Kenichi Yamazaki
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenichi Yamazaki has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Nishikawa
Shibaura Institute of Technology, 3-7-5 Toyosu, Koto-ku, Tokyo 135-8548, Japan
4 shared publications Keizo Kato
Fundamentals and Materials Society, The Institute of Electrical Engineers of Japan Board of Society
4 shared publicationsToshiki Nakano
Fundamentals and Materials Society, The Institute of Electrical Engineers of Japan Board of Society
4 shared publications- Akimasa Hirata
Nagoya Institute of Technology
3 shared publications - Ilkka Laakso
Aalto University
2 shared publications - Yoichi Sekiba
Power System Analysis Group, Denryoku Computing Center (DCC) Komae Japan
2 shared publications
Latest Publications
- Open Access
- 1 August 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 143 (8) , L8_1
IEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 August 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 143 (8) , L8_1
Open AccessIEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 18 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 38739-38752
Intercomparison of the Averaged Induced Electric Field in Learning-Based Human Head Models Exposed to Low-Frequency Magnetic Fields
Anatomical human models have been widely used in the assessment of induced field strength for low-frequency (LF) electromagnetic field exposure. One bottleneck is the assignment of a single electrical conductivity to all the voxels of the corresponding tissue. This simplification is known to cause computational artifact; therefore, a large reduction factor was considered in international guidelines and standards. Recently, head models with nonuniform conductivities generated using deep learning networks were proposed, and the effect on the reduction of staircasing artifacts was demonstrated. If the effectiveness of the models is confirmed for different models and codes, it would be useful to derive the relationship between the internal and external field strengths needed for setting the exposure limit. The Subcommittee 6 of the IEEE International Committee on Electromagnetic Safety Technical Committee 95 launched a working group to conduct the first intercomparison study of the induced electric field in learning-based head models exposed to LF magnetic fields. Seven international research groups have cooperated in this joint study. The highest relative difference (RD) in averaged electric fields was 23%, which is attributable to the difference caused the by scalar potential finite difference (SPFD) method and finite element method. Except for one group, the RDs in the 100 th and 99 th percentile values of the averaged electric field using the SPFD method with different solvers and codes were below 1%, indicating that the uncertainty due to different codes is sufficiently small under the same exposure scenarios. The findings would be informative for future revision of exposure limits and reduction factors in the exposure standard, which is closely related to computational uncertainty.
- 18 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 38739-38752
Open AccessIntercomparison of the Averaged Induced Electric Field in Learning-Based Human Head Models Exposed to Low-Frequency Magnetic Fields
Anatomical human models have been widely used in the assessment of induced field strength for low-frequency (LF) electromagnetic field exposure. One bottleneck is the assignment of a single electrical conductivity to all the voxels of the corresponding tissue. This simplification is known to cause computational artifact; therefore, a large reduction factor was considered in international guidelines and standards. Recently, head models with nonuniform conductivities generated using deep learning networks were proposed, and the effect on the reduction of staircasing artifacts was demonstrated. If the effectiveness of the models is confirmed for different models and codes, it would be useful to derive the relationship between the internal and external field strengths needed for setting the exposure limit. The Subcommittee 6 of the IEEE International Committee on Electromagnetic Safety Technical Committee 95 launched a working group to conduct the first intercomparison study of the induced electric field in learning-based head models exposed to LF magnetic fields. Seven international research groups have cooperated in this joint study. The highest relative difference (RD) in averaged electric fields was 23%, which is attributable to the difference caused the by scalar potential finite difference (SPFD) method and finite element method. Except for one group, the RDs in the 100 th and 99 th percentile values of the averaged electric field using the SPFD method with different solvers and codes were below 1%, indicating that the uncertainty due to different codes is sufficiently small under the same exposure scenarios. The findings would be informative for future revision of exposure limits and reduction factors in the exposure standard, which is closely related to computational uncertainty.
- Open Access
- 1 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 95455-95466
Calculation of Electric Field Induced in the Human Body for Simultaneous Exposure to Spatially Uniform ELF Electric and Magnetic Fields With a Phase Difference
- 1 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 95455-95466
Open AccessCalculation of Electric Field Induced in the Human Body for Simultaneous Exposure to Spatially Uniform ELF Electric and Magnetic Fields With a Phase Difference
- Open Access
- 1 November 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (11) , L11_1
IEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 November 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (11) , L11_1
Open AccessIEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 1 October 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (10) , L10_1
IEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 October 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (10) , L10_1
Open AccessIEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 1 September 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (9) , L9_1
IEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 September 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (9) , L9_1
Open AccessIEEJ Fundamentals and Materials Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (6) , 1812-1819
Calculation of Internal Electric Fields Induced by Power Frequency Magnetic Fields During Live-Line Working Using Human Models With Realistic Postures
Worker exposure to high-intensity magnetic fields encountered during bare-handed live-line working on a conductor of an overhead transmission line is a major safety concern. In this article, internal (in situ) electric fields in a live-line worker induced by power frequency magnetic fields were numerically calculated considering realistic exposure conditions, i.e., different working postures on a conductor bundle of an overhead transmission line. The scalar potential finite difference (SPFD) method was adopted to voxel-based human models with realistic postures to calculate internal electric fields inside the models. The results showed that the internal electric fields were far below the basic restriction for occupational exposure stipulated in the International Commission on Nonionizing Radiation Protection guidelines even when the maximum magnetic field exceeded the reference level in the guidelines.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (6) , 1812-1819
Calculation of Internal Electric Fields Induced by Power Frequency Magnetic Fields During Live-Line Working Using Human Models With Realistic Postures
Worker exposure to high-intensity magnetic fields encountered during bare-handed live-line working on a conductor of an overhead transmission line is a major safety concern. In this article, internal (in situ) electric fields in a live-line worker induced by power frequency magnetic fields were numerically calculated considering realistic exposure conditions, i.e., different working postures on a conductor bundle of an overhead transmission line. The scalar potential finite difference (SPFD) method was adopted to voxel-based human models with realistic postures to calculate internal electric fields inside the models. The results showed that the internal electric fields were far below the basic restriction for occupational exposure stipulated in the International Commission on Nonionizing Radiation Protection guidelines even when the maximum magnetic field exceeded the reference level in the guidelines.
