E. Radha Krishnan
Research Subjects
E. Radha Krishnan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Craig. L. Patterson
USEPA
14 shared publications - Rajib Sinha
Shaw Environmental and Infrastructure, Inc, 5050 Section Avenue, Cincinnati, OH 45212
12 shared publications - Nur Muhammad
Shaw Environmental and Infrastructure, Inc, 5050 Section Avenue, Cincinnati, OH 45212
8 shared publications - Roy C. Haught
U.S. Environmental Protection Agency, ORD/NRMRL/WSWRD, 26 W. Martin Luther King Drive, Cincinnati, OH 45268
6 shared publications - Srinivas Panguluri
Shaw Environmental & Infrastructure, Inc
5 shared publications - Robert M. Clark
Environmental Engineering & Public Health Consultant
4 shared publications
Latest Publications
- 10 January 2012
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 223 (5) , 2837-2847
Removal of Trichloroethylene by Activated Carbon in the Presence and Absence of TiO2 Nanoparticles
- 10 January 2012
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 223 (5) , 2837-2847
Removal of Trichloroethylene by Activated Carbon in the Presence and Absence of TiO2 Nanoparticles
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 1552-1561
Use of Biological and Non-Biological Surrogates for Evaluating Cryptosporidium Removal by Filtration
Water treatment plants are currently facing increasing challenges in monitoring Cryptosporidium in source and treated water because of complex analytical techniques and associated health risks. Surrogates may be easier to analyze than Cryptosporidium, but they must also be reliable and representative of results. Polystyrene Latex (PSL) beads of 2 – 3 μm size have been suggested by researchers as a potential non-biological surrogate for Cryptosporidium as it mimics the size and surface characteristics of the pathogen. Bacillus subtilis (B. subtilis) spores have also been suggested by researchers as a potential biological surrogate for Cryptosporidium because of their resistance to conventional disinfectants and abundance in surface water. Therefore, it is important to examine the surrogacy of PSL beads and B. subtilis spores based on filtration mechanisms. This paper summarizes the results of PSL beads, B. subtilis and Cryptosporidium challenge tests conducted on different package water treatment systems that include bag and cartridge units, membrane and granular media filtration units, and adsorptive systems with charged media. Analytical techniques and the accuracy of surrogate results are discussed and compared for various types of treatment units evaluated at EPA's Test and Evaluation Facility in Cincinnati, Ohio, and different field locations.
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 1552-1561
Use of Biological and Non-Biological Surrogates for Evaluating Cryptosporidium Removal by Filtration
Water treatment plants are currently facing increasing challenges in monitoring Cryptosporidium in source and treated water because of complex analytical techniques and associated health risks. Surrogates may be easier to analyze than Cryptosporidium, but they must also be reliable and representative of results. Polystyrene Latex (PSL) beads of 2 – 3 μm size have been suggested by researchers as a potential non-biological surrogate for Cryptosporidium as it mimics the size and surface characteristics of the pathogen. Bacillus subtilis (B. subtilis) spores have also been suggested by researchers as a potential biological surrogate for Cryptosporidium because of their resistance to conventional disinfectants and abundance in surface water. Therefore, it is important to examine the surrogacy of PSL beads and B. subtilis spores based on filtration mechanisms. This paper summarizes the results of PSL beads, B. subtilis and Cryptosporidium challenge tests conducted on different package water treatment systems that include bag and cartridge units, membrane and granular media filtration units, and adsorptive systems with charged media. Analytical techniques and the accuracy of surrogate results are discussed and compared for various types of treatment units evaluated at EPA's Test and Evaluation Facility in Cincinnati, Ohio, and different field locations.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 261-269
Bench-Scale Evaluation of Peracetic Acid and Twin Oxide as Disinfectants in Drinking Water
Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S. Environmental Protection Agency's (EPA's) Test and Evaluation (T&E) Facility in Cincinnati, Ohio on peracetic acid (PAA), an alternative disinfectant for drinking water which is purported to reduce DBP formation. PAA has been extensively studied as a disinfectant in wastewater and to a lesser extent in drinking water. The tests were carried out in a nanopure water matrix. The total organic carbon (TOC) level in the test water was increased to target levels of 0.5 to 1.5 mg/L by the addition of humic acid. E. Coli was added as the target microbial organism at initial concentrations of 106 Colony Forming Units (CFU)/100 ml. PAA doses were varied from target levels of 0.5 to 2.5 mg/L for contact times of 10 minutes. E. Coli log removal rates above 4.5 were achieved for disinfectant concentrations above 1 mg/L and were insensitive to TOC levels. DBP analyses did not detect any total trihalomethane production (TTHMs) arising from the disinfection process. No conclusions could be drawn concerning bacterial regrowth in the disinfected samples. Future work will compare disinfection efficiency and DBP production of PAA with Twin Oxide TM, a chlorine dioxide based powder disinfectant.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 261-269
Bench-Scale Evaluation of Peracetic Acid and Twin Oxide as Disinfectants in Drinking Water
Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S. Environmental Protection Agency's (EPA's) Test and Evaluation (T&E) Facility in Cincinnati, Ohio on peracetic acid (PAA), an alternative disinfectant for drinking water which is purported to reduce DBP formation. PAA has been extensively studied as a disinfectant in wastewater and to a lesser extent in drinking water. The tests were carried out in a nanopure water matrix. The total organic carbon (TOC) level in the test water was increased to target levels of 0.5 to 1.5 mg/L by the addition of humic acid. E. Coli was added as the target microbial organism at initial concentrations of 106 Colony Forming Units (CFU)/100 ml. PAA doses were varied from target levels of 0.5 to 2.5 mg/L for contact times of 10 minutes. E. Coli log removal rates above 4.5 were achieved for disinfectant concentrations above 1 mg/L and were insensitive to TOC levels. DBP analyses did not detect any total trihalomethane production (TTHMs) arising from the disinfection process. No conclusions could be drawn concerning bacterial regrowth in the disinfected samples. Future work will compare disinfection efficiency and DBP production of PAA with Twin Oxide TM, a chlorine dioxide based powder disinfectant.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 281-288
Evaluation of a Pour-Through Water Treatment Device for Use as Microbiological Purifier
The United States Environmental Protection Agency (EPA) Office of Research and Development has evaluated the performance of a Point-of-Use (POU) pour-through device designed for use in India, developing and emerging market (D&E) countries, and under emergency situations in the United States. In collaboration with the Unilever Research India, a series of microbial tests were conducted on a Unilever PureitTM microbiological purifier for household drinking water at the EPA's Test and Evaluation Facility in Cincinnati, Ohio. The PureitTM water treatment system is fed by gravity and combines the unit operations of physical filtration, chlorine disinfection, and carbon adsorption for treating drinking water. EPA evaluated the PureitTM device for removal of E. coli (as a surrogate for bacteria), and MS2 bacteriophage (as a surrogate for viruses). Results demonstrated that the PureitTM system achieved EPA requirements of a 6 log reduction of bacteria and a 4 log reduction of virus for a "Microbiological Purifier" throughout the design life of the device (∼ 2250 liters). The final polisher of the unit was capable of reducing the residual chlorine concentration to less than the EPA's 2 mg/L maximum limit for tap water.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 281-288
Evaluation of a Pour-Through Water Treatment Device for Use as Microbiological Purifier
The United States Environmental Protection Agency (EPA) Office of Research and Development has evaluated the performance of a Point-of-Use (POU) pour-through device designed for use in India, developing and emerging market (D&E) countries, and under emergency situations in the United States. In collaboration with the Unilever Research India, a series of microbial tests were conducted on a Unilever PureitTM microbiological purifier for household drinking water at the EPA's Test and Evaluation Facility in Cincinnati, Ohio. The PureitTM water treatment system is fed by gravity and combines the unit operations of physical filtration, chlorine disinfection, and carbon adsorption for treating drinking water. EPA evaluated the PureitTM device for removal of E. coli (as a surrogate for bacteria), and MS2 bacteriophage (as a surrogate for viruses). Results demonstrated that the PureitTM system achieved EPA requirements of a 6 log reduction of bacteria and a 4 log reduction of virus for a "Microbiological Purifier" throughout the design life of the device (∼ 2250 liters). The final polisher of the unit was capable of reducing the residual chlorine concentration to less than the EPA's 2 mg/L maximum limit for tap water.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 289-299
Evaluation of Long-Term Performance of Point of Use (POU) Systems for Drinking Water Treatment
