Francis E. Kennedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francis E. Kennedy has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Keith D. Paulsen
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
5 shared publications - Douglas W. Van Citters
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
3 shared publications - Alex Hartov
Dartmouth College
2 shared publications - David W. Roberts
Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
2 shared publications - John B. Weaver
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
2 shared publications - Michael I. Miga
Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
2 shared publications
Latest Publications
- 21 June 2016
- Published by ASME International in Journal of Tribology
- Vol. 138 (4) , 042101
Modeling Sliding Contact Temperatures, Including Effects of Surface Roughness and Convection
The ability to predict contact surface temperatures in rolling/sliding contacting bodies is important if failure of tribological components is to be avoided. Many works on surface temperature analysis and prediction have been published over the past 75 years or so, but most of the analytical solutions that are readily available do not include such important factors as finite body geometry, surface roughness, or convective cooling. Approaches for addressing these deficiencies are presented in this paper. This paper builds on previous analytical work by the authors and others, and presents models that are based on experimental observations of contact temperatures and factors that affect them. It is shown that the total surface temperature rise above ambient temperature is the sum of nominal temperature rise and flash temperature rise. Models are developed for calculating nominal surface temperature rise for sliding bodies of finite size, including effects of both convection and conduction. Flash temperature models are developed for both single and multiple contacts, as would be found with rough surfaces. Methods are presented that are valid for a variety of geometries and kinematic operating conditions, and techniques are also presented for partitioning the frictional heat between the two contacting surfaces. Examples of the use of the methodology are presented, along with experimental verification of the predictions.
- 21 June 2016
- Published by ASME International in Journal of Tribology
- Vol. 138 (4) , 042101
Modeling Sliding Contact Temperatures, Including Effects of Surface Roughness and Convection
The ability to predict contact surface temperatures in rolling/sliding contacting bodies is important if failure of tribological components is to be avoided. Many works on surface temperature analysis and prediction have been published over the past 75 years or so, but most of the analytical solutions that are readily available do not include such important factors as finite body geometry, surface roughness, or convective cooling. Approaches for addressing these deficiencies are presented in this paper. This paper builds on previous analytical work by the authors and others, and presents models that are based on experimental observations of contact temperatures and factors that affect them. It is shown that the total surface temperature rise above ambient temperature is the sum of nominal temperature rise and flash temperature rise. Models are developed for calculating nominal surface temperature rise for sliding bodies of finite size, including effects of both convection and conduction. Flash temperature models are developed for both single and multiple contacts, as would be found with rough surfaces. Methods are presented that are valid for a variety of geometries and kinematic operating conditions, and techniques are also presented for partitioning the frictional heat between the two contacting surfaces. Examples of the use of the methodology are presented, along with experimental verification of the predictions.
- 1 January 2013
- Published by Elsevier
Contributor contact details
- 1 January 2013
- Published by Springer Nature
- p. 551-556
Contact Temperatures on Coated or Rough Solid Surfaces
- 1 January 2013
- Published by Springer Nature
- p. 551-556
Contact Temperatures on Coated or Rough Solid Surfaces
- 1 January 2013
- Published by Springer Nature
- p. 1405-1410
Frictional Heat Generation, Partitioning, and Dissipation in Dry Tribological Contacts
- 1 January 2013
- Published by Springer Nature
- p. 1405-1410
Frictional Heat Generation, Partitioning, and Dissipation in Dry Tribological Contacts
- 1 January 2013
- Published by Springer Nature
- p. 968-970
Energy Dissipation and Temperature Determination in Lubricated Contacts
- 1 January 2013
- Published by Springer Nature
- p. 968-970
Energy Dissipation and Temperature Determination in Lubricated Contacts
- 1 January 2008
- Published by ASME International
- p. 135-137
Wear of Highly Crystalline Ultra-High Molecular Weight Polyethylene
Highly crystalline ultra-high molecular weight polyethylene (UHMWPE) has historically experienced little success as a bearing material in total joint arthroplasty due to oxidation related fatigue failures. Recent sterilization and treatment advances have reduced or eliminated the risk of oxidation, allowing for a renewed interest in this particular material. The current study investigates the wear resistance of a highly crystalline UHMWPE in comparison to clinically relevant control materials. The highly crystalline material exhibits a wear rate superior to never irradiated material, and similar to irradiated material. The wear rate reduction is attributed to the larger crystallites’ ability to slow subsurface crack growth.
