Sérgio Tadeu Martins Marba
Research Interests
Sérgio Tadeu Martins Marba has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Perazzini Facchini
Universidade Estadual de Campinas (UNICAMP), Campinas, SP, Brazil
2 shared publications Francisco Mezzacappa Filho
2 shared publications- Jamil Pedro de Siqueira Caldas
Universidade Estadual de Campinas, Brazil
2 shared publications Maria Aparecida Brenelli-Vitali
Universidade Estadual de Campinas, Campinas
2 shared publicationsMaria H. S. L. Blotta
Univ Estadual Campinas, Fac Ciencias Med, Dept Patol Clin, Campinas, SP, Brazil
2 shared publications- Mônica Barthelson C. de Moura
Universidade Estadual de Campinas, Campinas
2 shared publications
Latest Publications
- Open Access
- 1 December 2014
- Published by FapUNIFESP (SciELO) in Texto & Contexto - Enfermagem
- Vol. 23 (4) , 964-970
The evaluation of prolonged pain in the newborn: adaptation of the EDIN scale for the brazilian culture
This study aims to undertake the translation and cultural adaptation of the Échelle Douleur Inconfort Nouveau-Né scale into Brazilian Portuguese, following the steps recommended internationally: a) dual translation into Brazilian Portuguese; b) a synthesis of the translations; c) back translation into the original language; d) evaluation by a panel of judges; and e) pre-testing. All internationally recommended steps were performed satisfactorily. The panel of judges made alterations in most parts of the instrument, in order to keep the semantic, idiomatic, conceptual and cultural equivalences between the original and the translated versions. Pre-testing revealed the translated version is easy to understand and to fill out, and rapid to use. The translation and cultural adaption of the EDIN into Brazilian Portuguese were successfully completed.
- 1 December 2014
- Published by FapUNIFESP (SciELO) in Texto & Contexto - Enfermagem
- Vol. 23 (4) , 964-970
Open AccessThe evaluation of prolonged pain in the newborn: adaptation of the EDIN scale for the brazilian culture
This study aims to undertake the translation and cultural adaptation of the Échelle Douleur Inconfort Nouveau-Né scale into Brazilian Portuguese, following the steps recommended internationally: a) dual translation into Brazilian Portuguese; b) a synthesis of the translations; c) back translation into the original language; d) evaluation by a panel of judges; and e) pre-testing. All internationally recommended steps were performed satisfactorily. The panel of judges made alterations in most parts of the instrument, in order to keep the semantic, idiomatic, conceptual and cultural equivalences between the original and the translated versions. Pre-testing revealed the translated version is easy to understand and to fill out, and rapid to use. The translation and cultural adaption of the EDIN into Brazilian Portuguese were successfully completed.
- Open Access
- 1 April 2009
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 85 (2) , 175-178
Tendência secular do tempo de permanência hospitalar de recém-nascidos sadios: 1951-2000
OBJETIVO: Estudar a tendência secular da permanência hospitalar de recém-nascidos com peso > 2.500 g em uma maternidade de grande porte. MÉTODOS: Estudo descritivo, analítico e retrospectivo. Foram coletados dados de 5.001 nascidos vivos de 1951 a 2000, sadios, de gestação única. As variáveis estudadas foram: tempo de permanência hospitalar, peso, idade materna, tipo de parto e categoria de internação. Foi utilizada análise de regressão linear com estimação pelo método dos quadrados mínimos. RESULTADOS: A média anual da permanência hospitalar diminuiu no tempo estudado, sendo de 123 horas em 1951 e 67,2 horas em 2000. Utilizando-se método de regressão segmentada, evidenciou-se tendência significativa de queda no período entre 1951 e 1970, estabilização de 1971 a 1990 e discreto aumento, sem significado estatístico, a partir de 1991. A permanência hospitalar variou significativamente apenas com o tipo de parto. CONCLUSÃO: Houve decréscimo na permanência hospitalar no período estudado, devido apenas ao tipo de parto.
