Alex Hartov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex Hartov has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Keith D. Paulsen
Thayer School of Engineering, Dartmouth College
12 shared publications - David W. Roberts
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
7 shared publications - Songbai Ji
Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, USA
3 shared publications - Xiaoyao Fan
Dartmouth College
3 shared publications David Roberts
2 shared publications- Francis E. Kennedy
Dartmouth College
2 shared publications
Latest Publications
- Open Access
Low Cost, High Performance, 16-Channel Microwave Measurement System for Tomographic Applications
We have developed a multichannel software defined radio-based transceiver measurement system for use in general microwave tomographic applications. The unit is compact enough to fit conveniently underneath the current illumination tank of the Dartmouth microwave breast imaging system. The system includes 16 channels that can both transmit and receive and it operates from 500 MHz to 2.5 GHz while measuring signals down to −140 dBm. As is the case with multichannel systems, cross-channel leakage is an important specification and must be lower than the noise floors for each receiver. This design exploits the isolation inherent when the individual receivers for each channel are physically separate; however, these challenging specifications require more involved signal isolation techniques at both the system design level and the individual, shielded component level. We describe the isolation design techniques for the critical system elements and demonstrate specification compliance at both the component and system level.
Open AccessLow Cost, High Performance, 16-Channel Microwave Measurement System for Tomographic Applications
We have developed a multichannel software defined radio-based transceiver measurement system for use in general microwave tomographic applications. The unit is compact enough to fit conveniently underneath the current illumination tank of the Dartmouth microwave breast imaging system. The system includes 16 channels that can both transmit and receive and it operates from 500 MHz to 2.5 GHz while measuring signals down to −140 dBm. As is the case with multichannel systems, cross-channel leakage is an important specification and must be lower than the noise floors for each receiver. This design exploits the isolation inherent when the individual receivers for each channel are physically separate; however, these challenging specifications require more involved signal isolation techniques at both the system design level and the individual, shielded component level. We describe the isolation design techniques for the critical system elements and demonstrate specification compliance at both the component and system level.
- 10 September 2012
- Published by Springer Nature
- p. 169-176
Tracking Cortical Surface Deformation Using Stereovision
- 10 September 2012
- Published by Springer Nature
- p. 169-176
Tracking Cortical Surface Deformation Using Stereovision
- 10 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (8) , 2194-2201
Statistical Estimation of EIT Electrode Contact Impedance Using a Magic Toeplitz Matrix
The goal of this paper is to propose a fast and reliable method of simultaneous estimation of conductivity and electrode contact impedances for a homogeneous 2-D disk. Magic Toeplitz matrix as the Neumann-to-Dirichlet map with finite width electrodes plays the central role in our linear model, called the gapZ model. This model enables testing of various hypotheses using the F-test, such as the uniformity of electrode impedances and their statistical significance. The gapZ model is compared with the finite element approximation, and illustrated and validated with a phantom tank experiment filled with saline. Further, this model was illustrated with the patient breast EIT data to identify bad contact electrodes.