- 1 January 2008
- Published by ASME International
- p. 135-137
Wear of Highly Crystalline Ultra-High Molecular Weight Polyethylene
Highly crystalline ultra-high molecular weight polyethylene (UHMWPE) has historically experienced little success as a bearing material in total joint arthroplasty due to oxidation related fatigue failures. Recent sterilization and treatment advances have reduced or eliminated the risk of oxidation, allowing for a renewed interest in this particular material. The current study investigates the wear resistance of a highly crystalline UHMWPE in comparison to clinically relevant control materials. The highly crystalline material exhibits a wear rate superior to never irradiated material, and similar to irradiated material. The wear rate reduction is attributed to the larger crystallites’ ability to slow subsurface crack growth.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6511, 65111B
3D finite element solution to the dynamic poroelasticity problem for use in MR elastography
Magnetic Resonance Elastography (MRE) has emerged as a noninvasive, quantitative physical means of examining the elastic properties of biological tissues. While it is common to assume simplified elasticity models for purposes of MRE image reconstruction, it is well-accepted that many soft tissues display complex time-dependent behavior not described by linear elasticity. Understanding how the mechanical properties of biological materials change with the frequency of the applied stresses and strains is paramount to the reconstructive imaging techniques used in steady-state MRE. Alternative continuum models, such as consolidation theory, offer the ability to model tissue and other materials comprised of two distinct phases, generally consisting of an elastic solid phase and an infiltrating fluid. For these materials, the time-dependent response under a given load is a function not only of the elastic properties of the solid matrix, but also of the rate at which fluid can flow through the matrix under a pressure gradient. To better study the behavior of the dynamic poroelasticity equations, a three-dimensional finite element model was constructed. Confined, time-harmonic excitation of simulated soil and tissue-like columns was performed to determined material deformation and pore pressure distributions, as well as to identify the influence of the key model parameters under loading conditions and frequencies relevant in steady-state MRE. The results show that the finite element implementation is able to represent the analytical behavior with errors on the order of 1% over a broad range of frequencies. Further, differences between poroelastic and elastic responses in the column can be significant over the frequency range relevant to MRE depending on the value of hydraulic conductivity assumed for the medium.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6511, 65111B
3D finite element solution to the dynamic poroelasticity problem for use in MR elastography
Magnetic Resonance Elastography (MRE) has emerged as a noninvasive, quantitative physical means of examining the elastic properties of biological tissues. While it is common to assume simplified elasticity models for purposes of MRE image reconstruction, it is well-accepted that many soft tissues display complex time-dependent behavior not described by linear elasticity. Understanding how the mechanical properties of biological materials change with the frequency of the applied stresses and strains is paramount to the reconstructive imaging techniques used in steady-state MRE. Alternative continuum models, such as consolidation theory, offer the ability to model tissue and other materials comprised of two distinct phases, generally consisting of an elastic solid phase and an infiltrating fluid. For these materials, the time-dependent response under a given load is a function not only of the elastic properties of the solid matrix, but also of the rate at which fluid can flow through the matrix under a pressure gradient. To better study the behavior of the dynamic poroelasticity equations, a three-dimensional finite element model was constructed. Confined, time-harmonic excitation of simulated soil and tissue-like columns was performed to determined material deformation and pore pressure distributions, as well as to identify the influence of the key model parameters under loading conditions and frequencies relevant in steady-state MRE. The results show that the finite element implementation is able to represent the analytical behavior with errors on the order of 1% over a broad range of frequencies. Further, differences between poroelastic and elastic responses in the column can be significant over the frequency range relevant to MRE depending on the value of hydraulic conductivity assumed for the medium.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6143
MR elastographic methods for the evaluation of plantar fat pads: preliminary comparison of the shear modulus for shearing deformation and compressive deformation in normal subjects
MR elastography (MRE) images the intrinsic mechanical properties of soft tissues; e.g., the shear modulus, μ. The μ of the plantar soft tissues is important in understanding the mechanisms whereby the forces induced during normal motion produce ulcers that lead to amputation in diabetic feet. We compared the compliance of the heel fat pad to compressive forces and to shearing forces. The design of prosthetics to protect the foot depends on the proper understanding of the mechanisms inducing damage. In the heel fat pads of six normal subjects, between 25 and 65 years of age, the μ for deformation perpendicular to the direction of weight bearing is similar but not identical to that determined for deformation along the weight bearing axis. The average difference between μ along the weight bearing axis and μ perpendicular to the weight bearing axis, is well correlated with age (Correlation Coefficient = 0.789). The p-value for the data being random was 0.0347 indicating that the observed difference is not likely to be random. The p-value for control points is 0.8989, indicating a random process. The results are suggestive that the high compressive forces imposed during walking damage the heel fat pads over time resulting in softening to compression preferentially over shearing. It is important to validate the observed effect with larger numbers of subjects, and better controls including measures of activity, and to understand if diseases like diabetes increase the observed damage.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6143
MR elastographic methods for the evaluation of plantar fat pads: preliminary comparison of the shear modulus for shearing deformation and compressive deformation in normal subjects
MR elastography (MRE) images the intrinsic mechanical properties of soft tissues; e.g., the shear modulus, μ. The μ of the plantar soft tissues is important in understanding the mechanisms whereby the forces induced during normal motion produce ulcers that lead to amputation in diabetic feet. We compared the compliance of the heel fat pad to compressive forces and to shearing forces. The design of prosthetics to protect the foot depends on the proper understanding of the mechanisms inducing damage. In the heel fat pads of six normal subjects, between 25 and 65 years of age, the μ for deformation perpendicular to the direction of weight bearing is similar but not identical to that determined for deformation along the weight bearing axis. The average difference between μ along the weight bearing axis and μ perpendicular to the weight bearing axis, is well correlated with age (Correlation Coefficient = 0.789). The p-value for the data being random was 0.0347 indicating that the observed difference is not likely to be random. The p-value for control points is 0.8989, indicating a random process. The results are suggestive that the high compressive forces imposed during walking damage the heel fat pads over time resulting in softening to compression preferentially over shearing. It is important to validate the observed effect with larger numbers of subjects, and better controls including measures of activity, and to understand if diseases like diabetes increase the observed damage.