- 1 April 2009
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 85 (2) , 175-178
Open AccessTendência secular do tempo de permanência hospitalar de recém-nascidos sadios: 1951-2000
OBJETIVO: Estudar a tendência secular da permanência hospitalar de recém-nascidos com peso > 2.500 g em uma maternidade de grande porte. MÉTODOS: Estudo descritivo, analítico e retrospectivo. Foram coletados dados de 5.001 nascidos vivos de 1951 a 2000, sadios, de gestação única. As variáveis estudadas foram: tempo de permanência hospitalar, peso, idade materna, tipo de parto e categoria de internação. Foi utilizada análise de regressão linear com estimação pelo método dos quadrados mínimos. RESULTADOS: A média anual da permanência hospitalar diminuiu no tempo estudado, sendo de 123 horas em 1951 e 67,2 horas em 2000. Utilizando-se método de regressão segmentada, evidenciou-se tendência significativa de queda no período entre 1951 e 1970, estabilização de 1971 a 1990 e discreto aumento, sem significado estatístico, a partir de 1991. A permanência hospitalar variou significativamente apenas com o tipo de parto. CONCLUSÃO: Houve decréscimo na permanência hospitalar no período estudado, devido apenas ao tipo de parto.
- 23 March 2009
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 85 (3) , 217-22
Peak pressure and tidal volume are affected by how the neonatal self-inflating bag is handled
Objective: To evaluate how different ways of handling the neonatal self-inflating bag influence peak pressure and tidal volume. Methods: This is an experimental study involving 141 different professionals (physicians, resident physicians, physiotherapists, nurses, and nursing technicians), who ventilated an artificial lung, adjusted to simulate the lung of a term neonate, using a self-inflating bag. Each professional handled the ventilator in five different ways: a) using both hands (10 fingers); and, with only one hand, b) five fingers, c) four fingers, d) three fingers, and e) two fingers. Peak pressure and tidal volume data were recorded by the artificial lung equipment. Results: Both variables showed high variability, from 2.5 to 106.3 cmH2O (mean = 39.73 cmH2O; 95%CI 37.32-42.13) for peak pressure, and from to 4 to 88 mL (mean = 39.56 mL; 95%CI 36.86-42.25) for tidal volume. There was no significant influence of the profession on any of the variables (p > 0.05). However, bag handling significantly influenced both peak pressure and tidal volume (p < 0.0001), which were higher when the operator used both hands. Conclusion: The results indicate that most professionals delivered excessively high peak pressures and tidal volumes, which could increase the risk of barotrauma and volutrauma, especially when both hands were used to ventilate. On the other hand, a small number of professionals delivered insufficient pressure and volume for adequate lung expansion and ventilation. The delivery of inadequate ventilation was not dependent on profession. Copyright © 2009 by Sociedade Brasileira de Pediatria
- 23 March 2009
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 85 (3) , 217-22
Peak pressure and tidal volume are affected by how the neonatal self-inflating bag is handled
Objective: To evaluate how different ways of handling the neonatal self-inflating bag influence peak pressure and tidal volume. Methods: This is an experimental study involving 141 different professionals (physicians, resident physicians, physiotherapists, nurses, and nursing technicians), who ventilated an artificial lung, adjusted to simulate the lung of a term neonate, using a self-inflating bag. Each professional handled the ventilator in five different ways: a) using both hands (10 fingers); and, with only one hand, b) five fingers, c) four fingers, d) three fingers, and e) two fingers. Peak pressure and tidal volume data were recorded by the artificial lung equipment. Results: Both variables showed high variability, from 2.5 to 106.3 cmH2O (mean = 39.73 cmH2O; 95%CI 37.32-42.13) for peak pressure, and from to 4 to 88 mL (mean = 39.56 mL; 95%CI 36.86-42.25) for tidal volume. There was no significant influence of the profession on any of the variables (p > 0.05). However, bag handling significantly influenced both peak pressure and tidal volume (p < 0.0001), which were higher when the operator used both hands. Conclusion: The results indicate that most professionals delivered excessively high peak pressures and tidal volumes, which could increase the risk of barotrauma and volutrauma, especially when both hands were used to ventilate. On the other hand, a small number of professionals delivered insufficient pressure and volume for adequate lung expansion and ventilation. The delivery of inadequate ventilation was not dependent on profession. Copyright © 2009 by Sociedade Brasileira de Pediatria
- Open Access
- 5 March 2009
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 85 (2) , 175-8
Secular trend in length of hospital stay for healthy newborns: 1951-2000
To assess the secular trend in length of hospital stay for healthy newborns with birth weight >or= 2,500 g in a large maternity hospital of Campinas, state of São Paulo, Brazil. In this descriptive, analytical, retrospective study, data were collected from 5,001 live births from 1951 to 2000. Studied variables were length of hospital stay, birth weight, maternal age, type of delivery, and category of admission. Linear regression analysis was used, with least squares estimation. The annual mean length of stay decreased along the period assessed: 123 hours in 1951 and 67.2 hours in 2000. Segmented linear regression analysis revealed a significant decreasing trend between 1951 and 1970, a stable period between 1971 and 1990, and a non-significant increase between 1991 and 2000. Length of hospital stay varied significantly according to type of delivery. Length of hospital stay decreased significantly between 1951 and 2000 and was influenced by type of delivery only
