Jiang Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiang Du has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Charles A. Mistretta
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin
4 shared publications- Sean B. Fain
Department of Radiology, University of Iowa, Iowa City, Iowa
4 shared publications C.A. Mistretta
Department of Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
3 shared publicationsF.R. Korosec
Department of Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
3 shared publicationsT.M. Grist
Department of Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
3 shared publicationsThomas M. Grist
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin
3 shared publications
Latest Publications
- Open Access
- 18 February 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (3) , 730-734
Time-resolved undersampled projection reconstruction magnetic resonance imaging of the peripheral vessels using multi-echo acquisition
- 18 February 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (3) , 730-734
Open AccessTime-resolved undersampled projection reconstruction magnetic resonance imaging of the peripheral vessels using multi-echo acquisition
- Open Access
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1093-1102
Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1093-1102
Open AccessFloating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion
- 22 October 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 20 (5) , 894-900
Contrast‐enhanced peripheral magnetic resonance angiography using time‐resolved vastly undersampled isotropic projection reconstruction
To investigate the application of time‐resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast‐enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run‐off vasculature in the abdomen, thigh, and calf (three stations). Time‐resolved distal extremity imaging was performed using VIPR sequence through the comparison of two acquisition matrix sizes: 256 with TR/TE = 3.7/1.4 msec and 320 with TR/TE = 4.5/1.8 msec under the same scan time of two minutes. VIPR acquisition was combined with a bolus‐chase technique to image the peripheral run‐off vasculature. The time‐resolved images were reconstructed using a revised sliding window reconstruction filter whose temporal aperture remained narrow for low spatial frequencies and increased quadratically to include all the projection data for high spatial frequencies. The new temporal filter significantly suppressed the undersampling streak artifacts and venous contamination, while maintaining a high temporal resolution. Both high spatial resolution (ranging from 1.56 × 1.56 × 1.56 mm to 1.25 × 1.25 × 1.25 mm) and high temporal resolution (three seconds per frame) distal extremity images and peripheral run‐off images were generated using time‐resolved VIPR acquisition, which provides isotropic spatial resolution and isotropic coverage. Time‐resolved VIPR acquisition was demonstrated to be well suited for distal extremity imaging by providing isotropic spatial resolution, isotropic coverage, and high temporal resolution. The combination of time‐resolved VIPR and bolus chase technique provided a novel approach for peripheral run‐off examinations. J. Magn. Reson. Imaging 2004;20:894–900.
- 22 October 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 20 (5) , 894-900
Contrast‐enhanced peripheral magnetic resonance angiography using time‐resolved vastly undersampled isotropic projection reconstruction
To investigate the application of time‐resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast‐enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run‐off vasculature in the abdomen, thigh, and calf (three stations). Time‐resolved distal extremity imaging was performed using VIPR sequence through the comparison of two acquisition matrix sizes: 256 with TR/TE = 3.7/1.4 msec and 320 with TR/TE = 4.5/1.8 msec under the same scan time of two minutes. VIPR acquisition was combined with a bolus‐chase technique to image the peripheral run‐off vasculature. The time‐resolved images were reconstructed using a revised sliding window reconstruction filter whose temporal aperture remained narrow for low spatial frequencies and increased quadratically to include all the projection data for high spatial frequencies. The new temporal filter significantly suppressed the undersampling streak artifacts and venous contamination, while maintaining a high temporal resolution. Both high spatial resolution (ranging from 1.56 × 1.56 × 1.56 mm to 1.25 × 1.25 × 1.25 mm) and high temporal resolution (three seconds per frame) distal extremity images and peripheral run‐off images were generated using time‐resolved VIPR acquisition, which provides isotropic spatial resolution and isotropic coverage. Time‐resolved VIPR acquisition was demonstrated to be well suited for distal extremity imaging by providing isotropic spatial resolution, isotropic coverage, and high temporal resolution. The combination of time‐resolved VIPR and bolus chase technique provided a novel approach for peripheral run‐off examinations. J. Magn. Reson. Imaging 2004;20:894–900.
