Graziela Galhano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Graziela Galhano has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Marco Antonio Bottino
Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, MI 48109, USA
14 shared publications - Luiz Felipe Valandro
MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
12 shared publications - Renata Marques de Melo
Department of Dental Materials and Prosthodontics, Institute of Science and Technology, Sao Paulo State University (UNESP), Sao Jose dos Campos, Brazil
9 shared publications - Mutlu Özcan
Center for Dental Medicine, Clinic of Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland
4 shared publications Paolo Baldissara
3 shared publicationsRoberto Scotti
3 shared publications
Latest Publications
- 9 October 2026
- Published by Wiley in Gerodontology
Treatment of Oral Mucosa Self‐Injury in Older Patient With Neurological Disorder: Case Report
Objective: To describe the management of oral self‐injury in an older patient with neurological impairment using a digitally fabricated mouthguard. Background: Oral self‐injury may be challenging in patients with neurological conditions. Materials and Methods: An acrylic resin mouthguard was fabricated from intraoral scans for an 82‐year‐old bedridden woman. Photobiomodulation and oral hygiene measures were also used. Results: The lesion healed, and recurrent trauma was prevented. Conclusion: Intraoral scanning enabled comfortable fabrication of the oral device.
- 9 October 2026
- Published by Wiley in Gerodontology
Treatment of Oral Mucosa Self‐Injury in Older Patient With Neurological Disorder: Case Report
Objective: To describe the management of oral self‐injury in an older patient with neurological impairment using a digitally fabricated mouthguard. Background: Oral self‐injury may be challenging in patients with neurological conditions. Materials and Methods: An acrylic resin mouthguard was fabricated from intraoral scans for an 82‐year‐old bedridden woman. Photobiomodulation and oral hygiene measures were also used. Results: The lesion healed, and recurrent trauma was prevented. Conclusion: Intraoral scanning enabled comfortable fabrication of the oral device.
- Open Access
- 3 July 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (8)
Reparo em resina composta usando adesivo universal melhora a estabilidade da união
Repair in resin-based composite is a procedure that has shown good results, when properly indicated. In cases of fracture or stainning, the total removal of the restoration can cause unnecessary wear on the dental element. This study evaluated the aging effect on the bond strength of a universal adhesive containing silane, and/or application of silane separately for composite repairs. Resin composite blocks were thermocycled and divided according to adhesion protocol (n=10): silane(Sil), conventional adhesive(CA), universal adhesive(UA), Sil+CA(SilCA), and Sil+UA(SilUA). Layers of resin composite were added and blocks were sectioned and divided into 2 subgroups: 24h and 4 months of water storage. Microtensile bond strength test was performed and data were statistically analyzed (a = 0.05). After 4months of aging SilCA and SilUA showed a significant bond strength reduction, while for UA the bonding remained stable.
- 3 July 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (8)
Open AccessReparo em resina composta usando adesivo universal melhora a estabilidade da união
Repair in resin-based composite is a procedure that has shown good results, when properly indicated. In cases of fracture or stainning, the total removal of the restoration can cause unnecessary wear on the dental element. This study evaluated the aging effect on the bond strength of a universal adhesive containing silane, and/or application of silane separately for composite repairs. Resin composite blocks were thermocycled and divided according to adhesion protocol (n=10): silane(Sil), conventional adhesive(CA), universal adhesive(UA), Sil+CA(SilCA), and Sil+UA(SilUA). Layers of resin composite were added and blocks were sectioned and divided into 2 subgroups: 24h and 4 months of water storage. Microtensile bond strength test was performed and data were statistically analyzed (a = 0.05). After 4months of aging SilCA and SilUA showed a significant bond strength reduction, while for UA the bonding remained stable.
- 23 March 2019
- Vol. 30 (1) , 127-129
CAD/CAM system influence marginal fit of different ceramic types?
This study aimed to evaluate the marginal fit of zirconia and lithium disilicate ceramic restorations processed by computer-aided design (CAD)/computer-aided manufacturing (CAM) system. Ten models were prepared from a metal die, on which scanning was carried out to obtain the virtual model for the processing of zirconia and lithium disilicate ceramics using the CAD/CAM technique. Gypsum models were fabricated and used for scanning the restorations. The infrastructures were designed using software, and CAD/CAM was used to fabricate the restorations (n = 10). The analysis of the marginal discrepancy was measured at 12 points of the margin using the original metallic die. For each crown, an arithmetic average of the discrepancy values was obtained. The marginal fit of the copings of lithium disilicate was 133.10 ± 26.87 μm and zirconia was 127.34 ± 47.97 μm. There was no statistically significant difference (P = 0.7709) between the materials. The marginal fit is similar between lithium disilicate and zirconia ceramics milled in the CAD/CAM system used.
