    Super-Cluster collimation for ultra-sensitive SPECT-PET: a simulation study

    by Valerio Cosmi, Satyajit Ghosh, Ruud M Ramakers, Marlies C Goorden, Freek J Beekman

    Objective. Clustered pinhole (CP) collimation currently supports sub-millimeter resolution imaging up to ∼1 MeV, enabling SPECT of alpha and beta emitters with gamma emissions, simultaneous multi-isotope PET and PET/SPECT, and positron range-free PET. Nonetheless, increasing sensitivity in the original CP designs by enlarging pinhole diameters is limited, as the resulting pinhole opening cones would overlap. Approach . To address this limitation, the use of Super-Cluster (SC) collimation was evaluated in a simulation study. Two SC designs were assessed: a standard configuration (SC-ST) offering a resolution-sensitivity trade-off similar to CP, and a high-sensitivity variant (SC-HS) with larger pinhole diameters to enhance sensitivity. Their performance was compared to CP collimation for 18 F at concentrations of 1.0, 0.1, 0.05 MBq ml −1 and ⁸⁹Zr at 2.0, 0.2, 0.1 MBq ml −1 , evaluating sensitivity, image resolution, recovery coefficients, and uniformity. Main results. CP and SC-ST showed comparable sensitivity and image resolution. Both resolved 18 F rods of 0.9, 1.4, and 1.8 mm at 1.0, 0.1, and 0.05 MBq ml −1 , respectively. For ⁸⁹Zr, rods down to 1.0 mm and 1.6 mm were resolved at 2.0 and 0.2 MBq ml −1 , but none at 0.1 MBq ml −1 . Compared to CP and SC-ST, SC-HS increased sensitivity threefold for 18 F and twofold for ⁸⁹Zr. At the highest activity, SC-HS showed slightly reduced resolution for 18 F (1.0 mm) and similar for ⁸⁹Zr (1.0 mm). However, it clearly outperformed both other collimators at lower activities, resolving 18 F rods of 1.2 and 1.4 mm at 0.1 and 0.05 MBq ml −1 , respectively, and ⁸⁹Zr rods of 1.4 and 1.6 mm at 0.2 and 0.1 MBq ml −1 . Additionally, SC-HS showed superior contrast recovery. Image uniformity remained consistent across all collimators, confirming effective angular sampling. Significance. The new SC geometry enables high-sensitivity collimation for high gamma energies, improving image quality at low activities. These results demonstrate SC collimation’s strong potential for sensitivity-critical applications.

  • Open Access

    Dual-photopeak joint image reconstruction for pinhole SPECT, PET and PET-SPECT

    by Satyajit Ghosh, Valerio Cosmi, Ruud M Ramakers, Freek J Beekman, Marlies C Goorden

    Objective. Many SPECT and PET radionuclides, along with radionuclides used in targeted alpha or beta therapy and their imaging surrogates have multiple gamma and/or positron emissions. Images of these radionuclides are usually obtained from the photopeak with the most convenient energy and/or highest intensity or by adding counts from different photopeaks. Smart utilization of multiple energy peaks may improve reconstructed images, especially in low-count scans. Approach. We investigate and compare various dual-photopeak joint reconstruction (JR) approaches, namely (i) Single-Band (SB-JR)—projections from two energy windows are summed and reconstructed with a system matrix at a single average energy, (ii) mixed Multi-Band (mMB-JR)—like SB-JR but the system matrix incorporates the element-wise contributions from the photopeak energies, (iii) Multi-Band (MB-JR)—separate projections for each window and separate system matrices at relevant gamma energies are utilized. We evaluate these methods for a multi-pinhole PET-SPECT system (VECTor, MILabs, the Netherlands) using Monte Carlo generated Derenzo phantom projections of 225 Ac (218 keV and 440 keV gammas), 226 Ac (158 keV and 230 keV gammas) and 89 Zr (511 keV annihilation gammas and 909 keV prompt gammas) at three different activity concentrations. A contrast-to-noise ratio (CNR) based quantitative performance analysis was done. Main results. The MB-JR scheme of JR showed superior visual image quality and highest CNRs in almost all cases, across all radionuclides and activity concentrations. The CNR improvement over images acquired from the single best-performing photopeak ranged from 30%–65% for 225 Ac, 20%–54% for 226 Ac, and 25%–47% for 89 Zr, respectively, for the smallest visible rods in the Derenzo phantom. CNR improvements/degradations for the other two methods, mMB-JR and SB-JR, were: for 225 Ac, −16%–51% and −21%–51%; for 226 Ac, 9%–61% and 0.2%–38%; and for 89 Zr, 19%–52% and −3%–16%, respectively. Significance. We believe the proposed image reconstruction methods can enhance SPECT, PET, and PET-SPECT imaging of a wide range of radionuclides that emit gamma’s with multiple energies.


