Stefan Puchner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Stefan Puchner has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Aljoscha Rastan
Universitaets-Herzzentrum Freiburg-Bad Krozingen
2 shared publications - Florian Wolf
Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria
2 shared publications Johannes Lammer
Department of Radiology, Medical University of Vienna, Vienna General Hospital, Vienna, Austria
2 shared publications- Johannes Lammer
The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria,
2 shared publications - Klaus Armin Hausegger
Klinikum Klagenfurt
2 shared publications - Manfred Gschwendtner
Elisabethinen Hospital
2 shared publications
Latest Publications
- 1 December 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 133, 109402
Deep learning analysis provides accurate COVID-19 diagnosis on chest computed tomography
- 1 December 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 133, 109402
Deep learning analysis provides accurate COVID-19 diagnosis on chest computed tomography
- 3 September 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (1) , 91-100
Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography
To define the optimal systolic phase for dual-source computed tomography angiography using an absolute reconstruction delay time after the R–R interval based on the coronary artery motion, we analyzed images reconstructed between 200 and 420 miliseconds (ms) after the R wave at 20 ms increments in 21 patients. Based on the American Heart Association coronary segmentation guidelines, the origin of six coronary artery landmarks (RCA, AM1, PDA, LM, OM1, and D2) were selected to calculate the coronary artery motion velocity. The velocity of the given landmark was defined as the quotient of the route and the length of the time interval. The x, y and z-coordinates of the selected landmark were recorded, and were used for the calculation of the 3D route of coronary artery motion by using a specific equation. Differences in velocities were assessed by analysis of variance for repeated measures; Bonferroni post hoc tests were used for multiple pair wise comparisons. 1488 landmarks were measured (6 locations at 12 systolic time points) in 21 patients and were analyzed. The mean values of the minimum velocities were calculated separately for each heart rate group (i.e. 80 bpm). The mean lowest coronary artery velocities in each segment occurred in the middle period of each time interval of the acquired systolic phase i.e. 280–340 ms. No differences were found in the minimal coronary artery velocities between the three HR groups, with the exception of the AM1 branch (p = 0.00495) between 80 bpm (p = 0.03), and at HRs of 65–80 versus >80 bpm (p = 0.006). During an absolute delay of 200–420 ms after the R-wave, the ideal reconstruction interval varies significantly among coronary artery segments. Decreased velocities occur between 280 to 340 ms. Therefore a narrow range of systolic intervals, rather than a single phase, should be acquired.
- 3 September 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (1) , 91-100
Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography
To define the optimal systolic phase for dual-source computed tomography angiography using an absolute reconstruction delay time after the R–R interval based on the coronary artery motion, we analyzed images reconstructed between 200 and 420 miliseconds (ms) after the R wave at 20 ms increments in 21 patients. Based on the American Heart Association coronary segmentation guidelines, the origin of six coronary artery landmarks (RCA, AM1, PDA, LM, OM1, and D2) were selected to calculate the coronary artery motion velocity. The velocity of the given landmark was defined as the quotient of the route and the length of the time interval. The x, y and z-coordinates of the selected landmark were recorded, and were used for the calculation of the 3D route of coronary artery motion by using a specific equation. Differences in velocities were assessed by analysis of variance for repeated measures; Bonferroni post hoc tests were used for multiple pair wise comparisons. 1488 landmarks were measured (6 locations at 12 systolic time points) in 21 patients and were analyzed. The mean values of the minimum velocities were calculated separately for each heart rate group (i.e. 80 bpm). The mean lowest coronary artery velocities in each segment occurred in the middle period of each time interval of the acquired systolic phase i.e. 280–340 ms. No differences were found in the minimal coronary artery velocities between the three HR groups, with the exception of the AM1 branch (p = 0.00495) between 80 bpm (p = 0.03), and at HRs of 65–80 versus >80 bpm (p = 0.006). During an absolute delay of 200–420 ms after the R-wave, the ideal reconstruction interval varies significantly among coronary artery segments. Decreased velocities occur between 280 to 340 ms. Therefore a narrow range of systolic intervals, rather than a single phase, should be acquired.
- 17 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (3) , 779-780
Erratum to: Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial
- 17 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (3) , 779-780
Erratum to: Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial
- 5 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 25-32
Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial
The hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only. A prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN® Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN® versus 17.3 ± 6.6 cm in the BMS group. The 24-month primary patency rates in the VIABAHN® and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN® versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN® versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN® versus the BMS group, respectively. At 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244).
- 5 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 25-32
Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial
The hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only. A prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN® Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN® versus 17.3 ± 6.6 cm in the BMS group. The 24-month primary patency rates in the VIABAHN® and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN® versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN® versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN® versus the BMS group, respectively. At 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244).