- 23 March 2019
- Vol. 30 (1) , 127-129
CAD/CAM system influence marginal fit of different ceramic types?
This study aimed to evaluate the marginal fit of zirconia and lithium disilicate ceramic restorations processed by computer-aided design (CAD)/computer-aided manufacturing (CAM) system. Ten models were prepared from a metal die, on which scanning was carried out to obtain the virtual model for the processing of zirconia and lithium disilicate ceramics using the CAD/CAM technique. Gypsum models were fabricated and used for scanning the restorations. The infrastructures were designed using software, and CAD/CAM was used to fabricate the restorations (n = 10). The analysis of the marginal discrepancy was measured at 12 points of the margin using the original metallic die. For each crown, an arithmetic average of the discrepancy values was obtained. The marginal fit of the copings of lithium disilicate was 133.10 ± 26.87 μm and zirconia was 127.34 ± 47.97 μm. There was no statistically significant difference (P = 0.7709) between the materials. The marginal fit is similar between lithium disilicate and zirconia ceramics milled in the CAD/CAM system used.
- 1 November 2012
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 23 (6) , e575-e579
Optical Impression Systems for CAD-CAM Restorations
Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).
- 1 November 2012
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 23 (6) , e575-e579
Optical Impression Systems for CAD-CAM Restorations
Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).
- 1 December 2011
- Vol. 13 (6) , 569-577
Effect of Static and Cyclic Loading on Ceramic Laminate Veneers Adhered to Teeth with and Without Aged Composite Restorations
Existing composite restorations on teeth are often remade prior to the cementation of fixed dental prostheses. The aim of this study was to evaluate the effect of static and cyclic loading on ceramic laminate veneers adhered to aged resin composite restorations. Eighty sound maxillary incisors were collected and randomly divided into four groups: group 1: control group, no restorations; group 2: two Class III restorations; group 3: two Class IV restorations; group 4: complete composite substrate. Standard composite restorations were made using a microhybrid resin composite (Anterior Shine). Restored teeth were subjected to thermocycling (6000 cycles). Window preparations were made on the labial surface of the teeth for ceramic laminate fabrication (Empress II). Teeth were conditioned using an etch-and-rinse system. Existing composite restorations representing the aged composites were silica coated (CoJet) and silanized (ESPE-Sil). Ceramic laminates were cemented using a bis-GMA-based cement (Variolink Veneer). The specimens were randomly divided into two groups and were subjected to either static (groups 1a, 2a, 3a, 4a) or cyclic loading (groups 1b, 2b, 3b, 4b). Failure type and location after loading were classified. Data were analyzed using one-way ANOVA and Tukey's test. Significantly higher fracture strength was obtained in group 4 (330 ± 81 N) compared to the controls in group 1 (179 ± 120 N) (one-way ANOVA, p < 0.05). Group 1b survived a lower mean number of cyclic loads (672,820 cycles) than teeth of groups 2b to 4b (846x103 to 873x103 cycles). Failure type evaluation after the fracture test showed predominantly adhesive failures between dentin and cement, but after cyclic loading, more cohesive fractures in the ceramic were seen. Ceramic laminate veneers bonded to conditioned aged composite restorations provided favorable results. Surface conditioning of existing restorations may eliminate the necessity of removing aged composite restorations.
- 1 December 2011
- Vol. 13 (6) , 569-577
Effect of Static and Cyclic Loading on Ceramic Laminate Veneers Adhered to Teeth with and Without Aged Composite Restorations
Existing composite restorations on teeth are often remade prior to the cementation of fixed dental prostheses. The aim of this study was to evaluate the effect of static and cyclic loading on ceramic laminate veneers adhered to aged resin composite restorations. Eighty sound maxillary incisors were collected and randomly divided into four groups: group 1: control group, no restorations; group 2: two Class III restorations; group 3: two Class IV restorations; group 4: complete composite substrate. Standard composite restorations were made using a microhybrid resin composite (Anterior Shine). Restored teeth were subjected to thermocycling (6000 cycles). Window preparations were made on the labial surface of the teeth for ceramic laminate fabrication (Empress II). Teeth were conditioned using an etch-and-rinse system. Existing composite restorations representing the aged composites were silica coated (CoJet) and silanized (ESPE-Sil). Ceramic laminates were cemented using a bis-GMA-based cement (Variolink Veneer). The specimens were randomly divided into two groups and were subjected to either static (groups 1a, 2a, 3a, 4a) or cyclic loading (groups 1b, 2b, 3b, 4b). Failure type and location after loading were classified. Data were analyzed using one-way ANOVA and Tukey's test. Significantly higher fracture strength was obtained in group 4 (330 ± 81 N) compared to the controls in group 1 (179 ± 120 N) (one-way ANOVA, p < 0.05). Group 1b survived a lower mean number of cyclic loads (672,820 cycles) than teeth of groups 2b to 4b (846x103 to 873x103 cycles). Failure type evaluation after the fracture test showed predominantly adhesive failures between dentin and cement, but after cyclic loading, more cohesive fractures in the ceramic were seen. Ceramic laminate veneers bonded to conditioned aged composite restorations provided favorable results. Surface conditioning of existing restorations may eliminate the necessity of removing aged composite restorations.
