A. Wieser
Research Subjects
A. Wieser has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Paola Fattibene
Istituto Superiore di Sanita, Viale Regina Elena 299, 00161 Rome, Italy
6 shared publications - Nabil El-Faramawy
Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
4 shared publications S. Onori
4 shared publicationsA. Romanyukha
3 shared publications- Denis Vsevolodovich Ivanov
Russian Academy of Sciences
3 shared publications - Vadim Chumak
National Research Centre for Radiation Medicine, Kyiv, UKRAINE
3 shared publications
Latest Publications
- Open Access
- 7 March 2014
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 53 (2) , 321-333
Electron paramagnetic resonance measurements of absorbed dose in teeth from citizens of Ozyorsk
In 1945, within the frame of the Uranium Project for the production of nuclear weapons, the Mayak nuclear facilities were constructed at the Lake Irtyash in the Southern Urals, Russia. The nuclear workers of the Mayak Production Association (MPA), who lived in the city of Ozyorsk, are the focus of epidemiological studies for the assessment of health risks due to protracted exposure to ionising radiation. Electron paramagnetic resonance measurements of absorbed dose in tooth enamel have already been used in the past, in an effort to validate occupational external doses that were evaluated in the Mayak Worker Dosimetry System. In the present study, 229 teeth of Ozyorsk citizens not employed at MPA were investigated for the assessment of external background exposure in Ozyorsk. The annually absorbed dose in tooth enamel from natural background radiation was estimated to be (0.7 ± 0.3) mGy. For citizens living in Ozyorsk during the time of routine noble gas releases of the MPA, which peaked in 1953, the average excess absorbed dose in enamel above natural background was (36 ± 29) mGy, which is consistent with the gamma dose obtained by model calculations. In addition, there were indications of possible accidental gaseous MPA releases that affected the population of Ozyorsk, during the early and late MPA operation periods, before 1951 and after 1960.
- 7 March 2014
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 53 (2) , 321-333
Open AccessElectron paramagnetic resonance measurements of absorbed dose in teeth from citizens of Ozyorsk
In 1945, within the frame of the Uranium Project for the production of nuclear weapons, the Mayak nuclear facilities were constructed at the Lake Irtyash in the Southern Urals, Russia. The nuclear workers of the Mayak Production Association (MPA), who lived in the city of Ozyorsk, are the focus of epidemiological studies for the assessment of health risks due to protracted exposure to ionising radiation. Electron paramagnetic resonance measurements of absorbed dose in tooth enamel have already been used in the past, in an effort to validate occupational external doses that were evaluated in the Mayak Worker Dosimetry System. In the present study, 229 teeth of Ozyorsk citizens not employed at MPA were investigated for the assessment of external background exposure in Ozyorsk. The annually absorbed dose in tooth enamel from natural background radiation was estimated to be (0.7 ± 0.3) mGy. For citizens living in Ozyorsk during the time of routine noble gas releases of the MPA, which peaked in 1953, the average excess absorbed dose in enamel above natural background was (36 ± 29) mGy, which is consistent with the gamma dose obtained by model calculations. In addition, there were indications of possible accidental gaseous MPA releases that affected the population of Ozyorsk, during the early and late MPA operation periods, before 1951 and after 1960.
- 15 May 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 120 (1-4) , 176-183
The Third International Intercomparison on EPR Tooth Dosimetry: part 2, final analysis
The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.
- 15 May 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 120 (1-4) , 176-183
The Third International Intercomparison on EPR Tooth Dosimetry: part 2, final analysis
The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.
- 3 February 2006
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 44 (4) , 279-288
Comparison of EPR occupational lifetime external dose assessments for Mayak nuclear workers and film badge dose data
The Mayak worker cohort is one of the major sources of information on health risks due to protracted exposures to plutonium and external ionizing radiation. Electron paramagnetic resonance (EPR) measurements in tooth enamel in combination with personal dose monitoring can help to improve external dose assessment for this cohort. Here, the occupational lifetime external exposure was evaluated individually for 44 nuclear workers of three plants of the Mayak Production Association by EPR measurements of absorbed doses in collected tooth enamel samples. Analysis included consideration of individual background doses in enamel and dose conversion coefficients specific for photon spectra at selected work areas. As a control, background doses were assessed for various age groups by EPR measurements on teeth from non-occupationally exposed Ozyorsk residents. Differences in occupational lifetime doses estimated from the film badges and from enamel for the Mayak workers were found to depend on the type of film badge and the selected plant. For those who worked at the radiochemical processing plant and who were monitored with IFK film badges, the dose was on average 570 mGy larger than estimated from the EPR measurements. However, the average difference was found to be only −4 and 6 mGy for those who were monitored with IFKU film badges and worked at the reactor and the isotope production plant respectively. The discrepancies observed in the dose estimates are attributed to a bias in film badge evaluation.
