Brian R. Herts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian R. Herts has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
- Erick M. Remer
Section of Abdominal Imaging, Diagnostics Institute and Glickman Urological Institute, Cleveland Clinic, Cleveland, USA
6 shared publications Frank Dong
Department of Medical Physics – Desk AC‐211 Cleveland Clinic Imaging Institute Beachwood OH USA
6 shared publicationsMark E. Baker
All authors: Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Desk L10, Cleveland, OH 44195
5 shared publicationsErika Schneider
All authors: Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Desk L10, Cleveland, OH 44195
4 shared publicationsNancy Obuchowski
Imaging Institute, Cleveland Clinic, Desk Hb6, 9500 Euclid Ave, Cleveland, OH 44195
4 shared publications- Mark E. Baker
Imaging Department, Diagnostics Institute, Cleveland Clinic, Cleveland, USA
3 shared publications
Latest Publications
- 5 August 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1390-1398
Potential Frameworks for Communicating Diagnostic Certainty in Radiology Reports: From the ACR Commission on Quality and Safety
- 5 August 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1390-1398
Potential Frameworks for Communicating Diagnostic Certainty in Radiology Reports: From the ACR Commission on Quality and Safety
- 1 May 2021
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 41 (3) , E92-E93
Make Even Greater Radiology Reports
- 1 May 2021
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 41 (3) , E92-E93
Make Even Greater Radiology Reports
- Open Access
- 28 December 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (2) , 138-144
Effect of obesity on ability to lower exposure for detection of low‐attenuation liver lesions
Purpose: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low‐contrast low‐attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model.Methods: A phantom with four unique LCLA liver lesions (5‐ to 15‐mm spheres, –24 to –6 HU relative to 90‐HU background) was scanned without (“thin” phantom) and with (“obese” phantom) a 5‐cm thick fat‐attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model‐Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed.Results: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom.Conclusions: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.
- 28 December 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (2) , 138-144
Open AccessEffect of obesity on ability to lower exposure for detection of low‐attenuation liver lesions
Purpose: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low‐contrast low‐attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model.Methods: A phantom with four unique LCLA liver lesions (5‐ to 15‐mm spheres, –24 to –6 HU relative to 90‐HU background) was scanned without (“thin” phantom) and with (“obese” phantom) a 5‐cm thick fat‐attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model‐Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed.Results: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom.Conclusions: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.
- 1 March 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (3) , 490-496
How We Do It: Creating Consistent Structure and Content in Abdominal Radiology Report Templates
OBJECTIVE. The purposes of this article are to describe the creation of template report formats and content for a variety of abdominal and pelvic CT and MRI examinations and discuss a review-of-systems approach to text and avoidance of pitfalls of report templates. CONCLUSION. Organ system–specific report templates for CT and MRI incorporate radiologist preferences. Disease-specific report templates are created from these reports to provide a consistent radiologist and referring physician experience across the report templates.
- 1 March 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (3) , 490-496
How We Do It: Creating Consistent Structure and Content in Abdominal Radiology Report Templates
OBJECTIVE. The purposes of this article are to describe the creation of template report formats and content for a variety of abdominal and pelvic CT and MRI examinations and discuss a review-of-systems approach to text and avoidance of pitfalls of report templates. CONCLUSION. Organ system–specific report templates for CT and MRI incorporate radiologist preferences. Disease-specific report templates are created from these reports to provide a consistent radiologist and referring physician experience across the report templates.
- Top Cited Papers
- 1 February 2018
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 15 (2) , 264-273
Management of the Incidental Renal Mass on CT: A White Paper of the ACR Incidental Findings Committee
- 1 February 2018
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 15 (2) , 264-273
Top Cited PapersManagement of the Incidental Renal Mass on CT: A White Paper of the ACR Incidental Findings Committee
- 1 September 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (9) , 1025-1027
Authors’ Reply
- 1 September 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (9) , 1025-1027
Authors’ Reply
- 1 August 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (2) , 475-482
Image Noise, CNR, and Detectability of Low-Contrast, Low-Attenuation Liver Lesions in a Phantom: Effects of Radiation Exposure, Phantom Size, Integrated Circuit Detector, and Iterative Reconstruction
To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers’ confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. © RSNA, 2016 Online supplemental material is available for this article.
- 1 August 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (2) , 475-482
Image Noise, CNR, and Detectability of Low-Contrast, Low-Attenuation Liver Lesions in a Phantom: Effects of Radiation Exposure, Phantom Size, Integrated Circuit Detector, and Iterative Reconstruction
To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers’ confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. © RSNA, 2016 Online supplemental material is available for this article.
- 1 July 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (7) , 764-767
Rethinking Normal: Benefits and Risks of Not Reporting Harmless Incidental Findings
- 1 July 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (7) , 764-767
Rethinking Normal: Benefits and Risks of Not Reporting Harmless Incidental Findings
- 1 July 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (7) , 703-710
CT Radiation Dose Optimization and Tracking Program at a Large Quaternary-Care Health Care System
- 1 July 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (7) , 703-710
CT Radiation Dose Optimization and Tracking Program at a Large Quaternary-Care Health Care System