David Glay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Glay has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Tuami Lasri
Institut d'Electronique, de Microélectronique et de Nanotechnologie (IEMN) France
3 shared publications Abdelhatif El Fellahi
Institute of Electronics, Microelectronics and Nanotechnology, Villeneuve d’Ascq, France
2 shared publicationsAhmed Mamouni
Institut d'Electronique et de Microelectronique du Nord (France)
2 shared publicationsTuami Lasri
Institut d'Electronique de Microélectronique et de Nanotechnologie UMR CNRS 8520, University of Lille1, Avenue Poincaré—CS 60069 59652 Villeneuve d'Ascq Cedex France
2 shared publicationsYves Leroy
Institut d'Electronique et de Microelectronique du Nord (France)
2 shared publicationsAdelhatif El Fellahi
IEMN – University of Lille 1, Av. Poincaré – CS 60069, 59652 Villeneuve d'Ascq, France. Phone: +33 (0)320197941
1 shared publication
Latest Publications
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (9) , 4729-4730
Multiport Reflectometer Based on Subtractive Mixing
A compact multiport reflectometer using a new subtractive mixing scheme for the determination of reflection coefficients in the frequency range of 1-10 GHz is proposed. Compared with classical multiport reflectometers, the architecture proposed reduces the design complexity. Comparison between experimental results obtained from the proposed reflectometer and those given by a conventional network analyzer is given.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (9) , 4729-4730
Multiport Reflectometer Based on Subtractive Mixing
A compact multiport reflectometer using a new subtractive mixing scheme for the determination of reflection coefficients in the frequency range of 1-10 GHz is proposed. Compared with classical multiport reflectometers, the architecture proposed reduces the design complexity. Comparison between experimental results obtained from the proposed reflectometer and those given by a conventional network analyzer is given.
- 25 November 2013
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 56 (1) , 64-69
High reference impedance reflectometer for nonresonant matching of near‐field microwave microscope tip probe
In this letter, we present a nonresonant high impedance reflectometer integrating a tip probe dedicated to near‐field microwave microscopy. A 1‐kohms reflectometer is fabricated by using lumped elements to validate the approach proposed to solve the problem of impedance mismatch between the probe and the measurement system. © 2014 Wiley Periodicals, Inc. Microwave Opt Technol Lett 56:64–69, 2014
- 25 November 2013
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 56 (1) , 64-69
High reference impedance reflectometer for nonresonant matching of near‐field microwave microscope tip probe
In this letter, we present a nonresonant high impedance reflectometer integrating a tip probe dedicated to near‐field microwave microscopy. A 1‐kohms reflectometer is fabricated by using lumped elements to validate the approach proposed to solve the problem of impedance mismatch between the probe and the measurement system. © 2014 Wiley Periodicals, Inc. Microwave Opt Technol Lett 56:64–69, 2014
- 3 June 2013
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 5 (3) , 301-308
A proof of concept of a non-resonant near-field microwave microscope based on a high impedance reflectometer
In this paper, we present a non-resonant high impedance reflectometer with a reference impedance close to one of the tip probe of a near-field microwave microscope. We show that for an apex of the tip probe of 100 µm there is an optimum reference impedance close to 1 kΩ. To validate this approach a microwave circuit that makes use of lumped elements has been fabricated. A proof of concept is also explored for capacitance measurements between the tip probe and a metal plate.
- 3 June 2013
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 5 (3) , 301-308
A proof of concept of a non-resonant near-field microwave microscope based on a high impedance reflectometer
In this paper, we present a non-resonant high impedance reflectometer with a reference impedance close to one of the tip probe of a near-field microwave microscope. We show that for an apex of the tip probe of 100 µm there is an optimum reference impedance close to 1 kΩ. To validate this approach a microwave circuit that makes use of lumped elements has been fabricated. A proof of concept is also explored for capacitance measurements between the tip probe and a metal plate.
- 27 November 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4491, 270-280
Noncontact microwave material characterization
In this paper, a nondestructive method for the non-contact characterization of non-planar dielectric objects is presented. Traditionally, this kind of measurements is achieved by using spot-focused antennas associated to a vector automatic network analyzer. In this study, we propose a free space measurement system, fitted out with a classical horn antenna, which demonstrates its usefulness in many practical cases. The permittivity is computed from the reflection coefficient of metal-backed samples of different shapes at 2.45 GHz.
- 27 November 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4491, 270-280
Noncontact microwave material characterization
In this paper, a nondestructive method for the non-contact characterization of non-planar dielectric objects is presented. Traditionally, this kind of measurements is achieved by using spot-focused antennas associated to a vector automatic network analyzer. In this study, we propose a free space measurement system, fitted out with a classical horn antenna, which demonstrates its usefulness in many practical cases. The permittivity is computed from the reflection coefficient of metal-backed samples of different shapes at 2.45 GHz.
- 15 October 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3752, 29-39
Microwave sensors for nondestructive testing of materials
Much of today's applications in nondestructive testing by microwaves use an automatic network analyzer. As a result, there is a need for systems to reduce the cost of this kind of techniques. Fortunately, now we can benefit from the cost reduction of the microwave components, induced by the considerable development of the communication market, around 2 and 10 GHz. So, it seems reasonable to think that microwaves will take advantage of this new situation to assert themselves in this application field. In this context we conceive and develop original equipment competitive in term of price and reliability.
- 15 October 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3752, 29-39
Microwave sensors for nondestructive testing of materials
Much of today's applications in nondestructive testing by microwaves use an automatic network analyzer. As a result, there is a need for systems to reduce the cost of this kind of techniques. Fortunately, now we can benefit from the cost reduction of the microwave components, induced by the considerable development of the communication market, around 2 and 10 GHz. So, it seems reasonable to think that microwaves will take advantage of this new situation to assert themselves in this application field. In this context we conceive and develop original equipment competitive in term of price and reliability.