NMNur Muhammad

Nur Muhammad

*This is an algorithmically generated author record based on publicly available information.

Nur Muhammad has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Low-Cost Innovative Sand Filtration System for Treatment of Drinking Water in Small Communities

    by Rajib Sinha, Nur Muhammad

    A low-cost innovative sand filter system was fabricated using 55-gallon drums and tested at the EPA T&E Facility in Cincinnati, Ohio. The sand fi |

  • Use of Biological and Non-Biological Surrogates for Evaluating Cryptosporidium Removal by Filtration

    by Nur Muhammad, Rajib Sinha, E. Radha Krishnan, Craig L. Patterson

    Water treatment plants are currently facing increasing challenges in monitoring Cryptosporidium in source and treated water because of complex analytical techniques and associated health risks. Surrogates may be easier to analyze than Cryptosporidium, but they must also be reliable and representative of results. Polystyrene Latex (PSL) beads of 2 – 3 μm size have been suggested by researchers as a potential non-biological surrogate for Cryptosporidium as it mimics the size and surface characteristics of the pathogen. Bacillus subtilis (B. subtilis) spores have also been suggested by researchers as a potential biological surrogate for Cryptosporidium because of their resistance to conventional disinfectants and abundance in surface water. Therefore, it is important to examine the surrogacy of PSL beads and B. subtilis spores based on filtration mechanisms. This paper summarizes the results of PSL beads, B. subtilis and Cryptosporidium challenge tests conducted on different package water treatment systems that include bag and cartridge units, membrane and granular media filtration units, and adsorptive systems with charged media. Analytical techniques and the accuracy of surrogate results are discussed and compared for various types of treatment units evaluated at EPA's Test and Evaluation Facility in Cincinnati, Ohio, and different field locations.

  • Evaluation of a Pour-Through Water Treatment Device for Use as Microbiological Purifier

    by Craig Patterson, Morris Waskar, Nur Muhammad, Rajib Sinha, E. Radha Krishnan, Nimish Shah

    The United States Environmental Protection Agency (EPA) Office of Research and Development has evaluated the performance of a Point-of-Use (POU) pour-through device designed for use in India, developing and emerging market (D&E) countries, and under emergency situations in the United States. In collaboration with the Unilever Research India, a series of microbial tests were conducted on a Unilever PureitTM microbiological purifier for household drinking water at the EPA's Test and Evaluation Facility in Cincinnati, Ohio. The PureitTM water treatment system is fed by gravity and combines the unit operations of physical filtration, chlorine disinfection, and carbon adsorption for treating drinking water. EPA evaluated the PureitTM device for removal of E. coli (as a surrogate for bacteria), and MS2 bacteriophage (as a surrogate for viruses). Results demonstrated that the PureitTM system achieved EPA requirements of a 6 log reduction of bacteria and a 4 log reduction of virus for a "Microbiological Purifier" throughout the design life of the device (∼ 2250 liters). The final polisher of the unit was capable of reducing the residual chlorine concentration to less than the EPA's 2 mg/L maximum limit for tap water.


  • Evaluation of Long-Term Performance of Point of Use (POU) Systems for Drinking Water Treatment

    by Nur Muhammad, Rajib Sinha, E. Radha Krishnan, Lee Heckman, Craig L. Patterson

    The U.S. Environmental Protection Agency (EPA) initiated a research program in 2008 at the EPA Test and Evaluation (T&E) Facility in Cincinnati, Ohio to evaluate the performance of various Point-of-Use (POU) treatment devices for providing drinking water in homes and transient non-community water systems, either routinely or as an emergency measure during accidental or intentional contamination events. This paper describes the results of the performance of two POU devices based on reverse osmosis (RO) technology. The POU devices were continuously operated for about 22 months (670 days) to evaluate their long-term performance and challenged with microbiological contaminants at different time intervals to evaluate continued treatment effectiveness. The microbiological contaminant challenge contaminants included E. coli, MS2 bacteriophage, B. subtilis and polystyrene latex (PSL) beads (evaluated as a non-biological surrogate for Cryptosporidium). The results of tests conducted to date show complete removal of the selected microorganisms and surrogates by the POU systems both at startup and after 22 months of operation. The two RO-based POU systems satisfied the Long-Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirements for Cryptosporidium removal. The POU devices performed favorably when compared to the reduction requirement of the EPA Guide Standard Protocol for Microbiological Water Purifiers (U.S. EPA, 1987), which is 6 log for bacteria and 4 log for viruses.