- 5 March 2009
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 85 (2) , 175-8
Open AccessSecular trend in length of hospital stay for healthy newborns: 1951-2000
To assess the secular trend in length of hospital stay for healthy newborns with birth weight >or= 2,500 g in a large maternity hospital of Campinas, state of São Paulo, Brazil. In this descriptive, analytical, retrospective study, data were collected from 5,001 live births from 1951 to 2000. Studied variables were length of hospital stay, birth weight, maternal age, type of delivery, and category of admission. Linear regression analysis was used, with least squares estimation. The annual mean length of stay decreased along the period assessed: 123 hours in 1951 and 67.2 hours in 2000. Segmented linear regression analysis revealed a significant decreasing trend between 1951 and 1970, a stable period between 1971 and 1990, and a non-significant increase between 1991 and 2000. Length of hospital stay varied significantly according to type of delivery. Length of hospital stay decreased significantly between 1951 and 2000 and was influenced by type of delivery only
- 3 December 2008
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 84 (6) , 536-542
Accuracy of white blood cell count, C-reactive protein, interleukin-6 and tumor necrosis factor alpha for diagnosing late neonatal sepsis
Objective: To evaluate the diagnostic value for late neonatal sepsis of white blood cell count (WBC) and assays for C-reactive protein (CRP), interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-alpha), in isolation and in conjunction. Methods: This was a diagnostic test validation study. Chemiluminescence was used to assay CRP, IL-6 and TNF-alpha at the time of clinical suspicion and again after 24 and 48 hours, whereas the WBC was performed only once, at the time of suspicion. Patients were classified into three groups based on clinical progress and culture results: confirmed sepsis (CS), probable sepsis (PS), and not infected (NI). Statistical analysis was performed using the Wilcoxon and chi-square tests and Friedman analysis of variance; cutoffs were defined by plotting receiver operator characteristic curves. Results: The total study sample comprised 82 children, 42 of whom were classed as CS, 16 as PS and 24 as NI. At all three test times, the medians for CRP and IL-6 were significantly more elevated in the CS and PS groups, while the medians for TNF-alpha were abnormal only in the CS group. The CRP test had elevated indices of diagnostic utility at all three test times, better accuracy than the WBC and similar accuracy to the first IL-6 and TNF-alpha assays. There was no statistical difference between the cytokines, nor between them and the WBC. Combining tests did not increase diagnostic power, with the exception of the combination of WBC with CRP2 and when the sequential CRP assays were combined. Conclusions: Both CRP and WBC were useful for the diagnosis of late neonatal sepsis and comparable with IL-6 and TNF-alpha. Accuracy increased when CRP and WBC were combined and when sequential CRP assay results were used.
- 3 December 2008
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 84 (6) , 536-542
Accuracy of white blood cell count, C-reactive protein, interleukin-6 and tumor necrosis factor alpha for diagnosing late neonatal sepsis
Objective: To evaluate the diagnostic value for late neonatal sepsis of white blood cell count (WBC) and assays for C-reactive protein (CRP), interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-alpha), in isolation and in conjunction. Methods: This was a diagnostic test validation study. Chemiluminescence was used to assay CRP, IL-6 and TNF-alpha at the time of clinical suspicion and again after 24 and 48 hours, whereas the WBC was performed only once, at the time of suspicion. Patients were classified into three groups based on clinical progress and culture results: confirmed sepsis (CS), probable sepsis (PS), and not infected (NI). Statistical analysis was performed using the Wilcoxon and chi-square tests and Friedman analysis of variance; cutoffs were defined by plotting receiver operator characteristic curves. Results: The total study sample comprised 82 children, 42 of whom were classed as CS, 16 as PS and 24 as NI. At all three test times, the medians for CRP and IL-6 were significantly more elevated in the CS and PS groups, while the medians for TNF-alpha were abnormal only in the CS group. The CRP test had elevated indices of diagnostic utility at all three test times, better accuracy than the WBC and similar accuracy to the first IL-6 and TNF-alpha assays. There was no statistical difference between the cytokines, nor between them and the WBC. Combining tests did not increase diagnostic power, with the exception of the combination of WBC with CRP2 and when the sequential CRP assays were combined. Conclusions: Both CRP and WBC were useful for the diagnosis of late neonatal sepsis and comparable with IL-6 and TNF-alpha. Accuracy increased when CRP and WBC were combined and when sequential CRP assay results were used.
