Karola Panke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karola Panke has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Gunta Krumina
University of Latvia
11 shared publications - Tatjana Pladere
University of Latvia
10 shared publications - Aiga Svede
University of Latvia
3 shared publications - Gatis Ikaunieks
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, LV-1004 Riga, Latvia
3 shared publications Gunta Krumina
University of Latvia, Riga, Latvia
3 shared publicationsVita Konosonoka
Univ. of Latvia (Latvia)
3 shared publications
Latest Publications
- Open Access
- 11 March 2025
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 108 (3) , 327-335
Vision functionality and user comfort following the use of binocular indirect ophthalmoscope simulator
Headset-based simulator training is increasingly utilised in eye care education, offering opportunities to improve clinical skills in a controlled, reproducible environment. These tools support the development of innovative training approaches in eye care. While the educational advantages of headset-based simulators are recognised, the potential challenges and limitations that users may encounter remain understudied. This study investigated changes in user comfort and vision functionality following a 40-minute headset-based simulator training of indirect ophthalmoscopy. Fifty-four participants aged 20 to 45 years (21 eye care professionals and 33 optometry students, analysed as a single group) underwent a 40-minute training session using the Eyesi binocular indirect ophthalmoscope simulator. User comfort with a custom-designed symptom questionnaire and visual functions using the RAF ruler, von Graefe technique, and prism bars were assessed before and immediately after the headset-based simulator training session. Following the headset-based simulator training, there was a significant recession of both the near point of convergence (p < .001) and the near point of accommodation (p < .001). Baseline visual functions correlated with changes following headset-based simulator training, specifically near point of accommodation (r = 0.32, p = .02), horizontal near heterophoria (r = -0.37, p = .01), horizontal far heterophoria (r = 0.27, p = .04), blur point in positive fusional reserves (r = -0.61, p < .001), recovery point in negative fusional reserves (r = -0.36, p = .01), and AC/A ratio (r = -0.51, p < .001). Questionnaire results indicated a significant increase in discomfort following the headset-based simulator training (p < .001). Forty-minute headset-based simulator training can lead to altered vision functionality and pronounced discomfort in some individuals, highlighting the variability in individual responses to training indirect ophthalmoscopy skills in video see-through augmented reality.
- 11 March 2025
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 108 (3) , 327-335
Open AccessVision functionality and user comfort following the use of binocular indirect ophthalmoscope simulator
Headset-based simulator training is increasingly utilised in eye care education, offering opportunities to improve clinical skills in a controlled, reproducible environment. These tools support the development of innovative training approaches in eye care. While the educational advantages of headset-based simulators are recognised, the potential challenges and limitations that users may encounter remain understudied. This study investigated changes in user comfort and vision functionality following a 40-minute headset-based simulator training of indirect ophthalmoscopy. Fifty-four participants aged 20 to 45 years (21 eye care professionals and 33 optometry students, analysed as a single group) underwent a 40-minute training session using the Eyesi binocular indirect ophthalmoscope simulator. User comfort with a custom-designed symptom questionnaire and visual functions using the RAF ruler, von Graefe technique, and prism bars were assessed before and immediately after the headset-based simulator training session. Following the headset-based simulator training, there was a significant recession of both the near point of convergence (p < .001) and the near point of accommodation (p < .001). Baseline visual functions correlated with changes following headset-based simulator training, specifically near point of accommodation (r = 0.32, p = .02), horizontal near heterophoria (r = -0.37, p = .01), horizontal far heterophoria (r = 0.27, p = .04), blur point in positive fusional reserves (r = -0.61, p < .001), recovery point in negative fusional reserves (r = -0.36, p = .01), and AC/A ratio (r = -0.51, p < .001). Questionnaire results indicated a significant increase in discomfort following the headset-based simulator training (p < .001). Forty-minute headset-based simulator training can lead to altered vision functionality and pronounced discomfort in some individuals, highlighting the variability in individual responses to training indirect ophthalmoscopy skills in video see-through augmented reality.
- Open Access
Comparative Analysis of Physiological Vergence Angle Calculations from Objective Measurements of Gaze Position
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions. To address this, we proposed two methods to calculate the physiological vergence angle based on the visual vergence data obtained from PowerRef 3. Twenty-three participants aged 25 ± 4 years viewed Maltese cross stimuli at distances of 25, 30, 50, 70, and 600 cm. The expected vergence angles were calculated considering the individual interpupillary distance at far. Our results demonstrate that the PowerRef 3 gaze data deviated from the expected vergence angles by 9.64 ± 2.73° at 25 cm and 9.25 ± 3.52° at 6 m. The kappa angle calibration method reduced the discrepancy to 3.93 ± 1.19° at 25 cm and 3.70 ± 0.36° at 600 cm, whereas the linear regression method further improved the accuracy to 3.30 ± 0.86° at 25 cm and 0.26 ± 0.01° at 600 cm. Both methods improved the gaze results, with the linear regression calibration method showing greater overall accuracy.