  • Open Access

    Spectral computed tomography thermometry for thermal ablation: applicability and needle artifact reduction

    by Lennart R. Koetzier, Pim Hendriks, Jan W.T. Heemskerk, Niels R. van der Werf, Mark Selles, Aart J. van der Molen, Maarten L.J. Smits, Marlies C. Goorden, Mark C. Burgmans


  • Open Access

    Optimising proton stopping power ratio prediction with spectral cone-beam CT

    by David Leibold, Dennis R Schaart, Marlies C Goorden

    Objective. Cone-beam computed tomography (CBCT) is used for patient positioning in proton therapy, but not directly for treatment planning due to its inferior image quality compared to fan-beam CT. One way to improve its value for proton radiotherapy might be to use CBCT setups capable of extracting spectral information, which can be realised through several hardware configurations. Here, we compare different setups w.r.t. to their capability of predicting proton stopping power ratios (SPRs). Approach. We investigate six different spectral CBCT realisations in a simulation study, namely a single-source setup with either a dual-layer detector or a photon-counting detector (PCD), a kVp-switching setup with either an energy-integrating detector (EID) or a PCD, and a dual-source setup with either EIDs or PCDs. Our figure of merit is the normalised Cramér–Rao Lower Bound (nCRLB) on SPR variance based on projection data. We take (cross)scatter into account, and compare ideal and realistic detector models to help guide future detector developments. Each setup is optimised w.r.t. source spectra, mAs ratios and energy bin settings (where applicable). Main results. Assuming a realistic detector response, setups with a kVp-switching source perform best, with the setup paired with an EID slightly outperforming the PCD-based setup (nCRLBs of 2.74 and 2.81, respectively). However, if the mAs ratio of the kVp-switching source is fixed, the performance of the kVp-switching setup with an EID is significantly degraded (nCRLB = 9.46) and outperformed by PCD-based setups, with nCRLBs of 3.27, 3.45 and 3.60 for the dual-source setup with two PCDs, the single-source setup and the kVp-switching setup with one PCD, respectively. Spectra with higher source voltage or wider spectral separation generally yield lower CRLB values, and avoiding the spectral distortion caused by charge sharing in direct-conversion PCDs promises to lower CRLB values by about a third. Significance. We present an extensive comparison of spectral CBCT setups for their application in proton radiotherapy, using a methodology that allows to compare their theoretical limit of performance without being influenced by the choice of reconstruction algorithm or the conversion scheme from Hounsfield units to SPR values.


  • Open Access

    Ultra-high energy spectral prompt PET

    by Satyajit Ghosh, Valerio Cosmi, Ruud M Ramakers, Freek J Beekman, Marlies C Goorden

    Objective. Utilizing prompt gammas in preclinical pinhole-collimated positron emission tomography (PET) avoids image degradation due to positron range blurring and photon down scatter, enables multi-isotope PET and can improve counting statistics for low-abundance positron emitters. This was earlier reported for 124I, 89Zr and simultaneous 124I −18F PET using the VECTor scanner (MILabs, The Netherlands), demonstrating sub-mm resolution despite long positron ranges. The aim of the present study is to investigate if such sub-mm PET imaging is also feasible for a large variety of other isotopes including those with extremely high energy prompt gammas (>1 MeV) or with complex emission spectra of prompt gammas. Approach. We use Monte Carlo simulations to assess achievable image resolutions and uniformity across a broad range of spectrum types and emitted prompt gamma energies (603 keV–2.2 MeV), using 52Mn, 94Tc, 89Zr, 44Sc, 86Y, 72As, 124I, 38K, and 66Ga. Main results. Our results indicate that sub-millimeter resolution imaging may be feasible for almost all isotopes investigated, with the currently used cluster pinhole collimators. At prompt gamma energies of 603 keV of 124I, an image resolution of ∼0.65 mm was achieved, while for emissions at 703, 744, 834, and 909 keV of 94Tc, 52Mn, 72As, and 89Zr, respectively, ∼0.7 mm resolution was obtained. Finally, at ultra-high energies of 1.2 (44Sc) and 1.4 MeV (52Mn) resolutions of ∼0.75 mm and ∼0.8 mm could still be achieved although ring artifacts were observed at the highest energies (1.4 MeV). For 38K (2.2 MeV), an image resolution of 1.2 mm was achieved utilizing its 2.2 MeV prompt emission. Significance. This work shows that current cluster pinhole collimators are suitable for sub-mm resolution prompt PET up till at least 1.4 MeV. This may open up new avenues to developing new tracer applications and therapies utilizing these PET isotopes.


