320-detector-row computed tomography arteriography using CO2gas to detect malignant liver tumors
- 12 September 2012
- journal article
- clinical trial
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (2) , 89-96
Abstract
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas (320-MDCT CO2 arteriography) to detect the vascular area of malignant liver tumors. This study was approved by the Ethics Committee of our institution. Written prior informed consent was obtained from all patients. We studied six patients with primary and metastatic liver tumors (n = 26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/sec (volume 8 ml) into the common hepatic artery and a CT scan was acquired 12 seconds after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. Cramer's V statistic was performed to explore the relationship (p < 0.05). The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images. 320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.Keywords
This publication has 11 references indexed in Scilit:
- Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CTEuropean Journal of Radiology, 2011
- Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCTEuropean Radiology, 2011
- Outcome of small liver nodules detected by computed tomographic angiography in patients with hepatocellular carcinomaHepatology International, 2010
- Dynamic CT Angiography and CT Perfusion Employing a 320-Detector Row CTClinical Neuroradiology, 2009
- Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scannerPhysics in Medicine & Biology, 2009
- Carbon Dioxide Contrast Agent for CT Arteriography: Results in a Porcine ModelJournal of Vascular and Interventional Radiology, 2008
- CO2-Enhanced CT Imaging for the Detection of Pulmonary Emboli: Feasibility Study in a Porcine ModelAcademic Radiology, 2003
- CO2 angiographyCatheterization and Cardiovascular Interventions, 2002
- Adverse reactions to iodinated contrast mediaEuropean Radiology, 2001
- Transcatheter oily chemoembolization of hepatocellular carcinoma.Radiology, 1989