- 1 January 2006
- Published by ASME International
- p. 1193-1202
Lubrication and Wear of Artificial Knee Joint Materials in a Rolling/Sliding Tribotester
This paper describes the influence of lubrication on wear during testing of materials for artificial knee joints in a rolling/sliding tribotester built to simulate contact conditions in a total knee replacement. The test configuration consists of parallel cylinders (pucks) of ultrahigh molecular weight polyethylene (UHMWPE) and polished cobalt-chrome alloy in oscillatory rolling/sliding contact in a bath of dilute (25%) bovine serum. Wear tests of three different UHMWPE materials were run under constant load at 40% sliding for 1.5 million oscillation cycles at 1.5 cycles/second. Wear of the UHMWPE was determined by measuring the profile of the cylindrical contact surface of the puck before and after each test. Profile measurements were repeated after at least fourteen days to account for creep. Differences between initial and final profiles were attributed to wear of the UHMWPE. It was found that the largest wear depth occurred near the ends of the oscillatory contact area, with the most heavily irradiated material showing the least wear. Analysis of the elastohydrodynamic lubrication in the rolling/sliding contact was carried out assuming a line contact situation. The time dependent modified Reynolds equation and the elasticity equation with initial conditions were solved numerically using a multigrid technique with full approximation scheme, and using a Newton Raphson method to solve the highly nonlinear system of equations. The thickness of the lubricating film of bovine serum was determined for points along the length of the wear track. It was found that the smallest film thickness (hmin ) occurs very close to the location in the oscillating contact where the greatest wear occurs, owing to the very low entraining velocity near the ends of the oscillation cycle. The coefficient for wear of the UHMWPE (K) was found to be relatively constant over the central section of the oscillatory motion, but increased to a higher value where hmin decreased to near zero. Thus, the important influence of lubrication on wear of artificial knee bearings was demonstrated.
- 1 January 2006
- Published by ASME International
- p. 1193-1202
Lubrication and Wear of Artificial Knee Joint Materials in a Rolling/Sliding Tribotester
This paper describes the influence of lubrication on wear during testing of materials for artificial knee joints in a rolling/sliding tribotester built to simulate contact conditions in a total knee replacement. The test configuration consists of parallel cylinders (pucks) of ultrahigh molecular weight polyethylene (UHMWPE) and polished cobalt-chrome alloy in oscillatory rolling/sliding contact in a bath of dilute (25%) bovine serum. Wear tests of three different UHMWPE materials were run under constant load at 40% sliding for 1.5 million oscillation cycles at 1.5 cycles/second. Wear of the UHMWPE was determined by measuring the profile of the cylindrical contact surface of the puck before and after each test. Profile measurements were repeated after at least fourteen days to account for creep. Differences between initial and final profiles were attributed to wear of the UHMWPE. It was found that the largest wear depth occurred near the ends of the oscillatory contact area, with the most heavily irradiated material showing the least wear. Analysis of the elastohydrodynamic lubrication in the rolling/sliding contact was carried out assuming a line contact situation. The time dependent modified Reynolds equation and the elasticity equation with initial conditions were solved numerically using a multigrid technique with full approximation scheme, and using a Newton Raphson method to solve the highly nonlinear system of equations. The thickness of the lubricating film of bovine serum was determined for points along the length of the wear track. It was found that the smallest film thickness (hmin ) occurs very close to the location in the oscillating contact where the greatest wear occurs, owing to the very low entraining velocity near the ends of the oscillation cycle. The coefficient for wear of the UHMWPE (K) was found to be relatively constant over the central section of the oscillatory motion, but increased to a higher value where hmin decreased to near zero. Thus, the important influence of lubrication on wear of artificial knee bearings was demonstrated.