Achyut Sapkota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Achyut Sapkota has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Masahiro Takei
5 shared publications- Kazuo Ohmi
Osaka Sangyo University
4 shared publications - Osamu Maruyama
National Institute of Advanced Industrial Science and Technology
4 shared publications - Ryo Kosaka
Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
3 shared publications - Takashi Yamane
Kobe University
3 shared publications Yuta Asakura
Division of Artificial Systems Science, Graduate Course of Mechanical Engineering, Chiba University, 1-33, Inage, Chiba, 263-8522, Japan
3 shared publications
Latest Publications
- 1 February 2017
- Published by Elsevier in Biophysical Journal
- Vol. 112 (3) , 304a
Electrical Circuit Modelling and Experimental Evaluation of the Blood Undergoing Thrombosis
- 1 February 2017
- Published by Elsevier in Biophysical Journal
- Vol. 112 (3) , 304a
Electrical Circuit Modelling and Experimental Evaluation of the Blood Undergoing Thrombosis
- 2 September 2015
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 34 (5) , 517-525
Noninvasive online measurement of particle size and concentration in liquid–particle mixture by estimating equivalent circuit of electrical double layer
Three electrical elements (i.e., resistance, capacitance, and relaxation frequency) of electrical double layer (EDL) formed around particles have been extracted by a measuring–fitting combination for a novel noninvasive online measurement technique of particle size and concentration in a liquid–particle mixture. The measuring–fitting combination means measuring the impedances with electrical-impedance spectroscopy (EIS) method, and fitting the equivalent circuit with Levenberg–Marquardt method. The liquid–particle mixture in the impedance measurement is made of sodium chloride solution and stainless particles; the equivalent circuit is established corresponding to the contents in the liquid–particle mixture. As a result, the influence of the particle size and concentration on the electrical elements in the EDL which are the resistance, capacitance, and relaxation frequency in the EDL are clarified and discussed. This method is useful for determination of the particle size and concentration in liquid–particle mixture.
- 2 September 2015
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 34 (5) , 517-525
Noninvasive online measurement of particle size and concentration in liquid–particle mixture by estimating equivalent circuit of electrical double layer
Three electrical elements (i.e., resistance, capacitance, and relaxation frequency) of electrical double layer (EDL) formed around particles have been extracted by a measuring–fitting combination for a novel noninvasive online measurement technique of particle size and concentration in a liquid–particle mixture. The measuring–fitting combination means measuring the impedances with electrical-impedance spectroscopy (EIS) method, and fitting the equivalent circuit with Levenberg–Marquardt method. The liquid–particle mixture in the impedance measurement is made of sodium chloride solution and stainless particles; the equivalent circuit is established corresponding to the contents in the liquid–particle mixture. As a result, the influence of the particle size and concentration on the electrical elements in the EDL which are the resistance, capacitance, and relaxation frequency in the EDL are clarified and discussed. This method is useful for determination of the particle size and concentration in liquid–particle mixture.
- 10 June 2015
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (4) , 346-353
Relative permittivity measurement during the thrombus formation process using the dielectric relaxation method for various hematocrit values
The relative permittivity ε′ and the dielectric loss ε″ for various hematocrit values H for static bovine blood condition have been measured using the dielectric relaxation method to detect thrombosis in real time. The suitable measurement frequency f m ranged within 60 kHz to 1 MHz, and the relaxation frequency of red blood cells (RBCs) f rc was observed to be 2 MHz. In the f m, the temporal change of normalized ε′ exhibited a minimum (called as bottom point). The bottom point was observed to be exponentially shortened as H increased. This characteristic of the ε′* minimum is discussed from three viewpoints: during fibrin formation, direct thrombus formation, and rouleaux formation processes. ε′* during the fibrin formation process decreased over time, irrespective of f. However, ε′* in f m during the direct thrombus formation process and during the aggregation formation process increased immediately and rapidly over time. Therefore, the ε′* bottom point in f m might be the indication of micrometer-scale thrombus formation by RBC aggregation due to fibrin formation.