- 3 February 2006
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 44 (4) , 279-288
Comparison of EPR occupational lifetime external dose assessments for Mayak nuclear workers and film badge dose data
The Mayak worker cohort is one of the major sources of information on health risks due to protracted exposures to plutonium and external ionizing radiation. Electron paramagnetic resonance (EPR) measurements in tooth enamel in combination with personal dose monitoring can help to improve external dose assessment for this cohort. Here, the occupational lifetime external exposure was evaluated individually for 44 nuclear workers of three plants of the Mayak Production Association by EPR measurements of absorbed doses in collected tooth enamel samples. Analysis included consideration of individual background doses in enamel and dose conversion coefficients specific for photon spectra at selected work areas. As a control, background doses were assessed for various age groups by EPR measurements on teeth from non-occupationally exposed Ozyorsk residents. Differences in occupational lifetime doses estimated from the film badges and from enamel for the Mayak workers were found to depend on the type of film badge and the selected plant. For those who worked at the radiochemical processing plant and who were monitored with IFK film badges, the dose was on average 570 mGy larger than estimated from the EPR measurements. However, the average difference was found to be only −4 and 6 mGy for those who were monitored with IFKU film badges and worked at the reactor and the isotope production plant respectively. The discrepancies observed in the dose estimates are attributed to a bias in film badge evaluation.
- 1 February 2005
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 62 (2) , 163-171
The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis
- 1 February 2005
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 62 (2) , 163-171
The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 545-548
Dose Reconstruction with Electron Paramagnetic Resonance Spectroscopy of Deciduous Teeth
In the present study the feasibility of using whole, naturally loose deciduous incisors for dose reconstruction with electron paramagnetic resonance (EPR) spectroscopy was investigated. The properties of EPR signals were analysed before and after laboratory irradiation. The parameters of the native EPR signal of deciduous incisors was found to be different from those from enamel of permanent molars. The native EPR signal of deciduous incisors with peak-to-peak line width of 0.65 mT was located at g = 2.0050. The evaluated parameters of the dosimetric EPR signal (CO2-) of deciduous incisors were in agreement with those for enamel of permanent molars. A detection threshold for absorbed dose of about 100 mGy was estimated.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 545-548
Dose Reconstruction with Electron Paramagnetic Resonance Spectroscopy of Deciduous Teeth
In the present study the feasibility of using whole, naturally loose deciduous incisors for dose reconstruction with electron paramagnetic resonance (EPR) spectroscopy was investigated. The properties of EPR signals were analysed before and after laboratory irradiation. The parameters of the native EPR signal of deciduous incisors was found to be different from those from enamel of permanent molars. The native EPR signal of deciduous incisors with peak-to-peak line width of 0.65 mT was located at g = 2.0050. The evaluated parameters of the dosimetric EPR signal (CO2-) of deciduous incisors were in agreement with those for enamel of permanent molars. A detection threshold for absorbed dose of about 100 mGy was estimated.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 549-552
Monte Carlo Calculation and Experimental Verification of the Photon Energy Response of Tooth Enamel in a Head-sized Plexiglas Phantom
The use of electron paramagnetic resonance (EPR) tooth dosimetry for calculation of organ doses requires conversion of the measured absorbed dose in enamel. Before deriving conversion factors from simulation calculations with a realistic anthropomorphic human phantom, in the current study a simplified phantom was chosen to compare EPR measurement and Monte Carlo calculation. The dose response of tooth enamel of molars at various positions inside a cylindrical Plexiglas phantom of head-size was calculated by Monte Carlo modelling in parallel photon beams of X rays of 63 keV equivalent energy and 60Co gamma rays (1.25 Mev). For X ray exposure, preliminary results of EPR dosimetry with tooth enamel samples prepared from molars irradiated in the phantom were in agreement with calculation. The mean value of the ratio of the measured to the calculated dose was 0.93 ± 0.08.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 549-552
Monte Carlo Calculation and Experimental Verification of the Photon Energy Response of Tooth Enamel in a Head-sized Plexiglas Phantom
The use of electron paramagnetic resonance (EPR) tooth dosimetry for calculation of organ doses requires conversion of the measured absorbed dose in enamel. Before deriving conversion factors from simulation calculations with a realistic anthropomorphic human phantom, in the current study a simplified phantom was chosen to compare EPR measurement and Monte Carlo calculation. The dose response of tooth enamel of molars at various positions inside a cylindrical Plexiglas phantom of head-size was calculated by Monte Carlo modelling in parallel photon beams of X rays of 63 keV equivalent energy and 60Co gamma rays (1.25 Mev). For X ray exposure, preliminary results of EPR dosimetry with tooth enamel samples prepared from molars irradiated in the phantom were in agreement with calculation. The mean value of the ratio of the measured to the calculated dose was 0.93 ± 0.08.
- 1 May 2001
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 54 (5) , 793-799
Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry
- 1 May 2001
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 54 (5) , 793-799
Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry
- 1 May 2000
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 52 (5) , 1059-1064
Comparison of sample preparation and signal evaluation methods for EPR analysis of tooth enamel
- 1 May 2000
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 52 (5) , 1059-1064
Comparison of sample preparation and signal evaluation methods for EPR analysis of tooth enamel