  • Laboratory and Field Evaluation of a Nanofilter Membrane to Remove Disinfection Byproduct Precursors and Microorganisms from Lake Water Sources Used for Drinking Water

    by Rajib Sinha, Nur Muhammad, Radha Krishnan, Anita Anderson, Craig Patterson, David Pearson

    Small community systems that use surface water as a source of drinking water are frequently faced with elevated levels of naturally-occurring organic matter (NOM) that are not removed by conventional filtration methods. These residual levels of NOM can then combine with chlorine used for disinfection and create disinfection byproducts (DBPs) that could potentially exceed the regulatory limit for various DBPs. Additional treatment for removal of these DBP compounds may be required for compliance with the requirements of the Safe Drinking Water Act (SDWA). The formation of DBPs can be prevented by removing NOM which act as DBP precursors. This paper presents the results of experiments conducted on two nanofilter membrane systems with a patented method for cleaning the membrane using a foam ball. The tests were conducted at the U.S. EPA Test & Evaluation (T&E) Facility (using dechlorinated potable water with the addition of humic acid to simulate NOM) and at a field site using lake water. The treatment system uses a tubular membrane with the ends connected to effectively form a single, long, membrane. A foam ball is periodically passed through the inside of the membrane by reversing the flow direction to scour the membrane surface and remove accumulated organic matter capable of fouling the membrane surface. This organic matter is then discharged by back-flushing the membrane. The effectiveness of the system in producing drinking water was gauged by measuring the turbidity, color, and organic content of the system inlet and outlet. Tests were also performed using the aerobic spore Bacillus subtilis (B. subtilis) as a surrogate for bacteria removal and MS2 bacteriophage as a surrogate for virus removal.


  • Evaluating a composite cartridge for small system drinking water treatment

    by Nur Muhammad, Rajib Sinha, Radha Krishnan, Craig L. Patterson, Roy C. Haught, Harold H. Harms, Rick Seville

    A pilot-scale evaluation was conducted at the U.S Environmental Protection Agency (EPA) Test & Evaluation (T&E) Facility in Cincinnati, Ohio, on a multi-layer, cartridge-based system that combines physical filtration with carbon adsorption and ultraviolet (UV) light disinfection to serve as a home-base water treatment security device against accidental or intentional contaminant events. The system was challenged with different levels of turbidity, a number of biological contaminants including Bacillus subtilis, Escherichia coli, MS2bacteriophage and Polystyrene Latex (PSL) beads as a surrogate for Cryptosporidium and a number of chemical contaminants including super-chlorination, methyl tertiary butyl ether (MTBE), water chlorination disinfection byproducts (DBPs) and diazinon. The results demonstrated that the performance of the system varies as a function of the specific contaminant or surrogate. The overall performance indicated the potential of the system to improve the quality and safety of household water and to serve as an additional treatment barrier in circumstances where there is little or no treatment or where the quality of treated water may have deteriorated during distribution. The results also demonstrated that B. subtilis spore can serve as a more conservative surrogate for Cryptosporidium than PSL beads.


  • Development of a Community Water Security Filtration System Using Composite Cartridges

    by Nur Muhammad, Rajib Sinha, E. Radha Krishnan, Craig L. Patterson, Roy C. Haught, Harold H. Harms, Rick Seville

    Under a Cooperative Research and Development Agreement (CRADA) established between the U.S. Environmental Protection Agency (EPA) and Harmsco, Inc., a prototype Community Water Security Filtration System for drinking water treatment using composite cartridges is being developed and tested at the EPA's Test & Evaluation (T&E) Facility in Cincinnati, Ohio. The filtration system incorporates a composite cartridge that combines physical pre-filtration with carbon adsorption and a cyst-rated final filter for removal of turbidity, specific chemical compounds, and some biological oocysts. The composite cartridge is then followed by ultraviolet (UV) light to provide short wave UV disinfection. The housing is constructed with a tangential inlet that induces a centrifugal motion to the water which aids filtratiom. The research has focused on optimizing the filtration media and housing configuration by testing the system using various biological surrogates and chemical compounds as contaminants. The current system configuration consists of a housing with two chambers; the upper chamber contains 8 (eight) composite cartridges for filtration, while the lower chamber contains six UV lamps for disinfection. Electrodes have been installed between the internal cartridge basket and the housing wall to provide an experimental electroseparation process to enhance particulate and pathogen removal and to determine if there is any pathogen cell disruption. Results of developmental tests conducted on single cartridges to optimize the composite cartridge media configuration show complete removal of Polystyrene Latex (PSL) beads (used as a non-biological surrogate for Cryptosporidium) which satisfies the Long Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirement of >3.0 log reduction of Cryptosporidium. Results of tests conducted on the 8-chamber full-scale unit show almost complete removal of MS2 bacteriophage as a surrogate for enteric virus satisfying the LT2ESWTR requirement of a 4-log reduction for viruses.