- 1 December 2008
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 84 (6) , 536-542
Acurácia diagnóstica do leucograma, proteína C-reativa, interleucina-6 e fator de necrose tumoral-alfa na sepse neonatal tardia
OBJECTIVE: To evaluate the diagnostic value for late neonatal sepsis of white blood cell count (WBC) and assays for C-reactive protein (CRP), interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α), in isolation and in conjunction. METHODS: This was a diagnostic test validation study. Chemiluminescence was used to assay CRP, IL-6 and TNF-α at the time of clinical suspicion and again after 24 and 48 hours, whereas the WBC was performed only once, at the time of suspicion. Patients were classified into three groups based on clinical progress and culture results: confirmed sepsis (CS), probable sepsis (PS), and not infected (NI). Statistical analysis was performed using the Wilcoxon and chi-square tests and Friedman analysis of variance; cutoffs were defined by plotting receiver operator characteristic curves. RESULTS: The total study sample comprised 82 children, 42 of whom were classed as CS, 16 as PS and 24 as NI. At all three test times, the medians for CRP and IL-6 were significantly more elevated in the CS and PS groups, while the medians for TNF-α were abnormal only in the CS group. The CRP test had elevated indices of diagnostic utility at all three test times, better accuracy than the WBC and similar accuracy to the first IL-6 and TNF-α assays. There was no statistical difference between the cytokines, nor between them and the WBC. Combining tests did not increase diagnostic power, with the exception of the combination of WBC with CRP2 and when the sequential CRP assays were combined. CONCLUSIONS: Both CRP and WBC were useful for the diagnosis of late neonatal sepsis and comparable with IL-6 and TNF-α. Accuracy increased when CRP and WBC were combined and when sequential CRP assay results were used.OBJETIVO: Avaliar o valor do leucograma, proteína C-reativa (PCR), interleucina-6 (IL-6) e do fator de necrose tumoral-alfa (TNF-α), isoladamente e em conjunto, na detecção da sepse neonatal tardia. MÉTODOS: Estudo de validação diagnóstica. A PCR, IL-6 e TNF-α foram dosados por quimioluminescência à suspeita clínica, 24 e 48 horas depois, e o leucograma unicamente à suspeita. De acordo com evolução clínica e resultados de culturas, três grupos foram definidos: sepse comprovada (SC), sepse provável (SP) e não infectados (NI). Os testes estatísticos utilizados foram os de Wilcoxon, qui-quadrado e análise de variância de Friedman e os limites de corte foram obtidos pela construção da curva ROC. RESULTADOS: Estudaram-se 82 crianças, sendo 42 no grupo SC, 16 no SP e 24 NI. Nos três momentos, as medianas da PCR e da IL-6 mostraram-se significativamente mais elevadas nos grupos SC e SP, e as do TNF-α alteraram-se apenas no grupo SC. Os índices diagnósticos da PCR foram elevados nos três momentos e com acurácia superior a do leucograma e semelhante a da IL-6 e a do TNF-α em suas primeiras medidas. Entre as citocinas, não houve diferença estatística entre elas, nem em relação ao leucograma. A associação dos testes não aumentou a capacidade diagnóstica, exceto na combinação entre leucograma e PCR2 e na dosagem seriada de PCR. CONCLUSÕES: A PCR e o leucograma mostram-se úteis no diagnóstico de sepse neonatal tardia e comparáveis à IL-6 e ao TNF-α. A acurácia aumentou com a associação PCR-leucograma e a dosagem seriada da PCR
- 1 December 2008
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 84 (6) , 536-542
Acurácia diagnóstica do leucograma, proteína C-reativa, interleucina-6 e fator de necrose tumoral-alfa na sepse neonatal tardia
OBJECTIVE: To evaluate the diagnostic value for late neonatal sepsis of white blood cell count (WBC) and assays for C-reactive protein (CRP), interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α), in isolation and in conjunction. METHODS: This was a diagnostic test validation study. Chemiluminescence was used to assay CRP, IL-6 and TNF-α at the time of clinical suspicion and again after 24 and 48 hours, whereas the WBC was performed only once, at the time of suspicion. Patients were classified into three groups based on clinical progress and culture results: confirmed sepsis (CS), probable sepsis (PS), and not infected (NI). Statistical analysis was performed using the Wilcoxon and chi-square tests and Friedman analysis of variance; cutoffs were defined by plotting receiver operator characteristic curves. RESULTS: The total study sample comprised 82 children, 42 of whom were classed as CS, 16 as PS and 24 as NI. At all three test times, the medians for CRP and IL-6 were significantly more elevated in the CS and PS groups, while the medians for TNF-α were abnormal only in the CS group. The CRP