- 18 February 2020
- Published by Wiley in Electronics and Communications in Japan
- Vol. 103 (1-4) , 10-18
Assessment methods for electric and magnetic fields in low and intermediate frequencies related to human exposures and the status of their standardization
Protection of human from exposures to electric and magnetic fields has received public concerns for decades. Methods to assess physical quantities related to the exposure, such as artificially generated electric and magnetic fields, electric fields inside human body caused by the exposures, and contact currents, have been investigated and established in relation to compliance assessment against exposure guidelines. In addition, some of the methods have been standardized internationally to facilitate mutual authentication by standard methods. This article reviews the methods to assess the human exposure to electric and magnetic fields, mainly focusing of low and intermediate frequencies (approximately below 100 kHz), and the status of their standardization.
- 18 February 2020
- Published by Wiley in Electronics and Communications in Japan
- Vol. 103 (1-4) , 10-18
Assessment methods for electric and magnetic fields in low and intermediate frequencies related to human exposures and the status of their standardization
Protection of human from exposures to electric and magnetic fields has received public concerns for decades. Methods to assess physical quantities related to the exposure, such as artificially generated electric and magnetic fields, electric fields inside human body caused by the exposures, and contact currents, have been investigated and established in relation to compliance assessment against exposure guidelines. In addition, some of the methods have been standardized internationally to facilitate mutual authentication by standard methods. This article reviews the methods to assess the human exposure to electric and magnetic fields, mainly focusing of low and intermediate frequencies (approximately below 100 kHz), and the status of their standardization.
- 15 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (3) , 589-597
Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field
An in situ (internal) electric field is used as a dosimetric quantity for human protection from low-frequency electromagnetic fields (lower than 5 MHz) under international safety standard/guidelines. The IEEE standard uses a homogenous elliptical cross section to derive external field strength corresponding to an in situ field strength, while the International Committee on Non-Ionizing Radiation Protection (ICNIRP) guidelines use anatomical models to relate them. In the latter, “the 99th percentile value of the in situ electric field averaged over the cube of its side length of 2 mm” is used to represent the maximum in situ electric field. This metric was introduced to suppress computational artifacts that are inherent when using voxelized anatomical models, in which curved boundaries are discretized with a stair-casing approximation. To suppress the error, a few schemes have been proposed for treating the computational artifacts. In this study, the various schemes to suppress the artifacts are reviewed. Subsequently, a postprocessing method for determining the appropriate maximum in situ field strength is proposed. The performance of the proposed scheme is first verified by comparison with an analytical solution in a multilayered sphere. The method is then applied for different exposure scenarios in anatomically realistic human models where the volume under computation is also considered.
- 15 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (3) , 589-597
Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field
An in situ (internal) electric field is used as a dosimetric quantity for human protection from low-frequency electromagnetic fields (lower than 5 MHz) under international safety standard/guidelines. The IEEE standard uses a homogenous elliptical cross section to derive external field strength corresponding to an in situ field strength, while the International Committee on Non-Ionizing Radiation Protection (ICNIRP) guidelines use anatomical models to relate them. In the latter, “the 99th percentile value of the in situ electric field averaged over the cube of its side length of 2 mm” is used to represent the maximum in situ electric field. This metric was introduced to suppress computational artifacts that are inherent when using voxelized anatomical models, in which curved boundaries are discretized with a stair-casing approximation. To suppress the error, a few schemes have been proposed for treating the computational artifacts. In this study, the various schemes to suppress the artifacts are reviewed. Subsequently, a postprocessing method for determining the appropriate maximum in situ field strength is proposed. The performance of the proposed scheme is first verified by comparison with an analytical solution in a multilayered sphere. The method is then applied for different exposure scenarios in anatomically realistic human models where the volume under computation is also considered.
- Open Access
- 21 August 2006
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 1 (2) , 131-139
A review of studies on the electric field and the current induced in a human body exposed to electromagnetic fields
- 21 August 2006
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 1 (2) , 131-139
Open AccessA review of studies on the electric field and the current induced in a human body exposed to electromagnetic fields