  • Diagnostic tools for atrial tachyarrhythmias in implantable pacemakers: a review of technical options and pitfalls

    by W. G. de Voogt, N. M. van Hemel

    Background. Correct pacemaker (PM) diagnosis of paroxysmal atrial tachyarrhythmias is crucial for their prevention and intervention with specific atrial pacing programmes. The PM mode switch to only ventricular pacing after detection of atrial tachyarrhythmias is often used as the parameter to quantify the ‘burden’ of atrial tachyarrhythmias. Objectives. This review addresses potential errors in the detection and diagnosis of atrial tachyarrhythmias, sometimes resulting in incorrect mode switches. The interpretation of PM-stored data of patients with atrial tachyarrhythmias and the results of trials of pace prevention and intervention can be better appreciated with more insight into the technical options and pitfalls. Results. Literature and clinical experience demonstrate that the correctness of PM-derived diagnosis of atrial tachyarrhythmias depends on 1) the sensitivity setting to detect the onset and perpetuation of atrial tachyarrhythmias frequently characterised by variable and low-voltage signals, 2) the rejection of far-field R wave sensing by the atrial sense amplifier, 3) the facility for verification of mode switches by a high-quality intracardiac registration of the nonmodified atrial electrogram. The configuration of the atrial lead also contributes to the diagnostic performance of the PM. Conclusion. Not only pacing algorithms and diverse technical PM features but also the atrial lead configuration are currently the limiting factors to the fully reliable, automated detection and diagnosis of atrial tachyarrhythmias. If these technical shortcomings can be improved, better signal processing will result. Then atrial pacing to prevent or suppress atrial tachyarrhythmias will be more justified. (Neth Heart J 2008;16:201-10.)


  • Open Access

    Clinical application of pacemakers in atrial tachyarrhythmias

    by W. G. de Voogt, N. M. van Hemel


  • Open Access

    No evidence of automatic atrial overdrive pacing efficacy on reduction of paroxysmal atrial fibrillation

    by Willem de Voogt, Norbert van Hemel, Philip de Vusser, Georges H. Mairesse, Rob van Mechelen, Juhani Koistinen, Arjan van Den Bos, Indrek Roose, JÜRi Voitk, Sinikka Yli-MÄYry, et al.

    Aims Paroxysmal atrial fibrillation (PAF) is frequently encountered in pacemaker patients, most commonly in sick sinus syndrome. The combination of site-specific pacing in conjunction with an overdrive algorithm combined with antiarrhythmic drugs on the incidence of PAF in patients with a conventional indication for pacing is unknown. Methods and results Patients with pacemaker indication and PAF received a DDDR-pacemaker, which included an automatic atrial overdrive (AO) algorithm. The atrial lead was implanted in either the right atrial appendage (RAA) ( n = 83) or the right low-atrial septum (LAS) ( n = 94). The algorithm was switched on or off in a 3 month, single blind crossover design and antiarrhythmic drugs were kept stable. A control group of 96 patients (LAS, n = 14; RAA, n = 84) without PAF served as controls to assess any proarrhythmic effect of overdrive pacing. Atrial fibrillation (AF) burden defined as cumulative time in mode switch was not reduced during automatic AO from either the RAA or from the LAS. The reduction was not effective both for AF of short (Conclusions We could not demonstrate a reduction of AF burden defined as cumulative time in AF by the AO algorithm, in patients who are paced for standard indications and PAF, neither from the RAA nor from the LAS.


  • Open Access

    Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording

    by Willem G. de Voogt, Norbert M. van Hemel, Arjan A. van de Bos, Juhani Koïstinen, Jules H. Fast

    Aims Verification of the accuracy of onset, offset, and duration of automatic mode switching (AMS) of pacemakers compared with onset and end of atrial fibrillation (AF) or atrial tachycardia (AT). Correct pacemaker diagnosis of atrial tachyarrhythmias (AA) is indispensable for reliable automatic prevention and intervention algorithms of AA. Methods and results Comparison was made of the AMS registration of the pacemaker-stored electrograms (EGMs) and the number and cumulative duration of these episodes with continuous 7-day Holter monitoring. Atrial sensitivity was kept at 0.5 mV and far field R-wave recognition in the atrial channel was excluded by blanking of this signal. Lead types were confined to leads with short-ring tip spacing (10–13.8 mm). During Holter monitoring, 18 of 57 included patients with standard reason for pacemaker implantation showed episodes of AF or AT. Cumulative duration of AF and AT from Holter was correctly interpreted by the pacemaker in 99.9% of the patients. All episodes of AF, as seen on the Holter recording, were recognized by the pacemaker (correlation 99.9%). During AF, multiple episodes of undersensing were detected. The number of AMS episodes was influenced by undersensing during AF. The influence of these short episodes of undersensing on the total duration of AF was trivial (cumulative duration of AF was 99.9% correct). In patients with AT without AF on Holter (n=7) and in contrast to the AF episodes, the cumulative AT duration did not correlate well (63%) with the Holter recordings. The number of AMS episodes in the setting of AT was influenced by the atrial tachycardia detection rate setting and the duration of the post-ventricular atrial blanking interval. Conclusion The total duration of AF is correctly represented by the total duration of AMS and can be considered a reliable measure of total AF duration. AT duration was poorly correlated with AMS duration. The number of mode switches does not reflect the number of episodes of AF/AT. Increased memory capacity allowing the storing of all EGMs triggered by the initiation of AF/AT would be the ideal setting with which to optimize the diagnostic performance of pacemakers.


