AMAlan W. McInnes

Alan W. McInnes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alan W. McInnes has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Michael A. Burnstine

    1 shared publication
  • Steven C. Dresner

    Eyesthetica Oculofacial and Cosmetic Surgical Associates, and †Department of Ophthalmology, University of Southern California, Keck School of Medicine, Santa Monica, California, U.S.A.

    1 shared publication

Latest Publications

  • Using the Inferior Oblique Muscle to Augment Implant Coverage in Enucleation Surgery

    by Alan W. McInnes, Steven C. Dresner

    Purpose: We present a technique modification for enucleation surgery that may decrease implant exposure or extrusion by using native tissue to reinforce the implant at the most susceptible area, specifically the anterior-most aspect. Methods: An enucleation procedure is performed, and an implant is placed into the orbit. The horizontal rectus muscles are attached to the implant, and the vertical rectus muscles are attached directly to the horizontal muscles. The inferior oblique muscle is then spread over the anterior implant surface and sutured to the superior rectus and lateral rectus muscles. Results: 15 patients underwent this procedure, with implantation of an SST porous polyethylene implant. The mean follow-up interval was 18 months with a range of 4–33 months. One patient suffered an implant exposure, and one experienced a post-operative orbital hemorrhage. Two patients required blepharoptosis surgery to achieve eyelid symmetry. Conclusions: This retrospective series demonstrates the potential usefulness of the inferior oblique muscle to augment coverage of the orbital implant. Reinforcement of the anterior surface of the implant with vascularized tissue may improve the integrity and strength of the tissues anterior to the implant, and thereby reduce the likelihood of implant exposure.


  • White-Eyed Medial Wall Orbital Blowout Fracture

    by Alan W. McInnes, Michael A. Burnstine

    The white-eyed orbital floor blowout fracture is most commonly seen in children and adolescents. The orbital floor is the most common fracture location with entrapment of inferior orbital contents and/or the inferior rectus muscle in a "trapdoor" fashion. Other sites may also be fractured either simultaneous to the floor or in isolation. The authors describe an isolated orbital medial wall fracture with entrapment of the medial rectus muscle in an adolescent and discuss treatment options.