Jay A. Johannigman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jay A. Johannigman has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Kenneth Davis
6 shared publicationsRichard D. Branson
5 shared publicationsPeter Muskat
3 shared publications- Richard D. Branson
University of Cincinnati
3 shared publications - Stephen L. Barnes
University of Missouri
3 shared publications Daniel Cox
University of Cincinnati College of Medicine, Office of the Command Surgeon, Air Mobility Command
2 shared publications
Latest Publications
- 26 May 2018
- Published by Springer Nature
- p. 45-61
En Route Care
- 22 July 2017
- Published by Springer Nature
- p. 611-629
Monitoring
- 1 October 2015
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 79 (4) , S216-S220
Hypoxemia during aeromedical evacuation of the walking wounded
BACKGROUND Hypobaric hypoxemia is a well-known risk of aeromedical evacuation (AE). Validating patients as safe to fly includes assessment of oxygenation status as well as oxygen-carrying capability (hemoglobin). The incidence and severity of hypoxemia during AE of noncritically injured casualties have not been studied. METHODS Subjects deemed safe to fly by the validating flight surgeon were monitored with pulse oximetry from the flight line until arrival at definitive care. All subjects were US military personnel or contractors following traumatic injuries. Noninvasive oxygen saturation (SpO2), pulse rate, and noninvasive hemoglobin were measured every 5 seconds and recorded to electronic memory. Patient demographics and physiologic data were collected by chart abstraction from the Air Force Form 3899, patient movement record. The incidence and duration of hypoxemic events (SpO2 < 90%) and critical hypoxemic events were determined (SpO2 < 85%). RESULTS Sixty-one casualties were evaluated during AE from Bagram Air Base to Landstuhl Regional Medical Center. The mean (SD) age was 26.2 (6) years, Injury Severity Score (ISS) was 8 (11), and mean SpO2 before AE was 96% (2%). The mean (SD) transport time was 9.3 (1.3) hours. Patients were monitored before AE for a brief period, yielding a total recording time of 10.28 hours. The mean (SD) hemoglobin at the time of enrollment was 13.2 (3.5) g/dL (9.4–18.0 g/dL). Hypoxemia (SpO2 < 90%) was seen in 55 (90%) of 61 subjects. The mean duration of SpO2 less than 90% was 44 minutes. The mean (SD) change in SpO2 from baseline to mean in-flight SpO2 was 4% (1.2%). Thirty-four patients (56%) exhibited an SpO2 less than 85% for 11.7 (15) minutes. CONCLUSION Hypoxemia is a common event during AE of casualties. In patients with infection and concussion or mild traumatic brain injury, this could have long-term consequences. LEVEL OF EVIDENCE Epidemiologic/prognostic study, level V.
- 1 October 2015
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 79 (4) , S216-S220
Hypoxemia during aeromedical evacuation of the walking wounded
BACKGROUND Hypobaric hypoxemia is a well-known risk of aeromedical evacuation (AE). Validating patients as safe to fly includes assessment of oxygenation status as well as oxygen-carrying capability (hemoglobin). The incidence and severity of hypoxemia during AE of noncritically injured casualties have not been studied. METHODS Subjects deemed safe to fly by the validating flight surgeon were monitored with pulse oximetry from the flight line until arrival at definitive care. All subjects were US military personnel or contractors following traumatic injuries. Noninvasive oxygen saturation (SpO2), pulse rate, and noninvasive hemoglobin were measured every 5 seconds and recorded to electronic memory. Patient demographics and physiologic data were collected by chart abstraction from the Air Force Form 3899, patient movement record. The incidence and duration of hypoxemic events (SpO2 < 90%) and critical hypoxemic events were determined (SpO2 < 85%). RESULTS Sixty-one casualties were evaluated during AE from Bagram Air Base to Landstuhl Regional Medical Center. The mean (SD) age was 26.2 (6) years, Injury Severity Score (ISS) was 8 (11), and mean SpO2 before AE was 96% (2%). The mean (SD) transport time was 9.3 (1.3) hours. Patients were monitored before AE for a brief period, yielding a total recording time of 10.28 hours. The mean (SD) hemoglobin at the time of enrollment was 13.2 (3.5) g/dL (9.4–18.0 g/dL). Hypoxemia (SpO2 < 90%) was seen in 55 (90%) of 61 subjects. The mean duration of SpO2 less than 90% was 44 minutes. The mean (SD) change in SpO2 from baseline to mean in-flight SpO2 was 4% (1.2%). Thirty-four patients (56%) exhibited an SpO2 less than 85% for 11.7 (15) minutes. CONCLUSION Hypoxemia is a common event during AE of casualties. In patients with infection and concussion or mild traumatic brain injury, this could have long-term consequences. LEVEL OF EVIDENCE Epidemiologic/prognostic study, level V.
