Arthur C K Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arthur C K Cheng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Dennis S C Lam
4 shared publicationsAlvin L Young
2 shared publicationsDennis S.C Lam
2 shared publicationsRicky W.K Law
2 shared publicationsAlvin L.M Young
1 shared publication- Dennis Shun Chiu Lam
Department of Ophthalmology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
1 shared publication
Latest Publications
- 1 December 2007
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (12) , 2049-2053
Comparison of corneal flap thickness between primary eyes and fellow eyes using the Zyoptix XP microkeratome
To evaluate corneal flap thickness created in myopic laser in situ keratomileusis (LASIK) using the Zyoptix XP 120 microkeratome (Bausch & Lomb).University-based eye clinic.Corneal thickness was measured preoperatively and intraoperatively after flap creation in 62 consecutive patients (124 eyes) who had LASIK for the correction of myopia. Corneal flap thickness was calculated by subtracting stromal bed thickness from total corneal thickness. In each patient, both corneas (right followed by left) were cut by 1 the same Zyoptix XP 120 microkeratome blade at the same session.The mean actual flap thickness was 115.34 microm +/- 16.34 (SD) in right eyes and 104.55 +/- 14.34 mum in left eyes. The mean actual flap thickness in right eyes was not statistically significantly different from the 120 microm proposed by the manufacturer (P = .142); however, the mean actual flap thickness in left eyes was statistically significantly different from the 120 microm (P<.001). The mean flap thickness in the second eye was also statistically significantly thinner than in the first eye (P<.001).The corneal flaps were thinner than expected when a Zyoptix XP 120 microkeratome was used in LASIK. Although the first cuts produced thinner flaps, this difference was not statistically significant. However, the second cuts produced significantly thinner flaps.
- 1 December 2007
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (12) , 2049-2053
Comparison of corneal flap thickness between primary eyes and fellow eyes using the Zyoptix XP microkeratome
To evaluate corneal flap thickness created in myopic laser in situ keratomileusis (LASIK) using the Zyoptix XP 120 microkeratome (Bausch & Lomb).University-based eye clinic.Corneal thickness was measured preoperatively and intraoperatively after flap creation in 62 consecutive patients (124 eyes) who had LASIK for the correction of myopia. Corneal flap thickness was calculated by subtracting stromal bed thickness from total corneal thickness. In each patient, both corneas (right followed by left) were cut by 1 the same Zyoptix XP 120 microkeratome blade at the same session.The mean actual flap thickness was 115.34 microm +/- 16.34 (SD) in right eyes and 104.55 +/- 14.34 mum in left eyes. The mean actual flap thickness in right eyes was not statistically significantly different from the 120 microm proposed by the manufacturer (P = .142); however, the mean actual flap thickness in left eyes was statistically significantly different from the 120 microm (P<.001). The mean flap thickness in the second eye was also statistically significantly thinner than in the first eye (P<.001).The corneal flaps were thinner than expected when a Zyoptix XP 120 microkeratome was used in LASIK. Although the first cuts produced thinner flaps, this difference was not statistically significant. However, the second cuts produced significantly thinner flaps.
- 1 April 2006
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 22 (4) , 363-366
Pachymetry Assessment With Orbscan II in Postoperative Patients With Myopic LASIK
PURPOSE: To compare central corneal thickness after LASIK for myopia, using ultrasonic pachymetry and Orbscan Il measurements, and to evaluate changes in these measurements over time. METHODS: Central corneal thickness measurements obtained by ultrasonic pachymetry and Orbscan Il (Bausch & Lomb, Rochester, NY) in patients who underwent myopic LASIK between July 2002 and May 2003 were analyzed. The two measurements were assessed preoperatively and postoperatively at 1 day and 1,3,6, and 12 months. RESULTS: In 237 eyes, using the correction factor 0.93, no significant difference was noted in the preoperative central corneal thickness measured by ultrasonic pachymetry (561. 89 ?28.66 ???) and Orbscan pachymetry (562. 28 ?28.18 /im) (P=. 713). Postoperatively, the difference was statistically significant at day 1 and 1, 3, and 6 months (P<.001), but was not significant at 12 months (P=. 130). CONCLUSIONS: Orbscan Il measurements of central corneal thickness after myopic LASIK are less than those measured by ultrasonic pachymetry; however, this difference decreases with time and may not be significant after 1 year. [J Refract Surg. 2006;22:363-366.]