- 1 June 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (6) , 1353-1359
Confident non-invasive diagnosis of pseudolesions of the liver using diffusion-weighted imaging at 3T MRI
- 1 June 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (6) , 1353-1359
Confident non-invasive diagnosis of pseudolesions of the liver using diffusion-weighted imaging at 3T MRI
- 1 June 2009
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 16 (3) , 336-342
Multidetector CTA in the Quantification of Internal Carotid Artery Stenosis: Value of Different Reformation Techniques and Axial Source Images Compared With Selective Carotid Arteriography
Purpose: To evaluate the role of 4 different reformation techniques and axial images from multidetector computed tomographic angiography (MDCTA) versus selective carotid arteriography (SCA) in patients with internal carotid artery (ICA) stenosis. Methods: Imaging studies from 50 patients (43 men; mean age 70.3±8.0 years, range 51– 85) with known cerebrovascular disease who underwent MDCTA and SCA in a single university hospital were retrospectively analyzed. Axial images, multiplanar reformation (MPR), curved planar reformation (CPR), volume rendering threshold (VRT), and virtual angioscopy (VA) images were reviewed by 2 independent observers who were blinded to the results of SCA, which served as the gold standard. The degree of stenosis was categorized as 0%–49%, 50%–69%, or 70%–99%; a stenosis >70% was considered as hemodynamically significant. Results: Thirty-four hemodynamically significant stenoses were identified on SCA. The agreement with SCA images was good for both observers using axial CT images (κ=0.89 for observer 1 and 0.88 for observer 2); corresponding results for MPR and CPR were κ=0.91 and 0.92 for observer 1 and 0.88 and 0.91 for observer 2, respectively. VRT (κ=0.72 for observer 1 and 0.66 for observer 2) and VA (κ=0.74 for observer 1 and 0.70 for observer 2) showed a slightly inferior correlation with SCA images. Sensitivities for reformations and axial CT images were 100% each; corresponding specificities ranged from 85% to 95%. Conclusion: Axial images as well as all 4 reformation techniques agreed well with SCA in the grading of ICA stenosis.
- 1 June 2009
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 16 (3) , 336-342
Multidetector CTA in the Quantification of Internal Carotid Artery Stenosis: Value of Different Reformation Techniques and Axial Source Images Compared With Selective Carotid Arteriography
Purpose: To evaluate the role of 4 different reformation techniques and axial images from multidetector computed tomographic angiography (MDCTA) versus selective carotid arteriography (SCA) in patients with internal carotid artery (ICA) stenosis. Methods: Imaging studies from 50 patients (43 men; mean age 70.3±8.0 years, range 51– 85) with known cerebrovascular disease who underwent MDCTA and SCA in a single university hospital were retrospectively analyzed. Axial images, multiplanar reformation (MPR), curved planar reformation (CPR), volume rendering threshold (VRT), and virtual angioscopy (VA) images were reviewed by 2 independent observers who were blinded to the results of SCA, which served as the gold standard. The degree of stenosis was categorized as 0%–49%, 50%–69%, or 70%–99%; a stenosis >70% was considered as hemodynamically significant. Results: Thirty-four hemodynamically significant stenoses were identified on SCA. The agreement with SCA images was good for both observers using axial CT images (κ=0.89 for observer 1 and 0.88 for observer 2); corresponding results for MPR and CPR were κ=0.91 and 0.92 for observer 1 and 0.88 and 0.91 for observer 2, respectively. VRT (κ=0.72 for observer 1 and 0.66 for observer 2) and VA (κ=0.74 for observer 1 and 0.70 for observer 2) showed a slightly inferior correlation with SCA images. Sensitivities for reformations and axial CT images were 100% each; corresponding specificities ranged from 85% to 95%. Conclusion: Axial images as well as all 4 reformation techniques agreed well with SCA in the grading of ICA stenosis.
- 12 June 2008
- Published by Springer Nature in Neuroradiology
- Vol. 50 (10) , 849-853
Assessment of intima-media thickness of carotid arteries: evaluation of an automated computer software
The aim of this study was to evaluate the feasibility and accuracy of commercially available software directly implemented on the ultrasound scanner for automated measurement of the intima-media thickness (IMT) of the common carotid artery on source images.
- 12 June 2008
- Published by Springer Nature in Neuroradiology
- Vol. 50 (10) , 849-853
Assessment of intima-media thickness of carotid arteries: evaluation of an automated computer software
The aim of this study was to evaluate the feasibility and accuracy of commercially available software directly implemented on the ultrasound scanner for automated measurement of the intima-media thickness (IMT) of the common carotid artery on source images.