Hemodynamic and Vascular Effects of Ventricular Sourcing by Stent-Based Ventricle to Coronary Artery Bypass in Patients With Multivessel Disease Undergoing Coronary Artery Bypass Surgery
- 30 August 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 112 (9_suppleme) , I304-10
Abstract
Background— The hemodynamic and vascular effects of ventricular sourcing by a stent-based (VSTENT, Percardia) left ventricle-to-coronary artery bypass were studied in a patient subgroup of the European multicenter ADVANTAGE study (ADjunctive treatment with the VCAB/VSTENT myocardial implANT system in coronary Artery bypass Graft patiEnts). Methods and Results— Twelve patients who underwent VSTENT implantation in addition to coronary artery bypass surgery were studied up to 12 months after the procedure. The VSTENT was implanted distal to a hemodynamically relevant coronary artery stenosis. Coronary flow velocity was assessed at rest and during dobutamine stress. Intraoperative VSTENT implantation was successful in 11 of 12 patients. Early postoperative angiograms showed patent VSTENT in 8 of 11 patients, with predominantly systolic flow distal to the VSTENT. Coronary flow velocity reserve induced by dobutamine stress was 1.7±0.1 ( P =0.006). VSTENT patency at 2- to 6-month follow-up was present in 5 of 11 patients, with concomitant VSTENT stenosis in 4 of those 5. In all patients, coronary flow velocity increased 3- to 4-fold proximal to the VSTENT, which was associated with a moderate degree of arterial remodeling. Except for target vessel reintervention (n=5), no other major adverse events were observed in 11 of 12 patients. One patient died on the second postoperative day, though the cause was probably not related to the VSTENT implantation. Conclusions— VSTENT implantation seems to be safe in the mid-term follow-up and leads to a predominantly systolic coronary flow pattern in the vessel supplied by the VSTENT, with a flow reserve similar or close to that seen with conventional bypass. VSTENT patency rate, however, was unacceptably low at 3- to 6-month follow-up and needs to be improved.Keywords
This publication has 15 references indexed in Scilit:
- First Clinical Experience With the VSTENT: A Device for Direct Left Ventricle-to-Coronary Artery BypassThe Annals of Thoracic Surgery, 2005
- First human experience with stent‐based ventricle‐to‐coronary artery bypassCatheterization and Cardiovascular Interventions, 2004
- Arterial enlargement, tortuosity, and intimal thickening in response to sequential exposure to high and low wall shear stressJournal of Vascular Surgery, 2004
- Description and evaluation of a ventriculo-coronary artery bypass device that provides bi-directional coronary flowEuropean Journal of Cardio-Thoracic Surgery, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryThe New England journal of medicine, 2003
- Effect of Endothelial Shear Stress on the Progression of Coronary Artery Disease, Vascular Remodeling, and In-Stent Restenosis in HumansCirculation, 2003
- Stent-Based Approach for Ventricle–to–Coronary Artery BypassCirculation, 2002
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002
- Regional myocardial blood flow reserve impairment and metabolic changes suggesting myocardial ischemia in patients with idiopathic dilated cardiomyopathyJACC, 2000
- Dobutamine Stress Testing in the Cardiac Catheterization LaboratoryThe American Journal of Cardiology, 1996