- 10 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (8) , 2194-2201
Statistical Estimation of EIT Electrode Contact Impedance Using a Magic Toeplitz Matrix
The goal of this paper is to propose a fast and reliable method of simultaneous estimation of conductivity and electrode contact impedances for a homogeneous 2-D disk. Magic Toeplitz matrix as the Neumann-to-Dirichlet map with finite width electrodes plays the central role in our linear model, called the gapZ model. This model enables testing of various hypotheses using the F-test, such as the uniformity of electrode impedances and their statistical significance. The gapZ model is compared with the finite element approximation, and illustrated and validated with a phantom tank experiment filled with saline. Further, this model was illustrated with the patient breast EIT data to identify bad contact electrodes.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79640V
Optimizing nonrigid registration performance between volumetric true 3D ultrasound images in image-guided neurosurgery
Compensating for brain shift as surgery progresses is important to ensure sufficient accuracy in patient-to-image registration in the operating room (OR) for reliable neuronavigation. Ultrasound has emerged as an important and practical imaging technique for brain shift compensation either by itself or through computational modeling that estimates whole-brain deformation. Using volumetric true 3D ultrasound (3DUS), it is possible to nonrigidly (e.g., based on B-splines) register two temporally different 3DUS images directly to generate feature displacement maps for data assimilation in the biomechanical model. Because of a large amount of data and number of degrees-of-freedom (DOFs) involved, however, a significant computational cost may be required that can adversely influence the clinical feasibility of the technique for efficiently generating model-updated MR (uMR) in the OR. This paper parametrically investigates three B-splines registration parameters and their influence on the computational cost and registration accuracy: number of grid nodes along each direction, floating image volume down-sampling rate, and number of iterations. A simulated rigid body displacement field was employed as a ground-truth against which the accuracy of displacements generated from the B-splines nonrigid registration was compared. A set of optimal parameters was then determined empirically that result in a registration computational cost of less than 1 min and a sub-millimetric accuracy in displacement measurement. These resulting parameters were further applied to a clinical surgery case to demonstrate their practical use. Our results indicate that the optimal set of parameters result in sufficient accuracy and computational efficiency in model computation, which is important for future application of the overall biomechanical modeling to generate uMR for image-guidance in the OR.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79640V
Optimizing nonrigid registration performance between volumetric true 3D ultrasound images in image-guided neurosurgery
Compensating for brain shift as surgery progresses is important to ensure sufficient accuracy in patient-to-image registration in the operating room (OR) for reliable neuronavigation. Ultrasound has emerged as an important and practical imaging technique for brain shift compensation either by itself or through computational modeling that estimates whole-brain deformation. Using volumetric true 3D ultrasound (3DUS), it is possible to nonrigidly (e.g., based on B-splines) register two temporally different 3DUS images directly to generate feature displacement maps for data assimilation in the biomechanical model. Because of a large amount of data and number of degrees-of-freedom (DOFs) involved, however, a significant computational cost may be required that can adversely influence the clinical feasibility of the technique for efficiently generating model-updated MR (uMR) in the OR. This paper parametrically investigates three B-splines registration parameters and their influence on the computational cost and registration accuracy: number of grid nodes along each direction, floating image volume down-sampling rate, and number of iterations. A simulated rigid body displacement field was employed as a ground-truth against which the accuracy of displacements generated from the B-splines nonrigid registration was compared. A set of optimal parameters was then determined empirically that result in a registration computational cost of less than 1 min and a sub-millimetric accuracy in displacement measurement. These resulting parameters were further applied to a clinical surgery case to demonstrate their practical use. Our results indicate that the optimal set of parameters result in sufficient accuracy and computational efficiency in model computation, which is important for future application of the overall biomechanical modeling to generate uMR for image-guidance in the OR.
- 22 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2121-2130
Adaptive spatial calibration of a 3D ultrasound system
Purpose: The authors present a method devised to calibrate the spatial relationship between a 3D ultrasound scanhead and its tracker completely automatically and reliably. The user interaction is limited to collecting ultrasound data on which the calibration is based.Methods: The method of calibration is based on images of a fixed plane of unknown location with respect to the 3D tracking system. This approach has, for advantage, to eliminate the measurement of the plane location as a source of error. The devised method is sufficiently general and adaptable to calibrate scanheads for 2D images and 3D volume sets using the same approach. The basic algorithm for both types of scanheads is the same and can be run unattended fully automatically once the data are collected. The approach was devised by seeking the simplest and most robust solutions for each of the steps required. These are the identification of the plane intersection within the images or volumes and the optimization method used to compute a calibration transformation matrix. The authors use adaptive algorithms in these two steps to eliminate data that would otherwise prevent the convergence of the procedure, which contributes to the robustness of the method.Results: The authors have run tests amounting to 57 runs of the calibration on two a scanhead that produce 3D imaging volumes, at all the available scales. The authors evaluated the system on two criteria: Robustness and accuracy. The program converged to useful values unattended for every one of the tests (100%). Its accuracy, based on the measured location of a reference plane, was estimated to be for all tests combined.Conclusions: The system presented is robust and allows unattended computations of the calibration parameters required for freehand tracked ultrasound based on either 2D or 3D imaging systems.
