Gatis Ikaunieks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gatis Ikaunieks has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Gunta Krumina
University of Latvia
3 shared publications - Karola Panke
University of Latvia
3 shared publications - Aiga Svede
University of Latvia
2 shared publications - Inese Petrovica
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia
2 shared publications Maris Ozolinsh
Department of Optometry and Vision Science, University of Latvia, Kengaraga Street 8, Riga, LV‐1063, Latvia
2 shared publicationsAiga Švede
Department of Optometry and Vision Science, Faculty of Physics and Mathematics, University of Latvia, 1 Jelgavas Str., LV-1004, Rīga , LATVIA
1 shared publication
Latest Publications
- Open Access
Cochineal Dyes and Dyeing Techniques in Historical Lielvārde-Type Patterned Sashes from Latvia: Analytical and Historical Evidence
Lielvārde-type patterned sashes are among the most recognisable symbols of Latvian cultural heritage, yet reliable information on their chronology, dyes, and dyeing technologies remains limited. This study investigates the red wool yarns of five historical Lielvārde-type patterned sashes from Latvian museum collections. The study combines UPLC–DAD/MS dye analysis, ICP–QQQ elemental analysis, reflectance-based colourimetric measurements, experimental dyeing, and the analysis of historical sources. The analytical results identified cochineal-derived anthraquinone compounds consistent with Mexican cochineal (Dactylopius coccus Costa) in all analysed samples. Elemental analysis revealed the presence of both aluminium- and tin-based mordanting systems, while experimental dyeing demonstrated that the bright red shades characteristic of the historical textiles were achieved by combining tin mordants with cream of tartar. The identification of tin provides the first analytical evidence for the use of tin-based mordants in historical Latvian peasant textiles. Historical sources further document the availability of cochineal, mordants, and imported textile materials in the Baltic region during the nineteenth century. The combined analytical and historical evidence indicates that the production of the analysed sashes was closely connected to broader European networks of trade, knowledge exchange, and technological development. The results also call for a reassessment of previously proposed dates and support a production period in the second half of the nineteenth century, most likely between the late 1850s and the 1870s. The study contributes new knowledge on historical dyeing technologies and the circulation of imported dyestuffs in the eastern Baltic region.
Open AccessCochineal Dyes and Dyeing Techniques in Historical Lielvārde-Type Patterned Sashes from Latvia: Analytical and Historical Evidence
Lielvārde-type patterned sashes are among the most recognisable symbols of Latvian cultural heritage, yet reliable information on their chronology, dyes, and dyeing technologies remains limited. This study investigates the red wool yarns of five historical Lielvārde-type patterned sashes from Latvian museum collections. The study combines UPLC–DAD/MS dye analysis, ICP–QQQ elemental analysis, reflectance-based colourimetric measurements, experimental dyeing, and the analysis of historical sources. The analytical results identified cochineal-derived anthraquinone compounds consistent with Mexican cochineal (Dactylopius coccus Costa) in all analysed samples. Elemental analysis revealed the presence of both aluminium- and tin-based mordanting systems, while experimental dyeing demonstrated that the bright red shades characteristic of the historical textiles were achieved by combining tin mordants with cream of tartar. The identification of tin provides the first analytical evidence for the use of tin-based mordants in historical Latvian peasant textiles. Historical sources further document the availability of cochineal, mordants, and imported textile materials in the Baltic region during the nineteenth century. The combined analytical and historical evidence indicates that the production of the analysed sashes was closely connected to broader European networks of trade, knowledge exchange, and technological development. The results also call for a reassessment of previously proposed dates and support a production period in the second half of the nineteenth century, most likely between the late 1850s and the 1870s. The study contributes new knowledge on historical dyeing technologies and the circulation of imported dyestuffs in the eastern Baltic region.
- Open Access
- 22 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11345
Retinal Straylight Measurements for Assessing Wear-Related Changes in Monthly Soft Contact Lenses
Visual quality in the human eye depends on the integrity of ocular structures. Soft contact lenses interact directly with these structures and can also serve as an external source of straylight. The purpose of this study was to quantify changes in optical quality among habitual wearers of monthly disposable silicone hydrogel soft contact lenses (SCLs) by comparing retinal straylight with new versus month-old lenses. Retinal straylight was measured using a C-Quant straylight meter in 33 young adults (22.0 ± 1.4 years) wearing either comfilcon A (n = 17) or lotrafilcon B (n = 16) lenses. Measurements were first performed with month-old SCLs that had been worn for ≤4 h that day; after lens replacement and a 15 min adaptation period, measurements were repeated with new SCLs. The mean decimal logarithm of the straylight parameter, log(s), was significantly higher with month-old SCLs (0.97 ± 0.17) than with new SCLs (0.86 ± 0.15; paired t-test, p < 0.001), yielding an average increase of Δlog(s) = 0.11 ± 0.08. No significant difference was found between materials. Thirty-six percent of participants reported end-of-cycle visual discomfort. These findings indicate that monthly SCLs at the end of the replacement period can measurably increase retinal straylight.
