KEKatsuyoshi Endo

Katsuyoshi Endo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Katsuyoshi Endo has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adhesive-Free Adhesion between Plasma-Treated Glass-Cloth-Containing Polytetrafluoroethylene (GC–PTFE) and Stainless Steel: Comparison between GC–PTFE and Pure PTFE

    by Misa Nishino, Yuki Okazaki, Yosuke Seto, Tsuyoshi Uehara, Katsuyoshi Endo, Kazuya Yamamura, Yuji Ohkubo

    In this study, the effect of plasma treatment on glass-cloth-containing polytetrafluoroethylene (GC–PTFE) was investigated. Previous plasma studies investigated pure PTFE (which does not contain glass cloth) but not GC–PTFE. The effect of Ar + H2O plasma treatment on GC–PTFE was investigated. The Ar + H2O plasma-treated GC–PTFE sheets were thermally compressed to stainless steel (SUS304) foils without using adhesive, and the GC–PTFE/SUS304 adhesion strengths were measured using a 90° peel test. The adhesion strength increased with the increase in the plasma treatment time (0.8 and 1.0 N/mm at 20 s and 300 s, respectively). Thus, strong adhesion between GC–PTFE/SUS304 was achieved without adhesive. This improvement in the adhesion properties of GC–PTFE can be attributed to the generation of oxygen-containing functional groups and the decrease in the surface roughness of the samples. Thereafter, the adhesion properties of GC–PTFE and pure PTFE were compared. Because, unlike pure PTFE, GC–PTFE has no weak boundary layer, GC–PTFE exhibited better adhesion properties than pure PTFE under short plasma treatment times.


  • Open Access

    Effects of He and Ar Heat-Assisted Plasma Treatments on the Adhesion Properties of Polytetrafluoroethylene (PTFE)

    by Yuji Ohkubo, Yuki Okazaki, Masafumi Shibahara, Misa Nishino, Yosuke Seto, Katsuyoshi Endo, Kazuya Yamamura

    Heat-assisted plasma (HAP) treatment using He gas is known to improve the adhesive-bonding and adhesive-free adhesion properties of polytetrafluoroethylene (PTFE). In this study, we investigated the effects of He and Ar gaseous species on the HAP-treated PTFE surface. Epoxy (EP) adhesive-coated stainless steel (SUS304) and isobutylene–isoprene rubber (IIR) were used as adherents for the evaluation of the adhesive-bonding and adhesive-free adhesion properties of PTFE. In the case of adhesive bonding, the PTFE/EP-adhesive/SUS304 adhesion strength of the Ar-HAP-treated PTFE was the same as that of the He-HAP-treated PTFE. In the case of adhesive-free adhesion, the PTFE/IIR adhesion strength of the Ar-HAP-treated PTFE was seven times lower than that of the He-HAP-treated PTFE. The relation among gaseous species used in HAP treatment, adhesion properties, peroxy radical density ratio, surface chemical composition, surface modification depth, surface morphology, surface hardness, and the effect of irradiation with vacuum ultraviolet (VUV) and UV photons were investigated. The different adhesive-free adhesion properties obtained by the two treatments resulted from the changes in surface chemical composition, especially the ratios of oxygen-containing functional groups and C–C crosslinks.


  • Open Access

    Strong Biomimetic Immobilization of Pt-Particle Catalyst on ABS Substrate Using Polydopamine and Its Application for Contact-Lens Cleaning with H2O2

    by Yuji Ohkubo, Tomonori Aoki, Daisuke Kaibara, Satoshi Seino, Osamu Mori, Rie Sasaki, Katsuyoshi Endo, Kazuya Yamamura

    Polydopamine (PDA)—a known adhesive coating material—was used herein to strongly immobilize a Pt-particle catalyst on an acrylonitrile–butadiene–styrene copolymer (ABS) substrate. Previous studies have shown that the poor adhesion between Pt particles and ABS surfaces is a considerable problem, leading to low catalytic durability for H2O2 decomposition during contact-lens cleaning. First, the ABS substrate was coated with PDA, and the PDA film was evaluated by X-ray photoelectron spectroscopy. Second, Pt particles were immobilized on the PDA-coated ABS substrate (ABS-PDA) using the electron-beam irradiation reduction method. The Pt particles immobilized on ABS-PDA (Pt/ABS-PDA) were observed using a scanning electron microscope. The Pt-loading weight was measured by inductively coupled plasma atomic emission spectroscopy. Third, the catalytic activity of the Pt/ABS-PDA was evaluated as the residual H2O2 concentration after immersing it in a 35,000-ppm H2O2 solution (the target value was less than 100 ppm). The catalytic durability was evaluated as the residual H2O2 concentration after repeated use. The PDA coating drastically improved both the catalytic activity and durability because of the high Pt-loading weight and strong adhesion among Pt particles, PDA, and the ABS substrate. Plasma treatment prior to PDA coating further improved the catalytic durability.