Open AccessComparative Analysis of Physiological Vergence Angle Calculations from Objective Measurements of Gaze Position
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions. To address this, we proposed two methods to calculate the physiological vergence angle based on the visual vergence data obtained from PowerRef 3. Twenty-three participants aged 25 ± 4 years viewed Maltese cross stimuli at distances of 25, 30, 50, 70, and 600 cm. The expected vergence angles were calculated considering the individual interpupillary distance at far. Our results demonstrate that the PowerRef 3 gaze data deviated from the expected vergence angles by 9.64 ± 2.73° at 25 cm and 9.25 ± 3.52° at 6 m. The kappa angle calibration method reduced the discrepancy to 3.93 ± 1.19° at 25 cm and 3.70 ± 0.36° at 600 cm, whereas the linear regression method further improved the accuracy to 3.30 ± 0.86° at 25 cm and 0.26 ± 0.01° at 600 cm. Both methods improved the gaze results, with the linear regression calibration method showing greater overall accuracy.
- Open Access
Individual Variations in Vergence and Accommodation Responses Following Virtual Reality Gameplay
Virtual reality (VR) can challenge the visual system, leading to temporary oculomotor changes, though the degree of change varies among individuals. While the vergence and accommodation system plays a crucial role in VR perception, it remains unclear whether individuals whose visual functions fall outside clinical norms experience larger changes. Thus, our study aimed to investigate whether changes in vergence and accommodation responses following VR gameplay differ between individuals with and without non-strabismic binocular and accommodative disorders. To assess this, both subjective and objective measurements were conducted before and after 20 min of playing Beat Saber. Results revealed significant alterations across both subjective measurements—near point of convergence and near point of accommodation—and objective measurements, including eye refraction, accommodation lag, and accommodative microfluctuations at far. Moreover, individuals with non-strabismic binocular and accommodative disorders exhibited larger accommodative microfluctuations at far compared to the control group. Overall, these findings indicate that considering individual differences in vergence and accommodation responses is important when evaluating the impact of VR on the visual system and can be helpful in the design and use of VR systems, particularly for individuals with binocular and accommodative disorders.
Open AccessIndividual Variations in Vergence and Accommodation Responses Following Virtual Reality Gameplay
Virtual reality (VR) can challenge the visual system, leading to temporary oculomotor changes, though the degree of change varies among individuals. While the vergence and accommodation system plays a crucial role in VR perception, it remains unclear whether individuals whose visual functions fall outside clinical norms experience larger changes. Thus, our study aimed to investigate whether changes in vergence and accommodation responses following VR gameplay differ between individuals with and without non-strabismic binocular and accommodative disorders. To assess this, both subjective and objective measurements were conducted before and after 20 min of playing Beat Saber. Results revealed significant alterations across both subjective measurements—near point of convergence and near point of accommodation—and objective measurements, including eye refraction, accommodation lag, and accommodative microfluctuations at far. Moreover, individuals with non-strabismic binocular and accommodative disorders exhibited larger accommodative microfluctuations at far compared to the control group. Overall, these findings indicate that considering individual differences in vergence and accommodation responses is important when evaluating the impact of VR on the visual system and can be helpful in the design and use of VR systems, particularly for individuals with binocular and accommodative disorders.
- Open Access
Objective Refraction Status before and after Cycloplegia: From Childhood to Young Adulthood
This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of types of refractive error, as well as the relationship between age and cycloplegia-induced changes in the power of refractive errors. We analysed the records of 472 non-population-based ophthalmology practice patients aged 3–28 years (mean ± SD: 9.1 ± 4.6). Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and eye refraction was measured 30 ± 5 min later using an objective autorefractometer. Cycloplegia induced a clinically significant (≥0.50 D) hyperopic shift in the spherical equivalent of 60.2% of participants and a myopic shift in 1%, resulting in a 34.1% increase in the frequency of participants with hyperopia, while the frequency of those with myopia and emmetropia decreased by 5.5% and 23.3%, respectively. The average spherical equivalent difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3–5 years age group (1.18 ± 0.85 D). The differences in astigmatism power (p = 0.84) and astigmatism axis (p = 0.97) between non-cycloplegic and cycloplegic conditions were not statistically significant.
