Latest Publications
- 1 November 2009
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 82 (983) , 920-929
Reduction of dose to the female breast as a result of spectral optimisation for high-contrast thoracic CT imaging: a phantom study
Various approaches to reduce dose to the female breast in thoracic CT have been investigated. We evaluated the potential for reduction of dose to the breast by optimal choice of the X-ray spectra. The effect of X-ray energy variation on dose to the female breast in thoracic CT was examined by simulations and measurements of image contrast, image noise and radiation dose. A standard thorax phantom was used with various extension rings and breasts added and the following contrast inserts: iodine, calcium hydroxyapatite and a pure soft-tissue density difference. Three-dimensional dose distributions were determined by a validated Monte Carlo tool. The contrast-to-noise ratio per unit dose (CNRD) was determined for tube voltages of 40-200 kV by simulations and for 60-140 kV by measurements on a clinical CT scanner. CNRD curves did not show significant variations in soft-tissue density contrast, but considerable optimisation potential for iodine and skeletal imaging at reduced energies. Exact values depend on the patient's cross-section and X-ray spectrum. For example, reducing the tube voltage from 120 kV to 80 kV on the scanner reduced dose to the female breast typically by 50% without deterioration of the CNR. This method exceeds the dose reduction potential of other measures. We conclude that tube voltages in thoracic CT can be lowered for contrast medium and skeletal imaging without affecting the CNR but with a significant decrease in dose to the female breast.
- 1 November 2009
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 82 (983) , 920-929
Reduction of dose to the female breast as a result of spectral optimisation for high-contrast thoracic CT imaging: a phantom study
Various approaches to reduce dose to the female breast in thoracic CT have been investigated. We evaluated the potential for reduction of dose to the breast by optimal choice of the X-ray spectra. The effect of X-ray energy variation on dose to the female breast in thoracic CT was examined by simulations and measurements of image contrast, image noise and radiation dose. A standard thorax phantom was used with various extension rings and breasts added and the following contrast inserts: iodine, calcium hydroxyapatite and a pure soft-tissue density difference. Three-dimensional dose distributions were determined by a validated Monte Carlo tool. The contrast-to-noise ratio per unit dose (CNRD) was determined for tube voltages of 40-200 kV by simulations and for 60-140 kV by measurements on a clinical CT scanner. CNRD curves did not show significant variations in soft-tissue density contrast, but considerable optimisation potential for iodine and skeletal imaging at reduced energies. Exact values depend on the patient's cross-section and X-ray spectrum. For example, reducing the tube voltage from 120 kV to 80 kV on the scanner reduced dose to the female breast typically by 50% without deterioration of the CNR. This method exceeds the dose reduction potential of other measures. We conclude that tube voltages in thoracic CT can be lowered for contrast medium and skeletal imaging without affecting the CNR but with a significant decrease in dose to the female breast.
- 15 April 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (8) , 1674-1682
Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations
We evaluated the potential for reduction of dose to the female breast in computed tomography (CT) of the thorax by using three different techniques: bismuth shielding, partial CT scanning and tube-current modulation (TCM). Measurements and simulations of dose and image quality were performed for a 64-slice CT system using a semi-anthropomorphic thorax phantom with breasts added. Three-dimensional dose distributions were calculated by Monte Carlo (MC) methods. Noise was determined by measurements and simulations. Bismuth shielding resulted in a dose reduction of about 50% for the breast, noise increased up to 40% and image quality was impaired by artifacts. In partial CT scans, not irradiating the breasts directly, dose to the breasts was reduced typically by 50%. To sustain a constant noise level, an increase of irradiation in the anteroposterior position resulted in a higher dose to the spine. Reduction of dose to the breasts of about 10% was achieved with TCM; distribution of noise was homogeneous and image quality uniform. Reduction of dose to the female breast was achieved by using all adapted CT methods. Bismuth shielding may compromise image quality, increase noise level and introduce streak artifacts. Partial and TCM examinations reduced dose to the breast without influencing image quality.
- 15 April 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (8) , 1674-1682
Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations
We evaluated the potential for reduction of dose to the female breast in computed tomography (CT) of the thorax by using three different techniques: bismuth shielding, partial CT scanning and tube-current modulation (TCM). Measurements and simulations of dose and image quality were performed for a 64-slice CT system using a semi-anthropomorphic thorax phantom with breasts added. Three-dimensional dose distributions were calculated by Monte Carlo (MC) methods. Noise was determined by measurements and simulations. Bismuth shielding resulted in a dose reduction of about 50% for the breast, noise increased up to 40% and image quality was impaired by artifacts. In partial CT scans, not irradiating the breasts directly, dose to the breasts was reduced typically by 50%. To sustain a constant noise level, an increase of irradiation in the anteroposterior position resulted in a higher dose to the spine. Reduction of dose to the breasts of about 10% was achieved with TCM; distribution of noise was homogeneous and image quality uniform. Reduction of dose to the female breast was achieved by using all adapted CT methods. Bismuth shielding may compromise image quality, increase noise level and introduce streak artifacts. Partial and TCM examinations reduced dose to the breast without influencing image quality.