- Open Access
- 10 December 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (6) , R200
Pharmacokinetics and lung delivery of PDDS-aerosolized amikacin (NKTR-061) in intubated and mechanically ventilated patients with nosocomial pneumonia
Introduction: Aminoglycosides aerosolization might achieve better diffusion into the alveolar compartment than intravenous use. The objective of this multicenter study was to evaluate aerosol-delivered amikacin penetration into the alveolar epithelial lining fluid (ELF) using a new vibrating mesh nebulizer (Pulmonary Drug Delivery System (PDDS), Nektar Therapeutics), which delivers high doses to the lungs. Methods: Nebulized amikacin (400 mg bid) was delivered to the lungs of 28 mechanically ventilated patients with Gram-negative VAP for 7-14 days, adjunctive to intravenous therapy. On treatment day 3, 30 minutes after completing aerosol delivery, all the patients underwent bronchoalveolar lavage in the infection-involved area and the ELF amikacin concentration was determined. The same day, urine and serum amikacin concentrations were determined at different time points. Results: Median (range) ELF amikacin and maximum serum amikacin concentrations were 976.1 (135.7-16127.6) and 0.9 (0.62-1.73) μg/mL, respectively. The median total amount of amikacin excreted in urine during the first and second 12-hour collection on day 3 were 19 (12.21-28) and 21.2 (14.1-29.98) μg, respectively. During the study period, daily through amikacin measurements were below the level of nephrotoxicity. Sixty-four unexpected adverse events were reported, among which 2 were deemed possibly due to nebulized amikacin: one episode of worsening renal failure, and one episode of bronchospasm. Conclusions: PDDS delivery of aerosolized amikacin achieved very high aminoglycoside concentrations in ELF from radiography-controlled infection-involved zones, while maintaining safe serum amikacin concentrations. The ELF concentrations always exceeded the amikacin minimum inhibitory concentrations for Gram-negative microorganisms usually responsible for these pneumonias. The clinical impact of amikacin delivery with this system remains to be determined. Trial Registration: ClinicalTrials.gov Identifier: NCT01021436.
- 10 December 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (6) , R200
Open AccessPharmacokinetics and lung delivery of PDDS-aerosolized amikacin (NKTR-061) in intubated and mechanically ventilated patients with nosocomial pneumonia
Introduction: Aminoglycosides aerosolization might achieve better diffusion into the alveolar compartment than intravenous use. The objective of this multicenter study was to evaluate aerosol-delivered amikacin penetration into the alveolar epithelial lining fluid (ELF) using a new vibrating mesh nebulizer (Pulmonary Drug Delivery System (PDDS), Nektar Therapeutics), which delivers high doses to the lungs. Methods: Nebulized amikacin (400 mg bid) was delivered to the lungs of 28 mechanically ventilated patients with Gram-negative VAP for 7-14 days, adjunctive to intravenous therapy. On treatment day 3, 30 minutes after completing aerosol delivery, all the patients underwent bronchoalveolar lavage in the infection-involved area and the ELF amikacin concentration was determined. The same day, urine and serum amikacin concentrations were determined at different time points. Results: Median (range) ELF amikacin and maximum serum amikacin concentrations were 976.1 (135.7-16127.6) and 0.9 (0.62-1.73) μg/mL, respectively. The median total amount of amikacin excreted in urine during the first and second 12-hour collection on day 3 were 19 (12.21-28) and 21.2 (14.1-29.98) μg, respectively. During the study period, daily through amikacin measurements were below the level of nephrotoxicity. Sixty-four unexpected adverse events were reported, among which 2 were deemed possibly due to nebulized amikacin: one episode of worsening renal failure, and one episode of bronchospasm. Conclusions: PDDS delivery of aerosolized amikacin achieved very high aminoglycoside concentrations in ELF from radiography-controlled infection-involved zones, while maintaining safe serum amikacin concentrations. The ELF concentrations always exceeded the amikacin minimum inhibitory concentrations for Gram-negative microorganisms usually responsible for these pneumonias. The clinical impact of amikacin delivery with this system remains to be determined. Trial Registration: ClinicalTrials.gov Identifier: NCT01021436.
- Retracted
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 208 (5) , 763-768
RETRACTED: Closed Loop Control of Inspired Oxygen Concentration in Trauma Patients
Transport of mechanically ventilated patients in a combat zone presents challenges, including conservation of resources. In the battlefield setting, provision of oxygen supplies remains an important issue. Autonomous control of oxygen concentration can allow a reduction in oxygen usage and reduced mission weight. Trauma patients requiring ventilation and inspired oxygen concentration (FIO(2)) > 0.40 were evaluated for study. Patients were randomized to consecutive 4-hour periods of closed loop control or standard care. The system for autonomous control consisted of a ventilator, oximeter, and a portable computer. The computer housed the control algorithm and collected data every 5 seconds. The controller goal was to maintain pulse oximetry (SpO(2)) at 94 +/- 2% through discrete changes of 1% to 5% every 30 seconds. Ventilator settings and SpO(2) were recorded every 5 seconds for analysis. Forty-five patients were enrolled in this study. Oxygen saturation was maintained in the 92% to 96% saturation range 33 +/- 36% of the time during clinician control versus 83 +/- 21% during closed loop control. Time spent at the target SpO(2) 92% to 96% was 193.3 +/- 59.18 minutes during closed loop control and 87.08 +/- 87.95 minutes during clinician control (p < 0.001). Hyperoxemia was more frequent during clinician control (144.29 +/- 90.09 minutes) than during closed loop control (38.91 +/- 55.86 minutes; p < 0.001). There were no differences in the number of episodes of SpO(2) < 88%. Oxygen usage was reduced by 32% during closed loop control. Closed loop control of FIO(2) offers the opportunity for maximizing oxygen resources, reducing mission weight, and providing targeted normoxemia without increasing risk of hypoxemia in ventilated trauma patients.