Open AccessObjective Refraction Status before and after Cycloplegia: From Childhood to Young Adulthood
This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of types of refractive error, as well as the relationship between age and cycloplegia-induced changes in the power of refractive errors. We analysed the records of 472 non-population-based ophthalmology practice patients aged 3–28 years (mean ± SD: 9.1 ± 4.6). Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and eye refraction was measured 30 ± 5 min later using an objective autorefractometer. Cycloplegia induced a clinically significant (≥0.50 D) hyperopic shift in the spherical equivalent of 60.2% of participants and a myopic shift in 1%, resulting in a 34.1% increase in the frequency of participants with hyperopia, while the frequency of those with myopia and emmetropia decreased by 5.5% and 23.3%, respectively. The average spherical equivalent difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3–5 years age group (1.18 ± 0.85 D). The differences in astigmatism power (p = 0.84) and astigmatism axis (p = 0.97) between non-cycloplegic and cycloplegic conditions were not statistically significant.
- Open Access
- 4 July 2024
- Published by MDPI AG in Preprints.org
Objective Refraction Status Before and After Cycloplegia: From Childhood to Young Adulthood
To accurately determine the refractive error of the eye, sufficient relaxation of eye accommodation is essential, either through the fogging technique or pharmacological cycloplegia. This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of eye refractive error. We analyzed the records of 472 non-population-based subjects aged 3–28 years (mean ± SD: 9.1 ± 4.6) who attended a private ophthalmology practice from January 2018 to December 2020. Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and refraction was measured 30 ± 5 min later using an objective autorefractometer. The average spherical equivalent (SE) difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3-5 years age group (1.18 ± 0.85 D). Gender had no significant effect on the SE values before or after cycloplegia (p > 0.05). Cycloplegia caused a hyperopic refractive shift in 83% of participants, no shift in 12%, and a myopic refractive shift in 6%. This study highlights the importance of cycloplegia use in children and young adults.
- 4 July 2024
- Published by MDPI AG in Preprints.org
Open AccessObjective Refraction Status Before and After Cycloplegia: From Childhood to Young Adulthood
To accurately determine the refractive error of the eye, sufficient relaxation of eye accommodation is essential, either through the fogging technique or pharmacological cycloplegia. This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of eye refractive error. We analyzed the records of 472 non-population-based subjects aged 3–28 years (mean ± SD: 9.1 ± 4.6) who attended a private ophthalmology practice from January 2018 to December 2020. Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and refraction was measured 30 ± 5 min later using an objective autorefractometer. The average spherical equivalent (SE) difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3-5 years age group (1.18 ± 0.85 D). Gender had no significant effect on the SE values before or after cycloplegia (p > 0.05). Cycloplegia caused a hyperopic refractive shift in 83% of participants, no shift in 12%, and a myopic refractive shift in 6%. This study highlights the importance of cycloplegia use in children and young adults.
- Open Access
Application of a New Device for Vision Relaxation in Computer Users
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.
Open AccessApplication of a New Device for Vision Relaxation in Computer Users
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.
- Open Access
- 23 September 2021
- Published by Estonian Academy Publishers in Proceedings of the Estonian Academy of Sciences
- Vol. 70 (4S) , 333-340
Accommodative response in various design soft contact lens wearers
The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22–28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design for accommodative lag compensation, the results of the accommodative lag with and without contact lenses were compared. The measured accommodative lag for stimuli at 40 cm was 1.05 ± 0.11 D and for stimuli at 25 cm 1.53 ± 0.11 D. Regarding the effect of multifocal contact lenses, it was determined that the near vision power zone in the centre of the lens reduces the accommodative lag, while the respective distance vision power zone does not produce a statistically significant change. The near power zone in the centre of the multifocal contact lens effectively affects the accommodative lag by reducing accommodation inaccuracy as effectively as spherical contact lenses with positive power. The addition design for multifocal lenses (Med or Hi) does not significantly affect the accommodative lag. The results of centre-distance multifocal contact lenses depend on the strength of the addition used.
- 23 September 2021
- Published by Estonian Academy Publishers in Proceedings of the Estonian Academy of Sciences
- Vol. 70 (4S) , 333-340
Open AccessAccommodative response in various design soft contact lens wearers
The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22–28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design for accommodative lag compensation, the results of the accommodative lag with and without contact lenses were compared. The measured accommodative lag for stimuli at 40 cm was 1.05 ± 0.11 D and for stimuli at 25 cm 1.53 ± 0.11 D. Regarding the effect of multifocal contact lenses, it was determined that the near vision power zone in the centre of the lens reduces the accommodative lag, while the respective distance vision power zone does not produce a statistically significant change. The near power zone in the centre of the multifocal contact lens effectively affects the accommodative lag by reducing accommodation inaccuracy as effectively as spherical contact lenses with positive power. The addition design for multifocal lenses (Med or Hi) does not significantly affect the accommodative lag. The results of centre-distance multifocal contact lenses depend on the strength of the addition used.
