PBPeter Boekstegers

Peter Boekstegers

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Boekstegers has a total of 70 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Kupatt

    First Department of Medicine, Cardiology, Klinikum rechts der Isar, Technical University of Munich, School of Medicine and Health, Munich, Germany

    6 shared publications
  • Sandra Eifert

    Herzchirurgische Klinik und Poliklinik, Transplantationszentrum, Klinikum Großhadern, LMU München, Marchioninistr. 15, 81377, München, Deutschland.

    4 shared publications
  • B Reichart

    3 shared publications
  • Gerhard Steinbeck

    From the Departments of Internal Medicine I (P.B., P.R., R.H., T.P., C.K., A.K., G.S.), Anesthesiology (F.C.), and Cardiac Surgery (S.E., B.R., C.V.), Grosshadern University Hospital, Munich, Germany

    3 shared publications
  • Philip Raake

    From the Departments of Internal Medicine I (P.B., P.R., R.H., T.P., C.K., A.K., G.S.), Anesthesiology (F.C.), and Cardiac Surgery (S.E., B.R., C.V.), Grosshadern University Hospital, Munich, Germany

    3 shared publications
  • Rabea Hinkel

    Laboratory Animal Science Unit, German Primate Center, Leibniz Institute for Primate Research, Göttingen, Germany

    3 shared publications

Latest Publications

  • First transaxillary aortic valve replacement in a heart transplant recipient

    by M Wolf, R Sodian, P Boekstegers, C Kupatt, R Schramm, S Michel, J Abicht, M Primaychenko, B Reichart, C Schmitz

    Introduction: Long-term outcome after HTx is still limited due to chronic graft vasculopathy, valve calcification, endocarditis, renal failure, diabetes, and lymphoproliverative disease. Valve associated long-term complications after heart transplantation (HTx) are always challenging. Over the last years, transcatheter aortic valve implantation (TAVI) has been established in many centers and has proven to be a save alternative, particularly in patients requiring redo-surgery. Aims: There are several reports on heart valve disease after orthotopic HTx due to degeneration and calcification or endocarditis. We describe here the case of a 79-year old patient 14 years after HTx with severe aortic stenosis. Co-morbidities were renal failure requiring chronic dialysis, insulin-dependent diabetes mellitus, hypertension and hyperuricaemia. The patient was no candidate for femoral TAVI because of severe calcifications of the femoral vessels, and no candidate for transapical TAVI because of the size of the aortic annulus (26mm). Therefore we decided to implant a 29mm Medtronic CoreValve via the axillary artery. The patient was put on ventilation, and the left axillary artery was prepared surgically. The insertion sheet was placed using the Seldinger technique. Retrograde valve implantation was uneventful. The patient stayed 3 days on ICU and was discharged on postoperative day 9. Discussion: Aortic stenosis after HTx may be difficult to handle. Patients after HTx have an increased risk for major operative complications. TAVI offers an alternative approach to conventional AVR with re-sternotomy and cardiopulmonary bypass. If transfemoral and transapical approaches are impossible, the transaxillary approach may be a valuable alternative.

    • 16 May 2007
      • Vol. 2  (1) , 98-9

    Cardioprotective Potential of Thymosin s4 in a Preclinical Pig Model of Ischemia/Reperfusion Injury.

    by R Hinkel, C El Aouni, I Bock-Marquette, A Hatzopoulos, P Boekstegers, Christian Kupatt


  • Arterial T-Graft in Coronary Surgery: Comparison of Selective Coronary Angiography and Multi-Slice Computed Tomography

    by S. Eifert, M. Oberhoffer, B. Wintersperger, B. Reichart, P. Boekstegers, C. Vicol

    Background: The main aim of our study was to compare the results and value of angiography and multi-slice computed tomography (MSCT) after coronary artery bypass grafting using complex arterial conduit combinations. Methods: Twenty-six patients underwent coronary surgery. In all patients, we utilized a T-graft (free arterial graft centrally implanted into the left internal thoracic artery in situ). Postoperative coronary angiography and MSCT were carried out prior to discharge. The results were interpreted separately by two different investigators. Results: One hundred and thirteen distal anastomoses using 59 grafts for T-graft combinations were performed in 26 patients. A mean of 3.5 peripheral anastomoses was established per patient. Angiography showed a bypass graft patency rate of 94.6 % (56/59). In angiography, the patency rate of anastomoses was 96.5 % (109/113). All occlusions were identified in sequential anastomoses. The bypass patency rate measured by MSCT was 100 % and the patency rate of anastomoses 100 %. Based on these results, MSCT showed a sensitivity of 98.9 %. The specificity was 50.8 %, the positive predictive value was 94.6 % and the negative predictive value had a level of 99.9 %. Conclusion: MSCT is a simple, less invasive and useful method of monitoring results after coronary surgery including anastomosis and graft patency after complex arterial grafts. Its value may be restricted for sequential anastomoses and angiography should be preferentially used in these cases.