  • Open Access

    Twisted clustered pinhole collimation for improved high-energy preclinical SPECT/PET

    by Valerio Cosmi, Monika Kvassheim, Satyajit Ghosh, Freek J Beekman, Marlies C Goorden

    Objective. Advanced pinhole collimation geometries optimized for preclinical high-energy ɣ imaging facilitate applications such as ɑ and ß emitter imaging, simultaneous multi-isotope PET and PET/SPECT, and positron range-free PET. These geometries replace each pinhole with a group of clustered pinholes (CPs) featuring smaller individual pinhole opening angles (POAs), enabling sub-mm resolution imaging up to ∼1 MeV. Further narrowing POAs while retaining field-of-view (FOV) may enhance high-energy imaging but faces geometrical constraints. Here, we detail how the novel twisted CPs (TCPs) address this challenge. Approach. We compared TCP and CP collimator sensitivity at equal system resolution (SR) and SR at matched sensitivity by tuning pinhole diameters for 18F (511 keV) and 89Zr (909 keV). Additionally, simulated Derenzo phantoms at low activity (LA: 12 MBq ml−1) and high activity (HA: 190 MBq ml−1) levels, along with uniformity images, were compared to assess image resolution and uniformity. Main results. At equal SR, TCP increased average central FOV sensitivity by 15.6% for 18F and 29.4% for 89Zr compared to CP. Image resolution was comparable, except for 89Zr at LA, where TCP resolved 0.80 mm diameter rods compared to 0.90 mm for CP. Image uniformity was equivalent for 18F, while for 89Zr TCP granted a 10.4% improvement. For collimators with matched sensitivity, TCP improved SR by 6.6% for 18F and 17.7% for 89Zr while also enhancing image resolution; for 18F, rods distinguished were 0.65 mm (CP) and 0.60 mm (TCP) for HA, and 0.70 mm (CP and TCP) for LA. For 89Zr, image resolutions were 0.75 mm (CP) and 0.65 mm (TCP) for HA, and 0.90 mm (CP) and 0.80 mm (TCP) for LA. Image uniformity with TCP decreased by 18.3% for 18F but improved by 20.1% for 89Zr. Significance. This study suggests that the TCP design has potential to improve high-energy ɣ imaging.


  • Open Access

    Framework for evaluating photon-counting detectors under pile-up conditions

    by David Leibold, Stefan J. van der Sar, Marlies C. Goorden, Dennis R. Schaart

    Photon-counting detectors (PCDs) herald the next leap in medical X-ray imaging, promising images with increased contrast-to-noise ratios, hence allowing for lower dose, and multi-energy imaging capabilities beyond what can be offered by dual-energy imaging,1 – 3 all of which could translate into substantial improvements in patient care. PCDs could therefore supersede the currently dominant energy-integrating detectors (EIDs) in X-ray imaging. Whereas EIDs only measure the total amount of energy deposited by X-rays in each projection, PCDs are capable of counting the number of detector pulses generated by individual X-ray photons and assigning each pulse to one of at least two energy bins. To compare and optimize the performance of different PCDs, suitable detector performance measures are needed. In particular, performance measures that have been devised for EIDs in the past may need to be adapted to the case of PCDs.