- Open Access
- 16 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4929
Visual Search Performance and Strategy for Three-Dimensional Visualization Systems: Impact of Radiologist Experience
The visual search performance of radiologists is systematically challenged due to the use of flat-panel displays when viewing multi-slice images. Three-dimensional visualization of information is expected to facilitate visual search for radiologists. However, as the differences in user performance, depending on radiologist experience, have not yet been assessed for real three-dimensional images, it is difficult to estimate the usability of new visualization systems for radiologists with different amounts of professional search experience. In this study, we aimed to determine how three-dimensional visual search is affected by radiologist experience and the physical properties of stimuli. Radiologists, residents, and medical students accomplished visual search tasks with varying set sizes and target-distractor similarities. Search items were presented on multiple display planes and image manipulation was conducted using a computer keyboard. We compared the search outcome and strategy among three groups of participants. All three groups submitted a similar number of correct responses depending on target-distractor similarity. However, in contrast to radiologists and residents, it took a considerably longer time for students to find the targets. The major differences were evident in search strategy when comparing the image manipulations of radiologists with those of residents and students. Our results demonstrated that experienced radiologists’ search performance benefited from seeing the entire three-dimensional view of an image, whereas residents and students focused instead on reducing the amount of information and searched in a selective manner. These findings should be taken into account when planning the implementation of new workstations with three-dimensional visualization in radiology.
- 16 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4929
Open AccessVisual Search Performance and Strategy for Three-Dimensional Visualization Systems: Impact of Radiologist Experience
The visual search performance of radiologists is systematically challenged due to the use of flat-panel displays when viewing multi-slice images. Three-dimensional visualization of information is expected to facilitate visual search for radiologists. However, as the differences in user performance, depending on radiologist experience, have not yet been assessed for real three-dimensional images, it is difficult to estimate the usability of new visualization systems for radiologists with different amounts of professional search experience. In this study, we aimed to determine how three-dimensional visual search is affected by radiologist experience and the physical properties of stimuli. Radiologists, residents, and medical students accomplished visual search tasks with varying set sizes and target-distractor similarities. Search items were presented on multiple display planes and image manipulation was conducted using a computer keyboard. We compared the search outcome and strategy among three groups of participants. All three groups submitted a similar number of correct responses depending on target-distractor similarity. However, in contrast to radiologists and residents, it took a considerably longer time for students to find the targets. The major differences were evident in search strategy when comparing the image manipulations of radiologists with those of residents and students. Our results demonstrated that experienced radiologists’ search performance benefited from seeing the entire three-dimensional view of an image, whereas residents and students focused instead on reducing the amount of information and searched in a selective manner. These findings should be taken into account when planning the implementation of new workstations with three-dimensional visualization in radiology.
- Open Access
Objective User Visual Experience Evaluation When Working with Virtual Pixel-Based 3D System and Real Voxel-Based 3D System
Volumetric display shows promising implications for healthcare related applications as an innovative technology that creates real three-dimensional (3D) image by illuminating points in three-dimensional space to generate volumetric images without image separation. We used eccentric photorefractometry to objectively study ocular performance in a practical environment by evaluating near work-induced refraction shift, accommodative microfluctuations, and pupil size for 38 young adults after viewing anaglyph, and volumetric 3D content for prolonged time. The results of our study demonstrate that participants who performed relative depth estimation task on volumetric 3D content were less likely to experience task-induced myopic refraction shift. For both 3D content types, we observed pupil constriction, that is possibly related to visual fatigue. For anaglyph 3D pupil constriction, onset was observed significantly sooner, compared to volumetric 3D. Overall, sustained work with 3D content, and small disparities or the fully eliminated possibility of accommodation-vergence conflict, not only minimizes near work-induced myopic shift, but also provide beneficial accommodation relaxation that was demonstrated in this study as hypermetropic shift for nearly half of participants.
Open AccessObjective User Visual Experience Evaluation When Working with Virtual Pixel-Based 3D System and Real Voxel-Based 3D System
Volumetric display shows promising implications for healthcare related applications as an innovative technology that creates real three-dimensional (3D) image by illuminating points in three-dimensional space to generate volumetric images without image separation. We used eccentric photorefractometry to objectively study ocular performance in a practical environment by evaluating near work-induced refraction shift, accommodative microfluctuations, and pupil size for 38 young adults after viewing anaglyph, and volumetric 3D content for prolonged time. The results of our study demonstrate that participants who performed relative depth estimation task on volumetric 3D content were less likely to experience task-induced myopic refraction shift. For both 3D content types, we observed pupil constriction, that is possibly related to visual fatigue. For anaglyph 3D pupil constriction, onset was observed significantly sooner, compared to volumetric 3D. Overall, sustained work with 3D content, and small disparities or the fully eliminated possibility of accommodation-vergence conflict, not only minimizes near work-induced myopic shift, but also provide beneficial accommodation relaxation that was demonstrated in this study as hypermetropic shift for nearly half of participants.
- Open Access
- 7 January 2019
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Ocular performance evaluation
- 7 January 2019
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Open AccessOcular performance evaluation