- 22 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2121-2130
Adaptive spatial calibration of a 3D ultrasound system
Purpose: The authors present a method devised to calibrate the spatial relationship between a 3D ultrasound scanhead and its tracker completely automatically and reliably. The user interaction is limited to collecting ultrasound data on which the calibration is based.Methods: The method of calibration is based on images of a fixed plane of unknown location with respect to the 3D tracking system. This approach has, for advantage, to eliminate the measurement of the plane location as a source of error. The devised method is sufficiently general and adaptable to calibrate scanheads for 2D images and 3D volume sets using the same approach. The basic algorithm for both types of scanheads is the same and can be run unattended fully automatically once the data are collected. The approach was devised by seeking the simplest and most robust solutions for each of the steps required. These are the identification of the plane intersection within the images or volumes and the optimization method used to compute a calibration transformation matrix. The authors use adaptive algorithms in these two steps to eliminate data that would otherwise prevent the convergence of the procedure, which contributes to the robustness of the method.Results: The authors have run tests amounting to 57 runs of the calibration on two a scanhead that produce 3D imaging volumes, at all the available scales. The authors evaluated the system on two criteria: Robustness and accuracy. The program converged to useful values unattended for every one of the tests (100%). Its accuracy, based on the measured location of a reference plane, was estimated to be for all tests combined.Conclusions: The system presented is robust and allows unattended computations of the calibration parameters required for freehand tracked ultrasound based on either 2D or 3D imaging systems.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7625, 762536
An integrated model-based neurosurgical guidance system
Maximal tumor resection without damaging healthy tissue in open cranial surgeries is critical to the prognosis for patients with brain cancers. Preoperative images (e.g., preoperative magnetic resonance images (pMR)) are typically used for surgical planning as well as for intraoperative image-guidance. However, brain shift even at the start of surgery significantly compromises the accuracy of neuronavigation, if the deformation is not compensated for. Compensating for brain shift during surgical operation is, therefore, critical for improving the accuracy of image-guidance and ultimately, the accuracy of surgery. To this end, we have developed an integrated neurosurgical guidance system that incorporates intraoperative three-dimensional (3D) tracking, acquisition of volumetric true 3D ultrasound (iUS), stereovision (iSV) and computational modeling to efficiently generate model-updated MR image volumes for neurosurgical guidance. The system is implemented with real-time Labview to provide high efficiency in data acquisition as well as with Matlab to offer computational convenience in data processing and development of graphical user interfaces related to computational modeling. In a typical patient case, the patient in the operating room (OR) is first registered to pMR image volume. Sparse displacement data extracted from coregistered intraoperative US and/or stereovision images are employed to guide a computational model that is based on consolidation theory. Computed whole-brain deformation is then used to generate a model-updated MR image volume for subsequent surgical guidance. In this paper, we present the key modular components of our integrated, model-based neurosurgical guidance system.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7625, 762536
An integrated model-based neurosurgical guidance system
Maximal tumor resection without damaging healthy tissue in open cranial surgeries is critical to the prognosis for patients with brain cancers. Preoperative images (e.g., preoperative magnetic resonance images (pMR)) are typically used for surgical planning as well as for intraoperative image-guidance. However, brain shift even at the start of surgery significantly compromises the accuracy of neuronavigation, if the deformation is not compensated for. Compensating for brain shift during surgical operation is, therefore, critical for improving the accuracy of image-guidance and ultimately, the accuracy of surgery. To this end, we have developed an integrated neurosurgical guidance system that incorporates intraoperative three-dimensional (3D) tracking, acquisition of volumetric true 3D ultrasound (iUS), stereovision (iSV) and computational modeling to efficiently generate model-updated MR image volumes for neurosurgical guidance. The system is implemented with real-time Labview to provide high efficiency in data acquisition as well as with Matlab to offer computational convenience in data processing and development of graphical user interfaces related to computational modeling. In a typical patient case, the patient in the operating room (OR) is first registered to pMR image volume. Sparse displacement data extracted from coregistered intraoperative US and/or stereovision images are employed to guide a computational model that is based on consolidation theory. Computed whole-brain deformation is then used to generate a model-updated MR image volume for subsequent surgical guidance. In this paper, we present the key modular components of our integrated, model-based neurosurgical guidance system.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7164