The U.S. Environmental Protection Agency (EPA) initiated a research program in 2008 at the EPA Test and Evaluation (T&E) Facility in Cincinnati, Ohio to evaluate the performance of various Point-of-Use (POU) treatment devices for providing drinking water in homes and transient non-community water systems, either routinely or as an emergency measure during accidental or intentional contamination events. This paper describes the results of the performance of two POU devices based on reverse osmosis (RO) technology. The POU devices were continuously operated for about 22 months (670 days) to evaluate their long-term performance and challenged with microbiological contaminants at different time intervals to evaluate continued treatment effectiveness. The microbiological contaminant challenge contaminants included E. coli, MS2 bacteriophage, B. subtilis and polystyrene latex (PSL) beads (evaluated as a non-biological surrogate for Cryptosporidium). The results of tests conducted to date show complete removal of the selected microorganisms and surrogates by the POU systems both at startup and after 22 months of operation. The two RO-based POU systems satisfied the Long-Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirements for Cryptosporidium removal. The POU devices performed favorably when compared to the reduction requirement of the EPA Guide Standard Protocol for Microbiological Water Purifiers (U.S. EPA, 1987), which is 6 log for bacteria and 4 log for viruses.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 289-299
Evaluation of Long-Term Performance of Point of Use (POU) Systems for Drinking Water Treatment
The U.S. Environmental Protection Agency (EPA) initiated a research program in 2008 at the EPA Test and Evaluation (T&E) Facility in Cincinnati, Ohio to evaluate the performance of various Point-of-Use (POU) treatment devices for providing drinking water in homes and transient non-community water systems, either routinely or as an emergency measure during accidental or intentional contamination events. This paper describes the results of the performance of two POU devices based on reverse osmosis (RO) technology. The POU devices were continuously operated for about 22 months (670 days) to evaluate their long-term performance and challenged with microbiological contaminants at different time intervals to evaluate continued treatment effectiveness. The microbiological contaminant challenge contaminants included E. coli, MS2 bacteriophage, B. subtilis and polystyrene latex (PSL) beads (evaluated as a non-biological surrogate for Cryptosporidium). The results of tests conducted to date show complete removal of the selected microorganisms and surrogates by the POU systems both at startup and after 22 months of operation. The two RO-based POU systems satisfied the Long-Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirements for Cryptosporidium removal. The POU devices performed favorably when compared to the reduction requirement of the EPA Guide Standard Protocol for Microbiological Water Purifiers (U.S. EPA, 1987), which is 6 log for bacteria and 4 log for viruses.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 270-278
Laboratory and Field Evaluation of a Nanofilter Membrane to Remove Disinfection Byproduct Precursors and Microorganisms from Lake Water Sources Used for Drinking Water
Small community systems that use surface water as a source of drinking water are frequently faced with elevated levels of naturally-occurring organic matter (NOM) that are not removed by conventional filtration methods. These residual levels of NOM can then combine with chlorine used for disinfection and create disinfection byproducts (DBPs) that could potentially exceed the regulatory limit for various DBPs. Additional treatment for removal of these DBP compounds may be required for compliance with the requirements of the Safe Drinking Water Act (SDWA). The formation of DBPs can be prevented by removing NOM which act as DBP precursors. This paper presents the results of experiments conducted on two nanofilter membrane systems with a patented method for cleaning the membrane using a foam ball. The tests were conducted at the U.S. EPA Test & Evaluation (T&E) Facility (using dechlorinated potable water with the addition of humic acid to simulate NOM) and at a field site using lake water. The treatment system uses a tubular membrane with the ends connected to effectively form a single, long, membrane. A foam ball is periodically passed through the inside of the membrane by reversing the flow direction to scour the membrane surface and remove accumulated organic matter capable of fouling the membrane surface. This organic matter is then discharged by back-flushing the membrane. The effectiveness of the system in producing drinking water was gauged by measuring the turbidity, color, and organic content of the system inlet and outlet. Tests were also performed using the aerobic spore Bacillus subtilis (B. subtilis) as a surrogate for bacteria removal and MS2 bacteriophage as a surrogate for virus removal.