- Open Access
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 204-208
High‐resolution multistation peripheral MR angiography using undersampled projection reconstruction imaging
A novel protocol for three‐station MR angiography (MRA) of the lower extremities is described. A time‐resolved undersampled projection reconstruction (PR) acquisition was used to image the calf station during a first injection, and non‐time‐resolved PR acquisitions were used with the bolus‐chase technique to image the abdomen and thigh stations during a second injection. The streak artifacts resulting from undersampling the PR data were reduced with the use of a spatial Fermi filter based on the sensitivity of each coil element in a peripheral vascular phased‐array coil. This novel technique provided high spatial resolution and a broad range of coverage, and depicted the contrast dynamics in the most distal station of the lower extremities. Magn Reson Med 52:204–208, 2004.
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 204-208
Open AccessHigh‐resolution multistation peripheral MR angiography using undersampled projection reconstruction imaging
A novel protocol for three‐station MR angiography (MRA) of the lower extremities is described. A time‐resolved undersampled projection reconstruction (PR) acquisition was used to image the calf station during a first injection, and non‐time‐resolved PR acquisitions were used with the bolus‐chase technique to image the abdomen and thigh stations during a second injection. The streak artifacts resulting from undersampling the PR data were reduced with the use of a spatial Fermi filter based on the sensitivity of each coil element in a peripheral vascular phased‐array coil. This novel technique provided high spatial resolution and a broad range of coverage, and depicted the contrast dynamics in the most distal station of the lower extremities. Magn Reson Med 52:204–208, 2004.
- Open Access
- 26 April 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (5) , 1071-1076
Artifact reduction in undersampled projection reconstruction MRI of the peripheral vessels using selective excitation
The projection reconstruction (PR)-HyperTRICKS (time resolved imaging of contrast kinetics) acquisition integrates the benefits of through-plane Cartesian slice encoding and in-plane undersampled PR. It provides high spatial resolution both in-plane (about 1 mm2) and through-plane (1–2 mm), as well as relatively high temporal resolution (about 0.25 frames per second). However, undersampling artifacts that originate from anatomy superior or inferior to a coronal imaging FOV may severely degrade the image quality. In coronal MRA acquisitions, the slice coverage is limited in order to achieve high temporal resolution. In this report we describe an artifact reduction method that uses selective excitation in PR-HyperTRICKS. This technique significantly reduces undersampling streak artifacts while it increases the slice coverage. Magn Reson Med 51:1071–1076, 2004.
- 26 April 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (5) , 1071-1076
Open AccessArtifact reduction in undersampled projection reconstruction MRI of the peripheral vessels using selective excitation
The projection reconstruction (PR)-HyperTRICKS (time resolved imaging of contrast kinetics) acquisition integrates the benefits of through-plane Cartesian slice encoding and in-plane undersampled PR. It provides high spatial resolution both in-plane (about 1 mm2) and through-plane (1–2 mm), as well as relatively high temporal resolution (about 0.25 frames per second). However, undersampling artifacts that originate from anatomy superior or inferior to a coronal imaging FOV may severely degrade the image quality. In coronal MRA acquisitions, the slice coverage is limited in order to achieve high temporal resolution. In this report we describe an artifact reduction method that uses selective excitation in PR-HyperTRICKS. This technique significantly reduces undersampling streak artifacts while it increases the slice coverage. Magn Reson Med 51:1071–1076, 2004.
- Open Access
- 21 April 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (5) , 632-639
Noise reduction in MR angiography with nonlinear anisotropic filtering
Purpose To evaluate three-dimensional nonlinear anisotropic filtering in suppressing image noise in high spatial resolution magnetic resonance angiograms (MRA) acquired with hybrid undersampled projection reconstruction and phase contrast vastly undersampled isotropic projection reconstruction (PC-VIPR). Materials and Methods Three-dimensional nonlinear anisotropic filtering was quantitatively analyzed and evaluated through the measurement of contrast to noise ratio (CNR) in PC-VIPR images and contrast enhanced peripheral MRA images. To filter MRA images with ultra-high spatial resolution and poor CNR, a spatial frequency dependent nonlinear anisotropic filtering algorithm was proposed that uses two-step processing to filter the whole spatial frequency data. Results Three-dimensional nonlinear anisotropic filtering was shown to be effective in suppressing noise and improving CNR in MRA with isotropic spatial resolution. Higher CNR was achieved using spatial frequency dependent nonlinear anisotropic filtering. A typical CNR gain of between 50–100% was shown in our studies. Conclusion Three-dimensional nonlinear anisotropic filtering significantly improved CNR in MRA images with isotropic spatial resolution. Spatial frequency dependent nonlinear anisotropic filtering further improved CNR for MRA images with ultra-high spatial resolution and low CNR. J. Magn. Reson. Imaging 2004;19:632–639.