Brain tumor resection guided by fluorescence imaging
We present the methods that are being used in the scope of an on-going clinical trial designed to assess the usefulness of ALA-PpIX fluorescence imaging when used in conjunction with pre-operative MRI. The overall objective is to develop imaging-based neuronavigation approaches to aid in maximizing the completeness of brain tumor resection, thereby improving patient survival rate. In this paper we present the imaging methods that are used, emphasizing technical aspects relating to the fluorescence optical microscope, including initial validation approaches based on phantom and small-animal experiments. The surgical workflow is then described in detail based on a high-grade glioma resection we performed.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7164
Brain tumor resection guided by fluorescence imaging
We present the methods that are being used in the scope of an on-going clinical trial designed to assess the usefulness of ALA-PpIX fluorescence imaging when used in conjunction with pre-operative MRI. The overall objective is to develop imaging-based neuronavigation approaches to aid in maximizing the completeness of brain tumor resection, thereby improving patient survival rate. In this paper we present the imaging methods that are used, emphasizing technical aspects relating to the fluorescence optical microscope, including initial validation approaches based on phantom and small-animal experiments. The surgical workflow is then described in detail based on a high-grade glioma resection we performed.
- 1 March 2008
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 62 (3) , 91-101
A COMPARATIVE ANALYSIS OF COREGISTERED ULTRASOUND AND MAGNETIC RESONANCE IMAGING IN NEUROSURGERY
This work presents qualitative and quantitative side-by-side comparisons of oblique coregistered magnetic resonance imaging (MRI) scans and ultrasound images obtained during 35 neurosurgical procedures. Spatially registered series of ultrasound images were recorded for subsequent off-line evaluation and comparison with corresponding preoperative MRI studies. The degree of misalignment was reduced by reregistering the target volume directly with segmented features. The initial apparent spatial misalignment of the target volume after craniotomy ranged from 0.11 to 8.73 mm (mean, 4.01 mm). After reregistration, the mutual information in overlapping segmented features was increased, presumably evidence of a better alignment locally. Additionally, the degree of feature congruence, which was assessed quantitatively through a convex hull approximation, demonstrated that the ultrasound volume was consistently smaller than its MRI counterpart. Although intraoperative ultrasound tends to be difficult to interpret by itself, when accurately coregistered with preoperative MRI scans, its potential utility as a navigational guide is enhanced.
- 1 March 2008
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 62 (3) , 91-101
A COMPARATIVE ANALYSIS OF COREGISTERED ULTRASOUND AND MAGNETIC RESONANCE IMAGING IN NEUROSURGERY
This work presents qualitative and quantitative side-by-side comparisons of oblique coregistered magnetic resonance imaging (MRI) scans and ultrasound images obtained during 35 neurosurgical procedures. Spatially registered series of ultrasound images were recorded for subsequent off-line evaluation and comparison with corresponding preoperative MRI studies. The degree of misalignment was reduced by reregistering the target volume directly with segmented features. The initial apparent spatial misalignment of the target volume after craniotomy ranged from 0.11 to 8.73 mm (mean, 4.01 mm). After reregistration, the mutual information in overlapping segmented features was increased, presumably evidence of a better alignment locally. Additionally, the degree of feature congruence, which was assessed quantitatively through a convex hull approximation, demonstrated that the ultrasound volume was consistently smaller than its MRI counterpart. Although intraoperative ultrasound tends to be difficult to interpret by itself, when accurately coregistered with preoperative MRI scans, its potential utility as a navigational guide is enhanced.
