emission computed tomography (SPECT) imaging using 99mTc-tetrofosmin and a 2-day stress–rest protocol. Two nuclear medicine specialists independently interpreted the images. Statistical analysis was performed to determine if there is a correlation between the presence of perfusion abnormalities and the history of diabetes (duration of disease, type of treatment, level of control, and presence and type of complications). The influence of other factors such as age, sex, smoking history, and family history of CAD, with abnormal scans were also studied. Of the 59 patients, abnormal scans were detected in 22 (37%) including 16 with reversible defects due to stress-induced ischemia. Hence the prevalence was 37%. Duration of diabetes, use of insulin, nephropathy, and neuropathy were significantly associated with abnormal scans (p = 0.048, p = 0.045, p = 0.006, and p = 0.03, respectively). Additionally, positive family history of CAD was highly associated with perfusion abnormalities (p < 0.001). No significant association was found between other risk factors, such as hyperlipidemia and the presence of perfusion defects. We found a high prevalence of myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients. Perfusion abnormalities on myocardial perfusion SPECT images were associated with disease duration, insulin use, nephropathy, and neuropathy. Asymptomatic diabetic patients might be candidates with CAD abnormalities that can be studied using myocardial perfusion SPECT.
- Open Access
- 1 April 2017
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 16 (02) , 145-149
Ultrastructure of hyperfunctioning parathyroid glands: Does it explain various patterns of 99mTc-sestamibi uptake
The aim of this study was to correlate the uptake of 99mTc-methoxy-isobutyl-isonitrile (MIBI) with ultra-structural features of parathyroid adenomas. Twenty patients with proven primary hyperparathyroidism were evaluated prospectively. Preoperative double-phase 99mTc-MIBI scintigraphy was performed in all patients and the degree of tracer uptake by the parathyroid lesions was assessed visually and semi-quantitatively. The excised glands were examined histologically and ultrastructurally, and their features were correlated with the degree of the radiotracer uptake. At surgery, 21 parathyroid adenomas were removed (double adenoma in one patient and a solitary adenoma in each of the remaining 19 patients). 99mTc-MIBI scan detected 18 of the 21 adenomas. There was positive correlation between the degree of 99mTc-MIBI uptake and the mitochondrial contents of the parathyroid adenoma cells. Four adenomas with intense uptake had high content of mitochondria in the cells. The three false-negative scans had low-to-moderate mitochondrial content. 99mTc-MIBI uptake is related to the mitochondrial content of the parathyroid adenoma cells.
- 1 April 2017
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 16 (02) , 145-149
Open AccessUltrastructure of hyperfunctioning parathyroid glands: Does it explain various patterns of 99mTc-sestamibi uptake
The aim of this study was to correlate the uptake of 99mTc-methoxy-isobutyl-isonitrile (MIBI) with ultra-structural features of parathyroid adenomas. Twenty patients with proven primary hyperparathyroidism were evaluated prospectively. Preoperative double-phase 99mTc-MIBI scintigraphy was performed in all patients and the degree of tracer uptake by the parathyroid lesions was assessed visually and semi-quantitatively. The excised glands were examined histologically and ultrastructurally, and their features were correlated with the degree of the radiotracer uptake. At surgery, 21 parathyroid adenomas were removed (double adenoma in one patient and a solitary adenoma in each of the remaining 19 patients). 99mTc-MIBI scan detected 18 of the 21 adenomas. There was positive correlation between the degree of 99mTc-MIBI uptake and the mitochondrial contents of the parathyroid adenoma cells. Four adenomas with intense uptake had high content of mitochondria in the cells. The three false-negative scans had low-to-moderate mitochondrial content. 99mTc-MIBI uptake is related to the mitochondrial content of the parathyroid adenoma cells.
- 1 July 2016
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 46 (4) , 359-367
Structure and Activities of Nuclear Medicine in Kuwait
- 1 July 2016
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 46 (4) , 359-367
Structure and Activities of Nuclear Medicine in Kuwait
- Open Access
- 1 June 2015
- Published by Taylor & Francis in Research and Reports in Nuclear Medicine
- Vol. ume 5, 9-18
Scintigraphic parathyroid imaging: concepts and new developments
Hyperparathyroidism is a condition caused by increased secretion of the parathyroid hormone, which plays an important role in calcium homeostasis. This condition has been diagnosed more frequently recently and can affect multiple organ systems resulting in a variety of signs and symptoms. Hyperparathyroidism can be classified as primary, secondary, or tertiary disease and can result from eutopic or ectopic parathyroid lesions. Parathyroid adenoma is the most common cause of primary hyperparathyroidism, accounting for more than 80% of cases. Parathyroid hyperplasia is the cause in about 20% of patients, while parathyroid carcinoma is rare and accounts for less than 1% of cases. Surgical removal of the abnormal gland(s) is the definite treatment for hyperparathyroidism. Bilateral neck exploration is the classical approach for parathyroidectomy. In recent years, minimally invasive parathyroidectomy is becoming more popular due to the fewer complications and shorter hospital stay. This new approach has placed a greater emphasis on the preoperative localization techniques. Multiple localization techniques have been used, including invasive techniques, anatomical, and scintigraphic imaging modalities. Thallium/pertechnetate subtraction method was introduced in 1980 and was the first method to gain widespread acceptance. It is not widely used now due to the suboptimal characteristics of thallium and the technical difficulties associated with subtraction and registration. The dual-phase method using Tc-99m sestamibi is currently the method of choice for parathyroid localization. It is based on the differential washout rate of sestamibi from the thyroid and abnormal parathyroid glands. The reported sensitivity of this method ranges from 80% to 90%. The addition of single-photon emission computed tomography (SPECT) and more recently SPECT/CT improves the anatomical localization and helps in the differentiation of the parathyroid from the thyroid lesions. Multiple factors can affect the sensitivity of the scan including the lesion size, cellularity, and the presence of P-glycoprotein. Modification of the imaging protocol may help to avoid false positive or false negative results in certain cases. Positron emission tomography has been recently investigated for possible role in parathyroid imaging and showed promising results with 11C-methionine.