test had elevated indices of diagnostic utility at all three test times, better accuracy than the WBC and similar accuracy to the first IL-6 and TNF-α assays. There was no statistical difference between the cytokines, nor between them and the WBC. Combining tests did not increase diagnostic power, with the exception of the combination of WBC with CRP2 and when the sequential CRP assays were combined. CONCLUSIONS: Both CRP and WBC were useful for the diagnosis of late neonatal sepsis and comparable with IL-6 and TNF-α. Accuracy increased when CRP and WBC were combined and when sequential CRP assay results were used.OBJETIVO: Avaliar o valor do leucograma, proteína C-reativa (PCR), interleucina-6 (IL-6) e do fator de necrose tumoral-alfa (TNF-α), isoladamente e em conjunto, na detecção da sepse neonatal tardia. MÉTODOS: Estudo de validação diagnóstica. A PCR, IL-6 e TNF-α foram dosados por quimioluminescência à suspeita clínica, 24 e 48 horas depois, e o leucograma unicamente à suspeita. De acordo com evolução clínica e resultados de culturas, três grupos foram definidos: sepse comprovada (SC), sepse provável (SP) e não infectados (NI). Os testes estatísticos utilizados foram os de Wilcoxon, qui-quadrado e análise de variância de Friedman e os limites de corte foram obtidos pela construção da curva ROC. RESULTADOS: Estudaram-se 82 crianças, sendo 42 no grupo SC, 16 no SP e 24 NI. Nos três momentos, as medianas da PCR e da IL-6 mostraram-se significativamente mais elevadas nos grupos SC e SP, e as do TNF-α alteraram-se apenas no grupo SC. Os índices diagnósticos da PCR foram elevados nos três momentos e com acurácia superior a do leucograma e semelhante a da IL-6 e a do TNF-α em suas primeiras medidas. Entre as citocinas, não houve diferença estatística entre elas, nem em relação ao leucograma. A associação dos testes não aumentou a capacidade diagnóstica, exceto na combinação entre leucograma e PCR2 e na dosagem seriada de PCR. CONCLUSÕES: A PCR e o leucograma mostram-se úteis no diagnóstico de sepse neonatal tardia e comparáveis à IL-6 e ao TNF-α. A acurácia aumentou com a associação PCR-leucograma e a dosagem seriada da PCR
- 1 July 2007
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 83 (4) , 313-318
Follow-up of neonatal jaundice in term and late premature newborns
To report on the results of a project following term and near term newborn infants who were jaundiced during the neonatal period. Neonates were referred to the follow-up clinic with weight >/= 2,000 g and/or gestational age >/= 35 weeks, and jaundice at discharge was initially assessed with an Ingram icterometer or Bilicheck and, if indicated, with a Unistat bilirubinometer (Leica). These newborn infants had bilirubinemia at or above the 40th percentile on the nomogram developed by Bhutani. All infants treated with phototherapy while in hospital were reassessed by laboratory methods 24 hours after withdrawal of treatment. Patients were rehospitalized for intensive phototherapy if their level was greater than or equal to 20 mg/dL. From a total sample of 11,259 neonates, 2,452 (21.8%) were referred to the follow-up clinic, 87.2% (2,140) of whom did return. Eighty returned neonates were readmitted. Return appointments were set for 2,452 patients, 180 (7.3%) of whom had bilirubinemia >/= 15 mg/dL at discharge. Of these 180, 151 returned for follow-up. Twenty (13.2%) were readmitted for treatment. Of the total number of readmitted patients, two newborn infants had levels >/= 25 mg/dL and none >/= 30 mg/dL. All responded rapidly to intensive phototherapy, and there was no need for exchange transfusions. Our results suggest that the regime adopted is effective for detecting and preventing hyperbilirubinemia at risk of causing bilirubin-induced encephalopathy in term and near term newborn infants
- 1 July 2007
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 83 (4) , 313-318
Follow-up of neonatal jaundice in term and late premature newborns
To report on the results of a project following term and near term newborn infants who were jaundiced during the neonatal period. Neonates were referred to the follow-up clinic with weight >/= 2,000 g and/or gestational age >/= 35 weeks, and jaundice at discharge was initially assessed with an Ingram icterometer or Bilicheck and, if indicated, with a Unistat bilirubinometer (Leica). These newborn infants had bilirubinemia at or above the 40th percentile on the nomogram developed by Bhutani. All infants treated with phototherapy while in hospital were reassessed by laboratory methods 24 hours after withdrawal of treatment. Patients were rehospitalized for intensive phototherapy if their level was greater than or equal to 20 mg/dL. From a total sample of 11,259 neonates, 2,452 (21.8%) were referred to the follow-up clinic, 87.2% (2,140) of whom did return. Eighty returned neonates were readmitted. Return appointments were set for 2,452 patients, 180 (7.3%) of whom had bilirubinemia >/= 15 mg/dL at discharge. Of these 180, 151 returned for follow-up. Twenty (13.2%) were readmitted for treatment. Of the total number of readmitted patients, two newborn infants had levels >/= 25 mg/dL and none >/= 30 mg/dL. All responded rapidly to intensive phototherapy, and there was no need for exchange transfusions. Our results suggest that the regime adopted is effective for detecting and preventing hyperbilirubinemia at risk of causing bilirubin-induced encephalopathy in term and near term newborn infants
