Hossam M. Abuel-Naga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hossam M. Abuel-Naga has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Abdelmalek Bouazza
Professor, Dept. of Civil Engineering, Monash Univ., Building 60, Melbourne, Vic. 3800, Australia
3 shared publications - Abdelmalek Bouazza
Monash University
2 shared publications - John J. Bowders
Assistant Professor, Civil & Environmental Engineering, University of Arkansas, Fayetteville, Arkansas
1 shared publication - O. Collazos
Department of Civil and Environmental Engineering, Polytechnic University of Puerto Rico PO Box 191234, San Juan, PR 00919-1234, Puerto Rico Telephone: +1 787 529 4207, Telefax: +1 787 771 0011
1 shared publication
Latest Publications
- 1 April 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 139 (4) , 539-547
Thermomechanical Behavior of Saturated Geosynthetic Clay Liners
The aim of this study is to assess experimentally the volume change behavior of geosynthetic clay liners (GCLs) under elevated temperatures. Such elevated temperatures can be generated in landfills as the result of biological decomposition of organic matter in municipal solid waste. A modified consolidometer capable of handling temperatures up to 60°C was utilized for this purpose. A series of thermomechanical consolidation tests were performed on two different GCLs at different elevated temperatures, varying from 20 to 60°C, and different vertical stress levels (50, 100, and 150 kPa). The results show that the thermally induced volume change is stress dependent. A preliminary conceptual explanation for this behavior is introduced and discussed in this study.
- 1 April 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 139 (4) , 539-547
Thermomechanical Behavior of Saturated Geosynthetic Clay Liners
The aim of this study is to assess experimentally the volume change behavior of geosynthetic clay liners (GCLs) under elevated temperatures. Such elevated temperatures can be generated in landfills as the result of biological decomposition of organic matter in municipal solid waste. A modified consolidometer capable of handling temperatures up to 60°C was utilized for this purpose. A series of thermomechanical consolidation tests were performed on two different GCLs at different elevated temperatures, varying from 20 to 60°C, and different vertical stress levels (50, 100, and 150 kPa). The results show that the thermally induced volume change is stress dependent. A preliminary conceptual explanation for this behavior is introduced and discussed in this study.
- 11 March 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 2031-2038
On GCLs' Gas Permeability for Modelling of Gas Leakage Rate through GM/GCL Composite Liner Due to a Defect in the Geomembrane
The aim of this paper is to assess the validity of the geosynthetic clay liner (GCL) gas permeability coefficient obtained by the conventional testing approach for predicting gas leakage rate of GM/GCL composite liner due to a defect in the geomembrane. As a GCL is a composite-layered material, its permeability is a function of the permeability of its components (i.e bentonite and geotextiles) and flow direction. In order to investigate GCL's flow pattern under leakage condition, numerical experiments were conducted where for sake of simplicity the interface zone between the GM and the GCL has been ignored. The results show the inadequacy of using the GCL's gas permeability coefficient, obtained by the conventional testing approach, alone to predict the leakage rate. Instead, this value should be used along with the permeability coefficient of the GCL's geotextile layer to accurately describe the flow through GCL under leakage condition.
- 11 March 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 2031-2038
On GCLs' Gas Permeability for Modelling of Gas Leakage Rate through GM/GCL Composite Liner Due to a Defect in the Geomembrane
The aim of this paper is to assess the validity of the geosynthetic clay liner (GCL) gas permeability coefficient obtained by the conventional testing approach for predicting gas leakage rate of GM/GCL composite liner due to a defect in the geomembrane. As a GCL is a composite-layered material, its permeability is a function of the permeability of its components (i.e bentonite and geotextiles) and flow direction. In order to investigate GCL's flow pattern under leakage condition, numerical experiments were conducted where for sake of simplicity the interface zone between the GM and the GCL has been ignored. The results show the inadequacy of using the GCL's gas permeability coefficient, obtained by the conventional testing approach, alone to predict the leakage rate. Instead, this value should be used along with the permeability coefficient of the GCL's geotextile layer to accurately describe the flow through GCL under leakage condition.
- 1 October 2010
- Published by Emerald Publishing in Geosynthetics International
- Vol. 17 (5) , 313-322
A novel laboratory technique to determine the water retention curve of geosynthetic clay liners
The aim of this paper is to discuss the suitability of different soil laboratory techniques for determining the water retention curve (WRC) of geosynthetic clay liners (GCLs), and to introduce a new testing method that takes into consideration the special geometric and structural configurations of GCLs. A modified triaxial apparatus was built for this purpose. The originality of this apparatus rests on a needle system attached to the conventional triaxial cap, which allows control of the moisture content of the tested specimen on the wetting path. Suction measurements were conducted using two different sensors: a thermocouple psychrometer and a relative humidity sensor. The applicability of the developed system was demonstrated by testing the GCL sample on the wetting path. The results obtained agree well with the data available in the literature. It is believed that the advantage of the developed testing system can be ascribed to its ability to control the moisture content on the wetting path and temperature of the tested specimen under triaxial stress conditions.