- 1 April 2006
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 22 (4) , 363-366
Pachymetry Assessment With Orbscan II in Postoperative Patients With Myopic LASIK
PURPOSE: To compare central corneal thickness after LASIK for myopia, using ultrasonic pachymetry and Orbscan Il measurements, and to evaluate changes in these measurements over time. METHODS: Central corneal thickness measurements obtained by ultrasonic pachymetry and Orbscan Il (Bausch & Lomb, Rochester, NY) in patients who underwent myopic LASIK between July 2002 and May 2003 were analyzed. The two measurements were assessed preoperatively and postoperatively at 1 day and 1,3,6, and 12 months. RESULTS: In 237 eyes, using the correction factor 0.93, no significant difference was noted in the preoperative central corneal thickness measured by ultrasonic pachymetry (561. 89 ?28.66 ???) and Orbscan pachymetry (562. 28 ?28.18 /im) (P=. 713). Postoperatively, the difference was statistically significant at day 1 and 1, 3, and 6 months (P<.001), but was not significant at 12 months (P=. 130). CONCLUSIONS: Orbscan Il measurements of central corneal thickness after myopic LASIK are less than those measured by ultrasonic pachymetry; however, this difference decreases with time and may not be significant after 1 year. [J Refract Surg. 2006;22:363-366.]
- 22 July 2005
- Published by Springer Nature in Eye
- Vol. 20 (7) , 850
Surgical management of iris defects with prosthetic iris devices
- 22 July 2005
- Published by Springer Nature in Eye
- Vol. 20 (7) , 850
Surgical management of iris defects with prosthetic iris devices
- Open Access
- 22 July 2005
- Published by Springer Nature in Eye
- Vol. 20 (7) , 848-849
The Ahmed glaucoma valve in refractory glaucoma: experiences in Indian eyes
- 22 July 2005
- Published by Springer Nature in Eye
- Vol. 20 (7) , 848-849
Open AccessThe Ahmed glaucoma valve in refractory glaucoma: experiences in Indian eyes
- 1 July 2005
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 21 (4) , 365-368
Keratometry for Intraocular Lens Power Calculation Using Orbscan II in Eyes With Laser in situ Keratomileusis
PURPOSE: To compare the results of corneal keratometry after laser in situ keratomileusis (LASIK) obtained by the Gaussian optics formula and the clinical history method. METHODS: Sixty-one consecutive patients (121 eyes) who had undergone LASIK were recruited in this retrospective case-controlled study. The K-value obtained from the Gaussian optics formula (CalK) based on postoperative corneal topography by Orbscan II (Bausch & Lomb, Rochester, NY) and ultrasound pachymetry was compared with that obtained from the clinical history method (estK). Keratometry measured by these two methods was compared using the paired sample t test and Pearson correlation coefficient. RESULTS: A high correlation was noted between K-value obtained by the clinical history method and the Gaussian optics formula (R = 0.97, P<.001). The mean difference between the two methods is 0.13 diopters (P=.06). CONCLUSIONS: K reading derived from the Gaussian optics formula correlated closely to that obtained from the clinical history method and would be especially useful in patients with no preoperative LASIK treatment data. [J Refract Surg. 2005;21:365-368.]
- 1 July 2005
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 21 (4) , 365-368
Keratometry for Intraocular Lens Power Calculation Using Orbscan II in Eyes With Laser in situ Keratomileusis
PURPOSE: To compare the results of corneal keratometry after laser in situ keratomileusis (LASIK) obtained by the Gaussian optics formula and the clinical history method. METHODS: Sixty-one consecutive patients (121 eyes) who had undergone LASIK were recruited in this retrospective case-controlled study. The K-value obtained from the Gaussian optics formula (CalK) based on postoperative corneal topography by Orbscan II (Bausch & Lomb, Rochester, NY) and ultrasound pachymetry was compared with that obtained from the clinical history method (estK). Keratometry measured by these two methods was compared using the paired sample t test and Pearson correlation coefficient. RESULTS: A high correlation was noted between K-value obtained by the clinical history method and the Gaussian optics formula (R = 0.97, P<.001). The mean difference between the two methods is 0.13 diopters (P=.06). CONCLUSIONS: K reading derived from the Gaussian optics formula correlated closely to that obtained from the clinical history method and would be especially useful in patients with no preoperative LASIK treatment data. [J Refract Surg. 2005;21:365-368.]