- 14 May 2010
- Published by American Society of Civil Engineers (ASCE)
- p. 270-278
Laboratory and Field Evaluation of a Nanofilter Membrane to Remove Disinfection Byproduct Precursors and Microorganisms from Lake Water Sources Used for Drinking Water
Small community systems that use surface water as a source of drinking water are frequently faced with elevated levels of naturally-occurring organic matter (NOM) that are not removed by conventional filtration methods. These residual levels of NOM can then combine with chlorine used for disinfection and create disinfection byproducts (DBPs) that could potentially exceed the regulatory limit for various DBPs. Additional treatment for removal of these DBP compounds may be required for compliance with the requirements of the Safe Drinking Water Act (SDWA). The formation of DBPs can be prevented by removing NOM which act as DBP precursors. This paper presents the results of experiments conducted on two nanofilter membrane systems with a patented method for cleaning the membrane using a foam ball. The tests were conducted at the U.S. EPA Test & Evaluation (T&E) Facility (using dechlorinated potable water with the addition of humic acid to simulate NOM) and at a field site using lake water. The treatment system uses a tubular membrane with the ends connected to effectively form a single, long, membrane. A foam ball is periodically passed through the inside of the membrane by reversing the flow direction to scour the membrane surface and remove accumulated organic matter capable of fouling the membrane surface. This organic matter is then discharged by back-flushing the membrane. The effectiveness of the system in producing drinking water was gauged by measuring the turbidity, color, and organic content of the system inlet and outlet. Tests were also performed using the aerobic spore Bacillus subtilis (B. subtilis) as a surrogate for bacteria removal and MS2 bacteriophage as a surrogate for virus removal.
- 9 November 2009
- Published by IWA Publishing in Journal of Water and Health
- Vol. 8 (2) , 212-223
Evaluating a composite cartridge for small system drinking water treatment
A pilot-scale evaluation was conducted at the U.S Environmental Protection Agency (EPA) Test & Evaluation (T&E) Facility in Cincinnati, Ohio, on a multi-layer, cartridge-based system that combines physical filtration with carbon adsorption and ultraviolet (UV) light disinfection to serve as a home-base water treatment security device against accidental or intentional contaminant events. The system was challenged with different levels of turbidity, a number of biological contaminants including Bacillus subtilis, Escherichia coli, MS2bacteriophage and Polystyrene Latex (PSL) beads as a surrogate for Cryptosporidium and a number of chemical contaminants including super-chlorination, methyl tertiary butyl ether (MTBE), water chlorination disinfection byproducts (DBPs) and diazinon. The results demonstrated that the performance of the system varies as a function of the specific contaminant or surrogate. The overall performance indicated the potential of the system to improve the quality and safety of household water and to serve as an additional treatment barrier in circumstances where there is little or no treatment or where the quality of treated water may have deteriorated during distribution. The results also demonstrated that B. subtilis spore can serve as a more conservative surrogate for Cryptosporidium than PSL beads.
