JSJohn L. Szarka

John L. Szarka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John L. Szarka has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of the early aberration reporting system (EARS) W2 methods to an adaptive threshold method

    by John L. Szarka, Linmin Gan, William H. Woodall

    In this paper we examine some of the methodologies implemented by the Centers for Disease Control and Prevention's (CDC) BioSense program. The program uses data from hospitals and public health departments to detect outbreaks using the Early Aberration Reporting System (EARS). The EARS method W2 allows one to monitor syndrome counts (W2count) from each source and the proportion of counts of a particular syndrome relative to the total number of visits (W2rate). We investigate the performance of these methods, which are designed using an empiric recurrence interval (RI), with simulated parametric data. Counts from the Poisson and negative binomial distributions are generated, and used to examine W2 properties. An adaptive threshold monitoring method is introduced based on fitting sample data to the above distributions, then converting the current value to a Z‐score through a p‐value. We compare the thresholds required to obtain given values of the RI for different sets of parameter values. We then simulate 1‐week outbreaks in our data and calculate the proportion of times these methods correctly signal an outbreak using Shewhart and exponentially weighted moving average (EWMA) charts. Our results indicate that the adaptive threshold method gives more consistent statistical performance across different parameter sets and amounts of baseline historical data used for computing the statistics. For the sensitivity analysis, the EWMA chart is superior to its Shewhart counterpart in nearly all cases and the adaptive threshold methods tend to outperform the W2 methods. Copyright © 2011 John Wiley & Sons, Ltd.


  • The Prediction Properties of Classical and Inverse Regression for the Simple Linear Calibration Problem

    by Peter A. Parker, G. Geoffrey Vining, Sara R. Wilson, John L. Szarka, Nels G. Johnson

    The calibration of measurement systems is a fundamental but understudied problem within industrial statistics. In the classical context of this problem, standards produced by the National Institute of Standards and Technology (NIST) are used in chemical, mechanical, electrical, and materials-engineering analyses. Often, applications cast into this calibration framework do not provide “gold standards” such as the standards provided by NIST. This paper considers the classical calibration approach, in which the experiment treats the standards as the regressor and the observed values as the response to calibrate the instrument. The analyst then must invert the resulting regression model in order to use the instrument to make actual measurements in practice. This paper compares this classical approach to inverse regression, which treats the standards as the response and the observed measurements as the regressor in the calibration experiment. Such an approach is intuitively appealing because it is simple and easily implemented in most software. However, it violates some of the basic regression assumptions. In this paper, we study the properties of classical and inverse regression applied to calibration problems, compare their performance, and provide guidance to practitioners.