- 1 June 2007
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 83 (3) , 283-286
Comparison of transcutaneous and plasma bilirubin measurement
To compare transcutaneous bilirubin measurements made using Bilicheck equipment with assays of capillary plasma using the Unistat bilirubinometer (Leica). Two hundred concomitant assays were performed (transcutaneous and in plasma), and the correlation and level of agreement between them was calculated. An assessment was also made of the influence of birth weight, skin color, gestational age, postnatal age and phototherapy. The linear correlation coefficient was 0.92, and the mean difference between assays was 0.72 (+/-1.57) mg/dL, with a 95% confidence interval from -2.42 to +3.86. The best of a series of ROC curves demonstrated that transcutaneous assays at 14 mg/dL offer the best sensitivity (88.2%) and specificity (97.8%), with a positive predictive value of 78.9%, negative predictive value of 98.9 and are below the curve of 0.98. Assays performed using Bilicheck can be substituted for capillary plasma assays up to 14 mg/dL. Above this level the device should only be used for screening for patients whose bilirubin should be assayed in blood.
- 1 June 2007
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 83 (3) , 283-286
Comparison of transcutaneous and plasma bilirubin measurement
To compare transcutaneous bilirubin measurements made using Bilicheck equipment with assays of capillary plasma using the Unistat bilirubinometer (Leica). Two hundred concomitant assays were performed (transcutaneous and in plasma), and the correlation and level of agreement between them was calculated. An assessment was also made of the influence of birth weight, skin color, gestational age, postnatal age and phototherapy. The linear correlation coefficient was 0.92, and the mean difference between assays was 0.72 (+/-1.57) mg/dL, with a 95% confidence interval from -2.42 to +3.86. The best of a series of ROC curves demonstrated that transcutaneous assays at 14 mg/dL offer the best sensitivity (88.2%) and specificity (97.8%), with a positive predictive value of 78.9%, negative predictive value of 98.9 and are below the curve of 0.98. Assays performed using Bilicheck can be substituted for capillary plasma assays up to 14 mg/dL. Above this level the device should only be used for screening for patients whose bilirubin should be assayed in blood.
- Open Access
- 7 April 2006
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 82 (2) , 110-114
Hearing screening in a neonatal intensive care unit
Investigate the prevalence of hearing impairment in newborns hospitalized at the Intensive and Intermediate Care Unit at the Women's Comprehensive Health Center Neonatology Service (UNICAMP) and associated risk factors. 979 newborn babies were assessed between January 2000 and January 2003, through automated auditory brainstem response (AABR) (ALGO 2e color screener). The result was considered normal when the newborn showed response to a 35dBNA signal bilaterally. The prevalence of AABR impairment and the odds ratio were analyzed with a 95% confidence interval using bivariate analysis. To identify the independent risk factors for hearing alterations, multivariate analyses were used with logistic regression. The prevalence of AABR impairment was 10.2%, of which 5.3% was unilateral and 4.9% bilateral. From the multivariate analyses, the following observations were made: family history of congenital hearing loss (OR = 5.192; p = 0.016), craniofacial deformity (OR = 5.530; p < 0.001), genetic syndromes associated with hearing loss (OR = 4.212; p < 0.001), weight below 1,000 g (OR = 3.230; p < 0.001), asphyxia (OR = 3.532; p < 0.001), hyperbilirubinemia (OR = 4.099; p = 0.002) and use of mechanical ventilation (OR = 1.826; p < 0.031) were the indicators that best characterized the group at risk for hearing impairment. The prevalence of hearing impairment using AABR is high. Therefore, it is essential for all newborns who present isolated or associated risk factors to undergo hearing screening in situations in which it is not possible to have universal hearing screening.
