Akinaga Sonoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akinaga Sonoda has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Kiyoshi Murata
Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan
7 shared publications - Masashi Takahashi
Shiga University of Medical Science
6 shared publications Kiyoshi Murata
Shiga University of Medical Science
5 shared publicationsNorihisa Nitta
Shiga University of Medical Science
5 shared publications- Norihisa Nitta
Department of Radiology, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, 520-2192, Japan
5 shared publications Shinichi Ohta
Shiga University of Medical Science
5 shared publications
Latest Publications
- 21 February 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (4) , 585-590
An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve
- 21 February 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (4) , 585-590
An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve
- 1 September 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1053) , 20150167
MRI study of atherosclerotic plaque progression using ultrasmall superparamagnetic iron oxide in Watanabe heritable hyperlipidemic rabbits
The purpose of this study was to evaluate plaque progression by using MRI with ultrasmall superparamagnetic iron oxide (USPIO) and by histopathological studies. We divided 12 Watanabe heritable hyperlipidemic (WHHL) rabbits into 4 groups based on their age (3, 9, 14 and 26 months) and injected them intravenously with 0.8 mmol (Fe) kg(-1) of USPIO (size, 32 nm; concentration, 15 mg dl(-1)). On the fifth post-injection day, they were again given an intravenous injection with 40 μmol kg(-1) of the same USPIO, and MR angiography (MRA) was performed. The signal-to-noise ratio (SNR) in regions of interest in the wall of the upper abdominal aorta was calculated on coronal images. Specimens from the same level of the aorta were subjected to iron staining and RAM-11 immunostaining and used for histopathological study. For statistical analysis of the MRA and histopathological findings, we used analysis of variance [Tukey's honest significant difference (HSD) test]. In 9-month-old rabbits, the SNR was significantly lower than in rabbits of the other ages (p < 0.01), and the area of RAM-11 (DAKO Corporation, Glostrup, Denmark) and iron uptake in the aortic wall was significantly larger (RAM-11, p < 0.01; iron, p < 0.05). These areas were the smallest in 3-month-old rabbits. Histopathologically, the number of macrophages was the greatest in 9-month-old rabbits. Our findings indicate that the SNR on MRI scans reflects the number of macrophages in the aortic wall of WHHL rabbits. USPIO-enhanced MRI visualized the accumulation of macrophages in early atherosclerotic plaques of WHHL rabbits in the course of natural progression.
- 1 September 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1053) , 20150167
MRI study of atherosclerotic plaque progression using ultrasmall superparamagnetic iron oxide in Watanabe heritable hyperlipidemic rabbits
The purpose of this study was to evaluate plaque progression by using MRI with ultrasmall superparamagnetic iron oxide (USPIO) and by histopathological studies. We divided 12 Watanabe heritable hyperlipidemic (WHHL) rabbits into 4 groups based on their age (3, 9, 14 and 26 months) and injected them intravenously with 0.8 mmol (Fe) kg(-1) of USPIO (size, 32 nm; concentration, 15 mg dl(-1)). On the fifth post-injection day, they were again given an intravenous injection with 40 μmol kg(-1) of the same USPIO, and MR angiography (MRA) was performed. The signal-to-noise ratio (SNR) in regions of interest in the wall of the upper abdominal aorta was calculated on coronal images. Specimens from the same level of the aorta were subjected to iron staining and RAM-11 immunostaining and used for histopathological study. For statistical analysis of the MRA and histopathological findings, we used analysis of variance [Tukey's honest significant difference (HSD) test]. In 9-month-old rabbits, the SNR was significantly lower than in rabbits of the other ages (p < 0.01), and the area of RAM-11 (DAKO Corporation, Glostrup, Denmark) and iron uptake in the aortic wall was significantly larger (RAM-11, p < 0.01; iron, p < 0.05). These areas were the smallest in 3-month-old rabbits. Histopathologically, the number of macrophages was the greatest in 9-month-old rabbits. Our findings indicate that the SNR on MRI scans reflects the number of macrophages in the aortic wall of WHHL rabbits. USPIO-enhanced MRI visualized the accumulation of macrophages in early atherosclerotic plaques of WHHL rabbits in the course of natural progression.