- 30 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5029, 210-222
Graphical user interface for intraoperative neuroimage updating
Image-guided neurosurgery typically relies on preoperative imaging information that is subject to errors resulting from brain shift and deformation in the OR. A graphical user interface (GUI) has been developed to facilitate the flow of data from OR to image volume in order to provide the neurosurgeon with updated views concurrent with surgery. Upon acquisition of registration data for patient position in the OR (using fiducial markers), the Matlab GUI displays ultrasound image overlays on patient specific, preoperative MR images. Registration matrices are also applied to patient-specific anatomical models used for image updating. After displaying the re-oriented brain model in OR coordinates and digitizing the edge of the craniotomy, gravitational sagging of the brain is simulated using the finite element method. Based on this model, interpolation to the resolution of the preoperative images is performed and re-displayed to the surgeon during the procedure. These steps were completed within reasonable time limits and the interface was relatively easy to use after a brief training period. The techniques described have been developed and used retrospectively prior to this study. Based on the work described here, these steps can now be accomplished in the operating room and provide near real-time feedback to the surgeon.
- 30 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5029, 210-222
Graphical user interface for intraoperative neuroimage updating
Image-guided neurosurgery typically relies on preoperative imaging information that is subject to errors resulting from brain shift and deformation in the OR. A graphical user interface (GUI) has been developed to facilitate the flow of data from OR to image volume in order to provide the neurosurgeon with updated views concurrent with surgery. Upon acquisition of registration data for patient position in the OR (using fiducial markers), the Matlab GUI displays ultrasound image overlays on patient specific, preoperative MR images. Registration matrices are also applied to patient-specific anatomical models used for image updating. After displaying the re-oriented brain model in OR coordinates and digitizing the edge of the craniotomy, gravitational sagging of the brain is simulated using the finite element method. Based on this model, interpolation to the resolution of the preoperative images is performed and re-displayed to the surgeon during the procedure. These steps were completed within reasonable time limits and the interface was relatively easy to use after a brief training period. The techniques described have been developed and used retrospectively prior to this study. Based on the work described here, these steps can now be accomplished in the operating room and provide near real-time feedback to the surgeon.
- 30 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5029, 183-192
Using cortical vessels for patient registration during image-guided neurosurgery: a phantom study
Patient registration, a key step in establishing image guidance, has to be performed in real-time after the patient is anesthetized in the operating room (OR) prior to surgery. We propose to use cortical vessels as landmarks for registering the preoperative images to the operating space. To accomplish this, we have attached a video camera to the optics of the operating microscope and acquired a pair of images by moving the scope. The stereo imaging system is calibrated to obtain both intrinsic and extrinsic camera parameters. During neurosurgery, right after opening of dura, a pair of stereo images is acquired. The 3-D locations of blood vessels are estimated via stereo vision techniques. The same series of vessels are localized in the preoperative image volume. From these 3-D coordinates, the transformation matrix between preoperative images and the operating space is estimated. Using a phantom, we have demonstrated that patient registration from cortical vessels is not only feasible but also more accurate than using conventional scalp-attached fiducials. The Fiducial Registration Error (FRE) has been reduced from 1 mm using implanted fiducials to 0.3 mm using cortical vessels. By replacing implanted fiducials with cortical features, we can automate the registration procedure and reduce invasiveness to the patient.
- 30 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5029, 183-192
Using cortical vessels for patient registration during image-guided neurosurgery: a phantom study
Patient registration, a key step in establishing image guidance, has to be performed in real-time after the patient is anesthetized in the operating room (OR) prior to surgery. We propose to use cortical vessels as landmarks for registering the preoperative images to the operating space. To accomplish this, we have attached a video camera to the optics of the operating microscope and acquired a pair of images by moving the scope. The stereo imaging system is calibrated to obtain both intrinsic and extrinsic camera parameters. During neurosurgery, right after opening of dura, a pair of stereo images is acquired. The 3-D locations of blood vessels are estimated via stereo vision techniques. The same series of vessels are localized in the preoperative image volume. From these 3-D coordinates, the transformation matrix between preoperative images and the operating space is estimated. Using a phantom, we have demonstrated that patient registration from cortical vessels is not only feasible but also more accurate than using conventional scalp-attached fiducials. The Fiducial Registration Error (FRE) has been reduced from 1 mm using implanted fiducials to 0.3 mm using cortical vessels. By replacing implanted fiducials with cortical features, we can automate the registration procedure and reduce invasiveness to the patient.