- 10 June 2015
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (4) , 346-353
Relative permittivity measurement during the thrombus formation process using the dielectric relaxation method for various hematocrit values
The relative permittivity ε′ and the dielectric loss ε″ for various hematocrit values H for static bovine blood condition have been measured using the dielectric relaxation method to detect thrombosis in real time. The suitable measurement frequency f m ranged within 60 kHz to 1 MHz, and the relaxation frequency of red blood cells (RBCs) f rc was observed to be 2 MHz. In the f m, the temporal change of normalized ε′ exhibited a minimum (called as bottom point). The bottom point was observed to be exponentially shortened as H increased. This characteristic of the ε′* minimum is discussed from three viewpoints: during fibrin formation, direct thrombus formation, and rouleaux formation processes. ε′* during the fibrin formation process decreased over time, irrespective of f. However, ε′* in f m during the direct thrombus formation process and during the aggregation formation process increased immediately and rapidly over time. Therefore, the ε′* bottom point in f m might be the indication of micrometer-scale thrombus formation by RBC aggregation due to fibrin formation.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2015.27, 71-72
1B26 Change in relative permittivity by the thrombus volume and thrombus hematocrit
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2015.27, 71-72
1B26 Change in relative permittivity by the thrombus volume and thrombus hematocrit
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _W053006-1
W053006 The Electrical Impedance Measurement of Thrombus
When blood comes in contact with artificial systems it tends to clot more. Hence, blood clotting is the major issue in extracorporeal circulation. Due to this, the patients take regular anticoagulation medicine. The frequent use of such a medicine results to other consequences. Due to this, the optimum use of medicine is desirable. To address this issue, we have made an assessment of instrumentation systems based on electrical impedance measurement with the aim of developing a sensor to monitor the blood and detect the thrombogenic activities at the early stage. The experimental results obtained by monitoring the bovine blood are presented. It was understood that electrical resistivity can be a suitable parameter to detect embolus. And, change in capacitance was more specific to understand the thrombogenic process.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _W053006-1
W053006 The Electrical Impedance Measurement of Thrombus
When blood comes in contact with artificial systems it tends to clot more. Hence, blood clotting is the major issue in extracorporeal circulation. Due to this, the patients take regular anticoagulation medicine. The frequent use of such a medicine results to other consequences. Due to this, the optimum use of medicine is desirable. To address this issue, we have made an assessment of instrumentation systems based on electrical impedance measurement with the aim of developing a sensor to monitor the blood and detect the thrombogenic activities at the early stage. The experimental results obtained by monitoring the bovine blood are presented. It was understood that electrical resistivity can be a suitable parameter to detect embolus. And, change in capacitance was more specific to understand the thrombogenic process.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2012.24, _8E26-1_
8E26 Visualization of red blood cell concentration using process tomography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2012.24, _8E26-1_
8E26 Visualization of red blood cell concentration using process tomography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2010.23, 113-114
8F-09 Identification of the Blood Clot by Exploiting its Electrical Properties
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2010.23, 113-114
8F-09 Identification of the Blood Clot by Exploiting its Electrical Properties
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 10 January 2010
- Published by Springer Nature in Experiments in Fluids
- Vol. 48 (4) , 589-605
Particle tracking velocimetry with an ant colony optimization algorithm
- 10 January 2010
- Published by Springer Nature in Experiments in Fluids
- Vol. 48 (4) , 589-605
Particle tracking velocimetry with an ant colony optimization algorithm
- 27 October 2008
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 3 (6) , 612-619
Neural network approach to stereoscopic correspondence of three‐dimensional particle tracking velocimetry
Particle tracking velocimetry (PTV) is a reliable measurement technique for the quantitative study of fluid flows by observing the motion of the particles seeded in them and is widely used in several industrial applications. The nature of the flow can be precisely observed only if all the three components of the velocity are computed. In 3‐D PTV system, particles viewed by two (or more than two) stereoscopic cameras with a parallax have to be correctly paired at every synchronized time step. This is important because the 3‐D coordinates of individual particles cannot be computed without the knowledge of the correct stereo correspondence of the particles. In the present work, a neural network–based algorithm has been proposed for the stereoscopic particle pairing process. The correspondence between the particle pairs is modeled as a constrained optimization problem. The constraints are provided on the basis of the epipolar geometry of the particle images and on the basis of the uniqueness of the matched pairs. The results are tested with various standard images. Copyright © 2008 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 27 October 2008
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 3 (6) , 612-619
Neural network approach to stereoscopic correspondence of three‐dimensional particle tracking velocimetry
Particle tracking velocimetry (PTV) is a reliable measurement technique for the quantitative study of fluid flows by observing the motion of the particles seeded in them and is widely used in several industrial applications. The nature of the flow can be precisely observed only if all the three components of the velocity are computed. In 3‐D PTV system, particles viewed by two (or more than two) stereoscopic cameras with a parallax have to be correctly paired at every synchronized time step. This is important because the 3‐D coordinates of individual particles cannot be computed without the knowledge of the correct stereo correspondence of the particles. In the present work, a neural network–based algorithm has been proposed for the stereoscopic particle pairing process. The correspondence between the particle pairs is modeled as a constrained optimization problem. The constraints are provided on the basis of the epipolar geometry of the particle images and on the basis of the uniqueness of the matched pairs. The results are tested with various standard images. Copyright © 2008 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- Open Access
- 1 January 2008
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 28 (2) , 1049
Ant Colony optimization Based Particle Tracking Velocimetry
- 1 January 2008
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 28 (2) , 1049
Open AccessAnt Colony optimization Based Particle Tracking Velocimetry