Alexander N. Cartwright
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander N. Cartwright has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Albert H. Titus
Departments of Electrical Engineering and Biomedical Engineering, University at Buffalo, Buffalo NY 14260 USA
4 shared publications - Qiaoqiang Gan
Sustainable Photonics Energy Research Laboratory, Material Science Engineering, PSE, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
4 shared publications - Bin Qu
Department of Electrical Engineering, University at Buffalo, Buffalo, NY 14260 USA
3 shared publications - Daniel R. Bednarek
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Stephen Rudin
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Vincent K. S. Hsiao
Department of Applied Materials and Optoelectronic Engineering, National Chi Nan University, NanTou 54561, Taiwan
3 shared publications
Latest Publications
- Open Access
- 23 August 2017
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 2 (8) , 4838-4844
Frozen “Tofu” Effect: Engineered Pores of Hydrophilic Nanoporous Materials
Frozen tofu is a famous Asian food made by freezing soft bean curds, which are naturally porous to store flavor and nutrients. When the narrow pores of the soft bean curd are saturated with water and then frozen, pore widths expand to generate a completely new porous structure—frozen tofu has visibly wider pores than the initial bean curd. Intriguingly, this principle can be generalized and applied to manipulate micro/nanopores of functional porous materials. In this work, we will manipulate the pore size of nanoporous polymeric photonic crystals based on the phase change between water and ice. Wet-drying and freeze-drying methods were applied to shrink or expand the pore size intentionally. This principle is validated by directly observing the optical reflection peak shift of the material. Owing to the change in pore size, the reflection peak of the polymeric photonic crystal structure can be permanently, and intentionally, tuned. This simple but elegant mechanism is promising for the development of smart materials/devices for applications ranging from oil/water membrane separations, health monitoring, and medical diagnostics to environmental monitoring, anticounterfeiting, and smart windows.
- 23 August 2017
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 2 (8) , 4838-4844
Open AccessFrozen “Tofu” Effect: Engineered Pores of Hydrophilic Nanoporous Materials
Frozen tofu is a famous Asian food made by freezing soft bean curds, which are naturally porous to store flavor and nutrients. When the narrow pores of the soft bean curd are saturated with water and then frozen, pore widths expand to generate a completely new porous structure—frozen tofu has visibly wider pores than the initial bean curd. Intriguingly, this principle can be generalized and applied to manipulate micro/nanopores of functional porous materials. In this work, we will manipulate the pore size of nanoporous polymeric photonic crystals based on the phase change between water and ice. Wet-drying and freeze-drying methods were applied to shrink or expand the pore size intentionally. This principle is validated by directly observing the optical reflection peak shift of the material. Owing to the change in pore size, the reflection peak of the polymeric photonic crystal structure can be permanently, and intentionally, tuned. This simple but elegant mechanism is promising for the development of smart materials/devices for applications ranging from oil/water membrane separations, health monitoring, and medical diagnostics to environmental monitoring, anticounterfeiting, and smart windows.
- Open Access
- 9 August 2016
- Published by IOP Publishing in Nanotechnology
- Vol. 27 (37) , 374003
Flat metallic surface gratings with sub-10 nm gaps controlled by atomic-layer deposition
Atomic layer lithography is a recently reported new technology to fabricate deep-subwavelength features down to 1–2 nm, based on combinations of electron beam lithography (EBL) and atomic layer deposition (ALD). However, the patterning area is relatively small as limited by EBL, and the fabrication yield is not very high due to technical challenges. Here we report an improved procedure to fabricate flat metallic surfaces with sub-10 nm features based on ALD processes. To demonstrate the scalability of the new manufacturing method, we combine the ALD process with large area optical interference patterning, which is particularly promising for the development of practical applications for nanoelectronics and nanophotonics with extremely strong confinement of electromagnetic fields.
