NVNiraj Varma

Niraj Varma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Niraj Varma has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Right Pectoral Implantable Cardioverter Defibrillators: Role of the Proximal (SVC) Coil

    by Niraj Varma, Igor Efimov

    Introduction: Increased defibrillation thresholds (DFTs) with right active pectoral implantable cardioverter defibrillators (ICDs) and/or right proximal coils (SVC) are attributed to poorer vector. However, SVC affects impedance, current flow, and shock waveform phase duration (PD), which exert independent DFT effects. Objective: Compare DFTs and shock characteristics in SVC On with SVC Off in right ICDs. Methods and Results : DFT+ testing (n = 42, 62% males, 62 ±15 years, left ventricular ejection fraction (LVEF) 26 ± 11%, ischemic cardiomyopathy 65%, amiodarone 26%) revealed >20% incidence of high DFT (>20J) . Dilated cardiomyopathy and amiodarone increased DFT. Individual impedance variability (25–74 Ω) generated a wide PD range (2.6–8.7 ms). Overall, SVC On reduced impedance by 33% (from 54 ± 10 to 35 ± 5Ω, P< 0.0001), and shortened PD (from 5.45 ± 1.20 to 3.67 ± 0.74 ms, P< 0.01). SVC On affected DFTs in 19/42 (45%) patients. SVC On was beneficial in 12/19. PD shortened but current flow remained unaltered. (In these, SVC Off impedance was >45Ω and PD >5 ms.) SVC On was detrimental in 7/19 despite increasing current flow. In these, PD shortened excessively (median 2.9 ms) because impedance was low (31 ± 4Ω). In 3/6 cases with DFTs >20 J in both SVC On and Off, PD optimization reduced DFT. Overall, selection of best SVC configuration or deliberate PD programming yielded DFTs ≤20 J in >90% patients, reducing need for system modification to Conclusions : Right pectoral active ICDs have high DFTs. The SVC coil may be detrimental when pulse waveform excessively shortens. Noninvasive maneuvers, for example, SVC and waveform optimization, may improve DFT.


  • Detection of Atrial Fibrillation by Implanted Devices with Wireless Data Transmission Capability

    by Niraj Varma, Bruce Stambler, Sung Chun

    Remote telemetry may facilitate the management of implantable devices. We tested the reliability of a new automatic, wireless home monitoring (HM) system that archives data every 24 hours. We retrospectively analyzed archival data from 276 consecutive pacing system implants to define temporal atrial fibrillation (AF) patterns and associated ventricular rate. An “AF day” was defined by a >20%/24 hour mode switch (MS) duration, irrespective of the MS number. Management decisions resulting from transmissions were noted. A pilot study confirmed that 89% of 22,356 transmissions were successful, of which >90% were received in 50% of 24 hours. Ventricular rates during 645 AF days in 29 patients averaged 95.1 ± 9.9 beats/min (median = 94 beats/min). Ventricular rates were >80 beats/min in 25 ± 30 AF days (median = 11 days). HM enabled rapid anticoagulation decisions. In recipients of implantable devices, automatic wireless telemetry with HM was efficient and reliable. Its application may overcome some current challenges in AF management by early notification and precise measurement of both AF burden and ventricular rate during AF.