- 1 June 2015
- Published by Taylor & Francis in Research and Reports in Nuclear Medicine
- Vol. ume 5, 9-18
Open AccessScintigraphic parathyroid imaging: concepts and new developments
Hyperparathyroidism is a condition caused by increased secretion of the parathyroid hormone, which plays an important role in calcium homeostasis. This condition has been diagnosed more frequently recently and can affect multiple organ systems resulting in a variety of signs and symptoms. Hyperparathyroidism can be classified as primary, secondary, or tertiary disease and can result from eutopic or ectopic parathyroid lesions. Parathyroid adenoma is the most common cause of primary hyperparathyroidism, accounting for more than 80% of cases. Parathyroid hyperplasia is the cause in about 20% of patients, while parathyroid carcinoma is rare and accounts for less than 1% of cases. Surgical removal of the abnormal gland(s) is the definite treatment for hyperparathyroidism. Bilateral neck exploration is the classical approach for parathyroidectomy. In recent years, minimally invasive parathyroidectomy is becoming more popular due to the fewer complications and shorter hospital stay. This new approach has placed a greater emphasis on the preoperative localization techniques. Multiple localization techniques have been used, including invasive techniques, anatomical, and scintigraphic imaging modalities. Thallium/pertechnetate subtraction method was introduced in 1980 and was the first method to gain widespread acceptance. It is not widely used now due to the suboptimal characteristics of thallium and the technical difficulties associated with subtraction and registration. The dual-phase method using Tc-99m sestamibi is currently the method of choice for parathyroid localization. It is based on the differential washout rate of sestamibi from the thyroid and abnormal parathyroid glands. The reported sensitivity of this method ranges from 80% to 90%. The addition of single-photon emission computed tomography (SPECT) and more recently SPECT/CT improves the anatomical localization and helps in the differentiation of the parathyroid from the thyroid lesions. Multiple factors can affect the sensitivity of the scan including the lesion size, cellularity, and the presence of P-glycoprotein. Modification of the imaging protocol may help to avoid false positive or false negative results in certain cases. Positron emission tomography has been recently investigated for possible role in parathyroid imaging and showed promising results with 11C-methionine.
- Open Access
- 1 April 2015
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 14 (02) , 125-127
Value of Oblique View in Nodular Thyroid Disease; Revisiting Fundamentals
Thyroid scintigraphy plays an important role in the anatomical and functional evaluation of thyroid nodules which carry the risk of malignancy. The presence of multiple nodules carries overall smaller risk of cancer than solitary nodule. Missing nodules, whether solitary or multiple, may mean delaying detection of possible cancer. Therefore, it is important to improve the delectability of thyroid scintigraphy using most optimal imaging techniques. For pinhole thyroid imaging, there is a recent trend to omit oblique projections by some laboratories. The objective of this study was to reevaluate the impact of oblique projections in the detection of thyroid nodules. A total of 92 cases with nodular thyroid disease on routine pinhole thyroid scintigraphy was reviewed retrospectively. Two nuclear medicine physicians recorded the number of nodules based on the anterior view only and another time with adding the oblique views. A total of 192 nodules was detected using the three views. Sixty nodules (31%) were only seen on the oblique views and were missed on the anterior projections. Oblique pinhole projections are mandatory for adequate thyroid scintigraphy since 31% of nodules are missed if only anterior projection was used for interpretation. Following proper techniques will avoid missing of detection of nodule that may harbor cancer.
- 1 April 2015
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 14 (02) , 125-127
Open AccessValue of Oblique View in Nodular Thyroid Disease; Revisiting Fundamentals
Thyroid scintigraphy plays an important role in the anatomical and functional evaluation of thyroid nodules which carry the risk of malignancy. The presence of multiple nodules carries overall smaller risk of cancer than solitary nodule. Missing nodules, whether solitary or multiple, may mean delaying detection of possible cancer. Therefore, it is important to improve the delectability of thyroid scintigraphy using most optimal imaging techniques. For pinhole thyroid imaging, there is a recent trend to omit oblique projections by some laboratories. The objective of this study was to reevaluate the impact of oblique projections in the detection of thyroid nodules. A total of 92 cases with nodular thyroid disease on routine pinhole thyroid scintigraphy was reviewed retrospectively. Two nuclear medicine physicians recorded the number of nodules based on the anterior view only and another time with adding the oblique views. A total of 192 nodules was detected using the three views. Sixty nodules (31%) were only seen on the oblique views and were missed on the anterior projections. Oblique pinhole projections are mandatory for adequate thyroid scintigraphy since 31% of nodules are missed if only anterior projection was used for interpretation. Following proper techniques will avoid missing of detection of nodule that may harbor cancer.
- 27 June 2014
- Published by Springer Nature
- p. 305-318
Adrenal Gland