- 9 November 2009
- Published by IWA Publishing in Journal of Water and Health
- Vol. 8 (2) , 212-223
Evaluating a composite cartridge for small system drinking water treatment
A pilot-scale evaluation was conducted at the U.S Environmental Protection Agency (EPA) Test & Evaluation (T&E) Facility in Cincinnati, Ohio, on a multi-layer, cartridge-based system that combines physical filtration with carbon adsorption and ultraviolet (UV) light disinfection to serve as a home-base water treatment security device against accidental or intentional contaminant events. The system was challenged with different levels of turbidity, a number of biological contaminants including Bacillus subtilis, Escherichia coli, MS2bacteriophage and Polystyrene Latex (PSL) beads as a surrogate for Cryptosporidium and a number of chemical contaminants including super-chlorination, methyl tertiary butyl ether (MTBE), water chlorination disinfection byproducts (DBPs) and diazinon. The results demonstrated that the performance of the system varies as a function of the specific contaminant or surrogate. The overall performance indicated the potential of the system to improve the quality and safety of household water and to serve as an additional treatment barrier in circumstances where there is little or no treatment or where the quality of treated water may have deteriorated during distribution. The results also demonstrated that B. subtilis spore can serve as a more conservative surrogate for Cryptosporidium than PSL beads.
- 12 May 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Development of a Community Water Security Filtration System Using Composite Cartridges
Under a Cooperative Research and Development Agreement (CRADA) established between the U.S. Environmental Protection Agency (EPA) and Harmsco, Inc., a prototype Community Water Security Filtration System for drinking water treatment using composite cartridges is being developed and tested at the EPA's Test & Evaluation (T&E) Facility in Cincinnati, Ohio. The filtration system incorporates a composite cartridge that combines physical pre-filtration with carbon adsorption and a cyst-rated final filter for removal of turbidity, specific chemical compounds, and some biological oocysts. The composite cartridge is then followed by ultraviolet (UV) light to provide short wave UV disinfection. The housing is constructed with a tangential inlet that induces a centrifugal motion to the water which aids filtratiom. The research has focused on optimizing the filtration media and housing configuration by testing the system using various biological surrogates and chemical compounds as contaminants. The current system configuration consists of a housing with two chambers; the upper chamber contains 8 (eight) composite cartridges for filtration, while the lower chamber contains six UV lamps for disinfection. Electrodes have been installed between the internal cartridge basket and the housing wall to provide an experimental electroseparation process to enhance particulate and pathogen removal and to determine if there is any pathogen cell disruption. Results of developmental tests conducted on single cartridges to optimize the composite cartridge media configuration show complete removal of Polystyrene Latex (PSL) beads (used as a non-biological surrogate for Cryptosporidium) which satisfies the Long Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirement of >3.0 log reduction of Cryptosporidium. Results of tests conducted on the 8-chamber full-scale unit show almost complete removal of MS2 bacteriophage as a surrogate for enteric virus satisfying the LT2ESWTR requirement of a 4-log reduction for viruses.
- 12 May 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Development of a Community Water Security Filtration System Using Composite Cartridges
Under a Cooperative Research and Development Agreement (CRADA) established between the U.S. Environmental Protection Agency (EPA) and Harmsco, Inc., a prototype Community Water Security Filtration System for drinking water treatment using composite cartridges is being developed and tested at the EPA's Test & Evaluation (T&E) Facility in Cincinnati, Ohio. The filtration system incorporates a composite cartridge that combines physical pre-filtration with carbon adsorption and a cyst-rated final filter for removal of turbidity, specific chemical compounds, and some biological oocysts. The composite cartridge is then followed by ultraviolet (UV) light to provide short wave UV disinfection. The housing is constructed with a tangential inlet that induces a centrifugal motion to the water which aids filtratiom. The research has focused on optimizing the filtration media and housing configuration by testing the system using various biological surrogates and chemical compounds as contaminants. The current system configuration consists of a housing with two chambers; the upper chamber contains 8 (eight) composite cartridges for filtration, while the lower chamber contains six UV lamps for disinfection. Electrodes have been installed between the internal cartridge basket and the housing wall to provide an experimental electroseparation process to enhance particulate and pathogen removal and to determine if there is any pathogen cell disruption. Results of developmental tests conducted on single cartridges to optimize the composite cartridge media configuration show complete removal of Polystyrene Latex (PSL) beads (used as a non-biological surrogate for Cryptosporidium) which satisfies the Long Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) requirement of >3.0 log reduction of Cryptosporidium. Results of tests conducted on the 8-chamber full-scale unit show almost complete removal of MS2 bacteriophage as a surrogate for enteric virus satisfying the LT2ESWTR requirement of a 4-log reduction for viruses.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-12