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (7) , 1545-1548
Effect of alcohol on the efficacy of excimer laser power
Alibration procedure. The effect of ethanol 20%, 40%, 60%, and 80% and sodium hypochlorite 0.06% solutions on laser fluency was assessed in 5 experiments. Results: Ethanol concentrations of 20% and 40% had no significant effect on laser fluency. Ethanol concentrations of 60% and 80% reduced fluency to 97.6%. Sodium hypochlorite had no effect on laser fluency. Conclusions: A high concentration of ethanol affected laser fluency and should be avoided in the operating theater. Ethanol 20%, which is commonly used during laser-assisted subepithelial keratectomy, did not affect laser fluency....
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (7) , 1545-1548
Effect of alcohol on the efficacy of excimer laser power
Alibration procedure. The effect of ethanol 20%, 40%, 60%, and 80% and sodium hypochlorite 0.06% solutions on laser fluency was assessed in 5 experiments. Results: Ethanol concentrations of 20% and 40% had no significant effect on laser fluency. Ethanol concentrations of 60% and 80% reduced fluency to 97.6%. Sodium hypochlorite had no effect on laser fluency. Conclusions: A high concentration of ethanol affected laser fluency and should be avoided in the operating theater. Ethanol 20%, which is commonly used during laser-assisted subepithelial keratectomy, did not affect laser fluency....
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (7) , 1572-1574
Ptosis after laser in situ keratomileusis
We present a patient who developed partial ptosis after laser in situ keratomileusis.
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (7) , 1572-1574
Ptosis after laser in situ keratomileusis
We present a patient who developed partial ptosis after laser in situ keratomileusis.
- 1 May 2004
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 20 (3) , 248-252
Comparison of the Colvard Pupillometer and the Zywave for Measuring Scotopic Pupil Diameter
PURPOSE: To evaluate the accuracy and repeatability of two pupillometers. METHODS: Two pupillometers, the Colvard and Zywave, were used to measure scotopic pupil diameter for 64 consecutive patients. Accuracy and repeatability were assessed by two independent examiners and statistical analysis was performed using the comparison method described by Bland and Altman. RESULTS: Mean scotopic pupil diameter was 5.96 ± 0.69 mm with the Colvard pupillometer and 5.77 ± 0.85 mm with the Zywave. The difference between the Colvard and Zywave measurements was 0.21 ± 0.56 mm (P<.001). The coefficient of interrater repeatability was smaller for the Colvard (0.59) than for the Zywave (1.17). The mean difference between the pupillometers for each examiner was 0.17 ± 0.47 mm (P<.01) for examiner 1 and 0.26 ± 0.64 mm (P<.01) for examiner 2. CONCLUSIONS: Scotopic pupil diameter measured with the Zywave was statistically but not clinically significantly smaller than that measured with the Colvard pupillometer. The Zywave produced an inter-rater repeatability comparable to other devices although not as good as the Colvard pupillometer. [J Refract Surg 2004;20:248-252]
- 1 May 2004
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 20 (3) , 248-252
Comparison of the Colvard Pupillometer and the Zywave for Measuring Scotopic Pupil Diameter
PURPOSE: To evaluate the accuracy and repeatability of two pupillometers. METHODS: Two pupillometers, the Colvard and Zywave, were used to measure scotopic pupil diameter for 64 consecutive patients. Accuracy and repeatability were assessed by two independent examiners and statistical analysis was performed using the comparison method described by Bland and Altman. RESULTS: Mean scotopic pupil diameter was 5.96 ± 0.69 mm with the Colvard pupillometer and 5.77 ± 0.85 mm with the Zywave. The difference between the Colvard and Zywave measurements was 0.21 ± 0.56 mm (P<.001). The coefficient of interrater repeatability was smaller for the Colvard (0.59) than for the Zywave (1.17). The mean difference between the pupillometers for each examiner was 0.17 ± 0.47 mm (P<.01) for examiner 1 and 0.26 ± 0.64 mm (P<.01) for examiner 2. CONCLUSIONS: Scotopic pupil diameter measured with the Zywave was statistically but not clinically significantly smaller than that measured with the Colvard pupillometer. The Zywave produced an inter-rater repeatability comparable to other devices although not as good as the Colvard pupillometer. [J Refract Surg 2004;20:248-252]
- 1 April 2004
- Published by Elsevier in Ophthalmology
- Vol. 111 (4) , 768-774
In vivo confocal microscopic findings in patients with Steroid-Induced glaucoma after LASIK*1
- 1 April 2004
- Published by Elsevier in Ophthalmology
- Vol. 111 (4) , 768-774
In vivo confocal microscopic findings in patients with Steroid-Induced glaucoma after LASIK*1