Ewald Niehuis
Ewald Niehuis has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
D. Rading
ION‐TOF GmbH Heisenbergstr. 15 D‐48149 Muenster Germany
2 shared publicationsR. Kersting
TASCON GmbH Heisenbergstr. 15 D‐48149 Muenster Germany
2 shared publicationsRudolf Moellers
IONTOF GmbH, Muenster, Germany
2 shared publicationsAnja Henss
Physikalisch-Chemisches Institut, Justus-Liebig University Giessen, Germany
1 shared publicationB. Hagenhoff
TASCON GmbH, Heisenbergstr. 15, 48149 Muenster, Germany
1 shared publicationDerk Rading
ION‐TOF GmbH Heisenbergstr. 15 48149 Muenster Germany
1 shared publication
Latest Publications
- 1 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1026-1027
TOF-SIMS Analysis with High Lateral and High Mass Resolution in Parallel
- 1 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1026-1027
TOF-SIMS Analysis with High Lateral and High Mass Resolution in Parallel
- 25 November 2014
- Published by Wiley in Surface and Interface Analysis
- Vol. 46 (S1) , 70-73
Dual beam depth profiling of organic materials: assessment of capabilities and limitations
With the advent of large argon cluster beams, organic materials can be sputtered without the accumulation of radiation damage. The dual beam mode with a Bi cluster analysis beam is successfully applied to depth profiling and 3D analysis of organic materials providing both high‐depth resolution and high‐lateral resolution. For the analysis of very small sample volumes, it is desirable that a rather large fraction of the material is consumed by the analysis beam and contributes to the analytical signal. However, at higher analysis beam sputter rates, the radiation damage by the Bi clusters can become quite severe leading to a molecular ion signal decay with depth. In this paper, we investigate the conditions for the optimum use of the sample material in the dual beam mode using the Irganox delta layer structure introduced by NPL (National Physical Laboratory (UK)). A model that describes the dual beam mode and allows calculating the intact area fraction in the steady state is presented. Yield volumes and damage volumes are determined for Bi 3 + and Bi 5 ++ as well as the useful sample fraction that contributes to the molecular ion signal. We will compare the results to the depth profiling with C 60 and Ar clusters in a single DC beam mode. Copyright © 2014 John Wiley & Sons, Ltd.
- 25 November 2014
- Published by Wiley in Surface and Interface Analysis
- Vol. 46 (S1) , 70-73
Dual beam depth profiling of organic materials: assessment of capabilities and limitations
With the advent of large argon cluster beams, organic materials can be sputtered without the accumulation of radiation damage. The dual beam mode with a Bi cluster analysis beam is successfully applied to depth profiling and 3D analysis of organic materials providing both high‐depth resolution and high‐lateral resolution. For the analysis of very small sample volumes, it is desirable that a rather large fraction of the material is consumed by the analysis beam and contributes to the analytical signal. However, at higher analysis beam sputter rates, the radiation damage by the Bi clusters can become quite severe leading to a molecular ion signal decay with depth. In this paper, we investigate the conditions for the optimum use of the sample material in the dual beam mode using the Irganox delta layer structure introduced by NPL (National Physical Laboratory (UK)). A model that describes the dual beam mode and allows calculating the intact area fraction in the steady state is presented. Yield volumes and damage volumes are determined for Bi 3 + and Bi 5 ++ as well as the useful sample fraction that contributes to the molecular ion signal. We will compare the results to the depth profiling with C 60 and Ar clusters in a single DC beam mode. Copyright © 2014 John Wiley & Sons, Ltd.