Controlling Disinfection Residual Losses in Drinking Water Distribution Systems: Results from Experimental Studies
It has become generally accepted that water quality can deteriorate in a distribution system through reactions in the bulk phase and/or at the pipe wall. These reactions may be physical, chemical and/or microbiological in nature. Perhaps one of the most serious aspects of water quality deterioration in a network is the loss of the disinfectant residual that can weaken the barrier against microbial contamination. Studies have suggested that one factor contributing to the loss of disinfectant residuals is the reaction between bulk phase disinfectants and pipe wall material. Free chlorine loss in corroded metal pipes, subject to changes in velocity, was assessed during an experiment conducted under controlled conditions in a specially constructed pipe loop located at the U.S Environmental Protection Agency's (EPA's) Test and Evaluation (T&E) Facility in Cincinnati, Ohio (USA). These studies demonstrated that in older unlined metal pipes, the loss of chlorine residual increases with flow. Additional experimental studies are currently being conducted by the USEPA. They are intended to study the effect of hydrodynamics on disinfectant residual wall demand as well as the effect of total organic carbon, initial disinfectant levels, and pipe materials on chlorine and chloramine decay and disinfection by-product (DBP) formation. These experiments are being conducted in parallel using both unlined metallic and new polyvinyl chloride (PVC) pipe. The first phase of these experiments (which will be reported here) has focused on the effect of flow rate and pipe materials on the loss of chlorine disinfectant residuals. Results from these studies indicate that there is significant disinfectant wall demand in unlined metallic pipe even under stagnant and laminar flow conditions and that increases in flow rate can increase this demand. Wall demand in the PVC pipe, however, was found to be virtually nonexistent. Studies were also conducted on the rate of trihalomethanes (THM) formation under stagnant, laminar, transitional and turbulent conditions. Planned experiments include studies on chloramines and further attempts to isolate the effects of materials on disinfectant reaction kinetics. It is believed that results from these studies can be used to develop strategies to help maintain adequate disinfectant levels in distribution system networks.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-12
Controlling Disinfection Residual Losses in Drinking Water Distribution Systems: Results from Experimental Studies
It has become generally accepted that water quality can deteriorate in a distribution system through reactions in the bulk phase and/or at the pipe wall. These reactions may be physical, chemical and/or microbiological in nature. Perhaps one of the most serious aspects of water quality deterioration in a network is the loss of the disinfectant residual that can weaken the barrier against microbial contamination. Studies have suggested that one factor contributing to the loss of disinfectant residuals is the reaction between bulk phase disinfectants and pipe wall material. Free chlorine loss in corroded metal pipes, subject to changes in velocity, was assessed during an experiment conducted under controlled conditions in a specially constructed pipe loop located at the U.S Environmental Protection Agency's (EPA's) Test and Evaluation (T&E) Facility in Cincinnati, Ohio (USA). These studies demonstrated that in older unlined metal pipes, the loss of chlorine residual increases with flow. Additional experimental studies are currently being conducted by the USEPA. They are intended to study the effect of hydrodynamics on disinfectant residual wall demand as well as the effect of total organic carbon, initial disinfectant levels, and pipe materials on chlorine and chloramine decay and disinfection by-product (DBP) formation. These experiments are being conducted in parallel using both unlined metallic and new polyvinyl chloride (PVC) pipe. The first phase of these experiments (which will be reported here) has focused on the effect of flow rate and pipe materials on the loss of chlorine disinfectant residuals. Results from these studies indicate that there is significant disinfectant wall demand in unlined metallic pipe even under stagnant and laminar flow conditions and that increases in flow rate can increase this demand. Wall demand in the PVC pipe, however, was found to be virtually nonexistent. Studies were also conducted on the rate of trihalomethanes (THM) formation under stagnant, laminar, transitional and turbulent conditions. Planned experiments include studies on chloramines and further attempts to isolate the effects of materials on disinfectant reaction kinetics. It is believed that results from these studies can be used to develop strategies to help maintain adequate disinfectant levels in distribution system networks.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-13