  • Open Access

    Accelerated image reconstruction by a combined dual-matrix dual-voxel approach

    by Marlies C Goorden, Chris Kamphuis, Ruud M Ramakers, Freek J Beekman

    Today, versatile emission computed tomography (VECTor) technology using dedicated high-energy collimation enables simultaneous positron emission tomography (PET) and single photon emission computed tomography (SPECT) down to 0.6 mm and 0.4 mm resolution in mice, respectively. We recently showed that for optimal resolution and quantitative accuracy of PET images the long tails of the 511 keV point spread functions (PSFs) need to be fully modelled during image reconstruction. This, however, leads to very time consuming reconstructions and thus significant acceleration in reconstruction speed is highly desirable. To this end we propose and validate a combined dual-matrix dual-voxel (DM-DV) approach: for the forward projection the slowly varying PSF tails are modelled on a three times rougher voxel grid than the central parts of the PSFs, while in the backprojection only parts of the PSF tails are included. DM-DV reconstruction is implemented in pixel-based ordered subsets expectation maximization (POSEM) and in a recently proposed accelerated pixel-based similarity-regulated ordered subsets expectation maximization (SROSEM). Both a visual assessment and a quantitative contrast-noise analysis confirm that images of a hot-rod phantom are practically identical when reconstructed with standard POSEM, DM-DV-POSEM or DM-DV-SROSEM. However, compared to POSEM, DM-DV-POSEM can reach the same contrast 5.0 times faster, while with DM-DV-SROSEM this acceleration factor increases to 11.5. Furthermore, mouse cardiac and bone images reconstructed with DM-DV-SROSEM are visually almost indistinguishable from POSEM reconstructed images but typically need an order of magnitude less reconstruction time.


  • Optimizing modelling in iterative image reconstruction for preclinical pinhole PET

    by Marlies C Goorden, Jarno van Roosmalen, Frans van der Have, Freek J Beekman

    The recently developed versatile emission computed tomography (VECTor) technology enables high-energy SPECT and simultaneous SPECT and PET of small animals at sub-mm resolutions. VECTor uses dedicated clustered pinhole collimators mounted in a scanner with three stationary large-area NaI(Tl) gamma detectors. Here, we develop and validate dedicated image reconstruction methods that compensate for image degradation by incorporating accurate models for the transport of high-energy annihilation gamma photons. Ray tracing software was used to calculate photon transport through the collimator structures and into the gamma detector. Input to this code are several geometric parameters estimated from system calibration with a scanning 99mTc point source. Effects on reconstructed images of (i) modelling variable depth-of-interaction (DOI) in the detector, (ii) incorporating photon paths that go through multiple pinholes ('multiple-pinhole paths' (MPP)), and (iii) including various amounts of point spread function (PSF) tail were evaluated. Imaging 18F in resolution and uniformity phantoms showed that including large parts of PSFs is essential to obtain good contrast-noise characteristics and that DOI modelling is highly effective in removing deformations of small structures, together leading to 0.75 mm resolution PET images of a hot-rod Derenzo phantom. Moreover, MPP modelling reduced the level of background noise. These improvements were also clearly visible in mouse images. Performance of VECTor can thus be significantly improved by accurately modelling annihilation gamma photon transport.


  • Fast Count-Regulated OSEM Reconstruction With Adaptive Resolution Recovery

    by Pieter E. B. Vaissier, Marlies C. Goorden, Aaron B. Taylor, Freek J. Beekman

    Ordered subsets expectation maximization (OSEM) is widely used to accelerate tomographic reconstruction. Speed-up of OSEM over maximum likelihood expectation maximization (MLEM) is close to the number of subsets (NS). Recently we significantly increased the speed-up achievable with OSEM by specific subset choice (pixel-based OSEM). However, a high NS can cause undesirable noise levels, quantitative inaccuracy or even disappearance of lesions in low-activity image regions, while a low NS leads to prohibitively long reconstructions or unrecovered details in highly active regions. Here, we introduce count-regulated OSEM (CROSEM) which locally adapts the effective NS based on the estimated amount of detected photons originating from individual voxels. CROSEM was tested using multi-pinhole SPECT simulations and in vivo imaging. With the maximum NS set to 128, CROSEM attained acceleration factors close to 128 in high-activity regions and kept quantitative accuracy in low-activity regions close to that of MLEM. At equal cold-lesion contrast in high-activity regions, CROSEM exhibited lower noise than MLEM in low-activity regions. CROSEM is a fast and stable alternative to OSEM, preventing excessive image noise and quantitative errors in low-activity regions while achieving high-resolution recovery in structures with high activity uptake.