- 7 April 2006
- Published by Fundacao Sociedade Brasileira de Pediatria in Jornal de Pediatria
- Vol. 82 (2) , 110-114
Open AccessHearing screening in a neonatal intensive care unit
Investigate the prevalence of hearing impairment in newborns hospitalized at the Intensive and Intermediate Care Unit at the Women's Comprehensive Health Center Neonatology Service (UNICAMP) and associated risk factors. 979 newborn babies were assessed between January 2000 and January 2003, through automated auditory brainstem response (AABR) (ALGO 2e color screener). The result was considered normal when the newborn showed response to a 35dBNA signal bilaterally. The prevalence of AABR impairment and the odds ratio were analyzed with a 95% confidence interval using bivariate analysis. To identify the independent risk factors for hearing alterations, multivariate analyses were used with logistic regression. The prevalence of AABR impairment was 10.2%, of which 5.3% was unilateral and 4.9% bilateral. From the multivariate analyses, the following observations were made: family history of congenital hearing loss (OR = 5.192; p = 0.016), craniofacial deformity (OR = 5.530; p < 0.001), genetic syndromes associated with hearing loss (OR = 4.212; p < 0.001), weight below 1,000 g (OR = 3.230; p < 0.001), asphyxia (OR = 3.532; p < 0.001), hyperbilirubinemia (OR = 4.099; p = 0.002) and use of mechanical ventilation (OR = 1.826; p < 0.031) were the indicators that best characterized the group at risk for hearing impairment. The prevalence of hearing impairment using AABR is high. Therefore, it is essential for all newborns who present isolated or associated risk factors to undergo hearing screening in situations in which it is not possible to have universal hearing screening.
- Open Access
- 1 April 2006
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 82 (2) , 110-114
Triagem auditiva em recém-nascidos internados em UTI neonatal
OBJECTIVE: Investigate the prevalence of hearing impairment in newborns hospitalized at the Intensive and Intermediate Care Unit at the Women's Comprehensive Health Center Neonatology Service (UNICAMP) and associated risk factors. METHODS: 979 newborn babies were assessed between January 2000 and January 2003, through automated auditory brainstem response (AABR) (ALGO 2e color screener). The result was considered normal when the newborn showed response to a 35dBNA signal bilaterally. The prevalence of AABR impairment and the odds ratio were analyzed with a 95% confidence interval using bivariate analysis. To identify the independent risk factors for hearing alterations, multivariate analyses were used with logistic regression. RESULTS: The prevalence of AABR impairment was 10.2%, of which 5.3% was unilateral and 4.9% bilateral. From the multivariate analyses, the following observations were made: family history of congenital hearing loss (OR = 5.192; p = 0.016), craniofacial deformity (OR = 5.530; p < 0.001), genetic syndromes associated with hearing loss (OR = 4.212; p < 0.001), weight below 1,000 g (OR = 3.230; p < 0.001), asphyxia (OR = 3.532; p < 0.001), hyperbilirubinemia (OR = 4.099; p = 0.002) and use of mechanical ventilation (OR = 1.826; p < 0.031) were the indicators that best characterized the group at risk for hearing impairment. CONCLUSIONS: The prevalence of hearing impairment using AABR is high. Therefore, it is essential for all newborns who present isolated or associated risk factors to undergo hearing screening in situations in which it is not possible to have universal hearing screening.OBJETIVO: Avaliar a prevalência de alterações auditivas em recém-nascidos internados na unidade de terapia intensiva e cuidados intermediários do serviço de neonatologia do Centro de Assistência Integral à Saúde da Mulher, Faculdade de Ciências Médicas, Universidade Estadual de Campinas, e analisar os fatores de risco associados. MÉTODOS: Foram avaliados 979 recém-nascidos no período de janeiro de 2000 a janeiro de 2003, utilizando-se a audiometria automática de tronco encefálico (AABR), com aparelho ALGO-2e color - Natus. O resultado foi considerado normal quando o recém-nascido apresentou resposta para 35 dBNA bilateralmente. Foi analisada a prevalência de AABR alterada e odds ratio com intervalo de confiança de 95% em análise bivariada. Para identificar os fatores de risco independentes