  • Open Access

    Occlusion of the coronary sinus: a complication of resynchronisation therapy for severe heart failure

    by Willem G. de Voogt, Jaap H. Ruiter

    The finding of complete obstruction of the proximal coronary sinus after left ventricular (LV) lead extraction during LV lead replacement is uncommon. In our case, we used a large collateral branch of the middle cardiac vein as an alternative route to the postero-lateral region. We have termed this the ‘collateral approach’.


  • Far‐Field R‐Wave Reduction with a Novel Lead Design: Experimental and Human Results

    by Willem DE Voogt, Norbert VAN Hemel, Albert Willems, Jaap Visser, Yougandh Chitre, Gene Bornzin, John Helland

    Introduction: The purpose of this study was to examine a bipolar screw‐in lead (NL), specially designed to reduce unwanted far‐field R‐wave (FFRW) signal detection in an acute human setting. The results were compared with animal experiments. Methods: The newly designed lead with a center‐to‐center distance between the anode and cathode electrodes of 3.23 mm, corresponding to an inter‐electrode spacing of 1.1 mm was implanted in nine canines with a follow‐up of 6 months. Sensing of P waves, FFRW signals, pacing threshold, and impedance was measured at regular intervals. As a result of the positive outcome with the animal study, an acute human experiment was performed. In patients scheduled for conventional dual chamber pacemaker implantation, the NL was compared to a Tendril® Model 1388T bipolar screw‐in lead (St. Jude Medical, CRMD, Sylmar, CA). Results: Utilizing a tip‐to‐ring distance of 1.1 mm, the optimum P wave to FFRW ratio was found in animal experiments. In the acute human tests in 15 patients, the mean P‐wave voltage of the 1388T lead of 3.30 ± 1.54 mV was slightly larger than that of the NL, at 2.55 ± 1.11 mV, but did not differ significantly (P = 0.13). The FFRW voltage of the 1388T lead was 0.62 ± 0.37 mV and was significantly greater from that of the NL, at 0.10 ± 0.08 mV (P < 0.0001). Pacing thresholds and pacing impedances were comparable. Conclusion: Animal testing results were reproducible in the acute human test setting. The lead reduced the paced FFRW signal amplitudes significantly, allowing for high atrial sensitivity settings but without sensing the FFRW. A robust P‐wave signal could be retained.


  • A Technique of Lead Insertion for Low Atrial Septal Pacing

    by DE Voogt, Willem G., Rob VAN Mechelen, Arjan VAN Den Bos, Mike Scheffer, VAN Hemel, Norbert M., Juhani Koistinen

    Background: Pacing in the low right atrial septum (LAS) appears superior to right atrial appendage or free wall stimulation for the prevention of paroxysmal atrial fibrillation. However, insertion of active fixation lead in the low right atrial septal position is difficult and time consuming, inhibiting application of this pacing method in daily practice. Methods: The technique of handling and positioning of a new “over the wire” lead system is presented with emphasis on electrocardiographic P wave pattern and fluoroscopic landmarks. Results: The initial results demonstrate an acute implantation and short‐term success of LAS pacing of >90% in the first 100 patients without major complications. Pacing thresholds at 3 and 6 months were fully comparable with that of the conventional atrial pacing, whereas impedance and atrial sensing signals were significantly higher at 3 and 6 months follow‐up. Conclusion: These favorable initial results justify recommanding chronic LAS pacing with the active fixation atrial lead and providinge guidelines and fluoroscopic landmarks for the implantation. Insertion of the atrial active fixation lead positioned with the Locator™ tool strongly supports the implantation procedure.


  • Electrocardiographic characteristics in low atrial septum pacing

    by Willem G. de Voogt, Rob van Mechelen, Mike Scheffer, Addy J.M. van Miltenburg van Zijl, Abdou A. Elhendy


  • Open Access

    Electrical characteristics of low atrial septum pacing compared with right atrial appendage pacing

    by Willem G de Voogt, Rob van Mechelen, Arjan A van Den Bos, Mike Scheffer, Norbert M van Hemel, Paul A Levine

    Aim. The study was designed to compare the electrical characteristics of atrial leads placed in the low atrial septum (LAS) with those placed in the ri


  • Open Access

    Understanding capture detection

    by W Devoogt, Ben F. M. Vonk, Bert A. Albers, Florian Hintringer

    Automatic capture detection systems are currently available in several cardiac pacing devices. All current systems use low-polarization electrodes and no beat to beat detection system is available for all types of electrodes. In addition the success ratio for currently available systems is not always 100%. Failure to detect capture reliably is often related to the behaviour of the electrode–tissue interface under different circumstances. Pacemaker electrodes can be considered electrochemical cells with complicated characteristics depending on time, temperature and electrical charge. This electrochemical cell is disturbed when a charge is transferred across the electrode–tissue interface during pacing. Several measures can be taken in order to minimise this disturbance or pace polarization artefact (PPA) including the use of high active surface area electrodes and application of tri-phasic pacing pulses. Another factor influencing detection of evoked potentials is the input circuit of the pacemaker affecting the PPA and the evoked response. Positive PPAs can be falsely interpreted as evoked potentials due to the undershoot of the second order filters applied in modern cardiac pacemakers. This paper explains the behaviour of the interface between the electrode and the cardiac tissue in combination with the pacemaker output circuits and input amplifiers under different circumstances.