- 1 January 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 202 (1) , 2-12
Images Acquired Using 320-MDCT With Adaptive Iterative Dose Reduction With Wide-Volume Acquisition: Visual Evaluation of Image Quality by 10 Radiologists Using an Abdominal Phantom
The purpose of this study is to assess visual evaluations of CT images and to determine by how much radiation exposure dose could be reduced without compromising the image quality. An abdominal CT phantom was scanned at 14 different tube currents. Raw data were reconstructed with adaptive iterative dose reduction (AIDR) 3D and filtered backprojection (FBP). We divided 64 different image pairs into five groups. Group A consisted of 14 image pairs acquired with AIDR 3D and FBP, groups B and D consisted of 13 pairs with a one-level exposure dose decrease in AIDR 3D and FBP, respectively, and groups C and E consisted of 12 pairs with a two-level exposure dose decrease in AIDR 3D and FBP, respectively. Ten radiologists participated in the reading session. Statistical analyses were calculated with analysis of variance and the paired Student t test. Analysis of variance of six criteria revealed that the results were better in groups A, D, and E when AIDR 3D was applied. Better results were obtained with FBP in groups B and C. When we subjected evaluations of the renal parenchyma to the Student t test, we found that the assigned scores were better with AIDR 3D in groups A, D, and E and better with FBP in groups B and C. Similar results were obtained for the other evaluation criteria. Visual subjective evaluation showed that images of acceptable quality could be obtained at dose reductions of approximately 10% in the high-dose range and about 20% in the moderate-dose range.
- 1 January 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 202 (1) , 2-12
Images Acquired Using 320-MDCT With Adaptive Iterative Dose Reduction With Wide-Volume Acquisition: Visual Evaluation of Image Quality by 10 Radiologists Using an Abdominal Phantom
The purpose of this study is to assess visual evaluations of CT images and to determine by how much radiation exposure dose could be reduced without compromising the image quality. An abdominal CT phantom was scanned at 14 different tube currents. Raw data were reconstructed with adaptive iterative dose reduction (AIDR) 3D and filtered backprojection (FBP). We divided 64 different image pairs into five groups. Group A consisted of 14 image pairs acquired with AIDR 3D and FBP, groups B and D consisted of 13 pairs with a one-level exposure dose decrease in AIDR 3D and FBP, respectively, and groups C and E consisted of 12 pairs with a two-level exposure dose decrease in AIDR 3D and FBP, respectively. Ten radiologists participated in the reading session. Statistical analyses were calculated with analysis of variance and the paired Student t test. Analysis of variance of six criteria revealed that the results were better in groups A, D, and E when AIDR 3D was applied. Better results were obtained with FBP in groups B and C. When we subjected evaluations of the renal parenchyma to the Student t test, we found that the assigned scores were better with AIDR 3D in groups A, D, and E and better with FBP in groups B and C. Similar results were obtained for the other evaluation criteria. Visual subjective evaluation showed that images of acceptable quality could be obtained at dose reductions of approximately 10% in the high-dose range and about 20% in the moderate-dose range.
- 12 September 2012
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (2) , 89-96
320-detector-row computed tomography arteriography using CO2gas to detect malignant liver tumors
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas (320-MDCT CO2 arteriography) to detect the vascular area of malignant liver tumors. This study was approved by the Ethics Committee of our institution. Written prior informed consent was obtained from all patients. We studied six patients with primary and metastatic liver tumors (n = 26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/sec (volume 8 ml) into the common hepatic artery and a CT scan was acquired 12 seconds after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. Cramer's V statistic was performed to explore the relationship (p < 0.05). The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images. 320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.