- 22 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11345
Open AccessRetinal Straylight Measurements for Assessing Wear-Related Changes in Monthly Soft Contact Lenses
Visual quality in the human eye depends on the integrity of ocular structures. Soft contact lenses interact directly with these structures and can also serve as an external source of straylight. The purpose of this study was to quantify changes in optical quality among habitual wearers of monthly disposable silicone hydrogel soft contact lenses (SCLs) by comparing retinal straylight with new versus month-old lenses. Retinal straylight was measured using a C-Quant straylight meter in 33 young adults (22.0 ± 1.4 years) wearing either comfilcon A (n = 17) or lotrafilcon B (n = 16) lenses. Measurements were first performed with month-old SCLs that had been worn for ≤4 h that day; after lens replacement and a 15 min adaptation period, measurements were repeated with new SCLs. The mean decimal logarithm of the straylight parameter, log(s), was significantly higher with month-old SCLs (0.97 ± 0.17) than with new SCLs (0.86 ± 0.15; paired t-test, p < 0.001), yielding an average increase of Δlog(s) = 0.11 ± 0.08. No significant difference was found between materials. Thirty-six percent of participants reported end-of-cycle visual discomfort. These findings indicate that monthly SCLs at the end of the replacement period can measurably increase retinal straylight.
- Open Access
- 8 July 2024
- Published by MDPI AG in Preprints.org
The Effect of Monthly Disposable Soft Contact Lenses on Retinal Straylight
Purpose of research was to determine changes in optical quality for monthly disposable soft contact lenses (SCL) wearers with new and monthly worn SCL. Retinal straylight was assessed in SCL wearers using a C-Quant straylight meter. The study included 33 participants (age 22 ± 1.4 years) who wore monthly disposable silicone hydrogel contact lenses. Measurements were taken with month-old SCL that had been worn for no more than 4 hours. Participants then replaced the old lenses with new ones. After a 15-minute adaptation period, straylight measurements were taken with the new SCL. A questionnaire was administered to all participants, inquiring about vision complaints and the type of contact lens material used. The decimal logarithm of the stray-light parameter, log(s), was notably higher with month-old SCL (log(s) = 0.97±0.17) than with brand-new SCL (log(s) = 0.86±0.15), p < 0.001. The average increase in retinal straylight after a month of SCL use was log(s) = 0.11 ± 0.08. The questionnaire revealed that 35% of participants observed a reduction in visual quality after wearing the contact lenses for a month. Results showed that monthly disposable soft contact lenses could reduce visual quality when scheduled replacement time has been reached.
- 8 July 2024
- Published by MDPI AG in Preprints.org
Open AccessThe Effect of Monthly Disposable Soft Contact Lenses on Retinal Straylight
Purpose of research was to determine changes in optical quality for monthly disposable soft contact lenses (SCL) wearers with new and monthly worn SCL. Retinal straylight was assessed in SCL wearers using a C-Quant straylight meter. The study included 33 participants (age 22 ± 1.4 years) who wore monthly disposable silicone hydrogel contact lenses. Measurements were taken with month-old SCL that had been worn for no more than 4 hours. Participants then replaced the old lenses with new ones. After a 15-minute adaptation period, straylight measurements were taken with the new SCL. A questionnaire was administered to all participants, inquiring about vision complaints and the type of contact lens material used. The decimal logarithm of the stray-light parameter, log(s), was notably higher with month-old SCL (log(s) = 0.97±0.17) than with brand-new SCL (log(s) = 0.86±0.15), p < 0.001. The average increase in retinal straylight after a month of SCL use was log(s) = 0.11 ± 0.08. The questionnaire revealed that 35% of participants observed a reduction in visual quality after wearing the contact lenses for a month. Results showed that monthly disposable soft contact lenses could reduce visual quality when scheduled replacement time has been reached.
- Open Access
Application of a New Device for Vision Relaxation in Computer Users
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.
Open AccessApplication of a New Device for Vision Relaxation in Computer Users
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.