  • Evaluation of Point of Use (POU) Systems for the Removal of Microbiological Contaminants in Drinking Water

    by Rajib Sinha, Nur Muhammad, E. Radha Krishnan, Haishan Piao, Craig L. Patterson, Joseph Cotruvo

    As a final barrier before consumption, properly designed and operated Point-of-Use (POU) treatment systems are important for safe drinking water supplies. POU treatment devices have gained importance for protection against intentional or accidental contamination of drinking water supplies. The events of September 11, 2001 have further emphasized the importance of POU devices in this regard. This paper summarizes the results of pilot-scale studies that were conducted at the U.S. Environmental Protection Agency's (EPA's) Test and Evaluation (T&E) Facility in Cincinnati, Ohio, to evaluate the performance of three different POU systems for removing microbiological contaminants in drinking water. Two of these systems were based on filtration through electrostatically charged media and the third system incorporated a reverse osmosis (RO) membrane. The systems were challenged with a number of microbiological contaminants including Cryptosporidium, E. coli, MS2 bacteriophage, B. subtilis and polystyrene latex (PSL) beads (as a surrogate for Cryptosporidium). The results demonstrated that these POU systems were effective in removing the target biological contaminants in accordance with the standards presented in the U.S. EPA "Guide Standard and Protocol for Testing Microbiological Water Purifiers".


  • Development of a Water Security Filtration System for Whole House Water Supply

    by Nur Muhammad, Rajib Sinha, E. Radha Krishnan, Craig L. Patterson, Roy C. Haught, Harold H. Harms, Rick Seville

    The waterborne disease outbreaks have been a constant reminder of the critical importance of ensuring safe drinking water. Properly designed and operated public water systems, either large or small, are required to protect public health. This paper presents the results of tests conducted on a multi-layer cartridge based small system that combines physical filtration with chemical adsorption and ultraviolet light disinfection. The system was challenged with test water containing different levels of turbidity, a number of biological contaminants including B. subtilis, E. coli, MS2 bacteriophage and Polystyrene Latex (PSL) beads (as a surrogate for Cryptosporidium) and a number of chemical contaminants including methyl tert-butyl ether (MTBE), high chlorine concentrations, drinking water treatment disinfection byproducts (DBPs) including trihalomethanes and haloacetic acids, arsenic and diazinon. This paper benchmarks the baseline performance of the system in removing physical, biological and chemical contaminants and identifies the areas for further development. The applicability of the system as a home water security device was evaluated.


  • Assessment of a Point-of-Use Ultrafiltration System for Turbidity and Microbial Pathogen Removal

    by Craig L. Patterson, Aisha Tzillah, Nur Muhammad, Jack Duffie

    U.S. EPA's Office of Research and Development has been evaluating the performance of point-of-use (POU) devices designed for use in homes and small businesses for many years. In collaboration with the University of Cincinnati, a series of pilot-scale tests were conducted on a Matrix Membranes ultrafiltration (MMUF) system at the U.S. EPA Test and Evaluation Facility in Cincinnati, Ohio. The MMUF system operates at a low flow rate (< 2 gpm) and feed pressure (< 30 psi). The polyethersulfone (PES) membrane (2" x 21") is designed for high flux rates with inside-out operation. Membrane integrity tests require the injection of compressed air (10 psi) into the closed system to check for breakthrough or air bubbles in the membrane. The MMUF system requires back-flushing when the filtrate flow drops 25%. The chlorine resistant membrane consists of 500 hollow fibers with 0.8 mm inner diameter and 1.50 mm outer diameter and contains 5.67 square feet of filter surface area. The membrane is cleaned with chlorine (2–200 mg/L) at pH 11 using sodium hydroxide. The membrane has an average pore size of 0.2 μm and a Molecular Weight Cut-off of 100,000. The research study evaluated removal of turbidity (2, 5, and 10 ntu) and microbial surrogates (3 micron polystyrene latex (PSL) beads, MS-2 bacteriophage, and E. coli). Other parameters of interest included system flux, runtime, raw water characteristics, and operating cost. Results are summarized and presented on turbidity and microbial removal efficiency.