Tuami Lasri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tuami Lasri has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Kamel Haddadi
Institute of Electronics, Microelectronics and Nanotechnology, Villeneuve d’Ascq, France
6 shared publications- David Glay
Institute of Electronics, Microelectronics and Nanotechnology, Villeneuve d’Ascq, France
3 shared publications - Gilles Dambrine
Institute of Electronics, Microelectronics and Nanotechnology, University Lille 1, Avenue Poincaré CS 60069 - 59652 Villeneuve d'Ascq Cedex - France
3 shared publications Sijia Gu
University Lille 1
3 shared publicationsAhmed Mamouni
Institut d'Electronique et de Microelectronique du Nord (France)
2 shared publications- Jaouad Marzouk2 shared publications
Latest Publications
- Open Access
- 8 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 12 (2) , 160-166
Flexible UWB organic antenna for wearable technologies application
New generations of printed flexible antennas are playing an important role in wireless communication systems. The ultra wide band and wearable possibilities are critical aspects of these kinds of antennas. In this study, the proposed antenna is an elliptical monopole fed by a coplanar waveguide; it uses a kapton substrate and it is optimised to work from 1 to 8 GHz. In the case of copper, a conductive nanocomposite material based on a polymer (polyaniline: PANI) and charged by multiwalled carbon nanotubes (MWCNTs) is exploited. The flexibility of both the kapton substrate and the nanocomposite (PANI/MWCNTs) provides the ability to crumple the antenna paving the way to potential applications for body‐worn wireless communications systems. In this study, the performance of the antenna is investigated in terms of return loss, radiation patterns and gain for both crumpled and uncrumpled antennas. The results confirm that performance remains at a good level when the antenna is crumpled.
- 8 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 12 (2) , 160-166
Open AccessFlexible UWB organic antenna for wearable technologies application
New generations of printed flexible antennas are playing an important role in wireless communication systems. The ultra wide band and wearable possibilities are critical aspects of these kinds of antennas. In this study, the proposed antenna is an elliptical monopole fed by a coplanar waveguide; it uses a kapton substrate and it is optimised to work from 1 to 8 GHz. In the case of copper, a conductive nanocomposite material based on a polymer (polyaniline: PANI) and charged by multiwalled carbon nanotubes (MWCNTs) is exploited. The flexibility of both the kapton substrate and the nanocomposite (PANI/MWCNTs) provides the ability to crumple the antenna paving the way to potential applications for body‐worn wireless communications systems. In this study, the performance of the antenna is investigated in terms of return loss, radiation patterns and gain for both crumpled and uncrumpled antennas. The results confirm that performance remains at a good level when the antenna is crumpled.
- 6 December 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (1) , 014014
Dielectric properties characterization of saline solutions by near-field microwave microscopy
Saline solutions are of a great interest when characterizations of biological fluids are targeted. In this work a near-field microwave microscope is proposed for the characterization of liquids. An interferometric technique is suggested to enhance measurement sensitivity and accuracy. The validation of the setup and the measurement technique is conducted through the characterization of a large range of saline concentrations (0 – 160 mg ml −1 ). Based on the measured resonance frequency shift and quality factor, the complex permittivity is successfully extracted as exhibited by the good agreement found when comparing the results to data obtained from Cole–Cole model. We demonstrate that the near field microwave microscope (NFMM) brings a great advantage by offering the possibility to select a resonance frequency and a quality factor for a given concentration level. This method provides a very effective way to largely enhance the measurement sensitivity in high loss materials.
- 6 December 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (1) , 014014
Dielectric properties characterization of saline solutions by near-field microwave microscopy
Saline solutions are of a great interest when characterizations of biological fluids are targeted. In this work a near-field microwave microscope is proposed for the characterization of liquids. An interferometric technique is suggested to enhance measurement sensitivity and accuracy. The validation of the setup and the measurement technique is conducted through the characterization of a large range of saline concentrations (0 – 160 mg ml −1 ). Based on the measured resonance frequency shift and quality factor, the complex permittivity is successfully extracted as exhibited by the good agreement found when comparing the results to data obtained from Cole–Cole model. We demonstrate that the near field microwave microscope (NFMM) brings a great advantage by offering the possibility to select a resonance frequency and a quality factor for a given concentration level. This method provides a very effective way to largely enhance the measurement sensitivity in high loss materials.