  • Midterm angiographic evaluation of coronary bypass graft distal anastomosis by use of a magnetic coupler

    by S Eifert, M Oberhoffer, P Boekstegers, F Christ, B Reichart, C Vicol

    Aims: Main goal of anastomotic devices is to improve patency of bypass grafts while reducing the invasive nature of conventional myocardial revascularization. We analysed our midterm results with the Magnetic Vascular Positioner (MVP®), an automated distal anastomotic device. Methods and material: Eighteen anastomoses were performed in 11 patients by use of the MVP®. Target artery for the MVP® anastomosis were 9 left anterior descending arteries, 4 x first marginal branch, 3 x first diagonal branch, and twice the right coronary artery. The left internal thoracic artery was utilized as graft in 9, saphenous vein in 6, right internal thoracic artery in 2, and radial artery in one patient, respectively. The 2mm size MVP® was utilized in 12 cases and the 1.5mm in 6. Coronary angiography was carried out on postoperative day 10 and on a mean of 19 months (range 13 to 25 months) postoperatively. Results: In all cases the use of the device was initially successful as demonstrated in coronary angiography. Coronary angiography of the MVP® anastomoses at follow-up showed a patency rate of 83.3%. All hand-sewn anastomoses were patent (100%). The MVP® anastomosis was occluded in one radial artery graft, one left and one right internal thoracic artery. These three anastomoses were performed with small (1.5mm) MVP® devices. Conclusion: Midterm patency of distal anastomoses performed by use of the MVP® is acceptable but inferior to the patency of hand-sewn anastomoses. Bypass occlusion may be produced by small device size or unfavourable particularities of coronary blood flow.

  • T-grafts in coronary surgery: Comparison of arterial coronary angiography and multi slice computed tomography

    by S Eifert, M Oberhoffer, B Wintersperger, P Boekstegers, B Reichart, C Vicol

    Objectives: Main focus of our study was to compare the results and value of angiography and multi slice computed tomography (MSCT) after coronary artery bypass grafting (CABG) using complex conduit combinations. Generally, MSCT is considered to be less sensitive and less specific regarding bypass patency, but has the considerable advantage of being a less invasive. Material and methods: Twenty six patients underwent elective coronary surgery. In all patients, we utilized a T-Graft consisting of a free right internal thoracic or radial artery centrally implanted into the left internal thoracic artery. Postoperative angiography and MSCT including volume rendering were undertaken on postoperative day 8. Angiography and MSCT were interpreted separately by two different investigators and then compared. Results: Ninety one distal anastomoses by use of 61 grafts were performed in 26 patients with an average number of 3.5 peripheral anastomoses. Angiography showed a bypass graft patency rate of 90.2% (55/61). In angiography, the patency rate of anastomoses measured 91.2% (83/91). Bypass patency rate by MSCT measured was 90.2% (56/61) and the patency rate of anastomoses 93.4% (85/91). Based on these results MSCT showed a sensitivity of 97.6%. Specificity was 66.7% and predictive accuracy measured 97.6%. Conclusion: MSCT is suitable as control after CABG regarding bypass graft patency, especially for complex conduit combinations such as the T-graft. It allows a reliable visualization of patent or occluded bypass grafts and is a less invasive method compared to angiography. The ability to quantify stenosis is restricted.

  • Hemodynamic and Vascular Effects of Ventricular Sourcing by Stent-Based Ventricle to Coronary Artery Bypass in Patients With Multivessel Disease Undergoing Coronary Artery Bypass Surgery

    by Peter Boekstegers, Philip Raake, Rabea Hinkel, Tilmann Pohl, Christian Kupatt, Andreas Knez, Frank Christ, Sandra Eifert, Gerhard Steinbeck, Bruno Reichart, et al.

    Background— The hemodynamic and vascular effects of ventricular sourcing by a stent-based (VSTENT, Percardia) left ventricle-to-coronary artery bypass were studied in a patient subgroup of the European multicenter ADVANTAGE study (ADjunctive treatment with the VCAB/VSTENT myocardial implANT system in coronary Artery bypass Graft patiEnts). Methods and Results— Twelve patients who underwent VSTENT implantation in addition to coronary artery bypass surgery were studied up to 12 months after the procedure. The VSTENT was implanted distal to a hemodynamically relevant coronary artery stenosis. Coronary flow velocity was assessed at rest and during dobutamine stress. Intraoperative VSTENT implantation was successful in 11 of 12 patients. Early postoperative angiograms showed patent VSTENT in 8 of 11 patients, with predominantly systolic flow distal to the VSTENT. Coronary flow velocity reserve induced by dobutamine stress was 1.7±0.1 ( P =0.006). VSTENT patency at 2- to 6-month follow-up was present in 5 of 11 patients, with concomitant VSTENT stenosis in 4 of those 5. In all patients, coronary flow velocity increased 3- to 4-fold proximal to the VSTENT, which was associated with a moderate degree of arterial remodeling. Except for target vessel reintervention (n=5), no other major adverse events were observed in 11 of 12 patients. One patient died on the second postoperative day, though the cause was probably not related to the VSTENT implantation. Conclusions— VSTENT implantation seems to be safe in the mid-term follow-up and leads to a predominantly systolic coronary flow pattern in the vessel supplied by the VSTENT, with a flow reserve similar or close to that seen with conventional bypass. VSTENT patency rate, however, was unacceptably low at 3- to 6-month follow-up and needs to be improved.