- Open Access
- 1 October 2010
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 18 (5) , 477-481
The adhesive system and root canal region do not influence the degree of conversion of dual resin cement
The aim of this study was to evaluate the influence of two adhesive systems and the post space region on the degree of conversion of dual resin cement and its bond strength to root dentin. One three-step etch-andrinse (All-bond 2, Bisco) and another one-step self-etch (Xeno III, Dentsply) adhesive systems were applied on 20 (n=10) crownless bovine incisors, at 12-mm-deep post space preparation, and a fiber post (DT Light Post, Bisco) was cemented using a dual cure resin cement (Duo-Link, Bisco). Three transverse sections (3 mm) were obtained, being one from each study region (cervical, middle and apical). The degree of conversion of the dual cure resin cement was determined by a micro-Raman spectrometer. The data (%) were submitted to repeated-measures analysis of variance and Tukey's test (p<0.05). For both groups, the degree of conversion means (%) (All bond 2cervical = 69.3; All bond 2middle = 55.1; All bond 2apical= 56; Xeno IIIcervical = 68.7; Xeno IIImiddle = 68.8; Xeno IIIapical = 54.3) were not significantly different along the post space regions (p<0.05). Neither the adhesive nor the post space region influenced the degree of conversion of the cement layer.
- 1 October 2010
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 18 (5) , 477-481
Open AccessThe adhesive system and root canal region do not influence the degree of conversion of dual resin cement
The aim of this study was to evaluate the influence of two adhesive systems and the post space region on the degree of conversion of dual resin cement and its bond strength to root dentin. One three-step etch-andrinse (All-bond 2, Bisco) and another one-step self-etch (Xeno III, Dentsply) adhesive systems were applied on 20 (n=10) crownless bovine incisors, at 12-mm-deep post space preparation, and a fiber post (DT Light Post, Bisco) was cemented using a dual cure resin cement (Duo-Link, Bisco). Three transverse sections (3 mm) were obtained, being one from each study region (cervical, middle and apical). The degree of conversion of the dual cure resin cement was determined by a micro-Raman spectrometer. The data (%) were submitted to repeated-measures analysis of variance and Tukey's test (p<0.05). For both groups, the degree of conversion means (%) (All bond 2cervical = 69.3; All bond 2middle = 55.1; All bond 2apical= 56; Xeno IIIcervical = 68.7; Xeno IIImiddle = 68.8; Xeno IIIapical = 54.3) were not significantly different along the post space regions (p<0.05). Neither the adhesive nor the post space region influenced the degree of conversion of the cement layer.
- 2 August 2010
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 22 (4) , 262-268
Bond Strength of Two Resin Cements on Dentin Using Different Cementation Strategies
This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step "etch-and-rinse" technique. The null hypothesis was that the "etch-and-rinse" adhesive system would generate higher bond strengths than the self-etching adhesives. Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 "etch-and-rinse" adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 x 5 x 4 mm), the specimens were stored in water (37 degrees C, 24 hours), and sectioned to obtain beams (+/-1 mm(2) of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (alpha = 0.05). Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The "etch-and-rinse" adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 +/- 10.6; G4: 33.0 +/- 8.9) compared to the self-etching adhesive systems (G1: 19.8 +/- 6.6; G3: 17.8 +/- 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used. Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step "etch-and-rinse" adhesive resulted in significantly higher bond strength for both resin cements on dentin. Dual polymerized resin cements tested could deliver higher bond strength to dentin in combination with "etch-and-rinse" adhesive systems as opposed to their use in combination with self-etching adhesives.
- 2 August 2010
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 22 (4) , 262-268
Bond Strength of Two Resin Cements on Dentin Using Different Cementation Strategies
This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step "etch-and-rinse" technique. The null hypothesis was that the "etch-and-rinse" adhesive system would generate higher bond strengths than the self-etching adhesives. Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 "etch-and-rinse" adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 x 5 x 4 mm), the specimens were stored in water (37 degrees C, 24 hours), and sectioned to obtain beams (+/-1 mm(2) of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (alpha = 0.05). Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The "etch-and-rinse" adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 +/- 10.6; G4: 33.0 +/- 8.9) compared to the self-etching adhesive systems (G1: 19.8 +/- 6.6; G3: 17.8 +/- 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used. Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step "etch-and-rinse" adhesive resulted in significantly higher bond strength for both resin cements on dentin. Dual polymerized resin cements tested could deliver higher bond strength to dentin in combination with "etch-and-rinse" adhesive systems as opposed to their use in combination with self-etching adhesives.