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 208 (5) , 763-768
RetractedRETRACTED: Closed Loop Control of Inspired Oxygen Concentration in Trauma Patients
Transport of mechanically ventilated patients in a combat zone presents challenges, including conservation of resources. In the battlefield setting, provision of oxygen supplies remains an important issue. Autonomous control of oxygen concentration can allow a reduction in oxygen usage and reduced mission weight. Trauma patients requiring ventilation and inspired oxygen concentration (FIO(2)) > 0.40 were evaluated for study. Patients were randomized to consecutive 4-hour periods of closed loop control or standard care. The system for autonomous control consisted of a ventilator, oximeter, and a portable computer. The computer housed the control algorithm and collected data every 5 seconds. The controller goal was to maintain pulse oximetry (SpO(2)) at 94 +/- 2% through discrete changes of 1% to 5% every 30 seconds. Ventilator settings and SpO(2) were recorded every 5 seconds for analysis. Forty-five patients were enrolled in this study. Oxygen saturation was maintained in the 92% to 96% saturation range 33 +/- 36% of the time during clinician control versus 83 +/- 21% during closed loop control. Time spent at the target SpO(2) 92% to 96% was 193.3 +/- 59.18 minutes during closed loop control and 87.08 +/- 87.95 minutes during clinician control (p < 0.001). Hyperoxemia was more frequent during clinician control (144.29 +/- 90.09 minutes) than during closed loop control (38.91 +/- 55.86 minutes; p < 0.001). There were no differences in the number of episodes of SpO(2) < 88%. Oxygen usage was reduced by 32% during closed loop control. Closed loop control of FIO(2) offers the opportunity for maximizing oxygen resources, reducing mission weight, and providing targeted normoxemia without increasing risk of hypoxemia in ventilated trauma patients.
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S302-S320
Autonomous Control of Ventilation
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S302-S320
Autonomous Control of Ventilation
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S295-S301
Autonomous Control of Oxygenation
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S295-S301
Autonomous Control of Oxygenation
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S287-S288
Introduction
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (4) , S287-S288
Introduction
- 1 July 2007
- Vol. 14 (1) , P35-8
Closed loop control of oxgenation and ventilation.
Closed loop control of oxygenation and ventilation during mechanical ventilatory support is essential for remote medical care in an austere environment. Closed loop control allows for expert systems to provide the current standard of care in the absence of on-site expertise. Ventilation may be controlled by simple systems incorporating patient height or by advanced systems incorporating measurements of end-tidal carbon dioxide (ETCO2) and pulmonary impedance. Oxygenation may be controlled by adjustments of inspired oxygen concentrations (FIO2) and positive end-expiratory pressure (PEEP) using pulse oximetry (SpO2) as the input. Control of oxygenation can prevent hypoxemia and has the potential to reduce oxygen requirements. A double closed loop system of oxygenation control including control of FIO2 via SpO2 and control of oxygen generation by a portable oxygen generator (POG) based on FIO2 and minute ventilation (VE) promises safety and efficiency. Remote control of ventilation and oxygenation is possible using existing technology.
- 1 July 2007
- Vol. 14 (1) , P35-8
Closed loop control of oxgenation and ventilation.
Closed loop control of oxygenation and ventilation during mechanical ventilatory support is essential for remote medical care in an austere environment. Closed loop control allows for expert systems to provide the current standard of care in the absence of on-site expertise. Ventilation may be controlled by simple systems incorporating patient height or by advanced systems incorporating measurements of end-tidal carbon dioxide (ETCO2) and pulmonary impedance. Oxygenation may be controlled by adjustments of inspired oxygen concentrations (FIO2) and positive end-expiratory pressure (PEEP) using pulse oximetry (SpO2) as the input. Control of oxygenation can prevent hypoxemia and has the potential to reduce oxygen requirements. A double closed loop system of oxygenation control including control of FIO2 via SpO2 and control of oxygen generation by a portable oxygen generator (POG) based on FIO2 and minute ventilation (VE) promises safety and efficiency. Remote control of ventilation and oxygenation is possible using existing technology.
- 1 June 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 62 (6) , S35
Critical Care Aeromedical Teams (Ccatt): Then, Now and What’s Next
- 1 June 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 62 (6) , S35
Critical Care Aeromedical Teams (Ccatt): Then, Now and What’s Next