  • Open Access

    Improved Catalytic Durability of Pt-Particle/ABS for H2O2 Decomposition in Contact Lens Cleaning

    by Yuji Ohkubo, Tomonori Aoki, Satoshi Seino, Osamu Mori, Issaku Ito, Katsuyoshi Endo, Kazuya Yamamura

    In a previous study, Pt nanoparticles were supported on a substrate of acrylonitrile–butadiene–styrene copolymer (ABS) to give the ABS surface catalytic activity for H2O2 decomposition during contact lens cleaning. Although the Pt-particle/ABS catalysts exhibited considerably high specific catalytic activity for H2O2 decomposition, the catalytic activity decreased with increasing numbers of repeated usage, which meant the durability of the catalytic activity was low. Therefore, to improve the catalytic durability in this study, we proposed two types of pretreatments, as well as a combination of these treatments before supporting Pt nanoparticles on the ABS substrate. In the first method, the ABS substrate was etched, and in the second method, the surface charge of the ABS substrate was controlled. A combination of etching and surface charge control was also applied as a third method. The effects of these pretreatments on the surface morphology, surface chemical composition, deposition behavior of Pt particles, and Pt loading weight were investigated by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), cross-sectional SEM, and inductively coupled plasma atomic emission spectroscopy (ICP-AES), respectively. Both etching and controlling the surface charge effectively improved the catalytic durability for H2O2 decomposition. In addition, the combination treatment was the most effective.


  • Open Access

    Radiolytic Synthesis of Pt-Particle/ABS Catalysts for H2O2 Decomposition in Contact Lens Cleaning

    by Yuji Ohkubo, Tomonori Aoki, Satoshi Seino, Osamu Mori, Issaku Ito, Katsuyoshi Endo, Kazuya Yamamura

    A container used in contact lens cleaning requires a Pt plating weight of 1.5 mg for H2O2 decomposition although Pt is an expensive material. Techniques that decrease the amount of Pt are therefore needed. In this study, Pt nanoparticles instead of Pt plating film were supported on a substrate of acrylonitrile–butadiene–styrene copolymer (ABS). This was achieved by the reduction of Pt ions in an aqueous solution containing the ABS substrate using high-energy electron-beam irradiation. Pt nanoparticles supported on the ABS substrate (Pt-particle/ABS) had a size of 4–10 nm. The amount of Pt required for Pt-particle/ABS was 250 times less than that required for an ABS substrate covered with Pt plating film (Pt-film/ABS). The catalytic activity for H2O2 decomposition was estimated by measuring the residual H2O2 concentration after immersing the catalyst for 360 min. The Pt-particle/ABS catalyst had a considerably higher specific catalytic activity for H2O2 decomposition than the Pt-film/ABS catalyst. In addition, sterilization performance was estimated from the initial rate of H2O2 decomposition over 60 min. The Pt-particle/ABS catalyst demonstrated a better sterilization performance than the Pt-film/ABS catalyst. The difference between Pt-particle/ABS and Pt-film/ABS was shown to reflect the size of the O2 bubbles formed during H2O2 decomposition.


  • Open Access

    High-spatial Resolution Figuring by Pulse Width Modulation Controlled Plasma Chemical Vaporization Machining

    by Kazuya Yamamura, Yoshiki Takeda, Shogo Sakaiya, Daisuke Funato, Katsuyoshi Endo


  • Open Access

    Profile measurement of concave spherical mirror and a flat mirror using a high-speed nanoprofiler

    by Koji Usuki, Takao Kitayama, Hiroki Matsumura, Takuya Kojima, Junichi Uchikoshi, Yasuo Higashi, Katsuyoshi Endo

    Ultraprecise aspheric mirrors that offer nanofocusing and high coherence are indispensable for developing third-generation synchrotron radiation and X-ray free-electron laser sources. In industry, the extreme ultraviolet (wavelength: 13.5 nm) lithography used for high-accuracy aspheric mirrors is a promising technology for fabricating semiconductor devices. In addition, ultraprecise mirrors with a radius of curvature of less than 10 mm are needed in many digital video instruments. We developed a new type of nanoprofiler that traces the normal vector of a mirror's surface. The principle of our measuring method is that the normal vector at each point on the surface is determined by making the incident light beam on the mirror surface and the reflected beam at that point coincide, using two sets of two pairs of goniometers and one linear stage. From the acquired normal vectors and their coordinates, the three-dimensional shape is calculated by a reconstruction algorithm. The characteristics of the measuring method are as follows: the profiler uses the straightness of laser light without using a reference surface. Surfaces of any shape can be measured, and there is no limit on the aperture size. We calibrated this nanoprofiler by considering the system error resulting from the assembly error and encoder scale error, and evaluated the performance at the nanometer scale. We suppressed the effect of random errors by maintaining the temperature in a constant-temperature room within ±0.01°C. We measured a concave spherical mirror with a radius of curvature of 400 mm and a flat mirror and compared the results with those obtained using a Fizeau interferometer. The profiles of the mirrors were consistent within the range of system errors.