- 12 September 2012
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (2) , 89-96
320-detector-row computed tomography arteriography using CO2gas to detect malignant liver tumors
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas (320-MDCT CO2 arteriography) to detect the vascular area of malignant liver tumors. This study was approved by the Ethics Committee of our institution. Written prior informed consent was obtained from all patients. We studied six patients with primary and metastatic liver tumors (n = 26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/sec (volume 8 ml) into the common hepatic artery and a CT scan was acquired 12 seconds after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. Cramer's V statistic was performed to explore the relationship (p < 0.05). The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images. 320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.
- Open Access
- 28 December 2011
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 5 (1) , 595
Tracheo-brachiocephalic artery fistula after tracheostomy associated with thoracic deformity: a case report
Introduction: Tracheo-brachiocephalic artery fistulae are critical long-term complications after tracheostomy, reported in 0.6% of patients within three to four weeks after the procedure. In 30% to 50% of cases there is some bleeding prior to onset. Since the onset involves sudden massive bleeding, the prognosis is poor; the reported survival rate is 10% to 30%. The direct cause of bleeding is the formation of a fistula with the trachea subsequent to arterial injury by the tracheostomy tube. Endo-tracheal factors are movement of the tracheostomy tube due to body movement and seizures, pressure exerted by the cuff of the tracheostomy tube, tracheostomy at lower levels, and the fragility of blood vessels and the trachea due to steroid or radiation therapy, and malnutrition. Extra-tracheal factors include prior surgery and deformity and shifting of the trachea and major blood vessels due to congenital kyphoscoliosis or thoracic deformity. There has been no report of the usefulness of contrast-enhanced computed tomography studies to identify the anatomical relationship between the trachea and brachiocephalic artery. Case presentation: A 27-year-old Mongolian woman with congenital muscular dystrophy who underwent tracheal intubation for airway management due to pneumonia and granulation development developed a tracheo-brachiocephalic artery fistula during the placement of the tracheostomy tube. It was diagnosed by contrast-enhanced chest computed tomography and repaired. About a month later she developed massive airway bleeding during replacement of the tracheostomy tube. Temporary hemostasis was achieved by compression via cuff inflation. A contrast-enhanced chest computed tomography scan demonstrated a narrowed brachiocephalic artery running along and ventral to the tube and a tracheo-brachiocephalic artery fistula was suspected. She underwent brachiocephalic artery resection and aorta, right common carotid artery, and subclavian artery bypass surgery with an innominate vein, tracheoplasty, and partial sternectomy. We noted marked thoracic deformity; the brachiocephalic artery was compressed by the trachea and chest wall resulting in localized wall necrosis and the development of a tracheo-brachiocephalic artery fistula, a fatal complication whose prevention is important. Conclusions: We suggest that before tracheostomy, the anatomic relationship between the trachea and brachiocephalic artery must be confirmed by contrast-enhanced chest computed tomography scan.
- 28 December 2011
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 5 (1) , 595
Open AccessTracheo-brachiocephalic artery fistula after tracheostomy associated with thoracic deformity: a case report
Introduction: Tracheo-brachiocephalic artery fistulae are critical long-term complications after tracheostomy, reported in 0.6% of patients within three to four weeks after the procedure. In 30% to 50% of cases there is some bleeding prior to onset. Since the onset involves sudden massive bleeding, the prognosis is poor; the reported survival rate is 10% to 30%. The direct cause of bleeding is the formation of a fistula with the trachea subsequent to arterial injury by the tracheostomy tube. Endo-tracheal factors are movement of the tracheostomy tube due to body movement and seizures, pressure exerted by the cuff of the tracheostomy tube, tracheostomy at lower levels, and the fragility of blood vessels and the trachea due to steroid or radiation therapy, and malnutrition. Extra-tracheal factors include prior surgery and deformity and shifting of the trachea and major blood vessels due to congenital kyphoscoliosis or thoracic deformity. There has been no report of the usefulness of contrast-enhanced computed tomography studies to identify the anatomical relationship between the trachea and brachiocephalic artery. Case presentation: A 27-year-old Mongolian woman with congenital muscular dystrophy who underwent tracheal intubation for airway management due to pneumonia and granulation development developed a tracheo-brachiocephalic artery fistula during the placement of the tracheostomy tube. It was diagnosed by contrast-enhanced chest computed tomography and repaired. About a month later she developed massive airway bleeding during replacement of the tracheostomy tube. Temporary hemostasis was achieved by compression via cuff inflation. A contrast-enhanced chest computed tomography scan demonstrated a narrowed brachiocephalic artery running along and ventral to the tube and a tracheo-brachiocephalic artery fistula was suspected. She underwent brachiocephalic artery resection and aorta, right common carotid artery, and subclavian artery bypass surgery with an innominate vein, tracheoplasty, and partial sternectomy. We noted marked thoracic deformity; the brachiocephalic artery was compressed by the trachea and chest wall resulting in localized wall necrosis and the development of a tracheo-brachiocephalic artery fistula, a fatal complication whose prevention is important. Conclusions: We suggest that before tracheostomy, the anatomic relationship between the trachea and brachiocephalic artery must be confirmed by contrast-enhanced chest computed tomography scan.