- 13 June 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (24) , 242903
Broadband dielectric characterization of aqueous saline solutions by an interferometer-based microwave microscope
The complex dielectric permittivity of aqueous saline solutions has been determined in the frequency range [2–18 GHz] with a home-made near-field microwave microscope. The instrument is built on a vector network analyzer, a matching network, and an evanescent microwave probe. The interferometer-based matching network enables highly reproducible, sensitive, and accurate measurements on the entire frequency band of operation. NaCl solutions concentrations ranging from 0 to 160 mg/ml are investigated at 25 °C. A maximum measurement sensitivity for NaCl concentrations is found to be equal to 2.3 dB/(mg/ml) and 7.7°/(mg/ml) for magnitude and phase-shift, respectively. To translate the measurement data (S parameters) to the corresponding complex permittivities, an inversion procedure based on a simple calibration model is applied. The resulting complex permittivities are found to be in a very good agreement with those calculated by Cole-Cole model.
- 13 June 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (24) , 242903
Broadband dielectric characterization of aqueous saline solutions by an interferometer-based microwave microscope
The complex dielectric permittivity of aqueous saline solutions has been determined in the frequency range [2–18 GHz] with a home-made near-field microwave microscope. The instrument is built on a vector network analyzer, a matching network, and an evanescent microwave probe. The interferometer-based matching network enables highly reproducible, sensitive, and accurate measurements on the entire frequency band of operation. NaCl solutions concentrations ranging from 0 to 160 mg/ml are investigated at 25 °C. A maximum measurement sensitivity for NaCl concentrations is found to be equal to 2.3 dB/(mg/ml) and 7.7°/(mg/ml) for magnitude and phase-shift, respectively. To translate the measurement data (S parameters) to the corresponding complex permittivities, an inversion procedure based on a simple calibration model is applied. The resulting complex permittivities are found to be in a very good agreement with those calculated by Cole-Cole model.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (9) , 4729-4730
Multiport Reflectometer Based on Subtractive Mixing
A compact multiport reflectometer using a new subtractive mixing scheme for the determination of reflection coefficients in the frequency range of 1-10 GHz is proposed. Compared with classical multiport reflectometers, the architecture proposed reduces the design complexity. Comparison between experimental results obtained from the proposed reflectometer and those given by a conventional network analyzer is given.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (9) , 4729-4730
Multiport Reflectometer Based on Subtractive Mixing
A compact multiport reflectometer using a new subtractive mixing scheme for the determination of reflection coefficients in the frequency range of 1-10 GHz is proposed. Compared with classical multiport reflectometers, the architecture proposed reduces the design complexity. Comparison between experimental results obtained from the proposed reflectometer and those given by a conventional network analyzer is given.
- 19 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 25 (7) , 436-438
V-Band Via-Less GCPW-to-Microstrip Transition Designed on PET Flexible Substrate Using Inkjet Printing Technology
In this letter, a grounded coplanar waveguide-to-microstrip (GCPW-to-MS) transition without via holes is presented. The transition is designed on a PET® substrate and fabricated using inkjet printing technology. To our knowledge, fabrication of transitions using inkjet printing technology has not been reported in the literature. The simulations have been performed using HFSS® software and the measurements have been carried out using a Vector Network Analyzer on a broad frequency band from 40 to 85 GHz. The effect of varying several geometrical parameters of the GCPW-to-MS on the electromagnetic response is also presented. The results obtained demonstrate good characteristics of the insertion loss better than 1.5 dB, and return loss larger than 10 dB in the V-band (50-75 GHz). Such transitions are suitable for characterization of microwave components built on different flexible substrates.
- 19 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 25 (7) , 436-438
V-Band Via-Less GCPW-to-Microstrip Transition Designed on PET Flexible Substrate Using Inkjet Printing Technology
In this letter, a grounded coplanar waveguide-to-microstrip (GCPW-to-MS) transition without via holes is presented. The transition is designed on a PET® substrate and fabricated using inkjet printing technology. To our knowledge, fabrication of transitions using inkjet printing technology has not been reported in the literature. The simulations have been performed using HFSS® software and the measurements have been carried out using a Vector Network Analyzer on a broad frequency band from 40 to 85 GHz. The effect of varying several geometrical parameters of the GCPW-to-MS on the electromagnetic response is also presented. The results obtained demonstrate good characteristics of the insertion loss better than 1.5 dB, and return loss larger than 10 dB in the V-band (50-75 GHz). Such transitions are suitable for characterization of microwave components built on different flexible substrates.
