Using the Inferior Oblique Muscle to Augment Implant Coverage in Enucleation Surgery
Authors:
- 1 January 2011
- journal article
- surgical technique
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 27 (1) , 52-54
Abstract
Purpose: We present a technique modification for enucleation surgery that may decrease implant exposure or extrusion by using native tissue to reinforce the implant at the most susceptible area, specifically the anterior-most aspect. Methods: An enucleation procedure is performed, and an implant is placed into the orbit. The horizontal rectus muscles are attached to the implant, and the vertical rectus muscles are attached directly to the horizontal muscles. The inferior oblique muscle is then spread over the anterior implant surface and sutured to the superior rectus and lateral rectus muscles. Results: 15 patients underwent this procedure, with implantation of an SST porous polyethylene implant. The mean follow-up interval was 18 months with a range of 4–33 months. One patient suffered an implant exposure, and one experienced a post-operative orbital hemorrhage. Two patients required blepharoptosis surgery to achieve eyelid symmetry. Conclusions: This retrospective series demonstrates the potential usefulness of the inferior oblique muscle to augment coverage of the orbital implant. Reinforcement of the anterior surface of the implant with vascularized tissue may improve the integrity and strength of the tissues anterior to the implant, and thereby reduce the likelihood of implant exposure.Keywords
This publication has 7 references indexed in Scilit:
- Porous Orbital Implants in Enucleation: A Systematic ReviewSurvey of Ophthalmology, 2007
- The Smooth Surface Tunnel Porous Polyethylene Enucleation ImplantOphthalmic Surgery, Lasers and Imaging Retina, 2004
- Orbital implants in enucleation surgeryOphthalmology, 2003
- The Porous Polyethylene (Medpor) Spherical Orbital ImplantOphthalmic Plastic & Reconstructive Surgery, 2003
- Inferior oblique muscle location after enucleation and eviscerationAmerican Journal of Ophthalmology, 2001
- Exposure Rates of Wrapped and Unwrapped Orbital Implants Following EnucleationOphthalmic Plastic & Reconstructive Surgery, 2001
- Coralline Hydroxyapatite as an Ocular ImplantOphthalmology, 1991