- 12 November 2009
- Vol. 57 (4) , 350-4
Durability of the bond strength of self-adhesive resin cements to human dentin.
This study subjected two self-adhesive resin cements and two conventional resin cements to dry and aging conditions, to compare their microtensile bond strengths (microTBS) to dentin. Using four different luting systems (n = 10), 40 composite resin blocks (each 5 x 5 x 4 mm) were cemented to flat human crown dentin surfaces. The specimens were stored in water for 24 hours (37 degrees C), at which point each specimen was sectioned along two axes to obtain beams that were divided randomly into two groups: dry samples, which were tested immediately, and samples that were subjected to accelerated aging conditions (12,000 thermocycles followed by storage for 150 days). The microTBS results were affected significantly by the luting system used (P < 0.0001). Only the microTBS of Rely-X Unicem was reduced significantly after aging; the microTBS remained stable or increased for the other self-adhesive resin cement and the two conventional cements.
- 12 November 2009
- Vol. 57 (4) , 350-4
Durability of the bond strength of self-adhesive resin cements to human dentin.
This study subjected two self-adhesive resin cements and two conventional resin cements to dry and aging conditions, to compare their microtensile bond strengths (microTBS) to dentin. Using four different luting systems (n = 10), 40 composite resin blocks (each 5 x 5 x 4 mm) were cemented to flat human crown dentin surfaces. The specimens were stored in water for 24 hours (37 degrees C), at which point each specimen was sectioned along two axes to obtain beams that were divided randomly into two groups: dry samples, which were tested immediately, and samples that were subjected to accelerated aging conditions (12,000 thermocycles followed by storage for 150 days). The microTBS results were affected significantly by the luting system used (P < 0.0001). Only the microTBS of Rely-X Unicem was reduced significantly after aging; the microTBS remained stable or increased for the other self-adhesive resin cement and the two conventional cements.
- 1 March 2009
- Published by Operative Dentistry in Operative Dentistry
- Vol. 34 (2) , 211-216
Effect of Acid Neutralization and Mechanical Cycling on the Microtensile Bond Strength of Glass-ceramic Inlays
SUMMARY: Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried. The specimens were divided into two groups (N=20): 1–without neutralization; 2–with neutralization. All the restorations were silanized and adhesively cemented (self-curing and self-etching luting composite system, Multilink). Ten premolars from each group were submitted to mechanical cycling (1,400,000 cycles, 50N, 37°C). After cycling, the samples were sectioned to produce non-trimmed beam specimens (vestibular dentin—restoration—lingual dentin set), which were submitted to microtensile testing. Results: Bond strength was significantly affected by the surface treatment (p neutralization) and mechanical cycling (p cycling) (2-way ANOVA and Tukey test, alpha=.05). Conclusion: Hydrofluoric acid precipitate neutralization appears to significantly damage the resin bond to glass-ceramic and should not be recommended. The clinical simulation of the specimens, by using mechanical cycling, is important when evaluating the ceramic-dentin bond.
- 1 March 2009
- Published by Operative Dentistry in Operative Dentistry
- Vol. 34 (2) , 211-216
Effect of Acid Neutralization and Mechanical Cycling on the Microtensile Bond Strength of Glass-ceramic Inlays
SUMMARY: Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried. The specimens were divided into two groups (N=20): 1–without neutralization; 2–with neutralization. All the restorations were silanized and adhesively cemented (self-curing and self-etching luting composite system, Multilink). Ten premolars from each group were submitted to mechanical cycling (1,400,000 cycles, 50N, 37°C). After cycling, the samples were sectioned to produce non-trimmed beam specimens (vestibular dentin—restoration—lingual dentin set), which were submitted to microtensile testing. Results: Bond strength was significantly affected by the surface treatment (p neutralization) and mechanical cycling (p cycling) (2-way ANOVA and Tukey test, alpha=.05). Conclusion: Hydrofluoric acid precipitate neutralization appears to significantly damage the resin bond to glass-ceramic and should not be recommended. The clinical simulation of the specimens, by using mechanical cycling, is important when evaluating the ceramic-dentin bond.
- Open Access
- 1 September 2008
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 22 (3) , 264-269
Adhesive cementation of zirconia posts to root dentin: evaluation of the mechanical cycling effect
This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.
- 1 September 2008
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 22 (3) , 264-269
Open AccessAdhesive cementation of zirconia posts to root dentin: evaluation of the mechanical cycling effect
This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.