Condition Assessment Modeling for Drinking Water Distribution Systems: An Example of Shared Frailty Analysis
It has been estimated that replacement of drinking water infrastructure will need to increase from the current estimated replacement rate of 0.3 percent per year to 2.0 percent per year by 2040 in order to meet the needs of US drinking water utilities. This is approximately four times the current replacement rate. In addition to maintenance, structural and regulatory issues, there is concern over the ability of US drinking water distribution systems to maintain water quality to the consumer. Consequently, drinking water utilities are increasingly interested in the potential for the application of techniques such as Condition Assessment (CA) methodology for managing drinking water infrastructure. The USEPA has therefore initiated a project (carried out by the Eastern Research Group) with the goal of developing new CA techniques that can assist utilities in dealing with some of these issues. Several tools have been developed (which will be discussed) including a modeling approach that can be applied to a drinking water utilities break and leak database and that will help managers understand the factors affecting the "survival" of drinking water pipe sections. The model is based on the application of the Cox Proportional Hazard Model (CPHM) modified by a frailty function. Shared frailty represents unobserved external factors, known to be important, which vary randomly and which are more consistent among sections in the same pipe run than among sections in different pipe runs. Examples of factors which may be represented in this way are soil corrosivity, variations in external mechanical loading, pressure transients, vibration, nearby construction, etc. The CPHM has been applied to a pipe break data base collected by the Laramie Water Utility (located in Laramie, Wyoming (USA)). Preliminary results, for example, indicate that, on the average, metallic pipe has fewer beaks than Poly Vinyl Chloride (PVC) pipe but is more subject to undefined random factors. That is, metallic pipe has more "random frailty" then PVC pipe. This has implications for infrastructure management policies such as the application of advanced monitoring techniques and replacement strategies. In addition to the CPHM for individual pipe sections a general pipe break model has been developed.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-13
Condition Assessment Modeling for Drinking Water Distribution Systems: An Example of Shared Frailty Analysis
It has been estimated that replacement of drinking water infrastructure will need to increase from the current estimated replacement rate of 0.3 percent per year to 2.0 percent per year by 2040 in order to meet the needs of US drinking water utilities. This is approximately four times the current replacement rate. In addition to maintenance, structural and regulatory issues, there is concern over the ability of US drinking water distribution systems to maintain water quality to the consumer. Consequently, drinking water utilities are increasingly interested in the potential for the application of techniques such as Condition Assessment (CA) methodology for managing drinking water infrastructure. The USEPA has therefore initiated a project (carried out by the Eastern Research Group) with the goal of developing new CA techniques that can assist utilities in dealing with some of these issues. Several tools have been developed (which will be discussed) including a modeling approach that can be applied to a drinking water utilities break and leak database and that will help managers understand the factors affecting the "survival" of drinking water pipe sections. The model is based on the application of the Cox Proportional Hazard Model (CPHM) modified by a frailty function. Shared frailty represents unobserved external factors, known to be important, which vary randomly and which are more consistent among sections in the same pipe run than among sections in different pipe runs. Examples of factors which may be represented in this way are soil corrosivity, variations in external mechanical loading, pressure transients, vibration, nearby construction, etc. The CPHM has been applied to a pipe break data base collected by the Laramie Water Utility (located in Laramie, Wyoming (USA)). Preliminary results, for example, indicate that, on the average, metallic pipe has fewer beaks than Poly Vinyl Chloride (PVC) pipe but is more subject to undefined random factors. That is, metallic pipe has more "random frailty" then PVC pipe. This has implications for infrastructure management policies such as the application of advanced monitoring techniques and replacement strategies. In addition to the CPHM for individual pipe sections a general pipe break model has been developed.