- 21 April 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (5) , 632-639
Open AccessNoise reduction in MR angiography with nonlinear anisotropic filtering
Purpose To evaluate three-dimensional nonlinear anisotropic filtering in suppressing image noise in high spatial resolution magnetic resonance angiograms (MRA) acquired with hybrid undersampled projection reconstruction and phase contrast vastly undersampled isotropic projection reconstruction (PC-VIPR). Materials and Methods Three-dimensional nonlinear anisotropic filtering was quantitatively analyzed and evaluated through the measurement of contrast to noise ratio (CNR) in PC-VIPR images and contrast enhanced peripheral MRA images. To filter MRA images with ultra-high spatial resolution and poor CNR, a spatial frequency dependent nonlinear anisotropic filtering algorithm was proposed that uses two-step processing to filter the whole spatial frequency data. Results Three-dimensional nonlinear anisotropic filtering was shown to be effective in suppressing noise and improving CNR in MRA with isotropic spatial resolution. Higher CNR was achieved using spatial frequency dependent nonlinear anisotropic filtering. A typical CNR gain of between 50–100% was shown in our studies. Conclusion Three-dimensional nonlinear anisotropic filtering significantly improved CNR in MRA images with isotropic spatial resolution. Spatial frequency dependent nonlinear anisotropic filtering further improved CNR for MRA images with ultra-high spatial resolution and low CNR. J. Magn. Reson. Imaging 2004;19:632–639.
- Open Access
- 23 August 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (3) , 516-522
Time‐resolved, undersampled projection reconstruction imaging for high‐resolution CE‐MRA of the distal runoff vessels
Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of the bolus of contrast agent in the distal extremities. Although time-resolved exams are robust in this respect, higher spatial resolution for the depiction of tight stenoses and the small vessels in the lower leg is desirable. A modification to a high-spatial-resolution T1-weighted pulse sequence (projection reconstruction-time resolved imaging of contrast kinetics (PR-TRICKS)) that improves the through-plane spatial resolution by a factor of 2 and maintains a high frame rate is presented. The undersampled PR-TRICKS pulse sequence has been modified to double the spatial resolution in the slice direction by acquiring high-spatial-frequency slice data only after first pass of the bolus of contrast agent. The acquisition reported in the present work (PR-hyperTRICKS) has been used to image healthy volunteers and patients with known vascular disease. The temporal resolution was found to be beneficial in capturing arterial phase images in the presence of asymmetric filling of vessels. Magn Reson Med 48:516–522, 2002.
- 23 August 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (3) , 516-522
Open AccessTime‐resolved, undersampled projection reconstruction imaging for high‐resolution CE‐MRA of the distal runoff vessels
Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of the bolus of contrast agent in the distal extremities. Although time-resolved exams are robust in this respect, higher spatial resolution for the depiction of tight stenoses and the small vessels in the lower leg is desirable. A modification to a high-spatial-resolution T1-weighted pulse sequence (projection reconstruction-time resolved imaging of contrast kinetics (PR-TRICKS)) that improves the through-plane spatial resolution by a factor of 2 and maintains a high frame rate is presented. The undersampled PR-TRICKS pulse sequence has been modified to double the spatial resolution in the slice direction by acquiring high-spatial-frequency slice data only after first pass of the bolus of contrast agent. The acquisition reported in the present work (PR-hyperTRICKS) has been used to image healthy volunteers and patients with known vascular disease. The temporal resolution was found to be beneficial in capturing arterial phase images in the presence of asymmetric filling of vessels. Magn Reson Med 48:516–522, 2002.