- 9 April 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (6) , 1272-1277
Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization
- 9 April 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (6) , 1272-1277
Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization
- 18 January 2011
- Published by Elsevier in Academic Radiology
- Vol. 18 (4) , 525-529
The Possibility of Differentiation between Nonalcoholic Steatohepatitis and Fatty Liver in Rabbits on Gd-EOB-DTPA-enhanced Open-type MRI Scans
- 18 January 2011
- Published by Elsevier in Academic Radiology
- Vol. 18 (4) , 525-529
The Possibility of Differentiation between Nonalcoholic Steatohepatitis and Fatty Liver in Rabbits on Gd-EOB-DTPA-enhanced Open-type MRI Scans
- 12 November 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (1) , 135-142
Controlled Release and Antitumor Effect of Pluronic F127 Mixed with Cisplatin in a Rabbit Model
The purpose of this study was to evaluate pluronic F127 for the controlled release of cisplatin in a rabbit model. Pluronic F127 becomes liquid at temperatures n = 3, renal group A) or saline + cisplatin (n = 3, renal group B) to measure the platinum concentration in kidneys. Another 25 rabbits with VX2 liver tumors were divided into five equal groups. They were injected with saline, saline + cisplatin, iodized oil + cisplatin, pluronic alone, or pluronic + cisplatin and labeled as liver groups A, B, C, D, and E, respectively. The antitumor effect of pluronic was then assessed. In the presence of pluronic, the platinum concentration in the kidneys of rabbits remained relatively high. In animals with liver tumors, the delivery of pluronic + cisplatin produced higher tumor reduction rates (P < 0.05) than in the other groups, without apparent damage to normal liver tissue. We conclude that pluronic is useful for the controlled release of cisplatin in a rabbit model.
- 12 November 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (1) , 135-142
Controlled Release and Antitumor Effect of Pluronic F127 Mixed with Cisplatin in a Rabbit Model
The purpose of this study was to evaluate pluronic F127 for the controlled release of cisplatin in a rabbit model. Pluronic F127 becomes liquid at temperatures n = 3, renal group A) or saline + cisplatin (n = 3, renal group B) to measure the platinum concentration in kidneys. Another 25 rabbits with VX2 liver tumors were divided into five equal groups. They were injected with saline, saline + cisplatin, iodized oil + cisplatin, pluronic alone, or pluronic + cisplatin and labeled as liver groups A, B, C, D, and E, respectively. The antitumor effect of pluronic was then assessed. In the presence of pluronic, the platinum concentration in the kidneys of rabbits remained relatively high. In animals with liver tumors, the delivery of pluronic + cisplatin produced higher tumor reduction rates (P < 0.05) than in the other groups, without apparent damage to normal liver tissue. We conclude that pluronic is useful for the controlled release of cisplatin in a rabbit model.
- Open Access
- 28 September 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (4) , 907-910
Investigation using an HER-2/neu transgenic mouse model of a newly developed MR contrast agent with the effect of an antitumor drug
- 28 September 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (4) , 907-910
Open AccessInvestigation using an HER-2/neu transgenic mouse model of a newly developed MR contrast agent with the effect of an antitumor drug