para AABR alterada, foi feita análise múltipla com modelo de regressão logística. RESULTADOS: A prevalência de alteração no AABR foi de 10,2%, sendo 5,3% unilateral e 4,9% bilateral. Pela análise multivariada, observamos que: antecedente familiar (OR = 5,192; p = 0,016), malformação craniofacial (OR = 5,530; p < 0,001), síndrome genética (OR = 4,212; p < 0,001), peso menor que 1.000 g (OR = 3,230; p < 0,001), asfixia (OR = 3,532; p < 0,001), hiperbilirrubinemia (OR = 4,099; p = 0,002) e uso de ventilação mecânica (OR = 1,826; p < 0,031) foram os indicadores que melhor caracterizaram um grupo de risco para perda auditiva. CONCLUSÕES: A prevalência de alteração auditiva pela AABR é elevada. É essencial que todos os recém-nascidos que apresentam fatores de risco associados ou isolados passem por avaliação auditiva nas situações em que não seja possível ter a triagem universal
- 1 April 2006
- Published by FapUNIFESP (SciELO) in Jornal de Pediatria
- Vol. 82 (2) , 110-114
Open AccessTriagem auditiva em recém-nascidos internados em UTI neonatal
OBJECTIVE: Investigate the prevalence of hearing impairment in newborns hospitalized at the Intensive and Intermediate Care Unit at the Women's Comprehensive Health Center Neonatology Service (UNICAMP) and associated risk factors. METHODS: 979 newborn babies were assessed between January 2000 and January 2003, through automated auditory brainstem response (AABR) (ALGO 2e color screener). The result was considered normal when the newborn showed response to a 35dBNA signal bilaterally. The prevalence of AABR impairment and the odds ratio were analyzed with a 95% confidence interval using bivariate analysis. To identify the independent risk factors for hearing alterations, multivariate analyses were used with logistic regression. RESULTS: The prevalence of AABR impairment was 10.2%, of which 5.3% was unilateral and 4.9% bilateral. From the multivariate analyses, the following observations were made: family history of congenital hearing loss (OR = 5.192; p = 0.016), craniofacial deformity (OR = 5.530; p < 0.001), genetic syndromes associated with hearing loss (OR = 4.212; p < 0.001), weight below 1,000 g (OR = 3.230; p < 0.001), asphyxia (OR = 3.532; p < 0.001), hyperbilirubinemia (OR = 4.099; p = 0.002) and use of mechanical ventilation (OR = 1.826; p < 0.031) were the indicators that best characterized the group at risk for hearing impairment. CONCLUSIONS: The prevalence of hearing impairment using AABR is high. Therefore, it is essential for all newborns who present isolated or associated risk factors to undergo hearing screening in situations in which it is not possible to have universal hearing screening.OBJETIVO: Avaliar a prevalência de alterações auditivas em recém-nascidos internados na unidade de terapia intensiva e cuidados intermediários do serviço de neonatologia do Centro de Assistência Integral à Saúde da Mulher, Faculdade de Ciências Médicas, Universidade Estadual de Campinas, e analisar os fatores de risco associados. MÉTODOS: Foram avaliados 979 recém-nascidos no período de janeiro de 2000 a janeiro de 2003, utilizando-se a audiometria automática de tronco encefálico (AABR), com aparelho ALGO-2e color - Natus. O resultado foi considerado normal quando o recém-nascido apresentou resposta para 35 dBNA bilateralmente. Foi analisada a prevalência de AABR alterada e odds ratio com intervalo de confiança de 95% em análise bivariada. Para identificar os fatores de risco independentes para AABR alterada, foi feita análise múltipla com modelo de regressão logística. RESULTADOS: A prevalência de alteração no AABR foi de 10,2%, sendo 5,3% unilateral e 4,9% bilateral. Pela análise multivariada, observamos que: antecedente familiar (OR = 5,192; p = 0,016), malformação craniofacial (OR = 5,530; p < 0,001), síndrome genética (OR = 4,212; p < 0,001), peso menor que 1.000 g (OR = 3,230; p < 0,001), asfixia (OR = 3,532; p < 0,001), hiperbilirrubinemia (OR = 4,099; p = 0,002) e uso de ventilação mecânica (OR = 1,826; p < 0,031) foram os indicadores que melhor caracterizaram um grupo de risco para perda auditiva. CONCLUSÕES: A prevalência de alteração auditiva pela AABR é elevada. É essencial que todos os recém-nascidos que apresentam fatores de risco associados ou isolados passem por avaliação auditiva nas situações em que não seja possível ter a triagem universal