- 1 October 2010
- Published by Emerald Publishing in Geosynthetics International
- Vol. 17 (5) , 313-322
A novel laboratory technique to determine the water retention curve of geosynthetic clay liners
The aim of this paper is to discuss the suitability of different soil laboratory techniques for determining the water retention curve (WRC) of geosynthetic clay liners (GCLs), and to introduce a new testing method that takes into consideration the special geometric and structural configurations of GCLs. A modified triaxial apparatus was built for this purpose. The originality of this apparatus rests on a needle system attached to the conventional triaxial cap, which allows control of the moisture content of the tested specimen on the wetting path. Suction measurements were conducted using two different sensors: a thermocouple psychrometer and a relative humidity sensor. The applicability of the developed system was demonstrated by testing the GCL sample on the wetting path. The results obtained agree well with the data available in the literature. It is believed that the advantage of the developed testing system can be ascribed to its ability to control the moisture content on the wetting path and temperature of the tested specimen under triaxial stress conditions.
- 1 November 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 135 (11) , 1661-1671
Numerical Characterization of Advective Gas Flow through GM/GCL Composite Liners Having a Circular Defect in the Geomembrane
Numerical experiments were conducted to understand the effect of geometric and transport characteristics of a geomembrane-geosynthetic clay liner (GM/GCL) composite liner on gas leakage rate through a circular defect in the geomembrane (GM). The originality of the approach proposed in this paper rests on the use of a new conceptual two-layered system for modeling of GM/GCL composite liners where the interface zone between the GM and geosynthetic clay liner (GCL) has been merged with the GCL cover geotextile and handled as one layer; the GCL bentonite layer was considered the second layer. The role of the carrier geotextile layer was ignored since it can be considered as a no pressure loss layer. Analysis of numerical simulation results shows the existence of a constitutive leakage flow surface which enables evaluation of the leakage flow state for different geometric and transport properties of GM/GCL composite liners. Furthermore, the determined surface was also exploited to evaluate gas leakage rates un...
- 1 November 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 135 (11) , 1661-1671
Numerical Characterization of Advective Gas Flow through GM/GCL Composite Liners Having a Circular Defect in the Geomembrane
Numerical experiments were conducted to understand the effect of geometric and transport characteristics of a geomembrane-geosynthetic clay liner (GM/GCL) composite liner on gas leakage rate through a circular defect in the geomembrane (GM). The originality of the approach proposed in this paper rests on the use of a new conceptual two-layered system for modeling of GM/GCL composite liners where the interface zone between the GM and geosynthetic clay liner (GCL) has been merged with the GCL cover geotextile and handled as one layer; the GCL bentonite layer was considered the second layer. The role of the carrier geotextile layer was ignored since it can be considered as a no pressure loss layer. Analysis of numerical simulation results shows the existence of a constitutive leakage flow surface which enables evaluation of the leakage flow state for different geometric and transport properties of GM/GCL composite liners. Furthermore, the determined surface was also exploited to evaluate gas leakage rates un...
- 1 June 2008
- Published by Emerald Publishing in Geosynthetics International
- Vol. 15 (3) , 216-223
Numerical evaluation of prefabricated vertical drain enhanced soil vapour extraction system
The aim of this study is to investigate numerically the performance of a prefabricated vertical drain (PVD) as a soil vapour extraction well, and the pattern of the induced air flow. A validated numerical model for a single PVD extraction well is developed based on the result of a well-designed laboratory air-pumping test. The results of the validated numerical model are used to evaluate the flow efficiency of a PVD extraction well. The validity of the simple analytical approach to determine air permeability based on the results of air-pumping tests is also discussed. The output of this study highlights the influence of PVD well resistance on the overall performance of soil vapour extraction systems, and the effect of the PVD's oblong cross-section on the air flow characteristics.
- 1 June 2008
- Published by Emerald Publishing in Geosynthetics International
- Vol. 15 (3) , 216-223
Numerical evaluation of prefabricated vertical drain enhanced soil vapour extraction system
The aim of this study is to investigate numerically the performance of a prefabricated vertical drain (PVD) as a soil vapour extraction well, and the pattern of the induced air flow. A validated numerical model for a single PVD extraction well is developed based on the result of a well-designed laboratory air-pumping test. The results of the validated numerical model are used to evaluate the flow efficiency of a PVD extraction well. The validity of the simple analytical approach to determine air permeability based on the results of air-pumping tests is also discussed. The output of this study highlights the influence of PVD well resistance on the overall performance of soil vapour extraction systems, and the effect of the PVD's oblong cross-section on the air flow characteristics.