  • Open Access

    Percutaneous approach to a stent-based ventricle to coronary vein bypass (venous VPASS™): comparison to catheter-based selective pressure-regulated retro-infusion of the coronary vein

    by Philip Raake, Rabea Hinkel, Christian Kupatt, Marie-Luise von Brühl, Sabrina Beller, Martin Andrees, Calin Vicol, Peter Boekstegers

    Aims Percutaneous stent-based ventricle-to-coronary vein bypass (venous VPASS™) is a new approach to chronic venous arterialization as a treatment modality in an otherwise no option patient with coronary artery disease. In this study, the efficacy of venous VPASS™ was compared with catheter-based selective pressure-regulated retro-infusion of arterial blood during acute ischaemia. Methods and results In seven pigs, venous VPASS™ was established using a percutaneous ultrasound-guided puncture from the anterior cardiac vein to the left ventricle, with subsequent implantation of an ePTFE-covered stent graft. During left anterior descending artery (LAD) occlusion, coronary venous pressure in the distal anterior cardiac vein increased to 55±4 mmHg under conditions of venous VPASS™ compared with 78±5 mmHg during selective pressure-regulated retro-infusion. Significant preservation of regional myocardial function was observed during venous VPASS™ (67±6% baseline) and during selective retro-infusion (83±4%) compared with control LAD occlusion (0.4±2%). Conclusion Percutaneous implantation of a PTFE covered stent (venous VPASS™) was feasible and associated with significant preservation of regional myocardial function during acute ischaemia in pigs at reasonable levels of mean coronary venous pressure to avoid tissue damage during chronic application.


  • Adjunctive treatment with a stent-based ventricle to coronary artery bypass (VSTENTTM) in patients with multivessel coronary artery disease undergoing bypass surgery (ADVANTAGE): Pilot phase

    by C. Vicol, S. Eifert, B. Reichart, P. Raake, R. Hinkel, G. Steinbeck, P. Boekstegers

    Objectives: We here report on the pilot phase of a multicenter European study (ADVANTAGE) using a stent-based approach for surgical ventricle-to-coronary artery bypass (VSTENTTM). In addition to providing flow to the distal vessel, collateral development and arterial remodeling might be induced by VSTENTTM implantation. Material and Methods: In 12 patients (61±13years) undergoing multivessel coronary artery bypass surgery a VSTENTTM was implanted between the left ventricle and a marginal branch (n=6), a diagonal branch (n=4) or a trifurcation branch (n=2) distal to a high grade coronary artery stenosis. Surgery was performed on-pump with arrested heart in 4, on-pump with beating heart in 6 and off-pump in 2 patients. Epicardial coronary blood flow measurements (flow wire) including determination of adenosine induced flow reserve and dobutamine stress testing were performed before and after VSTENTTM implantation. Results: Flow wire measurements assessed before and 7 days after VSTENTTM implantation revealed a change of coronary flow pattern from diastolic to predominantly systolic (systolic/diastolic flow ratio: 0.3±0.1 to 1.6±0.3; pConclusions: Surgical VSTENTTM implantation was feasible and safe in the short-term follow-up and was associated with a significant change of coronary flow pattern from diastolic to predominantly systolic flow distal to a high grade stenosis of the native vessel at rest and under stress testing.

  • Stent-Based Approach for Ventricle–to–Coronary Artery Bypass

    by Peter Boekstegers, Philip Raake, Rasul Al Ghobainy, Jan Horstkotte, Rabea Hinkel, Torleif Sandner, Reinhard Wichels, Franz Meisner, Eckehard Thein, Keith March, et al.

    Background— Ventricle-to–coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. Methods and Results— In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70±6% and regional myocardial function at 71±8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a “valve-like mechanism” was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation ( r =0.88; P Conclusions— VSTENT for ventricle-to–coronary artery bypass was feasible and preserved 70±6% of baseline flow during complete LAD occlusion. The degree of preservation was dependent on the position of the VSTENT creating a valve-like mechanism during diastole. Residual diastolic blood flow through a high-grade LAD stenosis influenced net flow favorably, because diastolic backflow decreased with increasing mean diastolic intracoronary pressure.


  • Pressure-guided nonsurgical myocardial reduction induced by small septal infarctions in hypertrophic obstructive cardiomyopathy

    by Peter Boekstegers, Peter Steinbigler, Alexander Molnar, Martin Schwaiblmair, Alexander Becker, Andreas Knez, Ralph Haberl, Gerhard Steinbeck