- 9 July 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 158-162
Analysis of organic multilayers and 3D structures using Ar cluster ions
Ar cluster sputtering of organic multilayers such as organic light‐emitting diode model structures and Irganox delta layers is studied with time‐of‐flight secondary ion mass spectroscopy in the dual beam mode. Results for sputtering yield volumes and depth resolution are presented for Ar clusters with sizes from 500 to 5000 atoms in the energy range from 2.5 to 20 keV. The sputtering yield volume shows a linear dependence on the energy per atom for all materials in this study with a material‐dependent threshold below 1 eV/atom. The sputtering yield volume at a given energy per atom increases with the cluster size. At constant beam energies, the sputtering yield volume decreases slightly with increasing cluster size. The depth resolution is investigated for the two model systems as a function of energy and cluster size, and it will be shown that the depth resolution depends mainly on the sample roughening. The depth resolution is approximately proportional to the depth of the impact crater at a given cluster size and energy. The optimum depth resolution achieved is in the range of 4–5 nm and is fairly constant with depth. At very low energies per atom close to the threshold energy, ripple formation is observed that leads to a fast degradation of the depth resolution with depth. This can be completely eliminated by fast sample rotation. Finally, the perspective of 3D analysis of organic devices with high depth resolution in the dual beam mode will be discussed. Copyright © 2012 John Wiley & Sons, Ltd.
- 9 July 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 158-162
Analysis of organic multilayers and 3D structures using Ar cluster ions
Ar cluster sputtering of organic multilayers such as organic light‐emitting diode model structures and Irganox delta layers is studied with time‐of‐flight secondary ion mass spectroscopy in the dual beam mode. Results for sputtering yield volumes and depth resolution are presented for Ar clusters with sizes from 500 to 5000 atoms in the energy range from 2.5 to 20 keV. The sputtering yield volume shows a linear dependence on the energy per atom for all materials in this study with a material‐dependent threshold below 1 eV/atom. The sputtering yield volume at a given energy per atom increases with the cluster size. At constant beam energies, the sputtering yield volume decreases slightly with increasing cluster size. The depth resolution is investigated for the two model systems as a function of energy and cluster size, and it will be shown that the depth resolution depends mainly on the sample roughening. The depth resolution is approximately proportional to the depth of the impact crater at a given cluster size and energy. The optimum depth resolution achieved is in the range of 4–5 nm and is fairly constant with depth. At very low energies per atom close to the threshold energy, ripple formation is observed that leads to a fast degradation of the depth resolution with depth. This can be completely eliminated by fast sample rotation. Finally, the perspective of 3D analysis of organic devices with high depth resolution in the dual beam mode will be discussed. Copyright © 2012 John Wiley & Sons, Ltd.
- 19 January 2011
- Published by Wiley in Surface and Interface Analysis
- Vol. 43 (1-2) , 204-206
MCs + depth profiling using cluster primary ions
The emission of Cs + and MCs + ions from various materials like Si, Al, Ti, Fe and Zn under Bi 1 and C 60 cluster bombardment is studied in the TOF‐SIMS dual‐beam mode with low‐energy Cs sputtering. High yield enhancements up to 2000 are observed for C 60 primary ions, in particular for materials with low sputter yields at high Cs surface concentration. The results indicate a significant improvement in the Cs + ionization probabilities for C 60 in the case of a work function smaller than the ionization potential of Cs. High, and rather uniform MCs + yields, can be achieved for the different materials, and depth profiling using cluster primary ions has a significant potential for quantitative SIMS analysis. Copyright © 2010 John Wiley & Sons, Ltd.
- 19 January 2011
- Published by Wiley in Surface and Interface Analysis
- Vol. 43 (1-2) , 204-206
MCs + depth profiling using cluster primary ions
The emission of Cs + and MCs + ions from various materials like Si, Al, Ti, Fe and Zn under Bi 1 and C 60 cluster bombardment is studied in the TOF‐SIMS dual‐beam mode with low‐energy Cs sputtering. High yield enhancements up to 2000 are observed for C 60 primary ions, in particular for materials with low sputter yields at high Cs surface concentration. The results indicate a significant improvement in the Cs + ionization probabilities for C 60 in the case of a work function smaller than the ionization potential of Cs. High, and rather uniform MCs + yields, can be achieved for the different materials, and depth profiling using cluster primary ions has a significant potential for quantitative SIMS analysis. Copyright © 2010 John Wiley & Sons, Ltd.