- Open Access
The Effect of Stimulus Contrast and Spatial Position on Saccadic Eye Movement Parameters
(1) Background: Saccadic eye movements are rapid eye movements aimed to position the object image on the central retina, ensuring high-resolution data sampling across the visual field. Although saccadic eye movements are studied extensively, different experimental settings applied across different studies have left an open question of whether and how stimulus parameters can affect the saccadic performance. The current study aims to explore the effect of stimulus contrast and spatial position on saccadic eye movement latency, peak velocity and accuracy measurements. (2) Methods: Saccadic eye movement targets of different contrast levels were presented at four different spatial positions. The eye movements were recorded with a Tobii Pro Fusion video-oculograph (250 Hz). (3) Results: The results demonstrate a significant effect of stimulus spatial position on the latency and peak velocity measurements at a medium grey background, 30 cd/m2 (negative and positive stimulus polarity), light grey background, 90 cd/m2 (negative polarity), and black background, 3 cd/m2 (positive polarity). A significant effect of the stimulus spatial position was observed on the accuracy measurements when the saccadic eye movement stimuli were presented on a medium grey background (negative polarity) and on a black background. No significant effect of stimulus contrast was observed on the peak velocity measurements under all conditions. A significant stimulus contrast effect on latency and accuracy was observed only on a light grey background. (4) Conclusions: The best saccadic eye movement performance (lowest latency, highest peak velocity and accuracy measurements) can be observed when the saccades are oriented to the right and left from the central fixation point. Furthermore, when presenting the stimulus on a light grey background, a very low contrast stimuli should be considered carefully.
Open AccessThe Effect of Stimulus Contrast and Spatial Position on Saccadic Eye Movement Parameters
(1) Background: Saccadic eye movements are rapid eye movements aimed to position the object image on the central retina, ensuring high-resolution data sampling across the visual field. Although saccadic eye movements are studied extensively, different experimental settings applied across different studies have left an open question of whether and how stimulus parameters can affect the saccadic performance. The current study aims to explore the effect of stimulus contrast and spatial position on saccadic eye movement latency, peak velocity and accuracy measurements. (2) Methods: Saccadic eye movement targets of different contrast levels were presented at four different spatial positions. The eye movements were recorded with a Tobii Pro Fusion video-oculograph (250 Hz). (3) Results: The results demonstrate a significant effect of stimulus spatial position on the latency and peak velocity measurements at a medium grey background, 30 cd/m2 (negative and positive stimulus polarity), light grey background, 90 cd/m2 (negative polarity), and black background, 3 cd/m2 (positive polarity). A significant effect of the stimulus spatial position was observed on the accuracy measurements when the saccadic eye movement stimuli were presented on a medium grey background (negative polarity) and on a black background. No significant effect of stimulus contrast was observed on the peak velocity measurements under all conditions. A significant stimulus contrast effect on latency and accuracy was observed only on a light grey background. (4) Conclusions: The best saccadic eye movement performance (lowest latency, highest peak velocity and accuracy measurements) can be observed when the saccades are oriented to the right and left from the central fixation point. Furthermore, when presenting the stimulus on a light grey background, a very low contrast stimuli should be considered carefully.
- Open Access
- 26 October 2017
- Published by Walter de Gruyter GmbH in Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.
- Vol. 71 (5) , 387-391
Accommodative Amplitude in School-Age Children
In children, intensive near-work affects the accommodation system of the eye. Younger children, due to anatomical parameters, read at smaller distance than older children and we can expect that the accommodation system of younger can be affected more than that of older children. We wanted to test this hypothesis. Some authors showed that the norms of amplitude of accommodation (AA) developed by Hofstetter (1950) not always could be applied for children. We also wanted to verify these results. A total of 106 (age 7-15) children participated in the study. Distance visual acuity was measured for all children and only data of children with good visual acuity 1.0 or more (dec. units) were analysed (73 children). Accommodative amplitude was measured before and after lessons using subjective push-up technique (with RAF Near Point Ruler). The results showed that the amplitude of accommodation reduced significantly (p < 0.05) during the day and decrease of AA was similar in different age groups (about ~0.70 D). Additional measurements are needed to verify that the observed changes in AA were associated with fatigue effect. The results showed lower accommodation values compared to average values calculated according to the Hofstetter equation (p < 0.05).
- 26 October 2017
- Published by Walter de Gruyter GmbH in Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.
- Vol. 71 (5) , 387-391
Open AccessAccommodative Amplitude in School-Age Children
In children, intensive near-work affects the accommodation system of the eye. Younger children, due to anatomical parameters, read at smaller distance than older children and we can expect that the accommodation system of younger can be affected more than that of older children. We wanted to test this hypothesis. Some authors showed that the norms of amplitude of accommodation (AA) developed by Hofstetter (1950) not always could be applied for children. We also wanted to verify these results. A total of 106 (age 7-15) children participated in the study. Distance visual acuity was measured for all children and only data of children with good visual acuity 1.0 or more (dec. units) were analysed (73 children). Accommodative amplitude was measured before and after lessons using subjective push-up technique (with RAF Near Point Ruler). The results showed that the amplitude of accommodation reduced significantly (p < 0.05) during the day and decrease of AA was similar in different age groups (about ~0.70 D). Additional measurements are needed to verify that the observed changes in AA were associated with fatigue effect. The results showed lower accommodation values compared to average values calculated according to the Hofstetter equation (p < 0.05).
- Open Access
- 25 April 2017
- Published by Walter de Gruyter GmbH in Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.
- Vol. 71 (1-2) , 22-26
Visual Acuity in Myopes with Standard and Reversed Contrast Optotypes
The aim of this study was to assess the visual acuity of myopes with standard and reversed contrast optotypes and to determine how the visual acuity of myopes is affected by optical defocus and the type of optical correction, either contact lenses or spectacles. Twenty-three myopic subjects (18 and 23 years old) with uncorrected vision had their visual acuity assessed with both standard and reversed contrast optotypes. The study also included 10 myopes with contact lens as well as habitual spectacle correction. The visual acuity for myopes with uncorrected vision was better with reversed than standard contrast optotypes. Better reversed contrast than standard contrast visual acuity was obtained also with spectacle and contact lens correction. This result could be due in part to low order aberrations (optical defocus) in myopes spectacle or contact lenses correction.
- 25 April 2017
- Published by Walter de Gruyter GmbH in Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.
- Vol. 71 (1-2) , 22-26
Open AccessVisual Acuity in Myopes with Standard and Reversed Contrast Optotypes
The aim of this study was to assess the visual acuity of myopes with standard and reversed contrast optotypes and to determine how the visual acuity of myopes is affected by optical defocus and the type of optical correction, either contact lenses or spectacles. Twenty-three myopic subjects (18 and 23 years old) with uncorrected vision had their visual acuity assessed with both standard and reversed contrast optotypes. The study also included 10 myopes with contact lens as well as habitual spectacle correction. The visual acuity for myopes with uncorrected vision was better with reversed than standard contrast optotypes. Better reversed contrast than standard contrast visual acuity was obtained also with spectacle and contact lens correction. This result could be due in part to low order aberrations (optical defocus) in myopes spectacle or contact lenses correction.
- 15 April 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (3) , 351-356
Light scattering in artificial fog and simulated with light scattering filter
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a light scattering polymer dispersed liquid crystal (PDLC) filter with scatterers of submicron size in front of the normal eye. All measurements were made using each of three broad‐band color stimuli – red, green and blue (produced either with LEDs or a color CRT monitor). Differences were found in both the level and the spectral characteristics of scattering under the different conditions. The measured values of the straylight parameter, s , in artificial fog showed no noticeable spectral dependence at any visibility range. Increasing the visibility range caused an exponential decrease in the straylight. Intraocular straylight measured with the clear eye showed an increase at the red and blue ends of the spectrum as compared to the green. Straylight measured using PDLC plates with different transparency levels showed a spectral dependence which decreased with wavelength. The scattering introduced by the PDLC plate therefore failed to give a valid simulation of cataract and fog conditions for polychromatic stimuli, due to its erroneous spectral dependence.
- 15 April 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (3) , 351-356
Light scattering in artificial fog and simulated with light scattering filter
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a light scattering polymer dispersed liquid crystal (PDLC) filter with scatterers of submicron size in front of the normal eye. All measurements were made using each of three broad‐band color stimuli – red, green and blue (produced either with LEDs or a color CRT monitor). Differences were found in both the level and the spectral characteristics of scattering under the different conditions. The measured values of the straylight parameter, s , in artificial fog showed no noticeable spectral dependence at any visibility range. Increasing the visibility range caused an exponential decrease in the straylight. Intraocular straylight measured with the clear eye showed an increase at the red and blue ends of the spectrum as compared to the green. Straylight measured using PDLC plates with different transparency levels showed a spectral dependence which decreased with wavelength. The scattering introduced by the PDLC plate therefore failed to give a valid simulation of cataract and fog conditions for polychromatic stimuli, due to its erroneous spectral dependence.
- 21 October 2008
- Published by Taylor & Francis in Ferroelectrics
- Vol. 370 (1) , 18-28
Scattering and Depolarization in a Polymer Dispersed Liquid Crystal Cell
- 21 October 2008
- Published by Taylor & Francis in Ferroelectrics
- Vol. 370 (1) , 18-28
Scattering and Depolarization in a Polymer Dispersed Liquid Crystal Cell
- 1 January 2008
- Published by Springer Nature
- p. 367-370
Effect of Light Scattering Simulation in the Eye on Different Color Stimuli Perception
- 1 January 2008
- Published by Springer Nature
- p. 367-370
Effect of Light Scattering Simulation in the Eye on Different Color Stimuli Perception