- 14 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (7) , 2226-2227
Interferometer-Based Microwave Microscopy Operating in Transmission Mode
A microwave near-field sensing technique with sub-wavelength resolution is proposed for nondestructive local characterization of materials. The method is based on the measurement of a transmission coefficient by means of an association of a vector network analyzer, a hybrid coupler, an evanescent microwave coaxial probe, and an impedance tuner built up with a high precision programmable delay line and a variable motor-driven attenuator. Simplicity of operation and tuning possibility of the measurement sensitivity in the presence of the material under investigation are competitive advantages of the method. The depth and lateral resolutions of the microscope are experimentally verified.
- 14 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (7) , 2226-2227
Interferometer-Based Microwave Microscopy Operating in Transmission Mode
A microwave near-field sensing technique with sub-wavelength resolution is proposed for nondestructive local characterization of materials. The method is based on the measurement of a transmission coefficient by means of an association of a vector network analyzer, a hybrid coupler, an evanescent microwave coaxial probe, and an impedance tuner built up with a high precision programmable delay line and a variable motor-driven attenuator. Simplicity of operation and tuning possibility of the measurement sensitivity in the presence of the material under investigation are competitive advantages of the method. The depth and lateral resolutions of the microscope are experimentally verified.
- 20 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 15 (1) , 30-39
Measurement Techniques for RF Nanoelectronic Devices: New Equipment to Overcome the Problems of Impedance and Scale Mismatch
The emergence of new materials (nanowires, nanotubes, graphene tapes, and thin films) and devices with nanoscale dimensions give rise to the necessity for developing dedicated techniques that will allow their electrical characterization at high-frequency range. In this article, two possible views have been highlighted to tackle the issue of the measurement of high-impedance nanoscale devices. The first solution is based on the integration of a high-impedance reflectometer and a nanoscale device on the same chip. The microwave impedance of a single CNT has been successfully measured up to 6 GHz using this technique. The second solution consists of inserting an adjustable microwave interferometer between a traditional VNA and the high-impedance device. The interferometer allows adjustment of the impedance to be measured to the highest measurement sensitivity of the measurement system. In particular, capacitances down to 0.35 fF have been measured with an error estimated to be less than 10% using the interferometric technique combined with a scanning microwave microscope. These proofs of concept on one-port nanodevices open the route towards the case of two-port active devices with high impedance. Advances in the manufacturing of next-generation nanodevices will depend on our ability to measure electrical properties and performance characteristics accurately and reproducibly at the nanoscale regime over a broad frequency range.
- 20 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 15 (1) , 30-39
Measurement Techniques for RF Nanoelectronic Devices: New Equipment to Overcome the Problems of Impedance and Scale Mismatch
The emergence of new materials (nanowires, nanotubes, graphene tapes, and thin films) and devices with nanoscale dimensions give rise to the necessity for developing dedicated techniques that will allow their electrical characterization at high-frequency range. In this article, two possible views have been highlighted to tackle the issue of the measurement of high-impedance nanoscale devices. The first solution is based on the integration of a high-impedance reflectometer and a nanoscale device on the same chip. The microwave impedance of a single CNT has been successfully measured up to 6 GHz using this technique. The second solution consists of inserting an adjustable microwave interferometer between a traditional VNA and the high-impedance device. The interferometer allows adjustment of the impedance to be measured to the highest measurement sensitivity of the measurement system. In particular, capacitances down to 0.35 fF have been measured with an error estimated to be less than 10% using the interferometric technique combined with a scanning microwave microscope. These proofs of concept on one-port nanodevices open the route towards the case of two-port active devices with high impedance. Advances in the manufacturing of next-generation nanodevices will depend on our ability to measure electrical properties and performance characteristics accurately and reproducibly at the nanoscale regime over a broad frequency range.
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 388-391
Interferometric Near-field Microwave Microscopy Platform for Electromagnetic Micro-analysis
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 388-391
Open AccessInterferometric Near-field Microwave Microscopy Platform for Electromagnetic Micro-analysis
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 692-695
Miniaturized Microcantilever-based RF Microwave Probes Using MEMS Technologies
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 692-695
Open AccessMiniaturized Microcantilever-based RF Microwave Probes Using MEMS Technologies
- 1 January 2012
- Published by The Electromagnetics Academy in Progress in Electromagnetics Research C
- Vol. 30, 105-118
ONE DECADE MICROWAVE FORWARD NETWORK ANALYZER BASED ON THE MULTI-PORT TECHNIQUE
- 1 January 2012
- Published by The Electromagnetics Academy in Progress in Electromagnetics Research C
- Vol. 30, 105-118
ONE DECADE MICROWAVE FORWARD NETWORK ANALYZER BASED ON THE MULTI-PORT TECHNIQUE