- 9 August 2016
- Published by IOP Publishing in Nanotechnology
- Vol. 27 (37) , 374003
Open AccessFlat metallic surface gratings with sub-10 nm gaps controlled by atomic-layer deposition
Atomic layer lithography is a recently reported new technology to fabricate deep-subwavelength features down to 1–2 nm, based on combinations of electron beam lithography (EBL) and atomic layer deposition (ALD). However, the patterning area is relatively small as limited by EBL, and the fabrication yield is not very high due to technical challenges. Here we report an improved procedure to fabricate flat metallic surfaces with sub-10 nm features based on ALD processes. To demonstrate the scalability of the new manufacturing method, we combine the ALD process with large area optical interference patterning, which is particularly promising for the development of practical applications for nanoelectronics and nanophotonics with extremely strong confinement of electromagnetic fields.
- Open Access
Creating Diversified Response Profiles from a Single Quenchometric Sensor Element by Using Phase-Resolved Luminescence
We report a new strategy for generating a continuum of response profiles from a single luminescence-based sensor element by using phase-resolved detection. This strategy yields reliable responses that depend in a predictable manner on changes in the luminescent reporter lifetime in the presence of the target analyte, the excitation modulation frequency, and the detector (lock-in amplifier) phase angle. In the traditional steady-state mode, the sensor that we evaluate exhibits a linear, positive going response to changes in the target analyte concentration. Under phase-resolved conditions the analyte-dependent response profiles: (i) can become highly non-linear; (ii) yield negative going responses; (iii) can be biphasic; and (iv) can exhibit super sensitivity (e.g., sensitivities up to 300 fold greater in comparison to steady-state conditions).
Open AccessCreating Diversified Response Profiles from a Single Quenchometric Sensor Element by Using Phase-Resolved Luminescence
We report a new strategy for generating a continuum of response profiles from a single luminescence-based sensor element by using phase-resolved detection. This strategy yields reliable responses that depend in a predictable manner on changes in the luminescent reporter lifetime in the presence of the target analyte, the excitation modulation frequency, and the detector (lock-in amplifier) phase angle. In the traditional steady-state mode, the sensor that we evaluate exhibits a linear, positive going response to changes in the target analyte concentration. Under phase-resolved conditions the analyte-dependent response profiles: (i) can become highly non-linear; (ii) yield negative going responses; (iii) can be biphasic; and (iv) can exhibit super sensitivity (e.g., sensitivities up to 300 fold greater in comparison to steady-state conditions).
- 2 November 2014
- Published by Springer Nature
- p. 217-235
Tailoring Nonlinear Interactions in Metamaterials
- 2 November 2014
- Published by Springer Nature
- p. 217-235
Tailoring Nonlinear Interactions in Metamaterials
- Open Access
- 18 February 2014
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 6 (5) , 3081-3087
Holographic Photopolymer Linear Variable Filter with Enhanced Blue Reflection
A single beam one-step holographic interferometry method was developed to fabricate porous polymer structures with controllable pore size and location to produce compact graded photonic bandgap structures for linear variable optical filters. This technology is based on holographic polymer dispersed liquid crystal materials. By introducing a forced internal reflection, the optical reflection throughout the visible spectral region, from blue to red, is high and uniform. In addition, the control of the bandwidth of the reflection resonance, related to the light intensity and spatial porosity distributions, was investigated to optimize the optical performance. The development of portable and inexpensive personal health-care and environmental multispectral sensing/imaging devices will be possible using these filters.
- 18 February 2014
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 6 (5) , 3081-3087
Open AccessHolographic Photopolymer Linear Variable Filter with Enhanced Blue Reflection
A single beam one-step holographic interferometry method was developed to fabricate porous polymer structures with controllable pore size and location to produce compact graded photonic bandgap structures for linear variable optical filters. This technology is based on holographic polymer dispersed liquid crystal materials. By introducing a forced internal reflection, the optical reflection throughout the visible spectral region, from blue to red, is high and uniform. In addition, the control of the bandwidth of the reflection resonance, related to the light intensity and spatial porosity distributions, was investigated to optimize the optical performance. The development of portable and inexpensive personal health-care and environmental multispectral sensing/imaging devices will be possible using these filters.
- 22 February 2012
- Published by Wiley in Advanced Materials
- Vol. 24 (12) , 1604-1609
One‐Step Fabrication of Graded Rainbow‐Colored Holographic Photopolymer Reflection Gratings
A one‐step fabrication method has been developed to realize graded holographic photopolymer reflection gratings with gradually varied period in the lateral direction, leading to a rainbow‐colored reflection image in the same viewing angle. This low‐cost rainbow‐colored filter can be integrated with detectors or imaging devices to realize compact and portable spectroscopic analyzers.
- 22 February 2012
- Published by Wiley in Advanced Materials
- Vol. 24 (12) , 1604-1609
One‐Step Fabrication of Graded Rainbow‐Colored Holographic Photopolymer Reflection Gratings
A one‐step fabrication method has been developed to realize graded holographic photopolymer reflection gratings with gradually varied period in the lateral direction, leading to a rainbow‐colored reflection image in the same viewing angle. This low‐cost rainbow‐colored filter can be integrated with detectors or imaging devices to realize compact and portable spectroscopic analyzers.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 2634-2637
Image geometric corrections for a new EMCCD-based dual modular x-ray imager
An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2×1 array design efficiently increased the clinical field of view, and also can be readily expanded to an MxN array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048×1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 2634-2637
Image geometric corrections for a new EMCCD-based dual modular x-ray imager
An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2×1 array design efficiently increased the clinical field of view, and also can be readily expanded to an MxN array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048×1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules.
- 29 October 2010
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 1 (4) , 041011
Holographically Fabricated Dye-Doped Nanoporous Polymers as Matrix for Laser Desorption/Ionization Mass Spectrometry
We report laser desorption/ionization mass spectrometry using a dye-doped nanoporous polymer matrix. The nanoporous polymer matrix was fabricated through a holographic interference patterning technique. The periodically aligned nanopores in the resulting polymer matrix produced a high surface-to-volume ratio that facilitates the homogeneous cocrystallization of the matrix and an analyte (i.e., peptide in this demonstration). To generate nanostructures with further enhanced functionalities, dyes were also incorporated into the photopolymer. We demonstrate that by using the dye-doped nanoporous polymer matrix, we can identify peptides with an enhanced signal from the peptides and decreased noise from the ion fragmentation. These results indicate that the dye-doped nanoporous polymer matrix we use here can be a promising platform for laser desorption/ionization mass spectrometry.
- 29 October 2010
- Published by Wiley in Journal of Nanotechnology in Engineering and Medicine
- Vol. 1 (4) , 041011
Holographically Fabricated Dye-Doped Nanoporous Polymers as Matrix for Laser Desorption/Ionization Mass Spectrometry
We report laser desorption/ionization mass spectrometry using a dye-doped nanoporous polymer matrix. The nanoporous polymer matrix was fabricated through a holographic interference patterning technique. The periodically aligned nanopores in the resulting polymer matrix produced a high surface-to-volume ratio that facilitates the homogeneous cocrystallization of the matrix and an analyte (i.e., peptide in this demonstration). To generate nanostructures with further enhanced functionalities, dyes were also incorporated into the photopolymer. We demonstrate that by using the dye-doped nanoporous polymer matrix, we can identify peptides with an enhanced signal from the peptides and decreased noise from the ion fragmentation. These results indicate that the dye-doped nanoporous polymer matrix we use here can be a promising platform for laser desorption/ionization mass spectrometry.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2607-2609
Optical demonstration of a medical imaging system with an EMCCD-sensor array for use in a high resolution dynamic X-ray imager
Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2607-2609
Optical demonstration of a medical imaging system with an EMCCD-sensor array for use in a high resolution dynamic X-ray imager
Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 3438-3441
Quantum performance analysis of an EMCCD-based x-ray detector using photon transfer technique
The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detector's field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 e - /DN at unit gain, with a read noise of 71.5±6.0 e - rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 ke - , providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 3438-3441
Quantum performance analysis of an EMCCD-based x-ray detector using photon transfer technique
The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detector's field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 e - /DN at unit gain, with a read noise of 71.5±6.0 e - rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 ke - , providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected.